Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Br J Haematol ; 200(6): 792-801, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36444397

RESUMO

The diagnostic work-up of patients referred to the haematologist for bleeding evaluation is performed in a stepwise way: bleeding history and results of screening laboratory tests guide further diagnostic evaluation. This can be ineffective, time-consuming and burdensome for patients. To improve this strategy, the initial laboratory investigation can be extended. In a model-based approach, effectiveness and costs of a conventional stepwise versus a newly proposed all-in-one diagnostic approach for bleeding evaluation were evaluated and compared, using data from an observational patient cohort study, including adult patients referred for bleeding evaluation. In the all-in-one approach, specialized platelet function tests, coagulation factors, and fibrinolysis tests were included in the initial investigation. Final diagnosis, hospital resource use and costs and patient burden were compared. A total of 150 patients were included. Compared to the stepwise approach, in the all-in-one approach, 19 additional patients reached a diagnosis and patient burden was lower, but total costs per patient were higher [€359, 95% bootstrapped confidence interval (BCI) 283-518, p = 0.001]. For bleeding evaluation of patients referred to the haematologist, an all-in-one diagnostic approach has a higher diagnostic yield and reduces patient burden, at a higher cost. This raises the question what costs justify the diagnosis of a bleeding disorder and a less burdensome diagnostic strategy.


Assuntos
Transtornos da Coagulação Sanguínea , Transtornos Hemorrágicos , Adulto , Humanos , Transtornos da Coagulação Sanguínea/diagnóstico , Transtornos Hemorrágicos/diagnóstico , Hemorragia , Fibrinólise , Análise Custo-Benefício
2.
Br J Haematol ; 196(6): 1388-1400, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35001370

RESUMO

Patients referred for evaluation of bleeding symptoms occasionally have a prolonged platelet function analyser (PFA) closure time, without evidence for von Willebrand disease or impaired platelet aggregation. The aim of this study was to establish a shear-dependent platelet function defect in these patients. Patients were included based on high bleeding score and prior PFA prolongation. Common tests of von Willebrand factor (VWF) and platelet function and exome sequencing were performed. Microfluidic analysis of shear-dependent collagen-induced whole-blood thrombus formation was performed. In 14 PFA-only patients, compared to healthy volunteers, microfluidic tests showed significantly lower platelet adhesion and thrombus formation parameters. This was accompanied by lower integrin activation, phosphatidylserine exposure and P-selectin expression. Principal components analysis indicated VWF as primary explaining variable of PFA prolongation, whereas conventional platelet aggregation primarily explained the reduced thrombus parameters under shear. In five patients with severe microfluidic abnormalities, conventional platelet aggregation was in the lowest range of normal. No causal variants in Mendelian genes known to cause bleeding or platelet disorders were identified. Multiparameter assessment of whole-blood thrombus formation under shear indicates single or combined effects of low-normal VWF and low-normal platelet aggregation in these patients, suggesting a shear-dependent platelet function defect, not detected by static conventional haemostatic tests.


Assuntos
Trombose , Doenças de von Willebrand , Plaquetas/metabolismo , Hemorragia , Hemostasia , Humanos , Agregação Plaquetária , Testes de Função Plaquetária , Fator de von Willebrand/genética , Fator de von Willebrand/metabolismo
3.
TH Open ; 4(4): e365-e375, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33235946

RESUMO

Objective Severe cases of coronavirus disease 2019 (COVID-19) can require continuous renal replacement therapy (CRRT) and/or extracorporeal membrane oxygenation (ECMO). Unfractionated heparin (UFH) to prevent circuit clotting is mandatory but monitoring is complicated by (pseudo)-heparin resistance. In this observational study, we compared two different activated partial thromboplastin time (aPTT) assays and a chromogenic anti-Xa assay in COVID-19 patients on CRRT or ECMO in relation to their UFH dosages and acute phase reactants. Materials and Methods The aPTT (optical [aPTT-CS] and/or mechanical [aPTT-STA] clot detection methods were used), anti-Xa, factor VIII (FVIII), antithrombin III (ATIII), and fibrinogen were measured in 342 samples from 7 COVID-19 patients on CRRT or ECMO during their UFH treatment. Dosage of UFH was primarily based on the aPTT-CS with a heparin therapeutic range (HTR) of 50-80s. Associations between different variables were made using linear regression and Bland-Altman analysis. Results Dosage of UFH was above 35,000IU/24 hours in all patients. aPTT-CS and aPTT-STA were predominantly within the HTR. Anti-Xa was predominantly above the HTR (0.3-0.7 IU/mL) and ATIII concentration was >70% for all patients; mean FVIII and fibrinogen were 606% and 7.5 g/L, respectively. aPTT-CS correlated with aPTT-STA ( r 2 = 0.68) with a bias of 39.3%. Correlation between aPTT and anti-Xa was better for aPTT-CS (0.78 ≤ r 2 ≤ 0.94) than for aPTT-STA (0.34 ≤ r 2 ≤ 0.81). There was no general correlation between the aPTT-CS and ATIII, FVIII, fibrinogen, thrombocytes, C-reactive protein, or ferritin. Conclusion All included COVID-19 patients on CRRT or ECMO conformed to the definition of heparin resistance. A patient-specific association was found between aPTT and anti-Xa. This association could not be explained by FVIII or fibrinogen.

4.
J Thromb Haemost ; 17(7): 1073-1084, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31033178

RESUMO

Essentials Bleeding in chemotherapy induced thrombocytopenia (CIT) might be influenced by hyperfibrinolysis. t-PA-thromboelastography is a fast and reliable assay for hyperfibrinolysis in CIT patients. Clots of CIT patients are more susceptible to t-PA induced lysis compared to healthy individuals. Besides platelets, other factors are likely to influence clot lysis in CIT patients. BACKGROUND: Bleeding events in chemotherapy-induced thrombocytopenic (CIT) patients with similar platelet counts might be influenced by changes in clot lysis potential. OBJECTIVES: To investigate, in an observational study, thromboelastographic lysis parameters, alterations in clot strength and susceptibility to clot lysis in CIT patients. To identify factors associated with fibrinolytic profiles, and to evaluate the effects of platelet transfusions. METHODS: Independent determinants of tissue-type plasminogen activator (t-PA)-ROTEM lysis parameters were identified with multivariable linear regression. Clot formation, strength and lysis parameters were compared with the results of healthy individuals. Characteristics of CIT patients with and without hyperfibrinolytic profiles were compared. t-PA-ROTEM results before, 1 hour after and 24 hours after platelet transfusion were compared. RESULTS: A total of 72 consecutive CIT patients were included. t-PA-ROTEM lysis parameters correlated with changes in fibrinolytic proteins. Clot formation time was longer, maximum clot firmness was weaker and lysis times were shorter than in healthy individuals. CIT patients had low plasminogen activator inhibitor-1 and thrombin-activatable fibrinolysis inhibitor levels, and 40% showed hyperfibrinolytic profiles. Platelet transfusions resulted in less hyperfibrinolytic profiles in many, but not all CIT patients. Patients without hyperfibrinolytic profiles had higher fibrinogen, factor VIII and α2 -antiplasmin levels. CONCLUSIONS: t-PA-ROTEM can be used as a fast and reliable assay to detect hyperfibrinolytic profiles in CIT patients. CIT patients have weaker clots, which are more susceptible to clot lysis, than healthy individuals. Besides platelets, other factors are likely to influence clot susceptibility to fibrinolysis in CIT patients. The impact of a hyperfibrinolytic t-PA-ROTEM profile on bleeding remains to be investigated.


Assuntos
Antineoplásicos/efeitos adversos , Fibrinólise/efeitos dos fármacos , Hemorragia/induzido quimicamente , Hemorragia/terapia , Transfusão de Plaquetas , Trombocitopenia/induzido quimicamente , Trombocitopenia/terapia , Idoso , Biomarcadores/sangue , Carboxipeptidase B2/sangue , Fator VIII/metabolismo , Feminino , Fibrinogênio/metabolismo , Hemorragia/sangue , Hemorragia/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Inibidor 1 de Ativador de Plasminogênio/sangue , Transfusão de Plaquetas/efeitos adversos , Estudos Prospectivos , Tromboelastografia , Trombocitopenia/sangue , Trombocitopenia/diagnóstico , Fatores de Tempo , Ativador de Plasminogênio Tecidual/metabolismo , Resultado do Tratamento , alfa 2-Antiplasmina/metabolismo
5.
Platelets ; 30(1): 81-87, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29135309

RESUMO

Light transmission aggregation (LTA) is the gold standard for the diagnosis of platelet function disorders (PFDs), but it is time-consuming and limited to specialized laboratories. Whole-blood impedance aggregometry (Multiplate) and platelet function analyzer (PFA) may be used as rapid screening tools to exclude PFDs. The aim of this study is to assess the diagnostic performance of Multiplate and PFA for PFDs, as detected by LTA.Data from preoperative patients, patients referred to the hematologist for bleeding evaluation, and patients with a diagnosed bleeding disorder were used. PFDs were defined as ≥2 abnormal LTA curves. Diagnostic performance of Multiplate and PFA for detecting PFDs was expressed as sensitivity and specificity. The ability of Multiplate agonists and PFA kits to detect corresponding LTA curve abnormalities was expressed as area under the receiver operating characteristic curve. Prevalence of PFDs was 16/335 (4.8%) in preoperative patients, 10/54 (18.5%) in referred patients, and 3/25 (12%) in patients with a diagnosed bleeding disorder. In preoperative and referred patients, the sensitivity of Multiplate and PFA for detecting mild PFDs varied between 0% and 40% and AUCs for detecting corresponding LTA curve abnormalities were close to 0.50. In patients with a diagnosed bleeding disorder, both assays could detect Glanzmann thrombasthenia (GT) with sensitivity of 100% and AUCs of 0.70-1.00. Multiplate and PFA cannot discriminate between preoperative and referred patients with and without mild PFDs, meaning that they cannot be used as screening tests to rule out mild PFDs in these populations. Both Multiplate and PFA can detect GT in previously diagnosed patients.


Assuntos
Transtornos Plaquetários/sangue , Transtornos Plaquetários/diagnóstico , Plaquetas/metabolismo , Adulto , Idoso , Transtornos Plaquetários/terapia , Plaquetas/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária , Testes de Função Plaquetária , Reprodutibilidade dos Testes
6.
Thromb Res ; 174: 88-94, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30579151

RESUMO

Enhanced clot lysis is associated with bleeding, but assessment of lysis capacity remains difficult. The plasma turbidity lysis and whole blood tissue Plasminogen Activator-Rotational Thromboelastometry (tPA-ROTEM) assays estimate fibrinolysis under more physiological conditions than clinically used assays. We hypothesized that these assays could find signs of enhanced lysis capacity in patients who report bleeding symptoms, but are not diagnosed with bleeding disorders. We also aimed to gain insight in determinants of the results of these lysis assays. Data from 240 patients with and 95 patients without self-reported bleeding symptoms were obtained, who were included in a study that primarily aimed to assess prevalence of haemostatic abnormalities in preoperative patients. ROTEM and turbidity assays were performed with rtPA. Blood counts, fibrinolysis and coagulation factor activities were determined. Data were analysed using multivariable linear regression models. Remarkably, patients reporting bleeding symptoms showed signs of significantly impaired lysis capacity in the tPA-ROTEM, but not in the turbidity lysis assay. In these patients, the tPA-ROTEM results depended on FII, FXII, plasminogen, α2-antiplasmin, PAI-1 and TAFI levels. The turbidity lysis results were significantly influenced by fibrinogen, α2-antiplasmin, PAI-1 and TAFI. In conclusion, the tPA-ROTEM and the turbidity lysis assay could not detect enhanced fibrinolytic capacity in patients with bleeding symptoms. This suggests that these symptoms are not caused by enhanced fibrinolytic activity. As both assays were sensitive to important determinants of fibrinolysis they may be able to detect a fibrinolytic imbalance, but this needs to be validated in patients with known hypo- or hyperfibrinolytic disorders.


Assuntos
Fibrinólise/fisiologia , Hemorragia/sangue , Tromboelastografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Haematologica ; 103(9): 1557-1567, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29880611

RESUMO

Severe thrombocytopenia (≤50×109 platelets/L) due to hematological malignancy and intensive chemotherapy is associated with an increased risk of clinically significant bleeding. Since the bleeding risk is not linked to the platelet count only, other hemostatic factors must be involved. We studied platelet function in 77 patients with acute leukemia, multiple myeloma or malignant lymphoma, who experienced chemotherapy-induced thrombocytopenia. Platelets from all patients - independent of disease or treatment type - were to a variable extent compromised in Ca2+ flux, integrin a ß activation and P-selectin expression when stimulated with a panelIIbof3 agonists. The patients' platelets were also impaired in spreading on fibrinogen. Whereas the Ca2+ store content was unaffected, the patients' platelets showed ongoing phosphatidylserine exposure, which was not due to apoptotic caspase activity. Interestingly, mitochondrial function was markedly reduced in platelets from a representative subset of patients, as evidenced by a low mitochondrial membrane potential (P<0.001) and low oxygen consumption (P<0.05), while the mitochondrial content was normal. Moreover, the mitochondrial impairments coincided with elevated levels of reactive oxygen species (Spearman's rho=-0.459, P=0.012). Markedly, the impairment of platelet function only appeared after two days of chemotherapy, suggesting origination in the megakaryocytes. In patients with bone marrow recovery, platelet function improved. In conclusion, our findings disclose defective receptor signaling related to impaired mitochondrial bioenergetics, independent of apoptosis, in platelets from cancer patients treated with chemotherapy, explaining the low hemostatic potential of these patients.


Assuntos
Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Neoplasias/complicações , Trombocitopenia/etiologia , Trombocitopenia/metabolismo , Adulto , Idoso , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Apoptose/efeitos dos fármacos , Biomarcadores , Coagulação Sanguínea/efeitos dos fármacos , Sinalização do Cálcio/efeitos dos fármacos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/sangue , Neoplasias/tratamento farmacológico , Ativação Plaquetária/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Contagem de Plaquetas , Testes de Função Plaquetária , Índice de Gravidade de Doença , Trombocitopenia/sangue , Trombocitopenia/diagnóstico
8.
Platelets ; 28(7): 668-675, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28067094

RESUMO

Low platelet counts and hematocrit levels hinder whole blood point-of-care testing of platelet function. Thus far, no reference ranges for MEA (multiple electrode aggregometry) and PFA-100 (platelet function analyzer 100) devices exist for low ranges. Through dilution methods of volunteer whole blood, platelet function at low ranges of platelet count and hematocrit levels was assessed on MEA for four agonists and for PFA-100 in two cartridges. Using (multiple) regression analysis, 95% reference intervals were computed for these low ranges. Low platelet counts affected MEA in a positive correlation (all agonists showed r2 ≥ 0.75) and PFA-100 in an inverse correlation (closure times were prolonged with lower platelet counts). Lowered hematocrit did not affect MEA testing, except for arachidonic acid activation (ASPI), which showed a weak positive correlation (r2 = 0.14). Closure time on PFA-100 testing was inversely correlated with hematocrit for both cartridges. Regression analysis revealed different 95% reference intervals in comparison with originally established intervals for both MEA and PFA-100 in low platelet or hematocrit conditions. Multiple regression analysis of ASPI and both tests on the PFA-100 for combined low platelet and hematocrit conditions revealed that only PFA-100 testing should be adjusted for both thrombocytopenia and anemia. 95% reference intervals were calculated using multiple regression analysis. However, coefficients of determination of PFA-100 were poor, and some variance remained unexplained. Thus, in this pilot study using (multiple) regression analysis, we could establish reference intervals of platelet function in anemia and thrombocytopenia conditions on PFA-100 and in thrombocytopenia conditions on MEA.


Assuntos
Anemia/diagnóstico , Automação Laboratorial/normas , Plaquetas/patologia , Testes Imediatos/normas , Trombocitopenia/diagnóstico , Difosfato de Adenosina/farmacologia , Adolescente , Adulto , Anemia/sangue , Anemia/patologia , Ácido Araquidônico/farmacologia , Automação Laboratorial/instrumentação , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Estudos de Casos e Controles , Colágeno/farmacologia , Feminino , Hematócrito , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Agregação Plaquetária/efeitos dos fármacos , Testes de Função Plaquetária/normas , Receptores de Trombina/química , Valores de Referência , Análise de Regressão , Trombocitopenia/sangue , Trombocitopenia/patologia
9.
J Cardiothorac Vasc Anesth ; 28(2): 210-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24630470

RESUMO

OBJECTIVES: In the present study, the authors have investigated whether rotational thromboelastometry (ROTEM) could predict thrombocytopenia and hypofibrinogenemia in cardiac surgery using the clot amplitude after 5 minutes (A5). Another parameter, PLTEM, in which the contribution of fibrinogen is eliminated by subtracting a fibrin-specific ROTEM test (FIBTEM) from an extrinsically-activated ROTEM test (EXTEM), was investigated. Furthermore, the turnaround time of ROTEM was compared to conventional laboratory tests. DESIGN: Prospective cohort study. SETTING: Single academic medical center. PARTICIPANTS: Ninety-seven patients undergoing cardiac surgery between July 2011 until August 2012. INTERVENTIONS: The correlations between EXTEM/FIBTEM A5, A10, and maximal clot formation (MCF), EXTEM/PLTEM (A5/A10, and MCF) and platelet count, and FIBTEM (A5/A10, and MCF) and fibrinogen were evaluated using the Pearson's correlation coefficient and receiver-operating characteristic curves. Turnaround times of ROTEM tests and conventional laboratory tests were assessed in the central laboratory. MEASUREMENTS AND MAIN RESULTS: EXTEM A5 and FIBTEM A5 showed an excellent correlation with A10 (R:0.99/1.00) and MCF (R:0.97/0.99). The correlation between EXTEM A5 and platelet count (R:0.74) was comparable with the correlation of A10 (R:0.73) and MCF (R:0.70) with platelet count. FIBTEM A5 predicted fibrinogen levels (R:0.87) as well as A10 (R:0.86) and MCF (R:0.87). PLTEM A5 (R:0.85) correlated better with platelet count than EXTEM A5 (R:0.74; p = 0.04) and showed significantly better area under the curve values than EXTEM for predicting thrombocytopenia (A5 p = 0.012, A10 p = 0.019). Turnaround time for ROTEM tests, 12 minutes, was comparable with emergency requests for platelet count, 13 minutes, and shorter than emergency requests for fibrinogen levels, 37 minutes. CONCLUSIONS: Implementation of PLTEM and FIBTEM A5 in ROTEM-guided transfusion protocols may improve transfusion management.


Assuntos
Afibrinogenemia/diagnóstico , Procedimentos Cirúrgicos Cardíacos/métodos , Tromboelastografia/métodos , Trombocitopenia/diagnóstico , Idoso , Área Sob a Curva , Transtornos da Coagulação Sanguínea/sangue , Transtornos da Coagulação Sanguínea/diagnóstico , Transfusão de Sangue/métodos , Estudos de Coortes , Feminino , Hemoglobinas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Trombocitopenia/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA