Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Br J Radiol ; 96(1145): 20201465, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36802769

RESUMO

OBJECTIVE: Investigate the performance of qualitative review (QR) for assessing dynamic susceptibility contrast (DSC-) MRI data quality in paediatric normal brain and develop an automated alternative to QR. METHODS: 1027 signal-time courses were assessed by Reviewer 1 using QR. 243 were additionally assessed by Reviewer 2 and % disagreements and Cohen's κ (κ) were calculated. The signal drop-to-noise ratio (SDNR), root mean square error (RMSE), full width half maximum (FWHM) and percentage signal recovery (PSR) were calculated for the 1027 signal-time courses. Data quality thresholds for each measure were determined using QR results. The measures and QR results trained machine learning classifiers. Sensitivity, specificity, precision, classification error and area under the curve from a receiver operating characteristic curve were calculated for each threshold and classifier. RESULTS: Comparing reviewers gave 7% disagreements and κ = 0.83. Data quality thresholds of: 7.6 for SDNR; 0.019 for RMSE; 3 s and 19 s for FWHM; and 42.9 and 130.4% for PSR were produced. SDNR gave the best sensitivity, specificity, precision, classification error and area under the curve values of 0.86, 0.86, 0.93, 14.2% and 0.83. Random forest was the best machine learning classifier, giving sensitivity, specificity, precision, classification error and area under the curve of 0.94, 0.83, 0.93, 9.3% and 0.89. CONCLUSION: The reviewers showed good agreement. Machine learning classifiers trained on signal-time course measures and QR can assess quality. Combining multiple measures reduces misclassification. ADVANCES IN KNOWLEDGE: A new automated quality control method was developed, which trained machine learning classifiers using QR results.


Assuntos
Aprendizado de Máquina , Imageamento por Ressonância Magnética , Humanos , Criança , Sensibilidade e Especificidade , Curva ROC
2.
Pediatr Radiol ; 52(6): 1134-1149, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35290489

RESUMO

BACKGROUND: Relative cerebral blood volume (rCBV) measured using dynamic susceptibility-contrast MRI can differentiate between low- and high-grade pediatric brain tumors. Multicenter studies are required for translation into clinical practice. OBJECTIVE: We compared leakage-corrected dynamic susceptibility-contrast MRI perfusion parameters acquired at multiple centers in low- and high-grade pediatric brain tumors. MATERIALS AND METHODS: Eighty-five pediatric patients underwent pre-treatment dynamic susceptibility-contrast MRI scans at four centers. MRI protocols were variable. We analyzed data using the Boxerman leakage-correction method producing pixel-by-pixel estimates of leakage-uncorrected (rCBVuncorr) and corrected (rCBVcorr) relative cerebral blood volume, and the leakage parameter, K2. Histological diagnoses were obtained. Tumors were classified by high-grade tumor. We compared whole-tumor median perfusion parameters between low- and high-grade tumors and across tumor types. RESULTS: Forty tumors were classified as low grade, 45 as high grade. Mean whole-tumor median rCBVuncorr was higher in high-grade tumors than low-grade tumors (mean ± standard deviation [SD] = 2.37±2.61 vs. -0.14±5.55; P<0.01). Average median rCBV increased following leakage correction (2.54±1.63 vs. 1.68±1.36; P=0.010), remaining higher in high-grade tumors than low grade-tumors. Low-grade tumors, particularly pilocytic astrocytomas, showed T1-dominant leakage effects; high-grade tumors showed T2*-dominance (mean K2=0.017±0.049 vs. 0.002±0.017). Parameters varied with tumor type but not center. Median rCBVuncorr was higher (mean = 1.49 vs. 0.49; P=0.015) and K2 lower (mean = 0.005 vs. 0.016; P=0.013) in children who received a pre-bolus of contrast agent compared to those who did not. Leakage correction removed the difference. CONCLUSION: Dynamic susceptibility-contrast MRI acquired at multiple centers helped distinguish between children's brain tumors. Relative cerebral blood volume was significantly higher in high-grade compared to low-grade tumors and differed among common tumor types. Vessel leakage correction is required to provide accurate rCBV, particularly in low-grade enhancing tumors.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Volume Sanguíneo Cerebral , Criança , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos
3.
PLoS One ; 13(3): e0194841, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29590180

RESUMO

OBJECTIVES: Previously, we showed that pre-treatment tumour plasma perfusion (Fp) predicts RECIST response to induction chemotherapy (ICT) in locoregionally advanced head and neck squamous cell carcinoma (HNSCC). The aim here was to determine whether the pre-treatment tumour Fp estimate, changes in tumour Fp or RECIST response post 2 cycles of ICT were prognostic for long-term survival outcomes. METHODS: A prospective study enrolled patients with high stage HNSCC treated with docetaxel (T), cisplatin (P) and 5-fluorouracil (F) (ICT) followed by synchronous cisplatin and intensity modulated radiotherapy. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) before and after two cycles of ICT was used to measure Fp and RECIST response. RESULTS: Forty-two patients were recruited and 37 underwent two scans. The median follow-up was 36 (range 23-49) months. Pre-treatment tumour Fp (stratified by median) was not prognostic for overall survival (p = 0.42), disease specific survival (p = 0.20) and locoregional control (p = 0.64). Neither change in tumour Fp nor RECIST response post two cycles of ICT was prognostic for any outcome (p>0.21). CONCLUSION: DCE-MRI parameters do not predict long-term survival outcomes following ICT and RECIST response to ICT may not be an appropriate endpoint to determine early efficacy of a treatment in HNSCC patients.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma de Células Escamosas/mortalidade , Neoplasias de Cabeça e Pescoço/mortalidade , Quimioterapia de Indução/mortalidade , Adulto , Idoso , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Cisplatino/administração & dosagem , Docetaxel , Feminino , Fluoruracila/administração & dosagem , Seguimentos , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Critérios de Avaliação de Resposta em Tumores Sólidos , Taxa de Sobrevida , Taxoides/administração & dosagem
4.
Br J Cancer ; 116(11): 1436-1443, 2017 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-28449009

RESUMO

BACKGROUND: The microvascular contrast agent transfer constant Ktrans has shown prognostic value in cervical cancer patients treated with chemoradiotherapy. This study aims to determine whether this is explained by the contribution to Ktrans of plasma flow (Fp), vessel permeability surface-area product (PS), or a combination of both. METHODS: Pre-treatment dynamic contrast-enhanced MRI (DCE-MRI) data from 36 patients were analysed using the two-compartment exchange model. Estimates of Fp, PS, Ktrans, and fractional plasma and interstitial volumes (vp and ve) were made and used in univariate and multivariate survival analyses adjusting for clinicopathologic variables tumour stage, nodal status, histological subtype, patient age, tumour volume, and treatment type (chemoradiotherapy vs radiotherapy alone). RESULTS: In univariate analyses, Fp (HR=0.25, P=0.0095) and Ktrans (HR=0.20, P=0.032) were significantly associated with disease-free survival while PS, vp and ve were not. In multivariate analyses adjusting for clinicopathologic variables, Fp and Ktrans significantly increased the accuracy of survival predictions (P=0.0089). CONCLUSIONS: The prognostic value of Ktrans in cervical cancer patients treated with chemoradiotherapy is explained by microvascular plasma flow (Fp) rather than vessel permeability surface-area product (PS).


Assuntos
Permeabilidade Capilar , Carcinoma/diagnóstico por imagem , Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Imageamento por Ressonância Magnética , Neoplasias do Colo do Útero/diagnóstico por imagem , Antineoplásicos/uso terapêutico , Braquiterapia , Carcinoma/secundário , Carcinoma/terapia , Quimiorradioterapia , Cisplatino/uso terapêutico , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Metástase Linfática , Pessoa de Meia-Idade , Plasma/fisiologia , Estudos Prospectivos , Curva ROC , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/terapia
5.
J Magn Reson Imaging ; 45(5): 1325-1334, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27545824

RESUMO

PURPOSE: To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. MATERIALS AND METHODS: Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. RESULTS: The estimated IVIM parameters from model simulations were found significantly different (P < 0.05) using simultaneous and constrained fitting methods at low SNR. Higher accuracy and reproducibility were achieved with the constrained fitting method. Using this method, the mean error (%) for the estimated IVIM parameters at a clinically relevant SNR = 40 were D 0.35, D* 41.0 and f 4.55 for the tumor model and D 1.87, D* 2.48, and f 7.49 for the gray matter model. The most robust parameters were the IVIM-D and IVIM-f. The IVIM-D* was increasingly overestimated at low perfusion. CONCLUSION: A constrained IVIM fitting method provides more accurate and reproducible IVIM parameters in low-perfused tissue compared with simultaneous fitting. LEVEL OF EVIDENCE: 3 J. MAGN. RESON. IMAGING 2017;45:1325-1334.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Criança , Simulação por Computador , Meios de Contraste , Difusão , Humanos , Movimento (Física) , Distribuição Normal , Perfusão , Reprodutibilidade dos Testes , Razão Sinal-Ruído
6.
J Magn Reson Imaging ; 43(4): 981-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26514288

RESUMO

PURPOSE: To investigate how arterial input functions (AIFs) vary with age in children and compare the use of individual and population AIFs for calculating gray matter CBV values. Quantitative measures of cerebral blood volume (CBV) using dynamic susceptibility contrast (DSC) magnetic resonance imaging (MRI) require measurement of an AIF. AIFs are affected by numerous factors including patient age. Few data presenting AIFs in the pediatric population exists. MATERIALS AND METHODS: Twenty-two previously treated pediatric brain tumor patients (mean age, 6.3 years; range, 2.0-15.3 years) underwent DSC-MRI scans on a 3T MRI scanner over 36 visits. AIFs were measured in the middle cerebral artery. A functional form of an adult population AIF was fitted to each AIF to obtain parameters reflecting AIF shape. The relationship between parameters and age was assessed. Correlations between gray matter CBV values calculated using the resulting population and individual patient AIFs were explored. RESULTS: There was a large variation in individual patient AIFs but correlations between AIF shape and age were observed. The center (r = 0.596, P < 0.001) and width of the first-pass peak (r = 0.441, P = 0.007) were found to correlate significantly with age. Intrapatient coefficients of variation were significantly lower than interpatient values for all parameters (P < 0.001). Differences in CBV values calculated with an overall population and age-specific population AIF compared to those calculated with individual AIFs were 31.3% and 31.0%, respectively. CONCLUSION: Parameters describing AIF shape correlate with patient age in line with expected changes in cardiac output. In pediatric DSC-MRI studies individual patient AIFs are recommended.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Substância Cinzenta/patologia , Imageamento por Ressonância Magnética , Adolescente , Determinação do Volume Sanguíneo , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Criança , Pré-Escolar , Substância Cinzenta/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Lactente , Reprodutibilidade dos Testes
7.
Oral Oncol ; 51(5): 508-13, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25700703

RESUMO

OBJECTIVES: Non-response to induction chemotherapy (IC) occurs in 30% of head and neck squamous cell carcinoma (HNSCC) and has been predicted by tumor plasma flow (Fp) derived by perfusion computed tomography. The present study was designed to test whether baseline tumor Fp determined by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) would predict IC response. MATERIALS AND METHODS: A prospective open study powered to test the relationship between tumor Fp and response to IC (docetaxel, cisplatin, 5-fluorouracil) enrolled 50 patients with stage IV HNSCC. Response after two IC cycles was measured by MRI using Response Evaluation Criteria in Solid Tumors in 37 patients. Tumor Fp (primary end point) and multiple parameters in tumors and lymph nodes (secondary end points) were generated at baseline. Differences in baseline DCE-MRI parameters according to IC response were assessed by the Mann-Whitney U test, and predictive value by receiver operating characteristic (ROC) analysis. RESULTS: Median baseline tumor Fp was 53.2ml/100ml/min in 25 responders and 23.9 in 12 non-responders (U 82; P=0.027; area under ROC curve (AUC) 0.73). Median baseline Fp in lymph nodes was 25.8ml/100ml/min for 37 nodes in 25 responders and 17.1 for 15 nodes in 12 non-responders (U 186, P=0.066; AUC 0.67). Frequency of IC response in 37 patients was 68% overall, 83% for tumor Fp above the median (40.6ml/100ml/min) and 45% below the median. Other DCE-MRI parameters were not associated with IC response. CONCLUSION: Pre-treatment tumor Fp determined by DCE-MRI predicts IC response in HNSCC.


Assuntos
Carcinoma de Células Escamosas/irrigação sanguínea , Meios de Contraste , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Adulto , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Feminino , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA