Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Vet Anaesth Analg ; 50(2): 146-156, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36759290

RESUMO

OBJECTIVE: To evaluate effects of repeated alfaxalone or propofol administration on haematological and serum biochemical variables in cats undergoing radiotherapy. STUDY DESIGN: Prospective, block-randomized, clinical trial. ANIMALS: A group of 39 client-owned cats. METHODS: After butorphanol (0.2 mg kg-1) and midazolam (0.1 mg kg-1) sedation, cats were randomly assigned to receive either alfaxalone or propofol for induction of anaesthesia and sevoflurane maintenance. Cats were anaesthetized daily with the same induction agent for 10-12 days. Complete blood counts, reticulocytes, Heinz body score and serum biochemistry were performed before the first treatment (T1), at T6, T10 and 3 weeks after the final treatment (T21). Cumulative induction agent dose for each cat at each time point was evaluated for an effect on Heinz body score. Data are shown as mean ± standard deviation; p < 0.05. RESULTS: At baseline there were no significant differences in signalment or blood variables between groups. A significant decrease in haematocrit of 2.3% ± 0.77 (p = 0.02) between T1-T6 and T1-T10 [mean 4.1% (± 0.78, p < 0.0001)] was detected, with a significant increase in haematocrit of 2.1% ± 0.80 (p = 0.046) between T6-T21 and 4.0% ± 0.8 (p < 0.001) between T10-T21. Heinz body score significantly increased by 1.86 ± 0.616 (p = 0.013) between T1-T10. In the propofol group, reticulocytes increased significantly between T1-T6 [mean 23,090 µL-1 ± 7670 (p = 0.02)] and T1-T10 [mean 27,440 µL-1 ± 7990 (p = 0.007)]. Mean cumulative dose at T10 was 19.65 mg kg-1 ± 5.3 and 43.4 mg kg-1 ± 14.4 for alfaxalone and propofol, respectively, with no significant effect on Heinz body formation at any time point. CONCLUSIONS AND CLINICAL RELEVANCE: Haematocrit decreased in both groups with recovery after 3 weeks. Repeated alfaxalone and propofol administration was not associated with marked haematological or serum biochemistry changes.


Assuntos
Pregnanodionas , Propofol , Gatos , Animais , Propofol/farmacologia , Sevoflurano , Estudos Prospectivos , Anestesia Intravenosa/veterinária , Pregnanodionas/farmacologia
2.
Clin Cancer Res ; 28(17): 3814-3823, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35421221

RESUMO

PURPOSE: The FLASH effect is characterized by normal tissue sparing without compromising tumor control. Although demonstrated in various preclinical models, safe translation of FLASH-radiotherapy stands to benefit from larger vertebrate animal models. Based on prior results, we designed a randomized phase III trial to investigate the FLASH effect in cat patients with spontaneous tumors. In parallel, the sparing capacity of FLASH-radiotherapy was studied on mini pigs by using large field irradiation. EXPERIMENTAL DESIGN: Cats with T1-T2, N0 carcinomas of the nasal planum were randomly assigned to two arms of electron irradiation: arm 1 was the standard of care (SoC) and used 10 × 4.8 Gy (90% isodose); arm 2 used 1 × 30 Gy (90% isodose) FLASH. Mini pigs were irradiated using applicators of increasing size and a single surface dose of 31 Gy FLASH. RESULTS: In cats, acute side effects were mild and similar in both arms. The trial was prematurely interrupted due to maxillary bone necrosis, which occurred 9 to 15 months after radiotherapy in 3 of 7 cats treated with FLASH-radiotherapy (43%), as compared with 0 of 9 cats treated with SoC. All cats were tumor-free at 1 year in both arms, with one cat progressing later in each arm. In pigs, no acute toxicity was recorded, but severe late skin necrosis occurred in a volume-dependent manner (7-9 months), which later resolved. CONCLUSIONS: The reported outcomes point to the caveats of translating single-high-dose FLASH-radiotherapy and emphasizes the need for caution and further investigations. See related commentary by Maity and Koumenis, p. 3636.


Assuntos
Carcinoma de Células Escamosas , Neoplasias Nasais , Animais , Carcinoma de Células Escamosas/patologia , Gatos , Necrose , Neoplasias Nasais/patologia , Neoplasias Nasais/radioterapia , Neoplasias Nasais/veterinária , Dosagem Radioterapêutica , Suínos , Porco Miniatura
3.
Vet Radiol Ultrasound ; 62(2): 246-254, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33460237

RESUMO

Planning organ at risk volume (PRV) estimates have been reported as methods for sparing organs at risk (OARs) during radiation therapy, especially for hypofractioned and/or dose-escalated protocols. The objectives of this retrospective, analytical, observational study were to evaluate peri-ocular OAR shifts and derive PRVs in a sample of dogs undergoing radiation therapy for periocular tumors. Inclusion criteria were as follows: dogs irradiated for periocular tumors, with 3D-image-guidance and at least four cone-beam CTs (CBCTs) used for position verification, and positioning in a rigid bite block immobilization device. Peri-ocular OARs were contoured on each CBCT and the systematic and random error of the shifts in relation to the planning CT position computed. The formula 1.3×Σ+0.5xσ was used to generate a PRV of each OAR in the dorsoventral, mediolateral, and craniocaudal axis. A total of 30 dogs were sampled, with 450 OARs contoured, and 2145 shifts assessed. The PRV expansion was qualitatively different for each organ (1-4 mm for the dorsoventral and 1-2 mm for the mediolateral and craniocaudal axes). Maximal PRV expansion was ≤4 mm and directional for the majority; most pronounced for corneas and retinas. Findings from the current study may help improve awareness of and minimization of radiation dose in peri-ocular OARs for future canine patients. Because some OARs were difficult to visualize on CBCTs and/ or to delineate on the planning CT, authors recommend that PRV estimates be institution-specific and applied with caution.


Assuntos
Tomografia Computadorizada de Feixe Cônico/veterinária , Imageamento Tridimensional/veterinária , Planejamento da Radioterapia Assistida por Computador/veterinária , Animais , Cães , Tamanho do Órgão , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia Guiada por Imagem/veterinária , Estudos Retrospectivos
4.
Vet Ophthalmol ; 23(4): 596-610, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32281234

RESUMO

Visual impairment from radiation-induced damage can be painful, disabling, and reduces the patient's quality of life. Ocular tissue damage can result from the proximity of ocular organs at risk to irradiated sinonasal target volumes. As toxicity depends on the radiation dose delivered to a certain volume, dose-volume constraints for organs at risk should ideally be known during treatment planning in order to reduce toxicity. Herein, we summarize published ocular toxicity data of dogs irradiated for sinonasal tumors from 36 publications (1976-2018). In particular, we tried to extract a dose guideline for a clinically acceptable rate of ocular toxicity. The side effects to ocular and periocular tissues were reported in 26/36 studies (72%) and graded according to scoring systems (10/26; 39%). With most scoring systems, however, toxicities of different ocular and periocular tissues are summed into one score. Further, the scores were mostly applied in retrospect and lack volume- and dose-data. This incomplete information reflects the crux of the matter for radiation dose tolerance in canine ocular tissues: The published information of the last three decades does not allow formulating dose-volume guidelines. As a start, we can only state that a mean dose of 39 Gy (given in 10 x 4.2 Gy fractions) will lead to loss of vision by one or both eyes, while mean doses of <30 Gy seem to preserve functionality. With a future goal to define tolerated doses and volumes of ocular and periocular tissues at risk, we propose the use of combined ocular toxicity scoring systems.


Assuntos
Doenças do Cão/radioterapia , Olho , Neoplasias dos Seios Paranasais/veterinária , Seios Paranasais , Lesões por Radiação/veterinária , Animais , Cães , Neoplasias dos Seios Paranasais/radioterapia , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/veterinária , Radioterapia de Intensidade Modulada/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA