Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Clin Med ; 13(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38398455

RESUMO

Background: The fetuses of pregnant women affected by anti-Ro/anti-La antibodies are at risk of developing complete atrioventricular heart block (CAVB) and other potentially life-threatening cardiac affections. CAVB can develop in less than 24 h. Treatment with anti-inflammatory drugs and immunoglobulins (IVIG) can restore the normal rhythm if applied in the transition period. Routine weekly echocardiography, as often recommended, will rarely detect emergent AVB. The surveillance of these pregnancies is controversial. Home-monitoring using a hand-held Doppler is a promising new approach. Methods: To obtain an overview of the current practice in Germany, we developed a web-based survey sent by the DEGUM (German Society of Ultrasound in Medicine) to ultrasound specialists. With the intention to evaluate practicability of home-monitoring, we instructed at-risk pregnant women to use a hand-held Doppler in the vulnerable period between 18 and 26 weeks at our university center. Results: There are trends but no clear consensus on surveillance, prophylaxis, and treatment of anti-Ro/La positive pregnant between specialists in Germany. Currently most experts do not offer home-monitoring but have a positive attitude towards its prospective use. Intensified fetal monitoring using a hand-held Doppler is feasible for pregnant women at risk and does not lead to frequent and unnecessary contact with the center. Conclusion: Evidence-based guidelines are needed to optimize the care of anti-Ro/La-positive pregnant women. Individual risk stratification could help pregnancy care of women at risk and is welcmed by most experts. Hand-held doppler monitoring is accepted by patients and prenatal medicine specialists as an option for intensified monitoring and can be included in an algorithm for surveillance.

2.
Diagnostics (Basel) ; 14(3)2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38337754

RESUMO

We aimed to evaluate retrospectively associated anomalies and outcome in prenatal aortic arch anomalies (AAAs). We included ninety patients with aberrant right subclavian artery (ARSA), right aortic arch (RAA) with mirror image branching (RAA-mirror) or aberrant left subclavian artery (RAA-ALSA) and double aortic arch (DAA) between 2011 and 2020. In total, 19/90 (21.1%) had chromosomal anomalies, the highest rate being within the ARSA subgroup (17/46, 37%). All (13/13) of the RAA-mirror subgroup, 10/27 (37.0%) of RAA-ALSA, 13/46 (28.3%) of ARSA and 0/4 within the DAA subgroup had additional intracardiac anomaly. The rate of extracardiac anomalies was 30.7% in RAA-mirror, 28.3% in ARSA, 25.0% in DAA and 22.2% in the RAA-ALSA subgroup. A total of 42/90 (46.7%) had isolated AAAs: three (7.1%) with chromosomal anomalies, all trisomy 21 (3/26, 11.5%) within the ARSA subgroup. Out of 90, 19 (21.1%) were lost to follow-up (FU). Two (2.2%) intrauterine deaths occurred, and six (6.7%) with chromosomal anomalies terminated their pregnancy. In total, 63 (70.0%) were liveborn, 3/63 (4.8%) with severe comorbidity had compassionate care and 3/60 (5.0%) were lost to FU. The survival rate in the intention-to-treat cohort was 53/57 (93%). Forty-one (77.4%) presented with vascular ring/sling, two (4.9%) with RAA-ALSA developed symptoms and one (2.4%) needed an operation. We conclude that intervention due to vascular ring is rarely necessary. NIPT could be useful in isolated ARSA cases without higher a priori risk for trisomy 21 and after exclusion of other anomalies.

3.
Arch Gynecol Obstet ; 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363396

RESUMO

BACKGROUND: Critical aortic stenosis (AS) in fetuses may progress to hypoplastic left heart syndrome (HLHS) with need for postnatal single ventricular (SV) palliation. Fetal aortic valvuloplasty (FAV) is performed to achieve postnatal biventricular (BV) circulation. However, the impact of FAV on fetal myocardial function is difficult to measure. Prediction of postnatal circulatory status and, therefore, counseling is challenging. METHODS: Retrospective study of fetuses with critical AS who underwent FAV. Global Longitudinal Peak Systolic Strain (GLPSS) of the left ventricle (LV) and right ventricle (RV) were retrospectively analyzed before and after intervention. Fisher's Exact Test and Mann-Whitney-U Test were used for univariant statistical analysis. RESULTS: 23 fetuses with critical AS were included. After intervention fetuses demonstrated more negative LV-GLPSS mean values post- vs. pre-intervention (- 5.36% vs. - 1.57%; p < 0.05). RV-GLPSS was decreased in all fetuses, there was no peri-interventional change. 20 fetuses were born alive. Postnatally, 10 had BV and 10 SV circulation. Improved post-interventional LV-GLPSS strain values correlated with BV outcome (p < 0.05). Pre-interventional continuous LV-GLPSS values correlated with postnatal SV vs. BV outcome (p < 0.05). CONCLUSION: In some fetuses, LV myocardial function assessed by speckle tracking echocardiography (STE) improves after FAV. Improved post-interventional LV-GLPSS correlates with biventricular postnatal outcome. Furthermore, pre-interventional LV- and RV-GLPSS correlate with postnatal outcome. Further studies are needed to asses, if pre-interventional STE parameters might predict which fetuses will benefit from FAV with postnatal BV circulation.

4.
J Clin Med ; 12(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37240614

RESUMO

OBJECTIVE: In fetuses with suspicion of congenital heart disease (CHD), assessment by segmental fetal echocardiography is of great importance. This study sought to examine the concordance of expert fetal echocardiography and postnatal MRI of the heart at a high-volume paediatric heart centre. METHODS: The data of two hundred forty-two fetuses have been gathered under the condition of full pre- and postnatal and the presence of a pre- and postnatal diagnosis of CHD. The haemodynamically leading diagnosis was determined for each test person and was then sorted into diagnostic groups. The diagnoses and diagnostic groups were used for the comparison of diagnostic accuracy in fetal echocardiography. RESULTS: All comparisons between the diagnostic methods for detection of congenital heart disease showed an "almost perfect" (Cohen's Kappa > 0.9) strength of agreement for the diagnostic groups. The diagnosis made by prenatal echocardiography showed a sensitivity of 90-100%, a specificity and a negative predictive value of 97-100%, and a positive predictive value of 85-100%. The diagnostic congruence resulted in an "almost perfect" strength of agreement for all evaluated diagnoses (transposition of great arteries, double outlet right ventricle, hypoplastic left heart, tetralogy of Fallot, atrioventricular septal defect). An agreement of Cohen's Kappa > 0.9 was achieved for all groups, with exception of the diagnosis of double outlet right ventricle (0.8) in prenatal echocardiography compared to postnatal echocardiography. This study came to the result of a sensitivity of 88-100%, a specificity and negative predictive value of 97-100%, and a positive predictive value of 84-100%. The performance of cardiac magnetic resonance imaging (MRI) as an additional measure to echocardiography had an added value in the description of the malposition of the great arteries when diagnosed with double outlet right ventricle and in the detailed description of the anatomy of the lung circulation. CONCLUSIONS: Prenatal echocardiography could be shown to be a reliable method for detection of congenital heart disease when regarding the slightly lower accuracy of diagnosis for double outlet right ventricle and right heart anomalies. Furthermore, the impact of examiner experience and the consideration of follow-up examinations for further improvement of diagnosis accuracy may not be underestimated. The main advantage of an additional MRI is the possibility to obtain a detailed anatomic description of the blood vessels of the lung and the outflow tract. The conduction of further studies that include false-negative and false-positive cases, and studies that are not set within the high-risk-group, as well as studies in a less specialized setting, would allow the completion and investigation of possible differences and discrepancies when comparing the results that have been obtained in this study.

5.
J Matern Fetal Neonatal Med ; 36(1): 2203791, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37080921

RESUMO

OBJECTIVE: This study aimed to analyze prenatal diagnosis, perinatal outcomes, and postnatal follow-up in fetuses with ectopia cordis (EC). METHODS: This retrospective analysis accessed 31 patients with EC who were either diagnosed or referred to a tertiary Fetal Medicine centers for EC diagnosis in Brazil, Germany, Italy, and Poland. We analyzed prenatal diagnosis, perinatal outcomes, and follow-up in these patients. RESULTS: Our study included a cohort of 31 fetuses with EC, 4 and 27 of whom had partial and complete protrusion of the heart through a ventral defect in the thoracoabdominal wall, respectively. EC was diagnosed by fetal echocardiography at a mean gestational age of 20.3 ± 8.6 weeks (range, 8-35 weeks). Of the four cases, in which the karyotype was performed, all of them had a normal result (1 - 46,XX and 3 - 46,XY). Five patients showed conotruncal abnormalities and six ventricular septal defects. Termination of pregnancy (TOP) was performed in 15 cases (48%) and seven pregnant women had spontaneous fetal demise (22.5%). Of the seven fetuses that were born alive, four of them died, and three infants underwent surgery. Among these three infants, all of them survived, one was 5 months, 13 years old and 29 years old at the time of study completion. CONCLUSIONS: Ectopia cordis is associated with high mortality rates and intracardiac/extra-cardiac defects. Ventricular septal defects and conotruncal anomalies were the more common intracardiac defects associated with EC. However, in this cohort of fetuses with EC the incidence of PC was lower than reported in the literature.


Assuntos
Ectopia Cordis , Cardiopatias Congênitas , Comunicação Interventricular , Lactente , Humanos , Gravidez , Feminino , Adolescente , Ectopia Cordis/diagnóstico por imagem , Estudos Retrospectivos , Seguimentos , Ultrassonografia Pré-Natal , Diagnóstico Pré-Natal , Cardiopatias Congênitas/diagnóstico
6.
Prenat Diagn ; 43(2): 192-206, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36726284

RESUMO

OBJECTIVE: We aimed to investigate how the presence of fetal anomalies and different X chromosome variants influences Cell-free DNA (cfDNA) screening results for monosomy X. METHODS: From a multicenter retrospective survey on 673 pregnancies with prenatally suspected or confirmed Turner syndrome, we analyzed the subgroup for which prenatal cfDNA screening and karyotype results were available. A cfDNA screening result was defined as true positive (TP) when confirmatory testing showed 45,X or an X-chromosome variant. RESULTS: We had cfDNA results, karyotype, and phenotype data for 55 pregnancies. cfDNA results were high risk for monosomy X in 48/55, of which 23 were TP and 25 were false positive (FP). 32/48 high-risk cfDNA cases did not show fetal anomalies. Of these, 7 were TP. All were X-chromosome variants. All 16 fetuses with high-risk cfDNA result and ultrasound anomalies were TP. Of fetuses with abnormalities, those with 45,X more often had fetal hydrops/cystic hygroma, whereas those with "variant" karyotypes had different anomalies. CONCLUSION: Both, 45,X or X-chromosome variants can be detected after a high-risk cfDNA result for monosomy X. When there are fetal anomalies, the result is more likely a TP. In the absence of fetal anomalies, it is most often an FP or X-chromosome variant.


Assuntos
Ácidos Nucleicos Livres , Síndrome de Down , Síndrome de Turner , Gravidez , Humanos , Feminino , Síndrome de Turner/diagnóstico , Síndrome de Turner/genética , Síndrome de Down/diagnóstico , Estudos Retrospectivos , Cromossomo X , Diagnóstico Pré-Natal/métodos
7.
Arch Gynecol Obstet ; 307(3): 699-708, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36759358

RESUMO

PURPOSE: Right ventricular (RV) function influences the outcome of hypoplastic left heart (HLH) patients. This study aimed to confirm the assumption of prenatal RV remodeling and possible influencing factors of myocardial restructuring using two-dimensional speckle tracking echocardiography (2D STE). METHODS: This is a retrospective cross-sectional cohort study including HLH fetuses and gestational age-matched controls. Based on a four-chamber view, cine loops were stored with 60 frames per second. Global longitudinal peak systolic strain (GLPSS) of the RV was retrospectively determined and compared to healthy controls. Furthermore, HLH subgroups were built according to the presence of left ventricular endocardial fibroelastosis (LV-EFE) and restrictive foramen ovale (FO) to investigate the effect of these compromising factors on myocardial deformation. RESULTS: A total of 41 HLH fetuses and 101 controls were included. Gestational age at fetal assessment was similarly distributed in both groups (controls: 26.0 ± 5.6 weeks vs. HLH: 29.1 ± 5.6 weeks). Relating to RV-GLPSS values, fetuses with HLH demonstrated lower mean values than healthy control fetuses (- 15.65% vs. - 16.80%, p = 0.065). Cases with LV-EFE (n = 11) showed significantly lower mean values compared to such without LV-EFE (n = 30) (RV-GLPSS: - 12.12% vs. - 16.52%, p = 0.003). No significant differences were observed for cases with FO restriction (n = 10). CONCLUSIONS: In HLH the RV undergoes prenatal remodeling, leading to an adaptation of myocardial function to LV conditions. Further explorations by STE should expand knowledge about RV contraction properties in HLH and its impact on surgical outcome.


Assuntos
Ecocardiografia , Síndrome do Coração Esquerdo Hipoplásico , Gravidez , Feminino , Humanos , Lactente , Estudos Retrospectivos , Estudos Transversais , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem
8.
Prenat Diagn ; 43(2): 183-191, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36600414

RESUMO

OBJECTIVE: Omphalocele is known to be associated with genetic anomalies like trisomy 13, 18 and Beckwith-Wiedemann syndrome, but not with Turner syndrome (TS). Our aim was to assess the incidence of omphalocele in fetuses with TS, the phenotype of this association with other anomalies, their karyotype, and the fetal outcomes. METHOD: Retrospective multicenter study of fetuses with confirmed diagnosis of TS. Data were extracted from a detailed questionnaire sent to specialists in prenatal ultrasound. RESULTS: 680 fetuses with TS were included in this analysis. Incidence of small omphalocele in fetuses diagnosed ≥12 weeks was 3.1%. Including fetuses diagnosed before 12 weeks, it was 5.1%. 97.1% (34/35) of the affected fetuses had one or more associated anomalies including increased nuchal translucency (≥3 mm) and/or cystic hygroma (94.3%), hydrops/skin edema (71.1%), and cardiac anomalies (40%). The karyotype was 45,X in all fetuses. Fetal outcomes were poor with only 1 fetus born alive. CONCLUSION: TS with 45,X karyotype but not with X chromosome variants is associated with small omphalocele. Most of these fetuses have associated anomalies and a poor prognosis. Our data suggest an association of TS with omphalocele, which is evident from the first trimester.


Assuntos
Hérnia Umbilical , Síndrome de Turner , Gravidez , Feminino , Humanos , Síndrome de Turner/complicações , Síndrome de Turner/epidemiologia , Síndrome de Turner/genética , Hérnia Umbilical/diagnóstico por imagem , Hérnia Umbilical/epidemiologia , Hérnia Umbilical/genética , Ultrassonografia Pré-Natal , Incidência , Medição da Translucência Nucal , Cariótipo , Edema , Feto , Fenótipo , Aberrações Cromossômicas
9.
Ultraschall Med ; 44(1): e62-e71, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34225376

RESUMO

OBJECTIVES: Prenatal prediction of postnatal univentricular versus biventricular circulation in patients with borderline left ventricle (bLV) remains challenging. This study investigated prenatal fetal echocardiographic parameters and postnatal outcome of patients with a prenatally diagnosed bLV. METHODS: We report a retrospective study of bLV patients at four prenatal centers with a follow-up of one year. BLV was defined as z-scores of the left ventricle (LV) between -2 and -4. Single-ventricle palliation (SVP), biventricular repair (BVR), and no surgical or catheter-based intervention served as the dependent outcome. Prenatal ultrasound parameters were used as independent variables. Cut-off values from receiver operating characteristic curves (ROC) were determined for significant discrimination between outcomes. RESULTS: A total of 54 patients were diagnosed with bLV from 2010 to 2018. All were live births. Out of the entire cohort, 8 (15 %) received SVP, 34 (63 %) BVR, and 12 (22 %) no intervention. There was no significant difference with regard to genetic or extracardiac anomalies. There were significantly more patients with endocardial fibroelastosis (EFE) in the SVP group compared to the BVR group (80 % vs. 10 %), (p < 0.001). Apex-forming LV (100 % vs. 70 %) and lack of retrograde arch flow (20 % vs. 80 %) were associated with no intervention (p < 0.001). With respect to BVR vs. SVP, the LV sphericity index provided the highest specificity (91.7 %) using a cutoff value of ≤ 0.5. CONCLUSION: The majority of bLV patients maintained biventricular circulation. EFE, retrograde arch flow, and LV sphericity can be helpful parameters for counseling parents and further prospective studies can be developed.


Assuntos
Ecocardiografia , Ventrículos do Coração , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Ecocardiografia/métodos , Curva ROC , Ultrassonografia Pré-Natal/métodos
10.
Ultraschall Med ; 44(4): e175-e183, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35304733

RESUMO

AIM OF THE STUDY: The aim of the study is to examine the detection rates of malformations before and after the introduction of extended basic screening in Hesse by the Federal Joint Committee (Gemeinsamer Bundesausschuss, GQH) on July 1, 2013. METHOD: This is a retrospective, mainly exploratory data analysis of quality assurance data from the Office for Quality Assurance in Hesse (GQH). The data was collected in the period from January 1, 2010 to December 31, 2016 in the obstetric departments of the Hessian hospitals using documentation forms. The classification and evaluation of the diagnoses is based on ICD-10-GM-2019. RESULTS: At least one malformation is present in 0.7% of the cases. With a share of 30.0%, most of the congenital malformations are from the musculoskeletal system. 12.2% of the malformations come from the facial cleft, closely followed by malformations of the circulatory system with 11.3%. The highest prenatal detection rate (PDR) is found in congenital malformations of the nervous system at 56.8%. The lowest PDR is found in those of the genital organs with 2.1%. The PDR of cardiovascular malformations is 32.9%. Overall, a PDR of 25.2% is achieved. There was no change in the number of prenatal malformation diagnoses after the introduction of extended basic ultrasound. The distribution of malformation diagnoses not detected prenatally to the organ systems also has not changed after the introduction. CONCLUSION: The introduction of extended basic ultrasound did not bring the desired improvement with regard to the PDR in Hesse. Alternative approaches should be considered.


Assuntos
Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal , Humanos , Gravidez , Feminino , Estudos Retrospectivos , Ultrassonografia
11.
J Clin Med ; 11(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36498602

RESUMO

Magnetic Resonance Imaging (MRI) is a reliable method, with a complementary role to Ultrasound (US) Echocardiography, that can be used to fully comprehend and precisely diagnose congenital cardiac malformations. Besides the anatomical study of the fetal cardiovascular system, it allows us to study the function of the fetal heart, remaining, at the same time, a safe adjunct to the classic fetal echocardiography. MRI also allows for the investigation of cardiac and placental diseases by providing information about hematocrit, oxygen saturation, and blood flow in fetal vessels. It is crucial for fetal medicine specialists and pediatric cardiologists to closely follow the advances of fetal cardiac MRI in order to provide the best possible care. In this review, we summarize the advance in techniques and their practical utility to date.

12.
J Clin Med ; 11(24)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36556157

RESUMO

Introduction: Twin anemia-polycythemia sequence (TAPS) is a complication in monochorionic-diamniotic (MCDA) twin pregnancies. This study analyzes whether the prenatal diagnosis using delta middle cerebral artery-peak systolic velocity (MCA-PSV) > 0.5 multiples of the median (MoM) (delta group) detects more TAPS cases than the guideline-based diagnosis using the MCA-PSV cut off levels of >1.5 and <1.0 MoM (cut-off group), in a heterogenous group of MCDA twins. Methods: A retrospective analysis of 348 live-born MCDA twin pregnancies from 2010 to 2021 with available information on MCA-PSV within one week before delivery and hemoglobin-values within 24 h postnatally were considered eligible. Results: Among postnatal confirmed twin pairs with TAPS, the cut-off group showed lower sensitivity than the delta group (33% vs. 82%). Specificity proved higher in the cut-off group with 97% than in the delta group at 86%. The risk that a TAPS is mistakenly not recognized prenatally is higher in the cut-off group than in the delta group (52% vs. 18%). Conclusions: Our data shows that delta MCA-PSV > 0.5 MoM detects more cases of TAPS, which would not have been diagnosed prenatally according to the current guidelines. In the collective examined in the present study, TAPS diagnostics using delta MCA-PSV proved to be a more robust method.

13.
J Clin Med ; 11(15)2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35956203

RESUMO

Mirror syndrome is a rare and serious maternal condition associated with immune and non-immune fetal hydrops after 16 weeks of gestational age. Subjacent conditions associated with fetal hydrops may carry different risks for Mirror syndrome. Fetuses with Turner syndrome are frequently found to be hydropic on ultrasound. We designed a retrospective multicenter study to evaluate the risk for Mirror syndrome among pregnancies complicated with Turner syndrome and fetal hydrops. Data were extracted from a questionnaire sent to specialists in maternal fetal medicine in Germany. Out of 758 cases, 138 fulfilled our inclusion criteria and were included in the analysis. Of the included 138, 66 presented with persisting hydrops at or after 16 weeks. The frequency of placental hydrops/placentomegaly was rather low (8.1%). Of note, no Mirror syndrome was observed in our study cohort. We propose that the risk of this pregnancy complication varies according to the subjacent cause of fetal hydrops. In Turner syndrome, the risk for Mirror syndrome is lower than that reported in the literature. Our observations are relevant for clinical management and parental counseling.

14.
Ultraschall Med ; 43(6): e90-e97, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32674186

RESUMO

OBJECTIVE: Criss-cross heart (CCH) is a rare congenital cardiac defect defined by crossing of ventricular inflow streams contributing to less than 0.1 % of all congenital heart anomalies. Due to its rarity and complexity, prenatal diagnosis in these patients remains challenging. We sought to describe prenatal findings and postnatal course in eight cases of prenatally diagnosed CCH. METHODS: This is a retrospective case series of prenatally diagnosed CCH in three centers between 2010-2017. We reviewed fetal echocardiograms as well as postnatal clinical charts and surgical reports. RESULTS: 8 cases of CCH were included. The median gestational age at diagnosis was 27 weeks. 7 patients were found with situs solitus, one fetus with situs ambiguous. In all patients, the four-chamber view was abnormal. There was atrioventricular discordance in half of the patients, while all patients showed ventriculoarterial discordance. All patients were found with additional cardiac anomalies, including ventricular septal defect, double outlet right ventricle, right aortic arch, atrial septal defect and pulmonary stenosis. Three patients underwent amniocentesis without pathological findings. All patients were born alive at a median gestational age of 38 + 2 weeks and survived our median follow-up of 181 days. CONCLUSION: CCH can be diagnosed prenatally by detailed fetal echocardiography when observing an abnormal four-chamber view with crossing of inflow streams into both ventricles and a lack of parallel orientation of the atrioventricular valve axis due to a clockwise or counterclockwise rotation of the ventricular mass along its axis. With the help of prenatal ultrasound, parental guidance and counselling as well as postnatal pediatric cardiac management can be warranted.


Assuntos
Coração Entrecruzado , Dupla Via de Saída do Ventrículo Direito , Cardiopatias Congênitas , Comunicação Interventricular , Feminino , Humanos , Gravidez , Criança , Lactente , Coração Entrecruzado/diagnóstico por imagem , Estudos Retrospectivos , Dupla Via de Saída do Ventrículo Direito/cirurgia , Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal , Cardiopatias Congênitas/diagnóstico por imagem , Estudos Multicêntricos como Assunto
15.
Genes (Basel) ; 12(4)2021 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-33805390

RESUMO

In 1959, 63 years after the death of John Langdon Down, Jérôme Lejeune discovered trisomy 21 as the genetic reason for Down syndrome. Screening for Down syndrome has been applied since the 1960s by using maternal age as the risk parameter. Since then, several advances have been made. First trimester screening, combining maternal age, maternal serum parameters and ultrasound findings, emerged in the 1990s with a detection rate (DR) of around 90-95% and a false positive rate (FPR) of around 5%, also looking for trisomy 13 and 18. With the development of high-resolution ultrasound, around 50% of fetal anomalies are now detected in the first trimester. Non-invasive prenatal testing (NIPT) for trisomy 21, 13 and 18 is a highly efficient screening method and has been applied as a first-line or a contingent screening approach all over the world since 2012, in some countries without a systematic screening program. Concomitant with the rise in technology, the possibility of screening for other genetic conditions by analysis of cfDNA, such as sex chromosome anomalies (SCAs), rare autosomal anomalies (RATs) and microdeletions and duplications, is offered by different providers to an often not preselected population of pregnant women. Most of the research in the field is done by commercial providers, and some of the tests are on the market without validated data on test performance. This raises difficulties in the counseling process and makes it nearly impossible to obtain informed consent. In parallel with the advent of new screening technologies, an expansion of diagnostic methods has begun to be applied after invasive procedures. The karyotype has been the gold standard for decades. Chromosomal microarrays (CMAs) able to detect deletions and duplications on a submicroscopic level have replaced the conventional karyotyping in many countries. Sequencing methods such as whole exome sequencing (WES) and whole genome sequencing (WGS) tremendously amplify the diagnostic yield in fetuses with ultrasound anomalies.


Assuntos
Transtornos Cromossômicos/diagnóstico , Testes Genéticos/métodos , Análise em Microsséries/métodos , Diagnóstico Pré-Natal/métodos , Transtornos Cromossômicos/genética , Feminino , Humanos , Gravidez
16.
Arch Gynecol Obstet ; 304(1): 81-90, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33585987

RESUMO

OBJECTIVES: To analyse prenatal parameters predicting biventricular (BV) outcome in pulmonary atresia with intact ventricular septum/critical pulmonary stenosis (PAIVS/CPS). METHODS: We evaluated 82 foetuses from 01/08 to 10/18 in 3 centres in intervals 1 (< 24 weeks), 2 (24-30 weeks) and 3 (> 30 weeks). RESULTS: 61/82 (74.4%) were livebirths, 5 (8.2%) lost for follow-up, 3 (4.9%) had compassionate care leaving 53 (64.6% of the whole cohort and 86.9% of livebirths) with intention to treat. 9 died, 44/53 (83.0%) survived. 24/38 (63.2%) with information on postnatal outcome had BV outcome, 14 (36.8%) non-BV outcome (2 × 1.5 circulation). One with BV outcome had prenatal valvuloplasty. Best single parameter for BV outcome was tricuspid/mitral valve (TV/MV) ratio (AUC 0.93) in intervals 2 and 3 (AUC 0.92). Ventriculo-coronary-arterial communications (VCAC) were present in 11 (78.6%) in non-BV outcome group vs. 2 (8.3%) in BV outcome group (p < 0.001). Tricuspid insufficiency (TI)-Vmax > 2.5 m/s was present in BV outcome group in75.0% (18/24) vs. 14.3% (2/14) in non-BV outcome group. Including the most predictive markers (VCAC presence, TI- Vmax < 2.5 m/s, TV/MV ratio < cutoff) to a score, non-BV outcome was correctly predicted when > 1 criterion was fulfilled in all cases. After recently published criteria for foetal intervention, only 4/9 (44.4%) and 5/14 (35.7%) in our interval 2 + 3 with predicted non-BV outcome would have been candidates for intervention. Two (1 × intrauterine intervention) in interval 2, two in interval 3 reached BV outcome and one 1.5 circulation without intervention. CONCLUSION: TV/MV ratio as simple parameter has high predictive value. After our score, non-BV outcome was correctly predicted in all cases. Criteria for foetal intervention must further be evaluated.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Atresia Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Ecocardiografia , Feminino , Humanos , Masculino , Gravidez , Resultado da Gravidez , Diagnóstico Pré-Natal , Atresia Pulmonar/cirurgia , Estenose da Valva Pulmonar/congênito , Resultado do Tratamento
17.
Ultraschall Med ; 42(3): 291-296, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31995816

RESUMO

OBJECTIVE: Congenital corrected transposition of the great arteries (ccTGA) is a rare congenital cardiac anomaly which remains difficult to diagnose prenatally. We aim to investigate the natural history, associated anomalies and the outcome of patients in prenatally diagnosed ccTGA. METHOD: This was an international multicenter retrospective analysis of fetuses with a diagnosis of ccTGA from 2002 to 2017. We reviewed clinical and echocardiographic databases of seven centers. Anatomic survey and fetal echocardiography were performed according to international guidelines of ISUOG. RESULTS: We considered 69 fetuses with prenatally suspected ccTGA. There was an overall survival rate of 91 % among 54 patients with a confirmed diagnosis. Survival to live birth was 96 % (52/54) and survival on an intention-to-treat basis was 94 % (49/52). The mean gestational age at the time of diagnosis was 25.6 ±â€Š5.9 weeks of gestation. In 7 out of 54 fetuses (13 %), ccTGA was an isolated finding. Dextro/mesocardia was present in 15 cases (27.8 %). Intracardiac anomalies were present in 46/54 cases (85.2 %) with the most frequent anomaly being a ventricular septal defect present in 41 fetuses (75.9 %). Complete heart block was diagnosed in 10 cases (18.5 %). Extracardiac anomalies were observed in 9 out of 54 cases (16.7 %). Prenatal karyotyping of the fetus was available in 30/54 (55.6 %) cases with chromosomal anomalies in 4/30 (13.3 %). CONCLUSION: ccTGA is a rare cardiac anomaly often accompanied by a variable spectrum of further intracardiac abnormalities. Accurate diagnosis of ccTGA, which can be integrated into parental counselling, is feasible with a favorable short-term outcome for affected neonates.


Assuntos
Cardiopatias Congênitas , Transposição dos Grandes Vasos , Artérias , Feminino , Humanos , Recém-Nascido , Gravidez , Diagnóstico Pré-Natal , Estudos Retrospectivos , Transposição dos Grandes Vasos/diagnóstico por imagem , Ultrassonografia Pré-Natal
18.
Ultraschall Med ; 42(1): 48-55, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31200391

RESUMO

PURPOSE: Children with congenital heart disease (CHD) are known to have impaired neurodevelopment possibly influenced by altered cerebroplacental hemodynamics antenatally. We compared fetomaternal Doppler patterns in different CHD groups with published normative values during gestation. MATERIALS AND METHODS: Retrospective cohort study consisting of 248 CHD fetuses. Subgroups were generated according to the expected ascending aorta oxygen saturation: low portion of high oxygenated umbilical venous (UV) blood (group 1: n = 108), intermediate portion of UV blood due to intracardiac mixing with oxygen poor systemic blood (group 2: n = 103), high (group 3: n = 13) and low portion of UV blood without mixing of blood (group 4: n = 24). Doppler examination included umbilical artery and middle cerebral artery pulsatility index (UA-PI, MCA-PI), cerebroplacental ratio (CPR) and mean uterine artery (mUtA) PI. For mean comparisons at different gestational ages (GA), estimated marginal means from regression models are reported for GA 22 weeks (wks), GA 30 wks and GA 38 wks. RESULTS: Z-score transformed values of MCA-PI (zMCA-PI) were significantly lower in group 1 compared to all other subgroups at GA 30 wks (p < 0.05). At 38 wks, group 1 had significantly lower values of zMCA-PI and zCPR compared to groups 2 and 4. Group 1 fetuses showed a significant association between zMCA-PI and zCPR (negative) and GA as well as zmUtA-PI (positive) and GA compared to reference values. CONCLUSION: Our data confirm that CHD fetuses have a higher rate of cerebral redistribution in the third trimester. Changes in Doppler patterns were mainly observed in CHD with a low portion of UV blood in the ascending aorta.


Assuntos
Cardiopatias Congênitas , Ultrassonografia Pré-Natal , Criança , Feminino , Desenvolvimento Fetal , Feto , Idade Gestacional , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Gravidez , Fluxo Pulsátil , Estudos Retrospectivos , Ultrassonografia Doppler , Artérias Umbilicais/diagnóstico por imagem
19.
Fetal Diagn Ther ; 47(9): 699-710, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32615558

RESUMO

OBJECTIVE: Two-dimensional speckle tracking echocardiography (2D-STE)-based strain values of the left and the right ventricle have been established; however, less is known about atrial deformation. The aim of our study was to assess both atrial strain and ventricular strain using 2D-STE in a cardiac 4-chamber view and to investigate the effect of possible influencing factors such as gestational age. METHODS: Fetal echocardiography was performed on a Toshiba Aplio 500 ultrasound system. Based on an apical or basal 4-chamber view of the fetal heart, left and right ventricular longitudinal peak systolic strain (LVLPSS and RVLPSS) as well as left and right atrial longitudinal peak systolic strain (LALPSS and RALPSS) were assessed by 2D-STE. RESULTS: A total of 101 healthy fetuses were included. The mean gestational age (GA) was 26.0 ± 5.6 weeks. GA was significantly positively correlated (p < 0.05) with LVLPSS and RVLPSS and significantly negatively correlated (p < 0.05) with LALPSS and RALPSS. The mean values for LVLPSS and RVLPSS were -17.44 ± 2.29% and -16.89 ± 1.72%. The mean values for LALPSS and RALPSS were 34.09 ± 4.17% and 35.36 ± 2.90%. CONCLUSION: Ventricular and atrial deformation analysis in 2D-STE was technically feasible and showed comparable values to current data. For future research on myocardial function (MF) of the fetus, considering GA as an influencing factor for deformation analysis seems to be adequate. Especially, atrial deformation analysis allows the assessment of diastolic myocardial function. Further research needs to clarify the clinical meaning of these myocardial deformation indices in fetuses at risk.


Assuntos
Coração Fetal/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Idade Gestacional , Humanos , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA