Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39254690

RESUMO

In 2015 the United Nations issued 17 Sustainable Development Goals (SDGs) addressing a wide range of global social, economic, and environmental challenges. The main goal of this paper is to provide an understanding of how the current System of Radiological Protection relates to these SDGs. In the first part it is proposed that the current System of Radiological Protection is implicitly linked to sustainable development. This is substantiated by analysing the features of the current System as set out by the International Commission on Radiological Protection (ICRP) in its publications. In the second part it is proposed that sustainability should be considered and more explicitly addressed in the next ICRP general recommendations, as part of the currently ongoing review and revision of the current System. A few examples are given of how this could be realised, and it is proposed that this issue should be discussed and developed together with the international community interested in radiological protection.

2.
Radiat Res ; 199(6): 616-627, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37084254

RESUMO

Inter-laboratory exercises are important tools within the European network for biological dosimetry and physical retrospective dosimetry (RENEB) to validate and improve the performance of member laboratories and to ensure an operational network with high quality standards for dose estimations in case of a large-scale radiological or nuclear event. In addition to the RENEB inter-laboratory comparison 2021, several inter-laboratory comparisons have been performed in the frame of RENEB for a number of assays in recent years. This publication gives an overview of RENEB inter-laboratory comparisons for biological dosimetry assays in the past and a final summary of the challenges and lessons learnt from the RENEB inter-laboratory comparison 2021. In addition, the dose estimates of all RENEB inter-laboratory comparisons since 2013 that have been conducted for the dicentric chromosome assay, the most established and applied assay, are compared and discussed.


Assuntos
Exposição à Radiação , Monitoramento de Radiação , Exposição à Radiação/análise , Estudos Retrospectivos , Bioensaio , Laboratórios
3.
Radiat Res ; 199(6): 583-590, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057978

RESUMO

Translocation analysis using fluorescence in situ hybridization (FISH) is the method of choice for dose assessment in case of chronic or past exposures to ionizing radiation. Although it is a widespread technique, unlike dicentrics, the number of FISH-based inter-laboratory comparisons is small. For this reason, although the current Running the European Network of Biological and Physical retrospective Dosimetry (RENEB) inter-laboratory comparison 2021 was designed as a fast response to a real emergency scenario, it was considered a good opportunity to perform an inter-laboratory comparison using the FISH technique to gain further experience. The Bundeswehr Institute of Radiobiology provided peripheral blood samples from one healthy human volunteer. Three test samples were irradiated with blinded doses of 0, 1.2, and 3.5 Gy, respectively. Samples were then sent to the seven participating laboratories. The FISH technique was applied according to the standard procedure of each laboratory. Both, the frequency of translocations and the estimated dose for each sample were sent to the coordinator using a special scoring sheet for FISH. All participants sent their results in due time. However, although it was initially requested to send the results based on the full analysis, evaluating 500 equivalent cells, most laboratories only sent the results based on triage, with a smaller number of analyzed cells. In the triage analysis, there was great heterogeneity in the number of equivalent cells scored. On the contrary, for the full analysis, this number was more homogeneous. For all three samples, one laboratory showed outlier yields compared to the other laboratories. Excluding these results, in the triage analysis, the frequency of translocations in sample no. 1 ranged from 0 to 0.013 translocations per cell, and for samples no. 2 and no. 3 the genomic mean frequency were 0.27 ± 0.03 and 1.47 ± 0.14, with a coefficient of variation of 0.29 and 0.23 respectively. Considering only results obtained in the triage analysis for sample no. 1, all laboratories, except one, classified this sample as the non-irradiated one. For sample no. 2, excluding the outlier value, the mean reported dose was 1.74 ± 0.16 Gy indicating a mean deviation of about 0.5 Gy to the delivered dose of 1.2 Gy. For sample no. 3 the mean dose estimated was 4.21 ± 0.21 Gy indicating a mean deviation of about 0.7 Gy to the delivered dose of 3.5 Gy. In the frame of RENEB, this is the second FISH-based inter-laboratory comparison. The whole exercise was planned as a response to an emergency, therefore, a triage analysis was requested for all the biomarkers except for FISH. Although a full analysis was initially requested for FISH, most of the laboratories reported only a triage-based result. The main reason is that it was not clearly stated what was required before starting the exercise. Results show that most of the laboratories successfully discriminated unexposed and irradiated samples from each other without any overlap. A good agreement in the observed frequencies of translocations was observed but there was a tendency to overestimate the delivered doses. Efforts to improve the harmonization of this technique and subsequent exercises to elucidate the reason for this trend should be promoted.


Assuntos
Radiometria , Translocação Genética , Humanos , Hibridização in Situ Fluorescente/métodos , Estudos Retrospectivos , Radiometria/métodos , Bioensaio/métodos , Aberrações Cromossômicas
4.
Radiat Res ; 199(6): 598-615, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37057982

RESUMO

Early and high-throughput individual dose estimates are essential following large-scale radiation exposure events. In the context of the Running the European Network for Biodosimetry and Physical Dosimetry (RENEB) 2021 exercise, gene expression assays were conducted and their corresponding performance for dose-assessment is presented in this publication. Three blinded, coded whole blood samples from healthy donors were exposed to 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 1 Gy/min) using the X-ray source Yxlon. These exposures correspond to clinically relevant groups of unexposed, low dose (no severe acute health effects expected) and high dose exposed individuals (requiring early intensive medical health care). Samples were sent to eight teams for dose estimation and identification of clinically relevant groups. For quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray analyses, samples were lysed, stored at 20°C and shipped on wet ice. RNA isolations and assays were run in each laboratory according to locally established protocols. The time-to-result for both rough early and more precise later reports has been documented where possible. Accuracy of dose estimates was calculated as the difference between estimated and reference doses for all doses (summed absolute difference, SAD) and by determining the number of correctly reported dose estimates that were defined as ±0.5 Gy for reference doses <2.5 Gy and ±1.0 Gy for reference doses >3 Gy, as recommended for triage dosimetry. We also examined the allocation of dose estimates to clinically/diagnostically relevant exposure groups. Altogether, 105 dose estimates were reported by the eight teams, and the earliest report times on dose categories and estimates were 5 h and 9 h, respectively. The coefficient of variation for 85% of all 436 qRT-PCR measurements did not exceed 10%. One team reported dose estimates that systematically deviated several-fold from reported dose estimates, and these outliers were excluded from further analysis. Teams employing a combination of several genes generated about two-times lower median SADs (0.8 Gy) compared to dose estimates based on single genes only (1.7 Gy). When considering the uncertainty intervals for triage dosimetry, dose estimates of all teams together were correctly reported in 100% of the 0 Gy, 50% of the 1.2 Gy and 50% of the 3.5 Gy exposed samples. The order of dose estimates (from lowest to highest) corresponding to three dose categories (unexposed, low dose and highest exposure) were correctly reported by all teams and all chosen genes or gene combinations. Furthermore, if teams reported no exposure or an exposure >3.5 Gy, it was always correctly allocated to the unexposed and the highly exposed group, while low exposed (1.2 Gy) samples sometimes could not be discriminated from highly (3.5 Gy) exposed samples. All teams used FDXR and 78.1% of correct dose estimates used FDXR as one of the predictors. Still, the accuracy of reported dose estimates based on FDXR differed considerably among teams with one team's SAD (0.5 Gy) being comparable to the dose accuracy employing a combination of genes. Using the workflow of this reference team, we performed additional experiments after the exercise on residual RNA and cDNA sent by six teams to the reference team. All samples were processed similarly with the intention to improve the accuracy of dose estimates when employing the same workflow. Re-evaluated dose estimates improved for half of the samples and worsened for the others. In conclusion, this inter-laboratory comparison exercise enabled (1) identification of technical problems and corrections in preparations for future events, (2) confirmed the early and high-throughput capabilities of gene expression, (3) emphasized different biodosimetry approaches using either only FDXR or a gene combination, (4) indicated some improvements in dose estimation with FDXR when employing a similar methodology, which requires further research for the final conclusion and (5) underlined the applicability of gene expression for identification of unexposed and highly exposed samples, supporting medical management in radiological or nuclear scenarios.


Assuntos
Exposição à Radiação , Radiometria , Humanos , Relação Dose-Resposta à Radiação , Radiometria/métodos , Exposição à Radiação/efeitos adversos , Exposição à Radiação/análise , Bioensaio/métodos , Expressão Gênica
5.
Radiat Environ Biophys ; 62(2): 175-180, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37097458

RESUMO

Ionising radiation has been used for over a century for peaceful purposes, revolutionising health care and promoting well-being through its application in industry, science, and medicine. For almost as long, the International Commission on Radiological Protection (ICRP) has promoted understanding of health and environmental risks of ionising radiation and developed a protection system that enables the safe use of ionising radiation in justified and beneficial practices, providing protection from all sources of radiation. However, we are concerned that a shortage of investment in training, education, research, and infrastructure seen in many sectors and countries may compromise society's ability to properly manage radiation risks, leading to unjustified exposure to or unwarranted fear of radiation, impacting the physical, mental, and social well-being of our peoples. This could unduly limit the potential for research and development in new radiation technologies (healthcare, energy, and the environment) for beneficial purposes. ICRP therefore calls for action to strengthen expertise in radiological protection worldwide through: (1) National governments and funding agencies strengthening resources for radiological protection research allocated by governments and international organisations, (2) National research laboratories and other institutions launching and sustaining long-term research programmes, (3) Universities developing undergraduate and graduate university programmes and making students aware of job opportunities in radiation-related fields, (4) Using plain language when interacting with the public and decision makers about radiological protection, and (5) Fostering general awareness of proper uses of radiation and radiological protection through education and training of information multipliers. The draft call was discussed with international organisations in formal relations with ICRP in October 2022 at the European Radiation Protection Week in Estoril, Portugal, and the final call announced at the 6th International Symposium on the System of Radiological Protection of ICRP in November 2022 in Vancouver, Canada.


Assuntos
Proteção Radiológica , Humanos , Radiação Ionizante , Canadá , Agências Internacionais
6.
J Radiol Prot ; 42(2)2022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35417898

RESUMO

The International Commission on Radiological Protection (ICRP) has embarked on a process to review and revise the current System of Radiological Protection ('the System'). To stimulate discussion, the ICRP published two open-access articles: one on aspects of the System that might require review, and another on research that might improve the scientific foundation of the System. Building on these articles, the ICRP organized a Workshop on the Future of Radiological Protection as an opportunity to engage in the review and revision of the System. This digital workshop took place from 14 October-3 November 2021 and included 20 live-streamed and 43 on-demand presentations. Approximately 1500 individuals from 100 countries participated. Based on the subjects covered by the presentations, this summary is organized into four broad areas: the scientific basis, concepts and application of the System; and the role of the ICRP. Some of the key topics that emerged included the following: classification of radiation-induced effects; adverse outcome pathway methodologies; better understanding of the dose-response relationship; holistic and reasonable approaches to optimization of protection; radiological protection of the environment; ethical basis of the System; clarity, consistency and communication of the System; application of the System in medicine and application of the principles of justification and optimization of protection.


Assuntos
Lesões por Radiação , Proteção Radiológica , Humanos , Agências Internacionais , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos
7.
Sci Rep ; 11(1): 9756, 2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33963206

RESUMO

Large-scale radiation emergency scenarios involving protracted low dose rate radiation exposure (e.g. a hidden radioactive source in a train) necessitate the development of high throughput methods for providing rapid individual dose estimates. During the RENEB (Running the European Network of Biodosimetry) 2019 exercise, four EDTA-blood samples were exposed to an Iridium-192 source (1.36 TBq, Tech-Ops 880 Sentinal) at varying distances and geometries. This resulted in protracted doses ranging between 0.2 and 2.4 Gy using dose rates of 1.5-40 mGy/min and exposure times of 1 or 2.5 h. Blood samples were exposed in thermo bottles that maintained temperatures between 39 and 27.7 °C. After exposure, EDTA-blood samples were transferred into PAXGene tubes to preserve RNA. RNA was isolated in one laboratory and aliquots of four blinded RNA were sent to another five teams for dose estimation based on gene expression changes. Using an X-ray machine, samples for two calibration curves (first: constant dose rate of 8.3 mGy/min and 0.5-8 h varying exposure times; second: varying dose rates of 0.5-8.3 mGy/min and 4 h exposure time) were generated for distribution. Assays were run in each laboratory according to locally established protocols using either a microarray platform (one team) or quantitative real-time PCR (qRT-PCR, five teams). The qRT-PCR measurements were highly reproducible with coefficient of variation below 15% in ≥ 75% of measurements resulting in reported dose estimates ranging between 0 and 0.5 Gy in all samples and in all laboratories. Up to twofold reductions in RNA copy numbers per degree Celsius relative to 37 °C were observed. However, when irradiating independent samples equivalent to the blinded samples but increasing the combined exposure and incubation time to 4 h at 37 °C, expected gene expression changes corresponding to the absorbed doses were observed. Clearly, time and an optimal temperature of 37 °C must be allowed for the biological response to manifest as gene expression changes prior to running the gene expression assay. In conclusion, dose reconstructions based on gene expression measurements are highly reproducible across different techniques, protocols and laboratories. Even a radiation dose of 0.25 Gy protracted over 4 h (1 mGy/min) can be identified. These results demonstrate the importance of the incubation conditions and time span between radiation exposure and measurements of gene expression changes when using this method in a field exercise or real emergency situation.


Assuntos
Células Sanguíneas/metabolismo , Raios gama/efeitos adversos , Regulação da Expressão Gênica/efeitos da radiação , Laboratórios , Doses de Radiação , Exposição à Radiação , Raios X/efeitos adversos , Relação Dose-Resposta à Radiação , Humanos , Reprodutibilidade dos Testes
8.
Radiat Res ; 195(3): 253-264, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33347576

RESUMO

With the use of ionizing radiation comes the risk of accidents and malevolent misuse. When unplanned exposures occur, there are several methods which can be used to retrospectively reconstruct individual radiation exposures; biological methods include analysis of aberrations and damage of chromosomes and DNA, while physical methods rely on luminescence (TL/OSL) or EPR signals. To ensure the quality and dependability of these methods, they should be evaluated under realistic exposure conditions. In 2019, EURADOS Working Group 10 and RENEB organized a field test with the purpose of evaluating retrospective dosimetry methods as carried out in potential real-life exposure scenarios. A 1.36 TBq 192Ir source was used to irradiate anthropomorphic phantoms in different geometries at doses of several Gy in an outdoor open-air geometry. Materials intended for accident dosimetry (including mobile phones and blood) were placed on the phantoms together with reference dosimeters (LiF, NaCl, glass). The objective was to estimate radiation exposures received by individuals as measured using blood and fortuitous materials, and to evaluate these methods by comparing the estimated doses to reference measurements and Monte Carlo simulations. Herein we describe the overall planning, goals, execution and preliminary outcomes of the 2019 field test. Such field tests are essential for the development of new and existing methods. The outputs from this field test include useful experience in terms of planning and execution of future exercises, with respect to time management, radiation protection, and reference dosimetry to be considered to obtain relevant data for analysis.


Assuntos
Doses de Radiação , Monitoramento de Radiação/métodos , Radiação Ionizante , Humanos , Radioisótopos de Irídio/efeitos adversos , Método de Monte Carlo , Imagens de Fantasmas , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiometria/métodos
9.
Radiat Environ Biophys ; 59(2): 185-209, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32146555

RESUMO

Tissue reactions and stochastic effects after exposure to ionising radiation are variable between individuals but the factors and mechanisms governing individual responses are not well understood. Individual responses can be measured at different levels of biological organization and using different endpoints following varying doses of radiation, including: cancers, non-cancer diseases and mortality in the whole organism; normal tissue reactions after exposures; and, cellular endpoints such as chromosomal damage and molecular alterations. There is no doubt that many factors influence the responses of people to radiation to different degrees. In addition to the obvious general factors of radiation quality, dose, dose rate and the tissue (sub)volume irradiated, recognized and potential determining factors include age, sex, life style (e.g., smoking, diet, possibly body mass index), environmental factors, genetics and epigenetics, stochastic distribution of cellular events, and systemic comorbidities such as diabetes or viral infections. Genetic factors are commonly thought to be a substantial contributor to individual response to radiation. Apart from a small number of rare monogenic diseases such as ataxia telangiectasia, the inheritance of an abnormally responsive phenotype among a population of healthy individuals does not follow a classical Mendelian inheritance pattern. Rather it is considered to be a multi-factorial, complex trait.


Assuntos
Radiação Ionizante , Animais , Humanos , Neoplasias Induzidas por Radiação/epidemiologia , Proteção Radiológica , Tolerância a Radiação
10.
Pol J Vet Sci ; 22(2): 61-65, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31269337

RESUMO

Edible snails are kept in farms in many countries worldwide. As farm animals, they are an object of interest of veterinary studies and applied biology. There is a large demand for tests which would help identify their health and well-being. The objective of this study was to assess the usefulness of determining the concentration of urea in hemolymph as a marker of health of the Lissachatina fulica and Cornu aspersum edible snails. The observation covered snails from four farms marked from A to D, in which numerous deaths (farm A) and decreased body weight gain (farms B and C) were observed. In experimental farm D we observed a group of snails subjected to stress and a control group maintained in correct conditions. High concentrations of urea were found in the hemolymph of all farm animals from farms A, B and C, as well as in those subjected to food deprivation in farm D (on average from 96 mg/dl in farm D to 320 mg/dl in farm A). On the other hand, in controls from group D, the concentration of the parameter in question was much lower (⟨ 2.0 mg/dl). The results obtained indicate that the urea concentration is a non-specific marker of pathological conditions in snails, and that the continuous monitoring of this parameter makes it possible to demonstrate irregularities in farming and introduce appropriate and early measures to eliminate such disturbances.


Assuntos
Hemolinfa/química , Caramujos/fisiologia , Ureia/química , Criação de Animais Domésticos , Animais
11.
Radiat Prot Dosimetry ; 182(1): 128-138, 2018 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30423161

RESUMO

Biological dosimetry enables individual dose reconstruction in the case of unclear or inconsistent radiation exposure situations, especially when a direct measurement of ionizing radiation is not or is no longer possible. To be prepared for large-scale radiological incidents, networking between well-trained laboratories has been identified as a useful approach for provision of the fast and trustworthy dose assessments needed in such circumstances. To this end, various biodosimetry laboratories worldwide have joined forces and set up regional and/or nationwide networks either on a formal or informal basis. Many of these laboratories are also a part of global networks such as those organized by World Health Organization, International Atomic Energy Agency or Global Health Security Initiative. In the present report, biodosimetry networks from different parts of the world are presented, and the partners, activities and cooperation actions are detailed. Moreover, guidance for situational application of tools used for individual dosimetry is given.


Assuntos
Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos/prevenção & controle , Radiometria/métodos , Humanos , Agências Internacionais , Radiação Ionizante
12.
Ann ICRP ; 47(3-4): 126-141, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29648458

RESUMO

In the past few decades, it has become increasingly evident that sensitivity to ionising radiation is variable. This is true for tissue reactions (deterministic effects) after high doses of radiation, for stochastic effects following moderate and possibly low doses, and conceivably also for non-cancer effects such as cardiovascular disease, the causal pathway(s) of which are not yet fully understood. A high sensitivity to deterministic effects is not necessarily correlated with a high sensitivity to stochastic effects. The concept of individual sensitivity to high and low doses of radiation has long been supported by data from patients with certain rare hereditary conditions. However, these syndromes only affect a small proportion of the general population. More relevant to the majority of the population is the notion that some part of the genetic contribution defining radiation sensitivity may follow a polygenic model, which predicts elevated risk resulting from the inheritance of many low-penetrance risk-modulating alleles. Can the different forms of individual radiation sensitivities be inferred from the reaction of cells exposed ex vivo to ionising radiation? Can they be inferred from analyses of individual genotypes? This paper reviews current evidence from studies of late adverse tissue reactions after radiotherapy in potentially sensitive groups, including data from functional assays, candidate gene approaches, and genome-wide association studies. It focuses on studies published in 2013 or later because a comprehensive review of earlier studies was published previously in a report by the UK Advisory Group on Ionising Radiation.


Assuntos
Proteção Radiológica , Tolerância a Radiação , Radiação Ionizante , Relação Dose-Resposta à Radiação , Humanos , Tolerância a Radiação/genética
14.
Transplant Proc ; 48(5): 1767-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27496488

RESUMO

BACKGROUND: The long-term survival of 209 consecutive patients (mean age, 46 ± 15 years) from a single center with ≥1 diagnostic myocardial biopsy after heart transplantation was analyzed. METHODS: Patients were considered as C4d positive if a capillary staining (immunohistochemistry in paraffin samples) was observed in ≥1 myocardial biopsy. Data were analyzed according to pathologic consensus of antibody mediated rejection definition of C4d+ positivity: 2004 definition in group A and the 2013 definition in group B and compared with their respective controls, composed of patients who do not meet those criteria. Age, follow-up time, and number of biopsies were comparable between patients with C4d+ and controls in both groups. Follow-up was 100% complete with mean of observation time 2143 days. RESULTS: During the follow-up period, 62 patients died (group A: C4d+ 32% vs controls 29%; group B: C4d+ 36% vs controls 29% [P = NS]). There were no differences in survival between patients with positive staining and without C4d+ staining when Kaplan-Meier survival curves were compared. CONCLUSIONS: The presence of C4d positive staining in myocardial capillaries of heart biopsies of patients after heart transplantation, as an isolated finding, was not related to worse long-term survival.


Assuntos
Capilares/metabolismo , Complemento C4b/metabolismo , Transplante de Coração/mortalidade , Miocárdio/patologia , Biópsia , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/mortalidade , Humanos , Imuno-Histoquímica , Estimativa de Kaplan-Meier , Transplante de Rim/mortalidade , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Estudos Retrospectivos , Coloração e Rotulagem/métodos
15.
Health Phys ; 106(6): 764-71, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24776911

RESUMO

Large scale radiological emergencies require high throughput techniques of biological dosimetry for population triage in order to identify individuals indicated for medical treatment. The dicentric assay is the "gold standard" technique for the performance of biological dosimetry, but it is very time consuming and needs well trained scorers. To increase the throughput of blood samples, semi-automation of dicentric scoring was investigated in the framework of the MULTIBIODOSE EU FP7 project, and dose effect curves were established in six biodosimetry laboratories. To validate these dose effect curves, blood samples from 33 healthy donors (>10 donors/scenario) were irradiated in vitro with 6°Co gamma rays simulating three different exposure scenarios: acute whole body, partial body, and protracted exposure, with three different doses for each scenario. All the blood samples were irradiated at Ghent University, Belgium, and then shipped blind coded to the participating laboratories. The blood samples were set up by each lab using their own standard protocols, and metaphase slides were prepared to validate the calibration curves established by semi-automatic dicentric scoring. In order to achieve this, 300 metaphases per sample were captured, and the doses were estimated using the newly formed dose effect curves. After acute uniform exposure, all laboratories were able to distinguish between 0 Gy, 0.5 Gy, 2.0, and 4.0 Gy (p < 0.001), and, in most cases, the dose estimates were within a range of ± 0.5 Gy of the given dose. After protracted exposure, all laboratories were able to distinguish between 1.0 Gy, 2.0 Gy, and 4.0 Gy (p < 0.001), and here also a large number of the dose estimates were within ± 0.5 Gy of the irradiation dose. After simulated partial body exposure, all laboratories were able to distinguish between 2.0 Gy, 4.0 Gy, and 6.0 Gy (p < 0.001). Overdispersion of the dicentric distribution enabled the detection of the partial body samples; however, this result was clearly dose-dependent. For partial body exposures, only a few dose estimates were in the range of ± 0.5 Gy of the given dose, but an improvement could be achieved with higher cell numbers. The new method of semi-automation of the dicentric assay was introduced successfully in a network of six laboratories. It is therefore concluded that this method can be used as a high-throughput screening tool in a large-scale radiation accident.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Modelos Biológicos , Radiometria/métodos , Automação , Calibragem , Relação Dose-Resposta à Radiação , Humanos
16.
Radiat Prot Dosimetry ; 159(1-4): 87-94, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24743767

RESUMO

Within the EU MULTIBIODOSE project, the automated micronucleus (MN) assay was optimised for population triage in large-scale radiological emergencies. For MN scoring, two approaches were applied using the Metafer4 platform (MetaSystems, Germany): fully automated scoring and semi-automated scoring with visual inspection of the gallery of MN-positive objects. Dose-response curves were established for acute and protracted whole-body and partial-body exposures. A database of background MN yields was set up, allowing determination of the dose detection threshold in both scoring modes. An analysis of the overdispersion of the MN frequency distribution σ(2)/µ obtained by semi-automated scoring showed that the value of this parameter represents a reliability check of the calculated equivalent total body dose in case the accident overexposure is a partial-body exposure. The elaborated methodology was validated in an accident training exercise. Overall, the semi-automated scoring procedure represents important added value to the automated MN assay.


Assuntos
Planejamento em Desastres/organização & administração , Linfócitos/efeitos da radiação , Testes para Micronúcleos/métodos , Lesões por Radiação/diagnóstico , Monitoramento de Radiação/métodos , Triagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação , Simulação por Computador , Relação Dose-Resposta à Radiação , Feminino , Raios gama , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Lesões por Radiação/sangue , Adulto Jovem
17.
Phys Rev Lett ; 112(12): 120401, 2014 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-24724629

RESUMO

Contextuality is central to both the foundations of quantum theory and to the novel information processing tasks. Despite some recent proposals, it still faces a fundamental problem: how to quantify its presence? In this work, we provide a universal framework for quantifying contextuality. We conduct two complementary approaches: (i) the bottom-up approach, where we introduce a communication game, which grasps the phenomenon of contextuality in a quantitative manner; (ii) the top-down approach, where we just postulate two measures, relative entropy of contextuality and contextuality cost, analogous to existent measures of nonlocality (a special case of contextuality). We then match the two approaches by showing that the measure emerging from the communication scenario turns out to be equal to the relative entropy of contextuality. Our framework allows for the quantitative, resource-type comparison of completely different games. We give analytical formulas for the proposed measures for some contextual systems, showing in particular that the Peres-Mermin game is by order of magnitude more contextual than that of Klyachko et al. Furthermore, we explore properties of these measures such as monotonicity or additivity.

18.
Radiat Environ Biophys ; 53(2): 241-54, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24557539

RESUMO

In the case of a large scale radiation accident high throughput methods of biological dosimetry for population triage are needed to identify individuals requiring clinical treatment. The dicentric assay performed in web-based scoring mode may be a very suitable technique. Within the MULTIBIODOSE EU FP7 project a network is being established of 8 laboratories with expertise in dose estimations based on the dicentric assay. Here, the manual dicentric assay was tested in a web-based scoring mode. More than 23,000 high resolution images of metaphase spreads (only first mitosis) were captured by four laboratories and established as image galleries on the internet (cloud). The galleries included images of a complete dose effect curve (0-5.0 Gy) and three types of irradiation scenarios simulating acute whole body, partial body and protracted exposure. The blood samples had been irradiated in vitro with gamma rays at the University of Ghent, Belgium. Two laboratories provided image galleries from Fluorescence plus Giemsa stained slides (3 h colcemid) and the image galleries from the other two laboratories contained images from Giemsa stained preparations (24 h colcemid). Each of the 8 participating laboratories analysed 3 dose points of the dose effect curve (scoring 100 cells for each point) and 3 unknown dose points (50 cells) for each of the 3 simulated irradiation scenarios. At first all analyses were performed in a QuickScan Mode without scoring individual chromosomes, followed by conventional scoring (only complete cells, 46 centromeres). The calibration curves obtained using these two scoring methods were very similar, with no significant difference in the linear-quadratic curve coefficients. Analysis of variance showed a significant effect of dose on the yield of dicentrics, but no significant effect of the laboratories, different methods of slide preparation or different incubation times used for colcemid. The results obtained to date within the MULTIBIODOSE project by a network of 8 collaborating laboratories throughout Europe are very promising. The dicentric assay in the web based scoring mode as a high throughput scoring strategy is a useful application for biodosimetry in the case of a large scale radiation accident.


Assuntos
Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Comportamento Cooperativo , Internet , Liberação Nociva de Radioativos , Radiometria/métodos , Triagem , Aberrações Cromossômicas/efeitos da radiação , Humanos , Doses de Radiação , Fatores de Tempo
19.
Mutat Res ; 756(1-2): 174-83, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23707243

RESUMO

Mass casualty scenarios of radiation exposure require high throughput biological dosimetry techniques for population triage in order to rapidly identify individuals who require clinical treatment. The manual dicentric assay is a highly suitable technique, but it is also very time consuming and requires well trained scorers. In the framework of the MULTIBIODOSE EU FP7 project, semi-automated dicentric scoring has been established in six European biodosimetry laboratories. Whole blood was irradiated with a Co-60 gamma source resulting in 8 different doses between 0 and 4.5Gy and then shipped to the six participating laboratories. To investigate two different scoring strategies, cell cultures were set up with short term (2-3h) or long term (24h) colcemid treatment. Three classifiers for automatic dicentric detection were applied, two of which were developed specifically for these two different culture techniques. The automation procedure included metaphase finding, capture of cells at high resolution and detection of dicentric candidates. The automatically detected dicentric candidates were then evaluated by a trained human scorer, which led to the term 'semi-automated' being applied to the analysis. The six participating laboratories established at least one semi-automated calibration curve each, using the appropriate classifier for their colcemid treatment time. There was no significant difference between the calibration curves established, regardless of the classifier used. The ratio of false positive to true positive dicentric candidates was dose dependent. The total staff effort required for analysing 150 metaphases using the semi-automated approach was 2 min as opposed to 60 min for manual scoring of 50 metaphases. Semi-automated dicentric scoring is a useful tool in a large scale radiation accident as it enables high throughput screening of samples for fast triage of potentially exposed individuals. Furthermore, the results from the participating laboratories were comparable which supports networking between laboratories for this assay.


Assuntos
Aberrações Cromossômicas/efeitos da radiação , Cromossomos Humanos/efeitos da radiação , Raios gama/efeitos adversos , Laboratórios/normas , Linfócitos/efeitos da radiação , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos/prevenção & controle , Automação , Radioisótopos de Cobalto , Relação Dose-Resposta à Radiação , Europa (Continente) , Humanos
20.
Radiat Prot Dosimetry ; 151(4): 621-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22923244

RESUMO

In Europe, a network for biological dosimetry has been created to strengthen the emergency preparedness and response capabilities in case of a large-scale nuclear accident or radiological emergency. Through the RENEB (Realising the European Network of Biodosimetry) project, 23 experienced laboratories from 16 European countries will establish a sustainable network for rapid, comprehensive and standardised biodosimetry provision that would be urgently required in an emergency situation on European ground. The foundation of the network is formed by five main pillars: (1) the ad hoc operational basis, (2) a basis of future developments, (3) an effective quality-management system, (4) arrangements to guarantee long-term sustainability and (5) awareness of the existence of RENEB. RENEB will thus provide a mechanism for quick, efficient and reliable support within the European radiation emergency management. The scientific basis of RENEB will concurrently contribute to increased safety in the field of radiation protection.


Assuntos
Proteção Radiológica , Liberação Nociva de Radioativos , Defesa Civil , Emergências , Europa (Continente) , Humanos , Liberação Nociva de Radioativos/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA