Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 315
Filtrar
1.
ASAIO J ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38569184

RESUMO

Severe right heart failure, often overlooked and challenging to manage, has prompted a growing interest in innovative approaches to provide functional support. This study uses experimentation in large porcine models to introduce a novel prototype of a pulsatile mechanical circulatory support device and document its effects when deployed as a right ventricular assist device (RVAD). The pulsatile ventricular assist platform (pVAP), featuring a membrane pump driven by an intra-aortic balloon pump console, actively generates pulsatile flow to propel right ventricular blood into the pulmonary artery. This novel prototype demonstrates promising potential in addressing the challenges of right heart failure management. After preliminary in vitro assessments, the pVAP was tested on seven porcine models in a healthy state and after the induction of right ventricular failure. During the procedure, a set of standard (ie, standard-of-care) hemodynamic measurements was obtained. Additionally, invasive pressure-volume loop analysis was employed to examine left ventricular hemodynamics. Results indicated that activation of the pVAP during right ventricular failure significantly improved systemic hemodynamics and enhanced left ventricular function. This study sheds light on the potential of the pVAP in managing right heart failure.

3.
Innovations (Phila) ; 19(2): 196-203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38576096

RESUMO

In the evolving landscape of cardiac surgery, this article explores the potential of minimally invasive mitral valve replacement procedures as a viable alternative to conventional surgical techniques. Leveraging advancements in automated suturing devices and video endoscopy, our work aims to demonstrate that minimally invasive approaches can be applied across a broad spectrum of surgical scenarios. Herein we highlight preoperative diagnostics and operative techniques, with a focus on infra-axillary anterolateral minithoracotomy as the access point. Our technique utilizes technology from LSI SOLUTIONS® (Victor, NY, USA), including the RAM® Device for automated suturing, which has an ergonomic design and safety features. The device's capabilities are further enhanced by the SEW-EASY® Device, the RAM® RING, and the COR-KNOT MINI® Device, which streamline suture management and securement. This work outlines how these technological advancements can mitigate concerns about technical complexity and learning curves, thereby encouraging wider adoption of minimally invasive techniques. Clinical benefits may include reduced surgical trauma, quicker recovery, and cost-effectiveness, making it a compelling option in an era of aggressively promoted transcatheter interventions.


Assuntos
Endoscopia , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Minimamente Invasivos , Valva Mitral , Técnicas de Sutura , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Técnicas de Sutura/instrumentação , Endoscopia/métodos , Endoscopia/instrumentação , Toracotomia/métodos
4.
Diagnostics (Basel) ; 14(5)2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38472937

RESUMO

Infective endocarditis (IE) is a severe cardiac complication with high mortality rates, especially when surgical intervention is delayed or absent. This review addresses the expanding role of surgery in managing IE, focusing on the variation in surgical treatment rates, the impact of patient demographics, and the effectiveness of different surgical approaches. Despite varying global data, a notable increase in surgical interventions for IE is evident, with over 50% of patients undergoing surgery in tertiary centres. This review synthesizes information from focused literature searches up to July 2023, covering preoperative to postoperative considerations and surgical strategies for IE. Key preoperative concerns include accurate diagnosis, appropriate antimicrobial treatment, and the timing of surgery, which is particularly crucial for patients with heart failure or at risk of embolism. Surgical approaches vary based on valve involvement, with mitral valve repair showing promising outcomes compared to replacement. Aortic valve surgery, traditionally favouring replacement, now includes repair as a viable option. Emerging techniques such as sutureless valves and aortic homografts are explored, highlighting their potential advantages in specific IE cases. The review also delves into high-risk groups like intravenous drug users and the elderly, emphasizing the need for tailored surgical strategies. With an increasing number of patients presenting with prosthetic valve endocarditis and device-related IE, the review underscores the importance of comprehensive management strategies encompassing surgical and medical interventions. Overall, this review provides a comprehensive overview of current evidence in the surgical management of IE, highlighting the necessity of a multidisciplinary approach and ongoing research to optimize patient outcomes.

5.
Front Cardiovasc Med ; 11: 1344292, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545343

RESUMO

Intraluminal thrombus formation (ILT) is a recently discovered and highly clinically relevant complication after frozen elephant trunk implantation in cardiovascular surgery. In this phenomenon, a thrombus forms within the lumen of the stent graft component of the frozen elephant trunk prosthesis and puts the patient at risk for downstream embolization with visceral or lower limb ischemia. Incidence of ILT reported in the currently available studies ranges from 6% to 17% of patients after frozen elephant trunk implantation. Adverse thromboembolic events include acute occlusion of the celiac and superior mesenteric arteries, both renal arteries as well as acute lower limb ischemia due to iliac or femoral artery embolization that not infrequently require interventional or open embolectomy. Therefore, the presence of ILT is associated with increased short-term mortality and morbidity. Currently proposed strategies to avoid ILT formation include a more aggressive anticoagulation management, minimization of postoperative coagulation factor application, and even technical optimizations of the stent graft portion itself. If ILT is manifested, the therapeutic strategies tested to date are long-term escalation of anticoagulation and early endovascular extension of the FET stent graft with overstenting of the intraluminal thrombus. The long-term efficiency of these prophylactic and therapeutic measures has yet to be proven. Nonetheless, all surgeons performing the frozen elephant trunk procedure must be aware of the risk of ILT formation to facilitate a timely diagnosis and therapy.

6.
J Clin Med ; 13(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38337526

RESUMO

BACKGROUND: Intercostal artery reinsertion (ICAR) during thoracoabdominal aortic replacement remains controversial. While some groups recommend the reinsertion of as many arteries as possible, others consider the sacrifice of multiple intercostals practicable. This study investigates the impact of intercostal artery reinsertion or sacrifice on neurological outcomes and long-term survival after thoracoabdominal aortic repair. METHODS: A total of 349 consecutive patients undergoing thoracoabdominal aortic replacement at our institution between 1996 and 2021 were analyzed in a retrospective single-center study. ICAR was performed in 213 patients, while all intercostal arteries were ligated and sacrificed in the remaining cases. The neurological outcome was analyzed regarding temporary and permanent paraplegia or paraparesis. RESULTS: No statistically significant differences were observed between the ICAR and non ICAR groups regarding the cumulative endpoint of transient and permanent spinal cord-related complications (12.2% vs. 11.8%, p = 0.9). Operation, bypass, and cross-clamp times were significantly longer in the ICAR group. Likewise, prolonged mechanical ventilation was more often necessary in the ICAR group (26.4% vs. 16.9%, p = 0.03). Overall long-term survival was similar in both groups in the Kaplan-Meier analysis. CONCLUSION: Omitting ICAR during thoracoabdominal aortic replacement may reduce operation and cross-clamp times and thus minimize the duration of intraoperative spinal cord hypoperfusion.

7.
J Pediatr Gastroenterol Nutr ; 78(1): 153-165, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38291686

RESUMO

The broad spectrum of hepatobiliary involvement in cystic fibrosis (CF) has been commonly referred to as cystic fibrosis liver disease (CFLD). However, differences in the definitions of CFLD have led to variations in reported prevalence, incidence rates, and standardized recommendations for diagnosis and therapies. Harmonizing the description of the spectrum of hepatobiliary involvement in all people with CF (pwCF) is deemed essential for providing a reliable account of the natural history, which in turn supports the development of meaningful clinical outcomes in patient care and research. Recognizing this necessity, The European Society for Paediatric Gastroenterology Hepatology and Nutrition (ESPGHAN) and the North American Society for Pediatric Gastroenterology, Hepatology and Nutrition (NASPGHAN) commissioned and tasked a committee to develop and propose a systematic classification of the CF hepatobiliary manifestations to increase uniformity, accuracy, and comparability for clinical, registry, and research purposes. This report describes the committee's combined expert position statement on hepatobiliary involvement in CF, which has been endorsed by NASPGHAN and ESPGHAN. We recommend using CFHBI (Cystic Fibrosis Hepato-Biliary Involvement) as the updated term to describe and classify all hepatobiliary manifestations in all pwCF. CFHBI encompasses the current extensive spectrum of phenotypical, clinical, or diagnostic expressions of liver involvement observed in pwCF. We present a schematic categorization of CFHBI, which may also be used to track and classify the changes and development of CFHBI in pwCF over time. The proposed classification for CFHBI is based on expert consensus and has not been validated for clinical practice and research purposes. Achieving validation should be an important aim for future research.


Assuntos
Fibrose Cística , Técnicas de Imagem por Elasticidade , Gastroenterologia , Hepatopatias , Criança , Humanos , Fibrose Cística/complicações , Fibrose Cística/diagnóstico , Hepatopatias/diagnóstico , Contagem de Plaquetas
8.
Artif Organs ; 48(4): 356-364, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38010063

RESUMO

BACKGROUND: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO2) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE. METHODS: Titanium oxide carriers functionalized with copper ions were employed as an antibacterial coating for heart and vascular prostheses. The coating's antibacterial efficacy was assessed using S. aureus ATCC 29213. Microscopic evaluations were conducted on both biological and artificial materials. Antibacterial activity was qualitatively assessed via a modified disc diffusion method and quantitatively measured through colony counts in NaCl suspensions. RESULTS: The coating process was successfully applied to all tested cardiovascular prosthetic materials. Qualitative assessments of antibacterial effectiveness revealed an absence of bacterial growth in the area directly beneath the coated valve. Quantitative evaluations showed a significant reduction in bacterial colonization on coated mechanical valves, with 2.95 × 104 CFU per valve, compared to 1.91 × 105 CFU in control valves. CONCLUSIONS: The 4× Cu-TiO2 coating demonstrated promising antibacterial properties against S. aureus, suggesting its potential as an effective strategy for reducing the risk of bacterial colonization of cardiovascular implants. Further studies are needed to assess the longevity of the coating and its efficacy against other pathogens.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Cobre , Staphylococcus aureus , Projetos Piloto , Materiais Revestidos Biocompatíveis , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Próteses e Implantes , Endocardite Bacteriana/prevenção & controle , Titânio
9.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37506731

RESUMO

BACKGROUND: Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations. METHODS: Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta. RESULTS: Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations. CONCLUSION: Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.


Assuntos
Ruptura Aórtica , Humanos , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Modelos Cardiovasculares , Resultado do Tratamento , Hemodinâmica , Simulação por Computador , Stents , Estresse Mecânico , Hidrodinâmica
10.
Minerva Surg ; 79(2): 219-227, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37987755

RESUMO

INTRODUCTION: Abdominal aortic aneurysm (AAA), often characterized by an abdominal aortic diameter over 3.0 cm, is managed through screening, surveillance, and surgical intervention. AAA growth can be heterogeneous and rupture carries a high mortality rate, with size and certain risk factors influencing rupture risk. Research is ongoing to accurately predict individual AAA growth rates for personalized management. Machine learning, a subset of artificial intelligence, has shown promise in various medical fields, including endoleak detection post-EVAR. However, its application for predicting AAA growth remains insufficiently explored, thus necessitating further investigation. Subsequently, this paper aims to summarize the current status of machine learning in predicting AAA growth. EVIDENCE ACQUISITION: A systematic database search of Embase, MEDLINE, Cochrane, PubMed and Google Scholar from inception till December 2022 was conducted of original articles that discussed the use of machine learning in predicting AAA growth using the aforementioned databases. EVIDENCE SYNTHESIS: Overall, 2742 articles were extracted, of which seven retrospective studies involving 410 patients were included using a predetermined criteria. Six out of seven studies applied a supervised learning approach for their machine learning (ML) models, with considerable diversity observed within specific ML models. The majority of the studies concluded that machine learning models perform better in predicting AAA growth in comparison to reference models. All studies focused on predicting AAA growth over specified durations. Maximal luminal diameter was the most frequently used indicator, with alternative predictors being AAA volume, ILT (intraluminal thrombus) and flow-medicated diameter (FMD). CONCLUSIONS: The nascent field of applying machine learning (ML) for Abdominal Aortic Aneurysm (AAA) expansion prediction exhibits potential to enhance predictive accuracy across diverse parameters. Future studies must emphasize evidencing clinical utility in a healthcare system context, thereby ensuring patient outcome improvement. This will necessitate addressing key ethical implications in establishing prospective studies related to this topic and collaboration among pivotal stakeholders within the AI field.


Assuntos
Aneurisma da Aorta Abdominal , Inteligência Artificial , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/cirurgia , Aprendizado de Máquina
11.
Artif Organs ; 48(1): 16-27, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37822301

RESUMO

BACKGROUND: The management of concomitant valvular lesions in patients undergoing left ventricular assist device (LVAD) implantation remains a topic of debate. This systematic review and meta-analysis aimed to evaluate the existing evidence on postoperative outcomes following LVAD implantation, with and without concomitant MV surgery. METHODS: A systematic database search was conducted as per PRISMA guidelines, of original articles comparing LVAD alone to LVAD plus concomitant MV surgery up to February 2023. The primary outcomes assessed were overall mortality and early mortality, while secondary outcomes included stroke, need for right ventricular assist device (RVAD) implantation, postoperative mitral valve regurgitation, major bleeding, and renal dysfunction. RESULTS: The meta-analysis included 10 studies comprising 32 184 patients. It revealed that concomitant MV surgery during LVAD implantation did not significantly affect overall mortality (OR:0.83; 95% CI: 0.53 to 1.29; p = 0.40), early mortality (OR:1.17; 95% CI: 0.63 to 2.17; p = 0.63), stroke, need for RVAD implantation, postoperative mitral valve regurgitation, major bleeding, or renal dysfunction. These findings suggest that concomitant MV surgery appears not to confer additional benefits in terms of these clinical outcomes. CONCLUSION: Based on the available evidence, concomitant MV surgery during LVAD implantation does not appear to have a significant impact on postoperative outcomes. However, decision-making regarding MV surgery should be individualized, considering patient-specific factors and characteristics. Further research with prospective studies focusing on specific patient populations and newer LVAD devices is warranted to provide more robust evidence and guide clinical practice in the management of valvular lesions in LVAD recipients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Nefropatias , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Hemorragia/complicações , Nefropatias/complicações , Estudos Retrospectivos
12.
Medicina (Kaunas) ; 59(9)2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37763737

RESUMO

Minimally invasive techniques have gained immense importance in cardiovascular surgery. While minimal access strategies for coronary and mitral valve surgery are already widely accepted and often used as standard approaches, the application of minimally invasive techniques is currently expanded towards more complex operations of the ascending aorta as well. In this new and developing field, various techniques have been established and reported ranging from upper hemisternotomy approaches, which allow even extensive operations of the ascending aorta to be performed through a minimally invasive access to sternal sparing thoracotomy strategies, which completely avoid sternal trauma during ascending aorta replacements. All of these techniques place high demands on patient selection, preoperative planning, and practical surgical implementation. Application of these strategies is currently limited to high-volume centers and highly experienced surgeons. This narrative review gives an overview of the currently available techniques with a special focus on the practical execution as well as the advantages and disadvantages of the currently available techniques. The first results demonstrate the practicability and safety of minimally invasive techniques for replacement of the ascending aorta in a well-selected patient population. With success and complication rates comparable to classic full sternotomy, the proof of concept for minimally invasive replacement of the ascending aorta is now achieved.

14.
Front Cardiovasc Med ; 10: 1229336, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37547249

RESUMO

Introduction: Surgical treatment of patients with mitral valve regurgitation and advanced heart failure remains challenging. In order to avoid peri-operative low cardiac output, Impella 5.0 or 5.5 (5.x), implanted electively in a one-stage procedure, may serve as a peri-operative short-term mechanical circulatory support system (st-MCS) in patients undergoing mitral valve surgery. Methods: Between July 2017 and April 2022, 11 consecutive patients underwent high-risk mitral valve surgery for mitral regurgitation supported with an Impella 5.x system (Abiomed, Inc. Danvers, MA). All patients were discussed in the heart team and were either not eligible for transcatheter edge-to-edge repair (TEER) or surgery was considered favorable. In all cases, the indication for Impella 5.x implantation was made during the preoperative planning phase. Results: The mean age at the time of surgery was 61.6 ± 7.7 years. All patients presented with mitral regurgitation due to either ischemic (n = 5) or dilatative (n = 6) cardiomyopathy with a mean ejection fraction of 21 ± 4% (EuroScore II 6.1 ± 2.5). Uneventful mitral valve repair (n = 8) or replacement (n = 3) was performed via median sternotomy (n = 8) or right lateral mini thoracotomy (n = 3). In six patients, concomitant procedures, either tricuspid valve repair, aortic valve replacement or CABG were necessary. The mean duration on Impella support was 8 ± 5 days. All, but one patient, were successfully weaned from st-MCS, with no Impella-related complications. 30-day survival was 90.9%. Conclusion: Protected cardiac surgery with st-MCS using the Impella 5.x is safe and feasible when applied in high-risk mitral valve surgery without st-MCS-related complications, resulting in excellent outcomes. This strategy might offer an alternative and comprehensive approach for the treatment of patients with mitral regurgitation in advanced heart failure, deemed ineligible for TEER or with need of concomitant surgery.

15.
Struct Heart ; 7(2): 100118, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37275584

RESUMO

Background: Paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) is frequent and the impact of mild PVL on outcomes remains uncertain. Our study aimed to evaluate the impact of PVL on TAVI outcomes. Methods: To analyze late outcomes of patients after TAVI according to the presence and severity of PVL, PubMed/MEDLINE, EMBASE and Google Scholar were searched for studies that reported rates of all-cause mortality/survival and/or rehospitalization and/or cardiovascular mortality accompanied by at least one Kaplan-Meier curve for any of these outcomes. We adopted a 2-stage approach to reconstruct individual patient data based on the published Kaplan-Meier graphs. Results: Thirty-eight studies with Kaplan-Meier curves met our eligibility criteria including over 25,000 patients. Patients with any degree of PVL after TAVI had a significantly higher risk of overall mortality (hazard ratio (HR), 1.52; 95% confidence interval (CI), 1.43-1.61; p < 0.001), rehospitalization (HR, 1.81; 95% CI, 1.54-2.12; p < 0.001), and cardiovascular mortality (HR, 1.52; 95% CI, 1.33-1.75; p < 0.001) over time. These findings remained consistent when we stratified the results for the methods of assessment of PVL (i.e., echocardiography vs. angiography) and PVL severity. Both moderate/severe PVL and mild PVL were associated with increased risk of overall mortality (p < 0.001), rehospitalization (p < 0.001), and cardiovascular mortality (p < 0.001) during follow-up. Conclusions: Patients with PVL, even if mild, experience higher risk of all-cause mortality, rehospitalization, and cardiovascular mortality following TAVI. These findings provide support to the implementation of procedural strategies to prevent any degree of PVL at the time of TAVI.

16.
Medicina (Kaunas) ; 59(6)2023 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-37374330

RESUMO

Background and Objectives: Sutureless aortic valve prostheses have presented favorable hemodynamic performance while facilitating minimally invasive access approaches. As the population ages, the number of patients at risk for aortic valve reoperation constantly increases. The aim of the present study is to present our single-center experience in sutureless aortic valve replacement (SU-AVR) in reoperations. Materials and Methods: The data of 18 consecutive patients who underwent SU-AVR in a reoperation between May 2020 and January 2023 were retrospectively analyzed. Results: The mean age of the patients was 67.9 ± 11.1 years; patients showed a moderate-risk profile with a median logistic EuroSCORE II of 7.8 (IQR of 3.8-32.0) %. The implantation of the Perceval S prosthesis was technically successful in all patients. The mean cardiopulmonary bypass time was 103.3 ± 50.0 min, and the cross-clamp time was 69.1 ± 38.8 min. No patients required a permanent pacemaker implantation. The postoperative gradient was 7.3 ± 2.4 mmHg, and no cases of paravalvular leakage were observed. There was one case of intraprocedural death, while the thirty-day mortality was 11%. Conclusions: Sutureless bioprosthetic valves tend to simplify the surgical procedure of a redo AVR. By maximizing the effective orifice area, sutureless valves may present an important advantage, being a safe and effective alternative not only to traditional surgical prostheses but also to transcatheter valve-in-valve approaches in select cases.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese
17.
Int J Cardiol Heart Vasc ; 47: 101233, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37388420

RESUMO

Introduction: Organ shortage, subsequent use of extended donor criteria organs and high-risk recipients needing redo-surgery are increasing the complexity of heart transplantation. Donor organ machine perfusion (MP) is an emerging technology allowing reduction of ischemia time as well as standardized evaluation of the organ. The aim of this study was to review the introduction of MP and analyze the results of heart transplantation after MP in our center. Methods: In a retrospective single-center study, data from a prospectively collected database were analysed. From July 2018 to August 2021, fourteen hearts were retrieved and perfused using the Organ Care System (OCS), 12 hearts were transplanted. Criteria to use the OCS were based on donor/recipient characteristics. Primary objective was 30-day survival, secondary objectives were major cardiac adverse events, graft function, rejection episodes as well as overall survival in the follow-up and assessment of MP technical reliability. Results: All patients survived the procedure and the postoperative 30-day interval. No MP related complications were noted. Graft ejection fraction beyond 14 days was ≥ 50% in all cases. Endomyocardial biopsy showed excellent results with no or mild rejection. Two donor hearts were rejected after OCS perfusion and evaluation. Conclusion: Ex vivo normothermic MP during organ procurement is a safe and promising technique to expand the donor pool. Reduction of cold ischemic time while providing additional donor heart assessment and reconditioning options increased the number of acceptable donor hearts. Additional clinical trials are necessary to develop guidelines regarding the application of MP.

18.
J Clin Med ; 12(12)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37373856

RESUMO

INTRODUCTION: Due to their favourable hemodynamic performance and the ability to enable minimally invasive access procedures, sutureless aortic valve prostheses have found their place in the armamentarium of cardiothoracic surgeons. In this study, we sought to review our institutional experience of sutureless aortic valve replacement (SU-AVR). METHODS: We carried out a retrospective analysis of 200 consecutive patients who underwent an SU-AVR with a Perceval valve between December 2019 and February 2023. RESULTS: The mean age of patients was 69.3 ± 8.1 years, and patients showed a moderate-risk profile with a mean logistic EuroSCORE-II of 5.2 ± 8.1%. An isolated SU-AVR was performed in 85 (42.5%) patients, concomitant CABG was performed in 75 (37.5%) and 40 patients (20%) underwent a multivalve procedure involving SU-AVR. The cardiopulmonary bypass (CPB) and cross-clamp (CC) times were 82.1 ± 35.1 and 55.5 ± 27.8 min, respectively. In-hospital, 30-day, 6-month and 1-year mortality rates were 4.5%, 6.5%, 7.5% and 8.2%, respectively. The postoperative transvalvular mean pressure gradient was 6.3 ± 1.6 mmHg and stayed stable over the follow-up time. We reported no cases of paravalvular leakage, and the incidence of stroke was 0.5%. CONCLUSIONS: With their favourable hemodynamic performance and shorter CC and CPB times, sutureless aortic valve prostheses facilitate minimally invasive access surgery, being a safe and durable promising approach for the surgical AVR.

19.
Front Cardiovasc Med ; 10: 1142953, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37139128

RESUMO

Background: Percutaneous extracorporeal life support (pECLS) is increasingly applied in cardiogenic shock (CS) despite a lack of evidence from randomized trials. The in-hospital mortality rate of pECLS still reaches up to 60%, while vascular access site complications remain a shortcoming. Surgical approaches with central cannulation for ECLS (cELCS) have emerged as a bail-out option. To date, no systematic approach exists that allows a definition of inclusion or exclusion criteria for cECLS. Methods and results: This single-center, retrospective, case-control study includes all patients fulfilling criteria for CS at the West German Heart and Vascular Center Essen/Germany between 2015 and 2020 who underwent cECLS (n = 58), excluding post-cardiotomy patients. Seventeen patients received cECLS (29.3%) as a first-line treatment strategy and 41 patients as a second-line strategy (70.7%). The main complications leading to the use of cECLS as a second-line strategy were limb ischemia (32.8%) and ongoing insufficient hemodynamic support (27.6%). The first-line cECLS cohort showed a 30-day mortality rate of 53.3% that was constant during follow-up. The 30-day mortality rate of secondary cECLS candidates was 69.8% and the rate at 3 and 6 months was 79.1%. Younger patients (<55 years) were more likely to exhibit survival benefit with cECLS (p = 0.043). Conclusion: Surgical cECLS in CS is a feasible therapy for highly selected patients with hemodynamic instability, vascular complications, or peripheral access site limitations as complementary strategy in experienced centers.

20.
Innovations (Phila) ; 18(2): 167-174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37129060

RESUMO

OBJECTIVE: Since there are concerns about the durability of mitral valve repair (MVRp) with minimally invasive techniques in patients with mitral regurgitation (MR), we aimed to evaluate the long-term outcomes of these sternal-sparing approaches when compared with conventional approaches with sternotomy in patients undergoing MVRp. METHODS: We performed a systematic review according to a preestablished protocol and performed a pooled analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies with longer follow-up comparing sternal-sparing versus sternotomy approaches for MVRp. Our outcomes of interest were survival, freedom from recurrent MR, and freedom from reoperation. RESULTS: Eleven studies met our eligibility criteria comprising 7,596 patients with follow-up (sternal sparing, n = 4,246; sternotomy, n = 3,350). Patients who underwent sternal-sparing MVRp had a significantly lower risk of mortality over time compared with patients who underwent MVRp with sternotomy (hazard ratio [HR] = 0.29, 95% confidence interval [CI]: 0.23 to 0.36, P < 0.001) in the overall analysis. However, we found no statistically significant difference between the groups in the sensitivity analysis with adjusted populations (HR = 0.85, 95% CI: 0.63 to 1.15, P = 0.301). Regarding the outcomes freedom from recurrent MR and freedom from reoperation, we found no statistically significant differences between the groups in the follow-up in both overall and sensitivity analyses. CONCLUSIONS: In comparison with MVRp with sternotomy approaches, sternal-sparing MVRp was not associated with worse outcomes in terms of survival, recurrent MR, and reoperations over time.


Assuntos
Insuficiência da Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA