Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Rep Pract Oncol Radiother ; 28(3): 416-428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37795396

RESUMO

Background: The aim of this study was to indicate the most favorable - in terms of to the time of calculation and the uncertainty of determining the dose distribution - values of the parameters for the Electron Monte Carlo (eMC) algorithm in the Eclipse treatment planning system. Materials and methods: Using the eMC algorithm and the variability of the values of its individual parameters, calculations of the electron dose distribution in the full-scattering virtual water phantom were performed, obtaining percentage depth doses, beam profiles, absolute dose values in points and calculation times. The reference data included water tank measurements such as relative dose distributions and absolute point doses. Results: For 63 sets of calculation data created from selected values of the parameters for the eMC algorithm, calculation times were analyzed and the absolute calculated and measured doses were compared. Performing a statistical analysis made it possible to determine whether the differences in the values of deviations between the actual dose and the calculated dose in individual regions of the percentage depth dose curve and the beam profile are statistically significant between the analyzed sets of parameters. Conclusions: Taking into account obtained results from the analysis of the discrepancy between the distribution of the calculated and measured dose, the correspondence of the absolute value of the calculated and measured dose and the duration of the calculation of the dose distribution, the optimal set of parameters was indicated for the eMC algorithm which allows obtaining the dose distribution and the number of monitor units in an acceptable time.

2.
Rep Pract Oncol Radiother ; 27(2): 241-249, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36299384

RESUMO

Background: To properly configure a treatment planning system, a measurement data set is needed, which consists of the values required for its configuration. The aim is to obtain a dosimetric model of the beam that is as compatible as possible with the measured values. The set of required data can be supplemented with optional values. The aim of the study was to assess the influence of optional measurement data on the compliance of the calculations with the measurements. Materials and methods: Dosimetric measurements, model configuration and dose distribution calculations were performed for the photon radiation beams generated by the VMS TrueBeam® linear accelerator. Beams were configured on an Eclipse™ v. 15.6 system using the Acuros v. 15.6 algorithm. The measured and calculated data were entered into the Alfard™ software for comparison with the calculated dose distributions. In the last stage, the absolute dose values at the designated points were also compared. The obtained data were statistically analysed with Statistica™ v. 13.3. Results: The work showed that the differences in the shape of the beam profile, depth dose and the dose value in points were not related to the use of optional data. Differences in dose distributions are within the tolerance. It cannot be determined under which conditions the use of optional data has a more favourable effect on the reflection of the actual dose values. Conclusions: The use of optional data in modelling photon radiation beams does not significantly improve the compliance of the calculated and measured dose values.

3.
Rep Pract Oncol Radiother ; 26(4): 553-562, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434571

RESUMO

BACKGROUND: The comparison between profiles during the commissioning of the treatment planning system is an essential procedure. It is impossible to designate a field size for off-axis, wedged, and FFF beams directly by using the definition of the on-axis symmetric field size. This work proposes the use of different characteristic points as indicators of the field size for commissioning and QA purposes. This work aimed to search for the beam profile's characteristic points and use them for the TPS commissioning purposes. MATERIALS AND METHODS: The proposal is to use profile inflection points as the beam profile characteristic points. The usage of dedicated software allowed for comparing distances between inflection points and between points of 50% intensity. For the off-axis, wedged, and FFF fields, comparisons were made to the nominal field sizes. RESULTS: Distances between inflection points proved to be different by less than 1 mm from nominal field sizes for all kinds of investigated beams. CONCLUSIONS: Inflection points are convenient for comparing the off-axis, wedged, and FFF field sizes because of their independence from profile normalization. With finite accuracy, the inflection points could be used for the above kind of beam sizes designation.

4.
Int J Mol Sci ; 22(12)2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34208417

RESUMO

In the present study, we analyze the nuclear magnetic resonance (NMR) blood serum metabolic profiles of 106 head and neck squamous cell carcinoma (HNSCC) patients during radio (RT) and concurrent radio-chemotherapy (CHRT). Four different fractionation schemes were compared. The blood samples were collected weekly, from the day before the treatment until the last week of CHRT/RT. The NMR spectra were acquired on A Bruker 400 MHz spectrometer at 310 K and analyzed using multivariate methods. Seven metabolites were found significantly to be altered solely by radiotherapy: N-acetyl-glycoprotein (NAG), N-acetylcysteine, glycerol, glycolate and the lipids at 0.9, 1.3 and 3.2 ppm. The NMR results were correlated with the tissue volumes receiving a particular dose of radiation. The influence of the irradiated volume on the metabolic profile is weak and mainly limited to sparse correlations with the inflammatory markers, creatinine and the lymphocyte count in RT and the branched-chain amino-acids in CHRT. This is probably due to the optimal planning and delivery of radiotherapy improving sparing of the surrounding normal tissues and minimizing the differences between the patients (caused by the tumor location and size).


Assuntos
Neoplasias de Cabeça e Pescoço/sangue , Neoplasias de Cabeça e Pescoço/radioterapia , Espectroscopia de Ressonância Magnética , Metabolômica , Dosagem Radioterapêutica , Adulto , Idoso , Análise Discriminante , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Feminino , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
5.
J Appl Clin Med Phys ; 22(1): 156-164, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33314643

RESUMO

The accuracy of radiotherapy is the subject of continuous discussion, and dosimetry methods, particularly in dynamic techniques, are being developed. At the same time, many oncology centers develop quality procedures, including pretreatment and online dose verification and proper patient tracking methods. This work aims to present the possibility of using portal dosimetry in the assessment of radiotherapy repeatability. The analysis was conducted on 74 cases treated with dynamic techniques. Transit dosimetry was made for each collision-free radiation beam. It allowed the comparison of summary fluence maps, obtained for fractions with the corresponding summary maps from all other treatment fractions. For evaluation of the compatibility in the fluence map pairs (6798), the gamma coefficient was calculated. The results were considered in four groups, depending on the used radiotherapy technique: stereotactic fractionated radiotherapy, breath-hold, free-breathing, and conventionally fractionated other cases. The chi2 or Fisher's exact test was made depending on the size of the analyzed set and also Mann-Whitney U-test was used to compare treatment repeatability of different techniques. The aim was to test whether the null hypothesis of error-free therapy was met. The patient is treated repeatedly if the P-value in all the fluence maps sets is higher than the level of 0.01. The best compatibility between treatment fractions was obtained for the stereotactic technique. The technique with breath-holding gave the lowest percentage of compliance of the analyzed fluence pairs. The results indicate that the repeatability of the treatment is associated with the radiotherapy technique. Treated volume location is also an essential factor found in the evaluation of treatment accuracy. The EPID device is a useful tool in assessing the repeatability of radiotherapy. The proposed method of fluence maps comparison also allows us to assess in which therapeutic session the patient was treated differently from the other fractions.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
6.
Rep Pract Oncol Radiother ; 24(1): 20-27, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30337844

RESUMO

AIM: The aim of this study is to answer the question whether the calculated dose distributions for HD and Millennium collimators (Varian Medical Systems) are equivalent for large treatment volumes. BACKGROUND: Modern biomedical linacs are equipped with multileaf collimators where leaves can be of different widths. Thinner leaves allow better fit to desired (tumor) shape. At the same time, however, the maximum size of the field that can be obtained with the collimator is also reduced. Varian Medical Systems HD and Millennium collimators can be a good sample. They have 40 cm or 22 cm × 40 cm maximal field size at the isocenter, respectively. MATERIALS AND METHODS: This paper presents the comparison of selected statistical and dosimetric parameters achieved for treatment plans where the beams for a HD collimator had to be merged because of the size of the tumor volume. RESULTS AND DISCUSSION: Achieved results show that, independently from irradiated volume, there is no statistically significant difference for calculated dose distributions, integral doses, MU values and coefficients evaluating dose distributions for HD and Millennium collimators. CONCLUSIONS: Results show that both types of collimators can be used interchangeably for preparing the treatment plans for large tumor volume without quality reduction of the prepared treatment plan.

7.
Radiat Oncol ; 13(1): 41, 2018 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-29544504

RESUMO

BACKGROUND: To appraise the dosimetric features and the quality of the treatment plan for radiosurgery of multiple brain metastases optimized with a novel automated engine and to compare with plans optimized for robotic-based delivery. METHODS: A set of 15 patients with multiple brain metastases was selected for this in silico study. The technique under investigation is the recently introduced HyperArc. For all patients, three treatment plans were computed and compared: i: a HyperArc; ii: a standard VMAT; iii) a CyberKnife. Dosimetric features were computed for the clinical target volumes as well as for the healthy brain tissue and the organs at risk. RESULTS: The data showed that the best dose homogeneity was achieved with the VMAT technique. HyperArc allowed to minimize the volume of brain receiving 4Gy (as well as for the mean dose and the volume receiving 12Gy, although not statistically significant). The smallest dose on 1 cm3 volume for all organs at risk is for CK techniques, and the biggest for VMAT (p < 0.05). The Radiation Planning Index coefficient indicates that, there are no significant differences among the techniques investigated, suggesting an equivalence among these. CONCLUSION: At treatment planning level, the study demonstrates that the use of HyperArc technique can significantly improve the sparing of the healthy brain while maintaining a full coverage of the target volumes.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/secundário , Humanos , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos , Robótica
8.
Rep Pract Oncol Radiother ; 21(3): 168-73, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27601946

RESUMO

AIM: This work addresses the problem of treatment planning system commissioning by introducing a new method of determination of boundaries between high and low gradient in beam profile. BACKGROUND: The commissioning of a treatment planning system is a very important task in the radiation therapy. One of the main goals of this task is to compare two field profiles: measured and calculated. Applying points of 80% and 120% of nominal field size can lead to the incorrect determination of boundaries, especially for small field sizes. MATERIALS AND METHODS: The method that is based on the beam profile gradient allows for proper assignment of boundaries between high and low gradient regions even for small fields. TRS 430 recommendations for commissioning were used. RESULTS: The described method allows a separation between high and low gradient, because it directly uses the value of the gradient of a profile. For small fields, the boundaries determined by the new method allow a commissioning of a treatment planning system according to the TRS 430, while the point of 80% of nominal field size is already in the high gradient region. CONCLUSIONS: The method of determining the boundaries by using the beam profile gradient can be extremely helpful during the commissioning of the treatment planning system for Intensity Modulated Radiation Therapy or for other techniques which require very small field sizes.

9.
Phys Rev E Stat Nonlin Soft Matter Phys ; 86(4 Pt 1): 041138, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23214560

RESUMO

We examine the critical behavior of a lattice model of tumor growth where supplied nutrients are correlated with the distribution of tumor cells. Our results support the previous report [Ferreira et al., Phys. Rev. E 85, 010901(R) (2012)], which suggested that the critical behavior of the model differs from the expected directed percolation (DP) universality class. Surprisingly, only some of the critical exponents (ß, α, ν([perpendicular]), and z) take non-DP values while some others (ß', ν(||), and spreading-dynamics exponents Θ, δ, z') remain very close to their DP counterparts. The obtained exponents satisfy the scaling relations ß=αν(||), ß'=δν(||), and the generalized hyperscaling relation Θ+α+δ=d/z, where the dynamical exponent z is, however, used instead of the spreading exponent z'. Both in d=1 and d=2 versions of our model, the exponent ß most likely takes the mean-field value ß=1, and we speculate that it might be due to the roulette-wheel selection, which is used to choose the site to supply a nutrient.


Assuntos
Biofísica/métodos , Neoplasias/metabolismo , Algoritmos , Vasos Sanguíneos/patologia , Proliferação de Células , Simulação por Computador , Difusão , Humanos , Modelos Biológicos , Modelos Teóricos , Método de Monte Carlo , Neovascularização Patológica , Probabilidade , Fatores de Tempo
10.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(3 Pt 1): 031904, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21517522

RESUMO

In the present paper we study a lattice model of two species competing for the same resources. Monte Carlo simulations for d = 1,2, and 3 show that when resources are easily available both species coexist. However, when the supply of resources is on an intermediate level, the species with slower metabolism becomes extinct. On the other hand, when resources are scarce it is the species with faster metabolism that becomes extinct. The range of coexistence of the two species increases with dimension. We suggest that our model might describe some aspects of the competition between normal and tumor cells. With such an interpretation, examples of tumor remission, recurrence, and different morphologies are presented. In the d = 1 and d = 2 models, we analyze the nature of phase transitions: they are either discontinuous or belong to the directed-percolation universality class, and in some cases they have an active subcritical phase. In the d = 2 case, one of the transitions seems to be characterized by critical exponents that differ from directed-percolation ones, but this transition could be also weakly discontinuous. In the d = 3 version, Monte Carlo simulations are in a good agreement with the solution of the mean-field approximation. This approximation predicts that oscillatory behavior occurs in the present model but only for d ≳ 2. For d ≥ 2, a steady state depends on the initial configuration in some cases.


Assuntos
Neoplasias/patologia , Animais , Linhagem Celular Tumoral , Simulação por Computador , Humanos , Modelos Biológicos , Modelos Estatísticos , Método de Monte Carlo , Oscilometria/métodos , Transição de Fase , Probabilidade , Software , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA