RESUMO

Management and closure of contaminated sites is increasingly being proposed on the basis of mass flux of dissolved contaminants in groundwater. Better understanding of the links between source mass removal and contaminant mass fluxes in groundwater would allow greater acceptance of this metric in dealing with contaminated sites. Our objectives here were to show how measurements of the distribution of contaminant mass flux and the overall mass discharge emanating from the source under undisturbed groundwater conditions could be related to the processes and extent of source mass depletion. In addition, these estimates of mass discharge were sought in the application of agreed remediation targets set in terms of pumped groundwater quality from offsite wells. Results are reported from field studies conducted over a 5-year period at a brominated DNAPL (tetrabromoethane, TBA; and tribromoethene, TriBE) site located in suburban Perth, Western Australia. Groundwater fluxes (qw; L(3)/L(2)/T) and mass fluxes (Jc; M/L(2)/T) of dissolved brominated compounds were simultaneously estimated by deploying Passive Flux Meters (PFMs) in wells in a heterogeneous layered aquifer. PFMs were deployed in control plane (CP) wells immediately down-gradient of the source zone, before (2006) and after (2011) 69-85% of the source mass was removed, mainly by groundwater pumping from the source zone. The high-resolution (26-cm depth interval) measures of qw and Jc along the source CP allowed investigation of the DNAPL source-zone architecture and impacts of source mass removal. Comparable estimates of total mass discharge (MD; M/T) across the source zone CP reduced from 104gday(-1) to 24-31gday(-1) (70-77% reductions). Importantly, this mass discharge reduction was consistent with the estimated proportion of source mass remaining at the site (15-31%). That is, a linear relationship between mass discharge and source mass is suggested. The spatial detail of groundwater and mass flux distributions also provided further evidence of the source zone architecture and DNAPL mass depletion processes. This was especially apparent in different mass-depletion rates from distinct parts of the CP. High mass fluxes and groundwater fluxes located near the base of the aquifer dominated in terms of the dissolved mass flux in the profile, although not in terms of concentrations. Reductions observed in Jc and MD were used to better target future remedial efforts. Integration of the observations from the PFM deployments and the source mass depletion provided a basis for establishing flux-based management criteria for the site.


Assuntos
Monitoramento Ambiental/métodos , Recuperação e Remediação Ambiental/métodos , Água Subterrânea , Hidrocarbonetos Bromados/química , Poluentes Químicos da Água/química , Poluentes Químicos da Água/análise , Austrália Ocidental
2.
J Contam Hydrol ; 144(1): 122-37, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23247401

RESUMO

Mass depletion-mass flux relationships usually applied to a groundwater plume were established at field scale for groundwater pumped from within the source zone of a dense non-aqueous phase liquid (DNAPL). These were used as part of multiple lines of evidence in establishing the DNAPL source mass and architecture. Simplified source mass-dissolved concentration models including those described by exponential, power, and error functions as well as a rational mass equation based on the equilibrium stream tube approach were fitted to data from 285 days of source zone pumping (SZP) from a single well which removed 152 kg of dissolved organics from a multi-component, reactive brominated solvent DNAPL. The total molar concentration of the source compound, tetrabromoethane and its daughter products was used as a single measure of contaminant concentration to relate to source mass. A partitioning inter-well tracer test (PITT) conducted prior to the SZP provided estimates of groundwater travel times, enabling parameterisation of the models. After accounting for capture of the down-gradient dissolved plume, all models provided a good fit to the observed data. It was shown that differentiation between models would only emerge after appreciably more pumping from the source zone. The model fits were not particularly sensitive to the exponent parameters and variance of groundwater travel time. In addition, the multi-component nature of the DNAPL did not seem to affect the utility of the models for the period examined. Estimates of the DNAPL mass prior to the start of SZP from the models were greatest where the log of the variance of travel time was used explicitly in the source depletion models (mean 295kg) compared to where the associated power exponent and variance was fitted freely (mean 258 kg). The estimates of source mass were close to that of 220kg determined from the PITT. In addition to the PITT, multi-level groundwater sampling from within the source zone provided important supporting information for developing the conceptual model of the source zone. It is concluded that SZP may be an effective and relatively simple means for characterising DNAPL source zones.


Assuntos
Monitoramento Ambiental/métodos , Água Subterrânea , Modelos Teóricos , Poluentes Químicos da Água/análise , Halogenação , Modelos Químicos , Fatores de Tempo , Poluentes Químicos da Água/química , Austrália Ocidental