Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMJ Case Rep ; 15(7)2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35868805

RESUMO

A man in his 70s with a history of multiple myeloma presented with a 4-day history of right ptosis and a rapidly enlarging upper eyelid mass. On examination, a large, firm, smooth, pink lesion was found to descend from the conjunctiva of the superior fornix. The patient underwent excision biopsy. Histopathological analysis demonstrated monoclonal plasma cells expressing light-chain kappa, consistent with extramedullary plasmacytoma. Clinical ophthalmic manifestations of multiple myeloma are rare but also diverse. Ocular surface manifestations of multiple myeloma are extremely uncommon. Variable examination findings mean those involving the conjunctiva and may be particularly challenging to diagnose. Secondary ocular extramedullary plasmacytoma, despite its rarity, should be considered in patients with multiple myeloma.


Assuntos
Blefaroptose , Mieloma Múltiplo , Plasmocitoma , Biópsia , Blefaroptose/etiologia , Túnica Conjuntiva/patologia , Humanos , Masculino , Mieloma Múltiplo/complicações , Mieloma Múltiplo/diagnóstico , Mieloma Múltiplo/patologia , Plasmocitoma/complicações , Plasmocitoma/diagnóstico , Plasmocitoma/patologia
2.
Am J Ophthalmol Case Rep ; 17: 100554, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32083221

RESUMO

PURPOSE: To report a case of a woman who had Ehlers Danlos syndrome who developed a bullous retinal detachment. OBSERVATIONS: A 33-year-old Caucasian woman presented with 1-day history of floaters and photopsia. Patient had extensive scleral ectasia. Scleral buckle could not be performed due the severity of the ectasia. Patient had a vitrectomy and subsequently had multiple re-detachments with sclera ruptures during the retinal detachment repairs. Patient required a 360-degree scleral patch graft to prevent scleral ruptures during the vitrectomy. Patient has a stable flat report 7 months post-op with vision of 1/60. CONCLUSIONS AND IMPORTANCE: This is the first case report of a patient requiring a 360-degree scleral patch graft. This option should be considered to assist in preventing scleral ruptures, intraoperatively and post operatively in patient who have an increased risk of scleral rupture, such as patients with connective tissue disorders.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA