Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
1.
J Am Soc Echocardiogr ; 33(9): 1087-1094, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32651124

RESUMO

BACKGROUND: Current echocardiographic guidelines recommend that tricuspid regurgitation (TR) severity be graded in three categories, following assessment of specific parameters. Findings from recent trials have shown that the severity of TR frequently far exceeds the current definition of severe. We postulated that a grading approach that emphasizes outcomes could be useful to identify patients with severe TR at increased risk of mortality. METHODS: We identified 284 patients with echocardiograms demonstrating severe functional TR, defined as vena contracta (VC) ≥ 0.7 cm. Demographics and mortality data were obtained from the medical records. Patients were divided into study (n = 122 patients with three-dimensional images) and validation (n = 162) cohorts. The VC was measured in both the right ventricular (RV) inflow and apical four-chamber views and averaged. For the study cohort, tricuspid annular, RV end-diastolic (basal, mid, long axis) dimensions, tricuspid leaflet tenting height and area, RV free-wall longitudinal strain, and RV volumes were measured from two- and three-dimensional data sets. A K-partition algorithm was used in the study cohort to derive a mortality-related cutoff VC value, above which TR was termed "massive." The ability of this VC cutoff to identify patients at greater mortality risk was then tested in the validation cohort using Kaplan-Meier survival analysis. RESULTS: In the study cohort, VC > 0.92 cm (massive TR) was optimally associated with worse survival. Tricuspid annular and RV size were larger in the massive group (P < .05), while there were no significant differences in demographics between the TR groups. Importantly, in the independent validation cohort, the above VC cutoff also correlated with increased mortality in the massive group (log-rank P < .05). CONCLUSIONS: Among patients traditionally defined as having severe TR, a subset exists with massive TR, resulting in greater adverse RV remodeling and increased mortality. These patients may derive the greatest benefit from emerging percutaneous therapies.


Assuntos
Insuficiência da Valva Tricúspide , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Remodelação Ventricular
2.
Int J Cardiovasc Imaging ; 36(1): 33-43, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31432289

RESUMO

Tricuspid annular (TA) size, assessed by 2D transthoracic echocardiography (TTE), has a well-established prognostic value in patients undergoing mitral valve surgery, with TA dilatation triggering simultaneous tricuspid annuloplasty. While TA dilatation is common in patients with dilated atria secondary to atrial fibrillation, little is known about the mechanisms of TA dilatation in patients with sinus rhythm (SR). This study aimed to identify echocardiographic parameters most closely related to the TA size as a potential tool for identification of patients prone to developing TA enlargement. 120 patients with SR underwent clinically indicated TTE, including 30 patients with normal hearts and 90 patients diagnosed with at least one right heart abnormality, defined as: right ventricular (RV) or right atrial (RA) dilatation, ≥ moderate tricuspid regurgitation (TR) and elevated systolic pulmonary artery pressure (sPAP). RA and RV end-diastolic and end-systolic volumes (EDV, ESV) and function were measured using commercial 3D software (TomTec). 3D RV long and short axes were used as surrogate indices of RV shape. Degrees of TR and sPAP were estimated by 2D TTE. 3D TA sizing was performed at end-diastole using 3D custom software. Linear regression analysis was used to identify variables best correlated with TA size, followed by multivariate analysis to identify independent associations. The highest correlations were found between TA area and: RA ESV (r = 0.73; p < 0.01), RV EDV (r = 0.58; p < 0.01), RV end-diastolic long and short axes (r = 0.53, 0.42; both p < 0.01), TR degree (r = 0.40; p < 0.01) and sPAP (r = 0.32; p < 0.01). Multivariate analysis revealed that RA ESV was the only parameter independently associated with TA area (p < 0.05, r = 0.85). In conclusion, RA volume plays an important role in TA dilatation even in patients with normal SR. Understanding of annular remodeling mechanisms could aid in identifying patients at higher risk for TA dilatation, especially those scheduled for mitral valve surgery.


Assuntos
Ecocardiografia Tridimensional , Hemodinâmica , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Adulto , Idoso , Pressão Arterial , Função do Átrio Direito , Remodelamento Atrial , Chicago , Dilatação Patológica , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Valva Tricúspide/patologia , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/patologia , Insuficiência da Valva Tricúspide/fisiopatologia , Função Ventricular Direita
3.
Int J Cardiovasc Imaging ; 36(2): 271-278, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31583499

RESUMO

Increased vascular stiffness is known to be an independent predictor of mortality in patients with heart failure with reduced ejection fraction (HFrEF). The effects of sacubitril-valsartan on vascular structure and function have not been systematically studied in this patient population. We hypothesized that aortic distensibility (AD) and fractional area change (AFAC), as assessed by 2D transthoracic echocardiography (TTE), would improve over time in HFrEF patients on sacubitril-valsartan therapy, due to the vasodilatory properties of the medication. We prospectively studied 30 patients with HFrEF (25 < EF < 40%) on optimal guideline-directed medical therapy who were subsequently started on sacubitril-valsartan. Patients underwent serial 2D TTE imaging at baseline, 3 and 6 months following therapy initiation. Ascending aortic diameters were measured 3 cm above the aortic valve in the parasternal long-axis view and used to calculate AD and AFAC, two markers of vascular compliance. For reference, we also measured AD and AFAC in 30 healthy, age and gender-matched controls at a single time point. Normal controls had significantly higher values of AD and AFAC than HFrEF patients at baseline (AD: 4.0 ± 1.1 vs. 2.2 ± 0.9 cm2dyne-110-3, p < 0.0001 and AFAC: 18.8 ± 3.7% vs. 10.3 ± 4.3%, p < 0.0001). In HFrEF patients on sacubitril-valsartan, both indices of aortic compliance progressively improved towards normal from baseline to 6 months: AD from 2.2 ± 0.9 to 3.6 ± 1.5 cm2dyne-110-3 (p < 0.0001) and AFAC from 10.3 ± 4.3 to 13.7 ± 4.1% (p < 0.0001). In conclusion, AD and AFAC are decreased in patients with HFrEF and gradually improve with sacubitril-valsartan treatment. The echocardiographic markers used in this study may become a useful tool to assess the effectiveness of sacubitril-valsartan therapy in HFrEF patients.


Assuntos
Aminobutiratos/uso terapêutico , Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Inibidores de Proteases/uso terapêutico , Tetrazóis/uso terapêutico , Rigidez Vascular/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Adulto , Idoso , Aminobutiratos/efeitos adversos , Bloqueadores do Receptor Tipo 1 de Angiotensina II/efeitos adversos , Compostos de Bifenilo , Estudos de Casos e Controles , Combinação de Medicamentos , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Neprilisina/antagonistas & inibidores , Valor Preditivo dos Testes , Estudos Prospectivos , Inibidores de Proteases/efeitos adversos , Tetrazóis/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Valsartana
4.
J Am Soc Echocardiogr ; 32(8): 969-977, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31174940

RESUMO

BACKGROUND: Three-dimensional echocardiography (3DE) allows accurate and reproducible measurements of right ventricular (RV) size and function. However, widespread implementation of 3DE in routine clinical practice is limited because the existing software packages are relatively time-consuming and skill demanding. The aim of this study was to test the accuracy and reproducibility of new machine learning- (ML-) based, fully automated software for three-dimensional quantification of RV size and function. METHODS: Fifty-six unselected patients with a wide range of RV size and function and image quality, referred for clinically indicated cardiac magnetic resonance (CMR) imaging, underwent a transthoracic 3DE exam on the same day. End-systolic and end-diastolic RV volumes (ESV, EDV) and ejection fraction (EF) were measured using the ML-based algorithm and compared with CMR reference values using Bland-Altman and linear regression analyses. RESULTS: RV function quantification by echocardiography was feasible in all patients. The automatic approach was accurate in 32% patients with analysis time of 15 ± 1 seconds and 100% reproducible. Endocardial contour editing was necessary after the automated postprocessing in the remaining 68% patients, prolonging analysis time to 114 ± 71 seconds. With these minimal adjustments, RV volumes and EF measurements were accurate in comparison with CMR reference (biases: EDV, -25.6 ± 21.1 mL; ESV, -7.4 ± 16 mL; EF, -3.3% ± 5.2%) and showed excellent reproducibility reflected by coefficients of variation <7% and intraclass correlations ≥0.95 for all measurements. CONCLUSIONS: The new ML-based 3DE algorithm provided accurate and completely reproducible RV volume and EF measurements in one-third of unselected patients without any boundary editing. In the remaining patients, quick minimal editing resulted in reasonably accurate measurements with excellent reproducibility. This approach provides a promising solution for fast three-dimensional quantification of RV size and function.


Assuntos
Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Aprendizado de Máquina , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
5.
Int J Cardiovasc Imaging ; 35(9): 1573-1579, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30937684

RESUMO

Severely reduced left ventricular (LV) ejection fraction (EF) derived from 2D echocardiographic (2DE) images is associated with increased mortality and used to guide therapeutic choices. Global longitudinal strain (GLS) is more sensitive than LVEF to detect abnormal LV function, and accordingly may help identify patients with mildly-to-moderately reduced LVEF who are at a similarly high cardiovascular (CV) risk. We hypothesized that 3D echocardiographic (3DE) measurements of EF and GLS, which are more reliable and reproducible, may have even better predictive value than the 2DE indices, and compared their ability to identify such patients. We retrospectively studied 104 inpatients with 2DE-derived LVEF of 30-50% who underwent transthoracic echocardiography during 2006-2010 period, had good quality images, and were followed-up through 2016. Both 2DE and 3DE images were analyzed to measure LVEF and GLS. Kaplan-Meier survival curves were generated for two subgroups defined by the median of each parameter as the cutoff. Of the 104 patients, 32 died of CV related causes. Cox regression revealed that 3D GLS was the only variable associated with CV mortality. Kaplan-Meier curves showed that 2D LVEF, 2D GLS and 3D EF were unable to differentiate patients at higher CV mortality risk, but 3D GLS was the only parameter to do so. Because 3D GLS is able to identify patients with mildly-to-moderately reduced LVEF who are at higher CV mortality risk, its incorporation into clinical decisions may improve survival of those who would benefit from therapeutic interventions not indicated according to the current guidelines.


Assuntos
Ecocardiografia Tridimensional , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Disfunção Ventricular Esquerda/fisiopatologia
6.
J Am Soc Echocardiogr ; 32(2): 238-247, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30459122

RESUMO

BACKGROUND: Evaluation of the tricuspid annulus is crucial for the decision making at the time of left heart surgery. Current recommendations for tricuspid valve repair are based on two-dimensional (2D) transthoracic echocardiography (TTE), despite the known underestimation compared with three-dimensional (3D) echocardiography. However, little is known about the differences in 3D tricuspid annular (TA) sizing using TTE versus transesophageal echocardiography (TEE). The aims of this study were to (1) compare 2D and 3D TA measurements performed with both TTE and TEE and (2) compare two 3D methods for TA measurements: multiplanar reconstruction (MPR) and dedicated software (DS) designed to take into account TA nonplanarity. METHODS: Seventy patients underwent 2D and 3D TTE and TEE. Two-dimensional images were used to measure TA diameter from apical four-chamber, right ventricular-focused (TTE), and midesophageal four-chamber (TEE) views. Three-dimensional full-volume data sets were analyzed using both MPR and DS, to obtain major and minor axes, perimeter, and area. Intertechnique agreement was assessed using Bland-Altman analysis. RESULTS: Measurements on 2D TTE and TEE, which were view dependent, underestimated TA major dimensions in all views compared with 3D values, irrespective of the 3D method. MPR and DS measurements were significantly different, with DS resulting in larger values for all parameters, irrespective of approach. No differences were found between 3D TTE and 3D TEE for both MPR and DS. CONCLUSIONS: Our findings highlight the need for methodology that respects the 3D geometry of the tricuspid annulus, including its nonplanarity, which cannot be accurately assessed from 2D images and is not equally taken into account by different 3D measurement methodologies. Accordingly, a 3D cutoff value for TA enlargement needs to be established and is likely to be larger than the guideline-recommended 2D-based 40-mm cutoff. Importantly, noninvasive 3D TTE can be used instead of 3D TEE because TA measurements are not different.


Assuntos
Tomada de Decisões , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Tricúspide/diagnóstico , Valva Tricúspide/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
7.
J Am Soc Echocardiogr ; 31(11): 1221-1228, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30205909

RESUMO

BACKGROUND: Left atrial (LA) longitudinal strain is a novel parameter used for the evaluation of LA function, with demonstrated prognostic value in several cardiac diseases. However, the extent of load dependency of LA strain is not well known. The aim of this study was to evaluate the impact of acute changes in preload on LA strain, side by side with LA volume, in normal subjects. METHODS: Twenty-five healthy volunteers (13 men; mean age, 31 ± 2 years) were prospectively enrolled, who underwent two-dimensional and three-dimensional echocardiographic imaging during acute stepwise reductions in preload using a tilt maneuver: baseline at 0°, followed by 40° and 80°. Left ventricular and LA size and function parameters were measured using standard methodology, and LA strain-time curves were obtained using speckle-tracking software (TomTec), resulting in reservoir, conduit, and contractile strain components. All parameters were compared among the three loading conditions using one-way analysis of variance for repeated measurements. RESULTS: Although there were no significant changes in blood pressure, heart rate increased significantly with tilt. As expected, LA volumes, left ventricular volumes, and left ventricular ejection fraction, as well as E wave, A wave, and e' significantly decreased with progressive inclination. In parallel, LA reservoir, conduit, and contractile strain values decreased with reduction in preload (reservoir: 42.9 ± 3.9% to 27.5 ± 3.8%, P < .001; conduit: 29.3 ± 2.7% to 20.2 ± 5.0%, P < .001; contractile: 13.6 ± 2.9% to 7.3 ± 3.5%, P < .001). Paired post hoc analysis showed that all LA strain values were significantly different among all three tilt phases. Of note, percentage change in LA reservoir strain was significantly smaller than that in LA maximum volume. CONCLUSIONS: In normal subjects, LA strain is preload dependent but to a lesser degree than LA volume. This difference underscores the relative advantage of LA strain over maximum volume, when LA assessment is used as part of the diagnostic paradigm.


Assuntos
Função do Átrio Esquerdo/fisiologia , Ecocardiografia Doppler/métodos , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Adulto , Feminino , Seguimentos , Voluntários Saudáveis , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Função Ventricular Esquerda/fisiologia
8.
J Am Soc Echocardiogr ; 31(11): 1161-1167, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30097300

RESUMO

BACKGROUND: The prevalence of isolated cleft mitral valve (MV; no concomitant congenital heart disease or degenerative MV disease) with significant mitral regurgitation (MR) diagnosed using two-dimensional echocardiography (2DE) has been reported to be very low. Three-dimensional echocardiography (3DE) has enabled a more comprehensive visualization of the MV and detailed understanding of the mechanisms of MR and can potentially reveal isolated cleft MV that is not recognized with 2DE. The aim of this study was to determine, using 3DE, the prevalence, location, and associated MV annular and left ventricular characteristics of isolated cleft MV, in the absence of associated congenital heart disease, in patients with significant MR. METHODS: A total of 1,092 patients with unexplained moderate or greater MR on two-dimensional transthoracic echocardiography who were referred for three-dimensional transesophageal echocardiography between 2005 and 2017 (n = 626) were retrospectively studied. Left ventricular dimensions and function were determined, and quantitative MR assessment and three-dimensional analysis of the MV annulus was performed. RESULTS: Twenty-one patients (prevalence 3.3%) were diagnosed with isolated cleft MV using three-dimensional transesophageal echocardiography but not 2DE. The majority of these patients (n = 16) were noted to have anterior cleft MVs, with most located in the mid-A1 (n = 10) or mid-A3 (n = 5) scallops. Posterior clefts were less common (n = 5) and occurred at the site of the natural scallop indentations (three between P1 and P2 and two between P2 and P3). Among patients with either anterior or posterior MV cleft, there were no differences in left ventricular ejection fraction or three-dimensional MV geometry (annular distance, height, circumference, and area). There was a trend toward worse MR severity in patients with anterior cleft MV. CONCLUSIONS: In patients with otherwise unexplained significant MR referred for transesophageal echocardiography, 3DE uncovered a considerably higher prevalence of isolated cleft MV than previously reported by 2DE, with the majority located in the anterior MV. Although the annular geometry was similar between patients with anterior and posterior cleft MVs, a trend toward more severe MR in anterior clefts may reflect underlying abnormalities in the embryologic development of the anterior MV leaflet. Evaluation of MV pathology is improved by 3DE, which should be used routinely in the setting significant MR.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico , Valva Mitral/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
9.
Echocardiography ; 35(10): 1606-1615, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30044511

RESUMO

Preservation of native left ventricular (LV) function in patients supported with LV assist device (LVAD) may be beneficial to attain optimal hemodynamics and enhance potential recovery. Currently, LVAD speed optimization is based on hemodynamic parameters, without considering residual native LV function. We hypothesized that alternatively, LV rotational mechanics can be quantified by 3D echocardiography (3DE), and may help preserve native LV function while optimizing LVAD speed. The goal of this study was to test the feasibility of quantifying the effects of LVAD implantation on LV rotational mechanics and to determine whether conventional speed optimization maximally preserves native LV function. We studied 55 patients with LVADs, who underwent 3DE imaging and quantitative analysis of LV twist. Thirty patients were studied before and after LVAD implantation. The remaining 25 patients were studied during hemodynamic ramp studies. The pump speed at which LV twist was maximal was compared with the hemodynamics-based optimal speed. LV twist decreased following LVAD implantation from 4.2 ± 2.7 to 2.3 ± 1.9° (P < 0.01), reflecting the constricting effects on native function. With lower pump speeds, no significant changes were noted in LV twist, which peaked at a higher speed. In 11/25 (44%) patients, the conventional hemodynamic/2DE methodology and 3DE assessment of maximal residual function did not indicate the same optimal conditions, suggesting that a higher pump speed would have better preserved native function. In conclusion, quantitative 3DE analysis of LV rotational mechanics provides information, which together with hemodynamics may help select optimal pump speed, while maximally preserving native LV function.


Assuntos
Ecocardiografia Tridimensional/métodos , Coração Auxiliar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Função Ventricular Esquerda
10.
Hypertension ; 72(1): 188-193, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29844146

RESUMO

Women with hypertensive disorders of pregnancy have an increased risk of subsequent heart failure and cardiovascular disease when compared with women with normotensive pregnancies. Although the mechanisms underlying these findings are unclear, elevated levels of the biomarker activin A are associated with myocardial dysfunction and may have predictive value. We hypothesized that elevated levels of antepartum activin A levels would correlate with postpartum cardiac dysfunction in women with hypertensive disorders of pregnancy. We prospectively studied 85 women to determine whether increased antepartum activin A levels were associated with cardiac dysfunction at 1 year postpartum as measured by global longitudinal strain. Thirty-two patients were diagnosed with preeclampsia, 28 were diagnosed with gestational or chronic hypertension, and the remainder were nonhypertensive controls. Activin A levels were measured with ELISA both in the third antepartum trimester and at 1 year postpartum. Comprehensive echocardiograms including measurement of global longitudinal strain were also performed at enrollment and at 1 year postpartum. Antepartum activin A levels correlated with worsening antepartum global longitudinal strain (r=0.70; P=0.0001). Across the entire cohort, elevated antepartum activin A levels were associated with the development of abnormal global longitudinal strain at 1 year (C statistic 0.74; P=0.004). This association remained significant after multivariable adjustment for clinically relevant confounders (C statistic 0.93; P=0.01). Postpartum activin A levels also correlated with increasing left ventricular mass index (P=0.02), increasing mean arterial pressures (P=0.02), and decreasing E' values (P=0.01). Activin A may be a useful tool for identifying and monitoring patients at risk for postpartum development of cardiovascular disease.


Assuntos
Ativinas/sangue , Pressão Sanguínea/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Induzida pela Gravidez/fisiopatologia , Período Pós-Parto , Disfunção Ventricular Esquerda/sangue , Função Ventricular Esquerda/fisiologia , Adulto , Biomarcadores/sangue , Estudos de Casos e Controles , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Gravidez , Terceiro Trimestre da Gravidez , Estudos Prospectivos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia
11.
Eur Heart J Cardiovasc Imaging ; 19(1): 47-58, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28159984

RESUMO

Aims: Although recommended by current guidelines, adoption of three-dimensional echocardiographic (3DE) chamber quantification in clinical practice has lagged because of time-consuming analysis. We recently validated an automated algorithm that measures left atrial (LA) and left ventricular (LV) volumes and ejection fraction (EF). This study aimed to determine the accuracy and reproducibility of these measurements in a multicentre setting. Methods and results: 180 patients underwent 3DE imaging (Philips) at six sites. Images were analysed using automated HeartModel (HM) software with endocardial border correction when necessary and by manual tracing. Measurements were performed by each site and by the Core Laboratory (CL) as the reference. Inter-technique comparisons included HM measurements by the sites against manual tracing by CL, and showed strong correlations (r-values: LVEDV: 0.97, LVESV: 0.97, LVEF: 0.88, LAV: 0.96), with the automated technique slightly underestimating LV volumes (biases: LVEDV: -14 ± 20 ml, LVESV: -6 ± 20 ml), LVEF (-2 ± 7%) and LAV (-9 ± 10 ml). Intra-technique comparisons included HM measurements by the sites against CL, with and without corrections. Corrections were unnecessary or minimal in most patients, and improved the measurements only modestly. Comparisons without corrections showed perfect agreement for all parameters. With corrections, correlations were better (r-values: LVEDV: 0.99, LVESV: 0.99, LVEF: 0.94, LAV: 0.99) and biases (LVEDV: -8 ± 12 ml, LVESV: -6 ± 12 ml, LVEF: 1 ± 5%, LAV: -10 ± 6 ml) smaller than in inter-technique comparison. All automated measurements with corrections were more reproducible than manual measurements. Conclusion: Automated 3DE analysis of left-heart chambers is an accurate alternative to conventional manual methodology, which yields almost the same values across laboratories and is more reproducible. This technique may contribute towards full integration of 3DE quantification into clinical routine.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Volume Sistólico/fisiologia , Adulto , Função do Átrio Esquerdo/fisiologia , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda/fisiologia
12.
J Am Soc Echocardiogr ; 31(3): 297-303, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29174339

RESUMO

BACKGROUND: Although left ventricular global longitudinal strain (GLS) is an index of systolic function recommended by the guidelines, poor image quality may hamper strain measurements. While contrast agents are commonly used to improve endocardial visualization, no commercial speckle-tracking software is able to measure strain in contrast-enhanced images. This study aimed to test the accuracy of speckle-tracking software when applied to contrast-enhanced images in patients with suboptimal image quality. METHODS: We studied patients with a wide range of GLS values who underwent transthoracic echocardiography. Protocol 1 included 44 patients whose images justified use of contrast but still allowed noncontrast speckle-tracking echocardiography (STE), which was judged as accurate and used as a reference. Protocol 2 included 20 patients with poor image quality that precluded noncontrast STE; cardiac magnetic resonance- (CMR-) derived strain was used as the reference instead. Half the manufacturer recommended dose of a commercial contrast agent (Definity/Optison/Lumason) was used to provide partial contrast enhancement. Higher than normal mechanical indices (0.6-0.7) and lowest frequency range for maximal penetration settings were used for imaging. GLS was measured (Epsilon) with and without contrast-enhanced images and by CMR-derived feature tracking (TomTec). Comparisons included linear regression and Bland-Altman analyses. RESULTS: The contrast STE analysis failed in 4/64 patients (6%). Manual corrections were needed to optimize tracking with contrast in all patients. GLS measurements were in good agreement between contrast and noncontrast images (r = 0.85; mean GLS in the contrast images, -12.9% ± 4.7%; bias, 0.34% ± 2.4%). Good agreement was also noted between contrast STE- and CMR-derived strain (r = 0.83; mean, GLS -13.5% ± 4.0%; bias, 0.72% ± 2.5%). CONCLUSIONS: We found that GLS measurements from contrast-enhanced images are feasible and accurate in most patients, even in those with poor image quality that precludes strain measurements without contrast enhancement.


Assuntos
Cardiomiopatias/diagnóstico , Meios de Contraste/farmacologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Cardiomiopatias/fisiopatologia , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
JACC Cardiovasc Imaging ; 11(11): 1569-1579, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29153577

RESUMO

OBJECTIVES: This study hypothesized that left ventricular (LV) ejection fraction (EF) and global longitudinal strain (GLS) derived from 3-dimensional echocardiographic (3DE) images would better predict mortality than those obtained by 2-dimensional echocardiographic (2DE) measurements, and that 3DE-based LV shape analysis may have added prognostic value. BACKGROUND: Previous studies have shown that both LVEF and GLS derived from 2DE images predict mortality. Recently, 3DE measurements of these parameters were found to be more accurate and reproducible because of independence of imaging plane and geometric assumptions. Also, 3DE analysis offers an opportunity to accurately quantify LV shape. METHODS: We retrospectively studied 416 inpatients (60 ± 18 years of age) referred for transthoracic echocardiography between 2006 and 2010, who had good-quality 2DE and 3DE images were available. Mortality data through 2016 were collected. Both 2DE and 3DE images were analyzed to measure LVEF and GLS. Additionally, 3DE-derived LV endocardial surface information was analyzed to obtain global shape indices (sphericity and conicity) and regional curvature (anterior, septal, inferior, lateral walls). Cardiovascular (CV) mortality risks related to these indices were determined using Cox regression. RESULTS: Of the 416 patients, 208 (50%) died, including 114 (27%) CV-related deaths over a mean follow-up period of 5 ± 3 years. Cox regression revealed that age and body surface area, all 4 LV function indices (2D EF, 3D EF, 2D GLS, 3D GLS), and regional shape indices (septal and inferior wall curvatures) were independently associated with increased risk of CV mortality. GLS was the strongest prognosticator of CV mortality, superior to EF for both 2DE and 3DE analyses, and 2D EF was the weakest among the 4 functional indices. A 1% decrease in GLS magnitude was associated with an 11.3% increase in CV mortality risk. CONCLUSIONS: GLS predicts mortality better than EF by both 3DE and 2DE analysis, whereas 3D EF is a better predictor than 2D EF. Also, LV shape indices provide additional risk assessment.


Assuntos
Ecocardiografia Tridimensional , Cardiopatias/diagnóstico por imagem , Cardiopatias/mortalidade , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Feminino , Cardiopatias/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
14.
J Am Soc Echocardiogr ; 30(12): 1193-1202, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29050828

RESUMO

BACKGROUND: Three-dimensional (3D) echocardiography directly assesses right ventricular (RV) volumes without geometric assumptions, despite the complex shape of the right ventricle, and accordingly is more accurate and reproducible than the two-dimensional methodology, which is able to measure only surrogate parameters of RV function. Volumetric analysis has been hampered by frequent inability to clearly visualize RV endocardium, especially the RV free wall, in 3D echocardiographic images. The aim of this study was to test the hypothesis that RV contrast enhancement during 3D echocardiographic imaging would improve the accuracy of RV volume and function analysis. METHODS: Thirty patients with a wide range of RV size and function and image quality underwent transthoracic 3D echocardiography with and without contrast enhancement and cardiovascular magnetic resonance imaging on the same day. RV end-diastolic and end-systolic volumes and ejection fraction were measured from contrast-enhanced and nonenhanced 3D echocardiographic images and compared with cardiovascular magnetic resonance reference values using linear regression and Bland-Altman analyses. Blinded repeated measurements were performed to assess measurement variability. RESULTS: RV contrast enhancement was feasible in all patients. RV volumes obtained both with and without contrast enhancement correlated highly with cardiovascular magnetic resonance (end-diastolic volume, r = 0.90 and r = 0.92; end-systolic volume, r = 0.92 and r = 0.94, respectively), but the correlation for ejection fraction was better with contrast (r = 0.87 vs r = 0.70). Biases were smaller with contrast for all three parameters (end-diastolic volume, -16 ± 23 vs -36 ± 25 mL; end-systolic volume, -10 ± 16 vs -23 ± 18 mL; ejection fraction, -0.7 ± 5.5% vs -2.7 ± 8.1% of the mean measured values), reflecting improved accuracy. Also, measurement reproducibility was improved by contrast enhancement. CONCLUSIONS: Contrast enhancement improves the visualization of RV endocardial borders, resulting in more accurate and reproducible 3D echocardiographic measurements of RV size and function. This approach may be particularly useful in patients with suboptimal image quality.


Assuntos
Volume Cardíaco/fisiologia , Meios de Contraste/farmacologia , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico , Função Ventricular Direita/fisiologia , Idoso , Estudos de Viabilidade , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Tamanho do Órgão , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Direita/fisiopatologia
15.
J Am Soc Echocardiogr ; 30(9): 879-885, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28688857

RESUMO

BACKGROUND: Although 3D echocardiography (3DE) allows accurate and reproducible quantification of cardiac chambers, it has not been integrated into clinical practice because it relies on manual input, which interferes with workflow. A recently developed automated adaptive analytics algorithm for simultaneous quantification of left ventricular and atrial (LV, LA) volumes was found to be accurate and reproducible in patients with good images. We sought to prospectively test its feasibility and accuracy in consecutive patients in relationship with image quality and reader experience. METHODS: Three hundred consecutive patients underwent 3DE. Image quality was graded as poor, adequate, or good. Images were analyzed by an expert echocardiographer to obtain LV volumes and ejection fraction (EF) and LA volume using the automated analysis (HeartModel, Philips, Andover, MA) with and without editing the endocardial boundaries and using conventional manual tracing (QLAB, Philips, Andover, MA) blinded to the automated measurements as a reference. In a subgroup of 100 patients, automated analysis was repeated by two readers without 3DE experience. RESULTS: Automated analysis failed in 31/300 patients (10%). Patients with poor image quality (n = 72, 24%) showed suboptimal agreement with the reference technique, especially for LVEF. Importantly, patients with adequate (n = 89, 30%) and good (n = 108, 36%) images showed small biases and excellent correlations without border corrections, which were further improved with editing. In contrast, border corrections by inexperienced readers did not improve the agreement with reference values. CONCLUSIONS: Automated 3DE analysis allows accurate quantification of left-heart size and function in 66% of consecutive patients, while in the remaining patients, its performance is limited/unreliable due to image quality. Border corrections require 3DE experience to improve the accuracy of the automated measurements. In patients with sufficient image quality, this automated approach has the potential to overcome the workflow limitations of the 3D analysis in clinical practice.


Assuntos
Algoritmos , Volume Cardíaco/fisiologia , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Seleção de Pacientes , Disfunção Ventricular Esquerda/diagnóstico , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
16.
JACC Cardiovasc Imaging ; 9(7): 769-782, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27318718

RESUMO

OBJECTIVES: The goal of this study was to test the feasibility and accuracy of an automated algorithm that simultaneously quantifies 3-dimensional (3D) transthoracic echocardiography (TTE)-derived left atrial (LA) and left ventricular (LV) volumes and left ventricular ejection fraction (LVEF). Conventional manual 3D TTE tracings and cardiac magnetic resonance (CMR) images were used as a reference for comparison. BACKGROUND: Cardiac chamber quantification from 3D TTE is superior to 2D TTE measurements. However, integration of 3D quantification into clinical practice has been limited by time-consuming workflow and the need for 3D expertise. A novel automated software was developed that provides LV and LA volumetric quantification from 3D TTE datasets that reflect real-life manual 3-dimensional echocardiography measurements and values comparable to CMR. METHODS: A total of 159 patients were studied in 2 separate protocols. In protocol 1, 94 patients underwent 3D TTE imaging (EPIQ, iE33, X5-1, Philips Healthcare, Andover, Massachusetts) covering the left atrium and left ventricle. LA and LV volumes and LVEF were obtained using the automated software (HeartModel, Philips Healthcare) with and without contour correction, and compared with the averaged manual 3D volumetric measurements from 3 readers. In protocol 2, automated measurements from 65 patients were compared with a CMR reference. The Pearson correlation coefficient, Bland-Altman analysis, and paired Student t tests were used to assess inter-technique agreement. RESULTS: Correlations between the automated and manual 3D TTE measurements were strong (r = 0.87 to 0.96). LVEF was underestimated and automated LV end-diastolic, LV end-systolic, and LA volumes were overestimated compared with manual measurements. Agreement between the automated analysis and CMR was also strong (r = 0.84 to 0.95). Test-retest variability was low. CONCLUSIONS: Automated simultaneous quantification of LA and LV volumes and LVEF is feasible and requires minimal 3D software analysis training. The automated measurements are not only comparable to manual measurements but also to CMR. This technique is highly reproducible and timesaving, and it therefore promises to facilitate the integration of 3D TTE-based left-heart chamber quantification into clinical practice.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Isquemia Miocárdica/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Função do Átrio Esquerdo , Automação , Estudos de Viabilidade , Feminino , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Fluxo de Trabalho
17.
J Electrocardiol ; 49(3): 383-91, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27046100

RESUMO

We evaluate in this paper different strategies for the construction of a statistical shape model (SSM) of the left ventricle (LV) to be used for segmentation in cardiac magnetic resonance (CMR) images. From a large database of LV surfaces obtained throughout the cardiac cycle from 3D echocardiographic (3DE) LV images, different LV shape models were built by varying the considered phase in the cardiac cycle and the registration procedure employed for surface alignment. Principal component analysis was computed to describe the statistical variability of the SSMs, which were then deformed by applying an active shape model (ASM) approach to segment the LV endocardium in CMR images of 45 patients. Segmentation performance was evaluated by comparing LV volumes derived by ASM segmentation with different SSMs and those obtained by manual tracing, considered as a reference. A high correlation (r(2)>0.92) was found in all cases, with better results when using the SSM models comprising more than one frame of the cardiac cycle.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia/métodos , Endocárdio/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/diagnóstico por imagem , Simulação por Computador , Endocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Disfunção Ventricular Esquerda/patologia
18.
Eur Heart J Cardiovasc Imaging ; 17(5): 500-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26710820

RESUMO

AIMS: In functional mitral regurgitation (FMR), increased leaflet area has been described as a remodelling compensatory mechanism. We hypothesized that chordae tendineae elongation would also occur as part of this remodelling. In this study, the lengths of primary chords and measurements of mitral leaflets and annulus were compared with varying degrees of mitral regurgitation (MR). METHODS AND RESULTS: We studied 58 patients who underwent three-dimensional (3D) transoesophageal echocardiography, including 38 with FMR and 20 with normal mitral valves (NL). The FMR group was divided into two subgroups according to two-dimensional vena contracta width (VCW). Three-dimensional datasets from transgastric or mid-oesophageal approach were used to measure primary chordal length, coaptation length, inter-papillary muscle distances, and quantitative 3D measurements of the annulus and leaflets. Leaflet surface area was increased and coaptation length was decreased in FMR compared with NL. While no difference in other 3D measurement of annulus/leaflets was noted between the FMR subgroups, averaged chordal length was shorter in patients with more severe FMR. Chords of the anterior leaflet in FMR with larger VCW were shorter compared with both NL and FMR with smaller VCW. In contrast, the chords of the posterior leaflet were longer in FMR with smaller VCW compared with the other two groups. CONCLUSION: Our results suggest the posterior leaflet chords possibly remodel by elongating and contribute to reduced MR and that in a subgroup of FMR patients, the primary chords may remodel by shortening, resulting in augmented MR. This information could be useful in choosing strategy for FMR correction.


Assuntos
Cordas Tendinosas/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
19.
Eur Heart J Cardiovasc Imaging ; 17(5): 564-75, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26160404

RESUMO

AIMS: Right ventricular (RV) remodelling involves changes in size, function, and shape. Although three-dimensional echocardiography (3DE) allows imaging of RV morphology, regional RV shape analysis has not been evaluated using 3DE. We developed a technique to quantify RV shape and tested its ability to differentiate normal from pressure overloaded right ventricles. Methods Transthoracic 3DE RV images were acquired in 54 subjects, including 39 patients with pulmonary artery hypertension (PAH) and 15 normal controls (NL). 3D RV surfaces were reconstructed (TomTec) at end-diastole and end-systole (ED, ES) and processed using custom software to calculate mean curvature of the inflow and outflow tracts (RVIT, RVOT), apex, and body (both divided into free wall and septum). METHODS AND RESULTS: Septal segments (apical and body) in NLs were characterized by concavity (curvature < 0) in ED and slight convexity (curvature > 0) in ES. In PAH, however, the septum remained convex, bulging into the left ventricle throughout the cardiac cycle. In keeping with the 'bellows-like' action of RV contraction in the NL group, the body free wall transitioned from a convex surface at ED to a more flattened surface at ES, while the apex free wall progressed from a less convex surface at ED to a more convex surface at ES. In contrast, in PAH, both RV free-wall segments (apical and body) remained equally convex throughout the cardiac cycle. CONCLUSIONS: Curvature analysis using 3D echocardiography allows quantitative evaluation of RV remodelling, which could be used to track differential changes in regional RV shape, as a way to assess disease progression or regression.


Assuntos
Ecocardiografia Doppler/métodos , Ecocardiografia Tridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Hipertensão Pulmonar/diagnóstico por imagem , Remodelação Ventricular , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão Pulmonar/patologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
20.
J Am Soc Echocardiogr ; 28(11): 1302-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26384765

RESUMO

BACKGROUND: The strategy for mitral valve (MV) repair has recently focused on the restoration of the submitral apparatus. However, the relationship between geometric changes of the submitral apparatus and the mitral leaflets has not been systematically investigated. The aim of this study was to determine the relationships among chordal length (CL) and LV size and leaflet surface area (LSA) in normal subjects, patients with primary (degenerative) mitral regurgitation (PMR), and patients with functional (secondary) mitral regurgitation (FMR). METHODS: A total of 72 patients who underwent three-dimensional transesophageal echocardiography, including: 27 with PMR with isolated P2 flail leaflet, 25 with FMR with greater than mild mitral regurgitation, and 20 with normal mitral valves. LSA was quantified at midsystole from full-volume midesophageal views. CL was calculated by averaging the lengths of eight primary chords from transgastric full-volume data sets using multiplanar reconstruction. RESULTS: Both CL and LSA in the PMR group were significantly longer compared with the FMR and normal control groups. No difference in CL was noted between patients with FMR and normal subjects. In all three groups, CL and LSA did not correlate with LV systolic or diastolic dimensions. Although CL did not correlate with LSA in the FMR group, a moderate correlation (R = 0.62) was observed in the PMR group. CONCLUSIONS: In patients with FMR with greater than mild mitral regurgitation, the chords retain normal length, despite LSA and LV enlargement. In patients with PMR with flail P2 scallops, CL elongation of primary chords is associated with larger LSA but not with LV dimensions. This information may have implications for clinical strategies for mitral valve repair surgery, including the submitral approach and percutaneous procedures.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Cordas Tendinosas/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA