Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Biomolecules ; 14(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38785922

RESUMO

Fundus autofluorescence (FAF) is a prompt and non-invasive imaging modality helpful in detecting pathological abnormalities within the retina and the choroid. This narrative review and case series provides an overview on the current application of FAF in posterior and panuveitis. The literature was reviewed for articles on lesion characteristics on FAF of specific posterior and panuveitis entities as well as benefits and limitations of FAF for diagnosing and monitoring disease. FAF characteristics are described for non-infectious and infectious uveitis forms as well as masquerade syndromes. Dependent on the uveitis entity, FAF is of diagnostic value in detecting disease and following the clinical course. Currently available FAF modalities which differ in excitation wavelengths can provide different pathological insights depending on disease entity and activity. Further studies on the comparison of FAF modalities and their individual value for uveitis diagnosis and monitoring are warranted.


Assuntos
Fundo de Olho , Imagem Óptica , Pan-Uveíte , Humanos , Pan-Uveíte/diagnóstico por imagem , Pan-Uveíte/diagnóstico , Imagem Óptica/métodos , Angiofluoresceinografia/métodos
2.
J Ophthalmic Inflamm Infect ; 14(1): 16, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625428

RESUMO

INTRODUCTION: The National Eye Institute Visual Function Questionnaire (NEI VFQ) is a common patient-reported outcome measure (PROM) in uveitis trials. Its psychometric properties using state-of-the-art scoring based on Rasch models, a latent trait model that improves accuracy of PROMs assessment, has not yet been investigated. METHODS: The study participants were recruited online from uveitis patient organizations, where individuals self-reported their uveitis diagnosis and visual acuity level. These participants then completed the NEI VFQ-25. The visual function (VF) and socioemotional (SE) subscales were psychometrically analysed in terms of item fit, targeting, internal consistency, dimensionality, and differential item functioning (DIF), using Rasch models. Criterion validity was examined based on associations between NEI VFQ person measures and recent visual acuity (VA) levels. RESULTS: Ninety-nine participants recruited online from uveitis patient organizations (68 women, 31 men; mean age 50 ± 15 years; 46.5% self-reported receiving systematic therapy for uveitis, 0.6% NEI VFQ-25 missing data) were included. The mean difficulty of items was lower than the average person ability. None of the items demonstrated misfit to an extent that would induce noise into the measurement. The consistency metrics person reliability and person separation index of the subscales were 0.85 and 2.34 (NEI VFQ-VF), 0.86 and 2.52 (NEI VFQ-SE), respectively. There was no evidence of multidimensionality and none of the items showed DIF by gender. The differences between item and person measures were 1.44 (NEI VFQ-VF) and 1.03 (NEI VFQ-SE). NEI VFQ-25 person measures were significantly lower in participants with visual impairment (all p values ≤ 0.007). CONCLUSION: Rasch model-based scoring of the re-engineered NEI VFQ-25 demonstrates acceptable internal consistency, item fit and construct validity for assessing two key domains of quality of life in individuals self-reporting uveitis. The PROM was targeted at a higher level of difficulty than present in our heterogeneous sample.

3.
Transl Vis Sci Technol ; 13(4): 20, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38618893

RESUMO

Purpose: The purpose of this study was to assess the current use and reliability of artificial intelligence (AI)-based algorithms for analyzing cataract surgery videos. Methods: A systematic review of the literature about intra-operative analysis of cataract surgery videos with machine learning techniques was performed. Cataract diagnosis and detection algorithms were excluded. Resulting algorithms were compared, descriptively analyzed, and metrics summarized or visually reported. The reproducibility and reliability of the methods and results were assessed using a modified version of the Medical Image Computing and Computer-Assisted (MICCAI) checklist. Results: Thirty-eight of the 550 screened studies were included, 20 addressed the challenge of instrument detection or tracking, 9 focused on phase discrimination, and 8 predicted skill and complications. Instrument detection achieves an area under the receiver operator characteristic curve (ROC AUC) between 0.976 and 0.998, instrument tracking an mAP between 0.685 and 0.929, phase recognition an ROC AUC between 0.773 and 0.990, and complications or surgical skill performs with an ROC AUC between 0.570 and 0.970. Conclusions: The studies showed a wide variation in quality and pose a challenge regarding replication due to a small number of public datasets (none for manual small incision cataract surgery) and seldom published source code. There is no standard for reported outcome metrics and validation of the models on external datasets is rare making comparisons difficult. The data suggests that tracking of instruments and phase detection work well but surgical skill and complication recognition remains a challenge for deep learning. Translational Relevance: This overview of cataract surgery analysis with AI models provides translational value for improving training of the clinician by identifying successes and challenges.


Assuntos
Inteligência Artificial , Catarata , Humanos , Reprodutibilidade dos Testes , Algoritmos , Software , Catarata/diagnóstico
4.
J Clin Med ; 13(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610657

RESUMO

Background: Systemic microvascular regression and dysfunction are considered important underlying mechanisms in heart failure with preserved ejection fraction (HFpEF), but retinal changes are unknown. Methods: This prospective study aimed to investigate whether retinal microvascular and structural parameters assessed using optical coherence tomography angiography (OCT-A) differ between patients with HFpEF and control individuals (i.e., capillary vessel density, thickness of retina layers). We also aimed to assess the associations of retinal parameters with clinical and echocardiographic parameters in HFpEF. HFpEF patients, but not controls, underwent echocardiography. Macula-centered 6 × 6 mm volume scans were computed of both eyes. Results: Twenty-two HFpEF patients and 24 controls without known HFpEF were evaluated, with an age of 74 [68-80] vs. 68 [58-77] years (p = 0.027), and 73% vs. 42% females (p = 0.034), respectively. HFpEF patients showed vascular degeneration compared to controls, depicted by lower macular vessel density (p < 0.001) and macular ganglion cell-inner plexiform layer thickness (p = 0.025), and a trend towards lower total retinal volume (p = 0.050) on OCT-A. In HFpEF, a lower total retinal volume was associated with markers of diastolic dysfunction (septal e', septal and average E/e': R2 = 0.38, 0.36, 0.25, respectively; all p < 0.05), even after adjustment for age, sex, diabetes mellitus, or atrial fibrillation. Conclusions: Patients with HFpEF showed clear levels of retinal vascular changes compared to control individuals, and retinal alterations appeared to be associated with markers of more severe diastolic dysfunction in HFpEF. OCT-A may therefore be a promising technique for monitoring systemic microvascular regression and cardiac diastolic dysfunction.

5.
Sci Rep ; 14(1): 2933, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317017

RESUMO

As most rare diseases, intermediate uveitis lacks reliable endpoints necessary for randomized clinical trials. Therefore, we investigated longitudinal changes of retinal and choriocapillaris perfusion on optical coherence tomography angiography (OCT-A) in intermediate uveitis and their prognostic value for future best corrected visual acuity (BCVA) and central retinal thickness (CRT). In this retrospective, longitudinal cohort study eyes of patients with intermediate uveitis were imaged by swept-source OCT-A (macula-centered 3 × 3 mm; PLEX Elite 9000, Zeiss) and stratified into clinically stable, worsened and improved based on changes in clinical parameters. Superficial (SRL) and deep retinal layers (DRL) were automatically analyzed for vessel density (VD) and choriocapillaris layer for non-perfused area (CCNPA) using ImageJ. Mixed-effects regression analysis controlling for age, sex, and OCT-A signal strength index (SSI) was used to evaluate the prognostic value of OCT-A parameters. 91 eyes (62 stable, 12 worsened, and 17 improved) were included in the analysis and mean follow-up time was 296 days. Longitudinal changes of VD were different between all three groups (p = 0.002 for SRL and p = 0.017 for DRL). Clinically worsened eyes showed a decrease in VD (- 0.032 ± 0.055 for SRL and - 0.027 ± 0.025 for DRL), whereas clinically improved eyes showed an increase in VD (0.037 ± 0.039 for SRL and 0.001 ± 0.023 for DRL). No difference was found for CCNPA. When controlling for age, sex, and SSI, observed differences held true in clinically worsened eyes for DRL (p = 0.011) and in clinically improved eyes for SRL (p = 0.002). An increase of CCNPA in clinically worsened eyes (p = 0.03) compared to clinically stable and improved eyes was evident. Predictive analysis revealed an association of VD in SRL and DRL at baseline with BCVA at follow-up (p = 0.039 and p = 0.047, respectively) and of VD in SRL at baseline with CRT at follow-up (p = 0.046). Alterations in retinal perfusion on OCT-A in intermediate uveitis are partly reversible and OCT-A VD may serve to predict future BCVA and CRT. Thus, perfusion parameters on OCT-A might aid monitoring and serve as prognostic imaging-biomarker.


Assuntos
Vasos Retinianos , Uveíte Intermediária , Humanos , Angiofluoresceinografia/métodos , Estudos Retrospectivos , Prognóstico , Tomografia de Coerência Óptica/métodos , Estudos Longitudinais , Progressão da Doença
6.
BMC Public Health ; 24(1): 409, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331775

RESUMO

BACKGROUND: With a rising prevalence of age-related eye diseases, prevention and early diagnosis of these conditions are key goals of public eye health. Disease-related knowledge in the general public supports these goals but there is little data available. Thus, we have assessed knowledge of cataract, glaucoma, age-related macular degeneration (AMD) and diabetic eye disease in the German adult general population in a cross-sectional study and identified target groups for health education interventions. METHODS: Knowledge assessment content was identified based on a literature review, expert input, and a list of items was generated after a qualitative selection process. The resulting 16-item instrument (4 items per condition) was administered to 1,008 participants from a survey panel, demographically representative of the adult German population. Test properties were evaluated based on a Rasch model and multiple correspondence analysis (MCA). Binary-logistic regression analysis was performed to investigate associations with age, sex, education level, employment status, marital status, income, reported health status, visual difficulties, and recent general practitioner (GP) and ophthalmologist consultations. RESULTS: Replies were correct for a median of 9 out of 16 (range 2 - 16) items, which differed between conditions (p < 0.0001). Most responses were correct for cataract items (median: 3 / 4) and least were correct for AMD items (median: 2 / 4). 27%, 9%, 1% and 19% of respondents replied correctly to all cataract, glaucoma, AMD and diabetic eye disease-related items, respectively. Rasch analysis suggested an adequate targeting of items and in MCA, no evidence of multidimensionality was present. Older age, being retired, decreased general health and recent GP or ophthalmology consultations were significantly associated with more knowledge about common eye conditions (p ≤ 0.005). GP or ophthalmology consultations remained significant in a multivariable model (p ≤ 0.011). CONCLUSIONS: Knowledge gaps regarding eye health are considerable in the German general population and should therefore be addressed in educational interventions targeting the public. Special attention when designing such campaigns needs to be paid to infrequent users of the healthcare system. Knowledge of AMD seems to be poorer compared to other eye conditions.


Assuntos
Catarata , Diabetes Mellitus , Oftalmopatias , Glaucoma , Degeneração Macular , Adulto , Humanos , Catarata/epidemiologia , Estudos Transversais , Oftalmopatias/epidemiologia , Glaucoma/epidemiologia , Glaucoma/complicações , Degeneração Macular/epidemiologia , Inquéritos e Questionários , Masculino , Feminino
7.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1933-1943, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38180569

RESUMO

PURPOSE: The main objective of this study is to assess the test-retest and inter-administration mode reliability of the Impact of Vision Impairment profile (IVI), a common patient-reported outcome measure (PROM) for people with chronic eye diseases. METHODS: The IVI was administered to adult patients with stable, chronic eye diseases two to four times per participant (average intervals between administrations 12 to 20 days; maximum two phone interviews, paper administration, electronic administration) by two trained interviewers. Rasch models were fit to the data. Intra-class correlation coefficients (ICCs), mean differences and Cronbach's alpha between test-retest administrations (two phone interviews) and inter-mode comparisons were calculated. RESULTS: Two hundred-sixteen patients (mean age 67 ± 12 years, 40% male) were included in the study. The IVI met all psychometric requirements of the Rasch model, and the division into the domains of functional items (IVI_F) and emotional items (IVI_E) corresponded to the German validation study. ICCs (all for IVI_F and IVI_E, respectively) for the retest administrations were 0.938 and 0.912, and 0.853 and 0.893 for inter-mode comparisons phone/paper, 0.939 and 0.930 for phone/electronic, and 0.937 and 0.920 for paper/electronic (all p < 0.01). Mean differences (all for IVI_F and IVI_E, respectively) for the retest administrations were 2.8% and 0.7% and ranged from 2.0% to 6.2% and from 0.4 % to 4.9% between administration modes. Cronbach's alpha ranged from 0.886 to 0.944 for retest and inter-mode comparisons. CONCLUSION: Due to the high test-retest reliability and the almost equally high comparability of different modes of administration of the IVI, the study endorses its use as a robust PROM to capture vision-related quality of life. Our results further support the use of the IVI as an endpoint in clinical trials and may simplify implementing it in both clinical trials or real-world evidence generation by offering multiple administration modes with high reliability.


Assuntos
Psicometria , Qualidade de Vida , Perfil de Impacto da Doença , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Idoso , Doença Crônica , Psicometria/métodos , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente , Oftalmopatias/diagnóstico , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Transtornos da Visão/psicologia , Acuidade Visual , Pessoa de Meia-Idade , Pessoas com Deficiência Visual/psicologia
8.
Retina ; 44(2): 214-221, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831941

RESUMO

PURPOSE: To investigate the prognostic value of quantifying optical coherence tomography (OCT)-defined hyperreflective foci (HRF) that do not correspond to hyperpigmentary abnormalities (HPAs) on color fundus photographs (CFPs)-HRF (OCT+/CFP-) -when considered in addition to HPA extent, for predicting late age-related macular degeneration development. This study sought to understand the impact of HRF (OCT+/CFP-) extent on visual sensitivity. METHODS: Two hundred eighty eyes from 140 participants with bilateral large drusen underwent imaging and microperimetry at baseline, and then 6-monthly for 3-years. The extent of HPAs on CFPs and HRF (OCT+/CFP-) on OCT was quantified at baseline. Predictive models for progression to late age-related macular degeneration, accounting for drusen volume and age, were developed using HPA extent, with and without HRF (OCT+/CFP-) extent. The association between HPA and HRF (OCT+/CFP-) extent with sector-based visual sensitivity was also evaluated. RESULTS: Incorporating HRF (OCT+/CFP-) extent did not improve the predictive performance for late age-related macular degeneration development ( P ≥ 0.32). Increasing HPA and HRF (OCT+/CFP-) extent in each sector were independently and significantly associated with reduced sector-based visual sensitivity ( P ≤ 0.004). CONCLUSION: The addition of HRF (OCT+/CFP-) extent to HPA extent did not improve the prediction of late age-related macular degeneration development. HRF (OCT+/CFP-) extent was also independently associated with local reductions in visual sensitivity, after accounting for HPAs.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Degeneração Macular/diagnóstico , Retina , Fundo de Olho , Técnicas de Diagnóstico Oftalmológico , Prognóstico , Tomografia de Coerência Óptica/métodos , Drusas Retinianas/diagnóstico
9.
BMC Geriatr ; 23(1): 583, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37735629

RESUMO

BACKGROUND: Visual impairment is an independent risk factor for falling. Whether this extends to patient-reported visual difficulties has not been assessed to date. We have evaluated whether patient-reported visual difficulties in low-contrast and low luminance situations are a risk factor for falls and concerns about falling. METHODS: Baseline assessments in outpatients with varying degrees of visual impairment aged ≥ 60 years included the Vision Impairment in Low Luminance (VILL) questionnaire and socio-demographic data; prospective follow-up assessments included falls over 12 months, the Falls Efficacy Scale (FES-I) and the VILL. The VILL was scored using Rasch models, and the FES-I was categorized following published guidelines. Associations were investigated using logistic regression analysis, controlling for age, visual acuity and known risk factors of falling. RESULTS: We included 112 participants (74 women, mean age 70 ± 7 years). Twenty-seven participants recalled any falls and eleven recalled multiple falls at follow-up. Higher VILL reading subscale and mobility subscale scores at baseline were significantly associated with reporting less multiple falls at follow-up (OR 0.559 [0.333-0.936], p = 0.027 and OR 0.595 [0.377-0.940], p = 0.026). VILL scores were significantly associated with concerns about falling (high versus low: p ≤ 0.004, reading, mobility and emotional subscales; high versus moderate: p = 0.004, emotional subscale). CONCLUSIONS: Patient-reported visual difficulties under low illumination and in low-contrast conditions are predictive of multiple falls in the future, have an additional predictive value over established risk scores, and are associated with concerns to fall. Current fall risk assessments may benefit from the inclusion of such assessments, e.g. the VILL questionnaire.


Assuntos
Acidentes por Quedas , Baixa Visão , Humanos , Feminino , Idoso , Acidentes por Quedas/prevenção & controle , Estudos Prospectivos , Acuidade Visual , Medidas de Resultados Relatados pelo Paciente
10.
Sci Rep ; 13(1): 14181, 2023 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-37648792

RESUMO

Cerebral embolization is a known complication of transcatheter aortic valve implantation (TAVI) but the effect of the procedure on the ocular perfusion is currently unclear. Thus, we investigated post-procedural morphologic and perfusion changes of the retina and choroid, using optical coherence tomography angiography (OCTA) and color fundus photography (CFP) in a prospective cohort study. Ophthalmic examinations were conducted pre- and post-TAVI. OCTA images were analyzed quantitatively based on vessel density and skeleton density of the superficial and deep retinal plexus as well as the signal intensity and flow deficits in the choriocapillaris. CFP images were assessed for presence of acute retinal ischemia, optic nerve swelling, vessel emboli, hemorrhages and cotton wool spots. Data was analyzed using linear mixed models. Twenty patients (9 women; 11 men) at a mean age of 81 ± 6 years were included. Pre- and post-interventional ocular imaging data were available for 32 eyes. The analysis revealed a significant impairment of the choriocapillaris perfusion after TAVI with an increased proportion of flow deficits (p = 0.044). When controlling for blood pressure, the average size of choriocapillaris flow voids was significantly increased (systolic and diastolic, p = 0.039 and 0.029). Qualitatively, focal areas of retinal ischemia were detected on OCTA in 33% of participants. Silent emboli or cotton wool spots were identified on CFP in 21%. Our findings indicate a reduced choroidal perfusion as well as areas of retinal ischemia and embolization in a considerable proportion of patients following TAVI. Pending confirmation in a larger sample, these complications merit monitoring as well as inclusion in consent procedures for TAVI.


Assuntos
Papiledema , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Face , Retina , Isquemia
11.
Transl Vis Sci Technol ; 12(7): 13, 2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37432848

RESUMO

Purpose: To assess inter-rater reliability in the detection of proliferative diabetic retinopathy (PDR) changes using wide-field optical coherence tomography angiography (WF-OCTA) versus fluorescein angiography (FA). Methods: This retrospective, cross-sectional study included patients with severe nonproliferative and PDR. Images were acquired with 12 × 12 mm WF-OCTA and FA with a 55° lens. Images were cropped to represent the exact same field of view. Qualitative (detection of neovascularization at the disc [NVD] and elsewhere [NVE], enlarged foveal avascular zone [FAZ], vitreous hemorrhage [VH]) and quantitative analyses (FAZ area, horizontal, vertical, and maximum FAZ diameter) were performed by 2 masked graders using ImageJ. Inter-rater reliability was calculated using unweighted Cohen's kappa coefficient (κ) for qualitative analyses and intraclass correlation coefficients (ICC) for quantitative analyses. Results: Twenty-three eyes of 17 patients were included. Inter-rater reliability was higher for FA than for WF-OCTA in qualitative analyses: κ values were 0.65 and 0.78 for detection of extended FAZ, 0.83 and 1.0 for NVD, 0.78 and 1.0 for NVE, and 0.19 and 1 for VH for WF-OCTA and FA, respectively. In contrast, inter-rater reliability was higher for WF-OCTA than for FA in the quantitative analyses: ICC values were 0.94 and 0.76 for FAZ size, 0.92 and 0.79 for horizontal FAZ diameter, 0.82 and 0.72 for vertical FAZ diameter, and 0.88 and 0.82 for maximum FAZ diameter on WF-OCTA and FA, respectively. Conclusions: Inter-rater reliability of FA is superior to WF-OCTA for qualitative analyses whereas inter-rater reliability of WF-OCTA is superior to FA for quantitative analyses. Translational Relevance: The study highlights the specific merits of both imaging modalities in terms of reliability. FA should be preferred for qualitative parameters, whereas WF-OCTA should be preferred for quantitative parameters.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Macula Lutea , Humanos , Angiofluoresceinografia , Retinopatia Diabética/diagnóstico por imagem , Tomografia de Coerência Óptica , Estudos Transversais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Neovascularização Patológica
12.
Sci Rep ; 13(1): 8162, 2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208407

RESUMO

Drusen are an important biomarker for age-related macular degeneration (AMD). Their accurate segmentation based on optical coherence tomography (OCT) is therefore relevant to the detection, staging, and treatment of disease. Since manual OCT segmentation is resource-consuming and has low reproducibility, automatic techniques are required. In this work, we introduce a novel deep learning based architecture that directly predicts the position of layers in OCT and guarantees their correct order, achieving state-of-the-art results for retinal layer segmentation. In particular, the average absolute distance between our model's prediction and the ground truth layer segmentation in an AMD dataset is 0.63, 0.85, and 0.44 pixel for Bruch's membrane (BM), retinal pigment epithelium (RPE) and ellipsoid zone (EZ), respectively. Based on layer positions, we further quantify drusen load with excellent accuracy, achieving 0.994 and 0.988 Pearson correlation between drusen volumes estimated by our method and two human readers, and increasing the Dice score to 0.71 ± 0.16 (from 0.60 ± 0.23) and 0.62 ± 0.23 (from 0.53 ± 0.25), respectively, compared to a previous state-of-the-art method. Given its reproducible, accurate, and scalable results, our method can be used for the large-scale analysis of OCT data.


Assuntos
Calcinose , Degeneração Macular , Drusas Retinianas , Humanos , Drusas Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Retina/diagnóstico por imagem , Degeneração Macular/diagnóstico por imagem
13.
Bioengineering (Basel) ; 10(4)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37106625

RESUMO

Optical coherence tomography (OCT) enables in vivo diagnostics of individual retinal layers in the living human eye. However, improved imaging resolution could aid diagnosis and monitoring of retinal diseases and identify potential new imaging biomarkers. The investigational high-resolution OCT platform (High-Res OCT; 853 nm central wavelength, 3 µm axial-resolution) has an improved axial resolution by shifting the central wavelength and increasing the light source bandwidth compared to a conventional OCT device (880 nm central wavelength, 7 µm axial-resolution). To assess the possible benefit of a higher resolution, we compared the retest reliability of retinal layer annotation from conventional and High-Res OCT, evaluated the use of High-Res OCT in patients with age-related macular degeneration (AMD), and assessed differences of both devices on subjective image quality. Thirty eyes of 30 patients with early/intermediate AMD (iAMD; mean age 75 ± 8 years) and 30 eyes of 30 age-similar subjects without macular changes (62 ± 17 years) underwent identical OCT imaging on both devices. Inter- and intra-reader reliability were analyzed for manual retinal layer annotation using EyeLab. Central OCT B-scans were graded for image quality by two graders and a mean-opinion-score (MOS) was formed and evaluated. Inter- and intra-reader reliability were higher for High-Res OCT (greatest benefit for inter-reader reliability: ganglion cell layer; for intra-reader reliability: retinal nerve fiber layer). High-Res OCT was significantly associated with an improved MOS (MOS 9/8, Z-value = 5.4, p < 0.01) mainly due to improved subjective resolution (9/7, Z-Value 6.2, p < 0.01). The retinal pigment epithelium drusen complex showed a trend towards improved retest reliability in High-Res OCT in iAMD eyes but without statistical significance. Improved axial resolution of the High-Res OCT benefits retest reliability of retinal layer annotation and improves perceived image quality and resolution. Automated image analysis algorithms could also benefit from the increased image resolution.

15.
J Cogn Neurosci ; 35(6): 976-989, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36976900

RESUMO

Animals need to cope with abundant sensory information, and one strategy is to selectively direct attention to only the most relevant part of the environment. Although the cortical networks of selective attention have been studied extensively, its underlying neurotransmitter systems, especially the role of the inhibitory neurotransmitter gamma-aminobutyric acid (GABA), remain less well understood. Increased GABAA receptor activity because of administration of benzodiazepines such as lorazepam is known to slow reactions in cognitive tasks. However, there is limited knowledge about GABAergic involvement in selective attention. Particularly, it is unknown whether increased GABAA receptor activity slows the build-up of selectivity or generally widens attentional focus. To address this question, participants (n = 29) received 1 mg lorazepam and placebo (within-subjects, double-blind) and performed an extended version of the flanker task. The spatial distribution of selective attention was studied by systematically manipulating number and position of incongruent flankers; the temporal build-up was characterized using delta plots. An online task version was presented to an independent, unmedicated sample (n = 25) to verify task effects. Under placebo and in the unmedicated sample, only the number of incongruent flankers, but not their position, influenced RTs. Incongruent flankers impaired RTs more strongly under lorazepam than placebo, especially when adjacent to the target. Delta plot analyses of RT showed that this effect persisted even when participants reacted slowly, indicating that lorazepam-induced impairments in selective attention do not result from simply slowed down build-up of selectivity. Instead, our data indicate that increased GABAA receptor activity widens the attentional focus.


Assuntos
Atenção , Moduladores GABAérgicos , Receptores de GABA-A , Método Duplo-Cego , Lorazepam/farmacologia , Receptores de GABA-A/efeitos dos fármacos , Receptores de GABA-A/metabolismo , Humanos , Atenção/efeitos dos fármacos , Atenção/fisiologia , Moduladores GABAérgicos/farmacologia
16.
Sci Rep ; 12(1): 21911, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-36535990

RESUMO

Drusen are hallmarks of early and intermediate age-related macular degeneration (AMD) but their quantification remains a challenge. We compared automated drusen volume measurements between different OCT devices. We included 380 eyes from 200 individuals with bilateral intermediate (iAMD, n = 126), early (eAMD, n = 25) or no AMD (n = 49) from the MACUSTAR study. We assessed OCT scans from Cirrus (200 × 200 macular cube, 6 × 6 mm; Zeiss Meditec, CA) and Spectralis (20° × 20°, 25 B-scans; 30° × 25°, 241 B-scans; Heidelberg Engineering, Germany) devices. Sensitivity and specificity for drusen detection and differences between modalities were assessed with intra-class correlation coefficients (ICCs) and mean difference in a 5 mm diameter fovea-centered circle. Specificity was > 90% in the three modalities. In eAMD, we observed highest sensitivity in the denser Spectralis scan (68.1). The two different Spectralis modalities showed a significantly higher agreement in quantifying drusen volume in iAMD (ICC 0.993 [0.991-0.994]) than the dense Spectralis with Cirrus scan (ICC 0.807 [0.757-0.847]). Formulae for drusen volume conversion in iAMD between the two devices are provided. Automated drusen volume measures are not interchangeable between devices and softwares and need to be interpreted with the used imaging devices and software in mind. Accounting for systematic difference between methods increases comparability and conversion formulae are provided. Less dense scans did not affect drusen volume measurements in iAMD but decreased sensitivity for medium drusen in eAMD.Trial registration: ClinicalTrials.gov NCT03349801. Registered on 22 November 2017.


Assuntos
Degeneração Macular , Humanos , Degeneração Macular/diagnóstico , Retina , Tomografia de Coerência Óptica/métodos , Software , Fóvea Central
17.
BMC Med Educ ; 22(1): 803, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36397110

RESUMO

BACKGROUND: The use of artificial intelligence applications in medicine is becoming increasingly common. At the same time, however, there are few initiatives to teach this important and timely topic to medical students. One reason for this is the predetermined medical curriculum, which leaves very little room for new topics that were not included before. We present a flipped classroom course designed to give undergraduate medical students an elaborated first impression of AI and to increase their "AI readiness". METHODS: The course was tested and evaluated at Bonn Medical School in Germany with medical students in semester three or higher and consisted of a mixture of online self-study units and online classroom lessons. While the online content provided the theoretical underpinnings and demonstrated different perspectives on AI in medical imaging, the classroom sessions offered deeper insight into how "human" diagnostic decision-making differs from AI diagnoses. This was achieved through interactive exercises in which students first diagnosed medical image data themselves and then compared their results with the AI diagnoses. We adapted the "Medical Artificial Intelligence Scale for Medical Students" to evaluate differences in "AI readiness" before and after taking part in the course. These differences were measured by calculating the so called "comparative self-assessment gain" (CSA gain) which enables a valid and reliable representation of changes in behaviour, attitudes, or knowledge. RESULTS: We found a statistically significant increase in perceived AI readiness. While values of CSA gain were different across items and factors, the overall CSA gain regarding AI readiness was satisfactory. CONCLUSION: Attending a course developed to increase knowledge about AI in medical imaging can increase self-perceived AI readiness in medical students.


Assuntos
Estudantes de Medicina , Humanos , Alfabetização , Inteligência Artificial , Currículo , Faculdades de Medicina
18.
Sci Rep ; 12(1): 14337, 2022 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-36038591

RESUMO

Clinical discrimination of posterior uveitis entities remains a challenge. This exploratory, cross-sectional study investigated the green (GEFC) and red emission fluorescent components (REFC) of retinal and choroidal lesions in posterior uveitis to facilitate discrimination of the different entities. Eyes were imaged by color fundus photography, spectrally resolved fundus autofluorescence (Color-FAF) and optical coherence tomography. Retinal/choroidal lesions' intensities of GEFC (500-560 nm) and REFC (560-700 nm) were determined, and intensity-normalized Color-FAF images were compared for birdshot chorioretinopathy, ocular sarcoidosis, acute posterior multifocal placoid pigment epitheliopathy (APMPPE), and punctate inner choroidopathy (PIC). Multivariable regression analyses were performed to reveal possible confounders. 76 eyes of 45 patients were included with a total of 845 lesions. Mean GEFC/REFC ratios were 0.82 ± 0.10, 0.92 ± 0.11, 0.86 ± 0.10, and 1.09 ± 0.19 for birdshot chorioretinopathy, sarcoidosis, APMPPE, and PIC lesions, respectively, and were significantly different in repeated measures ANOVA (p < 0.0001). Non-pigmented retinal/choroidal lesions, macular neovascularizations, and fundus areas of choroidal thinning featured predominantly GEFC, and pigmented retinal lesions predominantly REFC. Color-FAF imaging revealed involvement of both, short- and long-wavelength emission fluorophores in posterior uveitis. The GEFC/REFC ratio of retinal and choroidal lesions was significantly different between distinct subgroups. Hence, this novel imaging biomarker could aid diagnosis and differentiation of posterior uveitis entities.


Assuntos
Sarcoidose , Uveíte Posterior , Coriorretinopatia de Birdshot , Corantes , Estudos Transversais , Angiofluoresceinografia/métodos , Humanos , Imagem Óptica/métodos , Tomografia de Coerência Óptica/métodos , Uveíte Posterior/diagnóstico por imagem
19.
Sci Rep ; 12(1): 9315, 2022 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-35662264

RESUMO

Cerebral small vessel disease (CSVD) is an important contributor to cognitive impairment and stroke. Previous research has suggested associations with alterations in single retinal layers. We have assessed changes of all individual retinal layers in CSVD using high-resolution optical coherence tomography (OCT) for the first time. Subjects with recent magnetic resonance imaging (MRI) underwent macular and peripapillary retinal imaging using OCT for this case-control study. Number and volume ratio index (WMRI) of white matter lesions (WML) were determined on MRI. Data were analyzed using multiple linear regression models. 27 CSVD patients and 9 control participants were included. Ganglion cell layer (GCL) volume was significantly reduced in patients with CSVD compared to age-matched controls (p = 0.008). In patients with CSVD, larger foveal outer plexiform layer (OPL) volume and decreased temporal peripapillary retinal nerve fiber layer (RNFL) thickness were significantly associated with a higher WMRI in linear regression when controlling for age (p ≤ 0.033). Decreased foveal GCL volume and temporal-inferior RNFL thickness at Bruch's membrane opening (MRW), and increased temporal MRW were associated with a higher WML burden (p ≤ 0.037). Thus, we identified alterations in several OCT layers in individuals with CSVD (GCL, OPL, MRW and RNFL). Their potential diagnostic value merits further study.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Fibras Nervosas , Estudos de Casos e Controles , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Doenças de Pequenos Vasos Cerebrais/patologia , Humanos , Fibras Nervosas/patologia , Retina/diagnóstico por imagem , Retina/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos
20.
Transl Vis Sci Technol ; 11(4): 21, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35446409

RESUMO

Purpose: To quantify the impact of the mode of administration (MOA) on scores of the Vision Impairment in Low Luminance (VILL) questionnaire. Methods: The VILL questionnaire was implemented using different MOAs (paper, interview, electronic), in addition to a demographical survey of adult participants recruited at an outpatient eye clinic, with the initial MOA being either paper or interview. Polytomous Rasch models were used to generate person measure scores for the three subscales of the VILL questionnaire (reading, VILL_R; mobility, VILL_M; and emotional, VILL_E). Measures of agreement among the different MOAs were calculated (self-administered paper/interview, self-administered paper/self-administered electronic, and interview/self-administered electronic). An age-matched analysis was performed to control for the impact of the initial MOA, administration interval, visual acuity, and self-reported hearing difficulties. Results: We included 309 participants (mean age, 63 ± 14 years; 61% female). Intra-class correlation coefficients were 0.930, 0.919, and 0.799 for paper versus interview assessment; 0.951, 0.959, and 0.916 for paper versus electronic; and 0.967, 0.955, and 0.907 for interview versus electronic assessment (VILL_R, VILL_M, and VILL_E, respectively). Mean differences were 0.35, 0.41, and 1.74 logits; 0.32, 0.18, and 0.68 logits; and 0.08, 0.22, and 0.63 logits, respectively. None of the mentioned factors significantly affected the results (corrected P ≥ 0.11). Conclusions: Paper, interview, and electronic MOAs of the VILL can be considered equivalent. Reporting across the main MOAs of self-administration (paper) and interviewer-administration was unaffected by better eye visual acuity and self-reported hearing difficulties. Translational Relevance: The results support use of the VILL questionnaire with flexible modes of administration.


Assuntos
Qualidade de Vida , Visão Ocular , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida/psicologia , Autorrelato , Inquéritos e Questionários , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA