Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Innovations (Phila) ; : 15569845241264565, 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39205530

RESUMO

We convened a group of cardiac surgeons, intensivists, and anesthesiologists with extensive experience in minimally invasive cardiac surgery (MICS) and perioperative care to identify the essential elements of a MICS program and the relationship with Enhanced Recovery After Surgery (ERAS). The MICS incision should minimize tissue invasion without compromising surgical goals. MICS also requires safe management of hemodynamics and preservation of cardiac function, which we have termed myocardial management. Finally, comprehensive perioperative care through an ERAS program should be provided to allow patients to achieve optimal recovery. Therefore, we propose that MICS requires 3 elements: (1) a less invasive surgical incision (non-full sternotomy), (2) optimized myocardial management, and (3) ERAS. We contend that the full benefit of MICS can be achieved only by also utilizing an ERAS platform.

2.
Ann Thorac Surg ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38723881

RESUMO

BACKGROUND: To provide patients and surgeons with clinically relevant information, The Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database was queried to develop a risk model for isolated tricuspid valve (TV) operations. METHODS: All patients in the STS Adult Cardiac Surgery Database who had undergone isolated TV repair or replacement (N = 13,587; age 48.3 ± 18.4 years) were identified (July 2017 to June 2023). Multivariable logistic regression accounting for TV replacement vs repair was used to model 8 operative outcomes: mortality, morbidity or mortality or both, stroke, renal failure, reoperation, prolonged ventilation, short hospital stay, and prolonged hospital stay. Model discrimination (C-statistic) and calibration were assessed using 9-fold cross-validation. RESULTS: The isolated TV study population included 41.1% repairs (N = 5,583; age 52.6 ± 18.1 years) and 58.9% replacements (N = 8,004; age 45.3 ± 18.0 years). The overall predicted risk of operative mortality was 5.6%, and it was similar in TV repairs and replacements (5.5% and 5.7%, respectively), as was the predicted risk of composite morbidity and mortality (28.2% and 26.8%). TV replacements were generally performed in younger patients with a higher endocarditis prevalence than TV repairs (45.7% vs 21.1%). The model yielded a C-statistic of 0.81 for mortality and 0.76 for the composite of morbidity and mortality, with excellent observed-to-expected calibration that was comparable in all subcohorts and predicted risk decile groups. CONCLUSIONS: An STS risk model has been developed for isolated TV surgery. The current mortality of isolated TV operations is lower than previously observed. This risk prediction model and these contemporary outcomes provide a new benchmark for current and future isolated TV interventions.

3.
Cardiovasc Revasc Med ; 65: 25-31, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38467531

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly performed for the treatment of aortic stenosis. Computed tomography (CT) analysis is essential for pre-procedural planning. Currently available software packages for TAVR planning require substantial human interaction. We describe development and validation of an artificial intelligence (AI) powered software to automatically rend anatomical measurements and other information required for TAVR planning and implantation. METHODS: Automated measurements from 100 CTs were compared to measurements from three expert clinicians and TAVR operators using commercially available software packages. Correlation coefficients and mean differences were calculated to assess precision and accuracy. RESULTS: AI-generated annular measurements had excellent agreements with manual measurements by expert operators yielding correlation coefficients of 0.97 for both perimeter and area. There was no relevant bias with a mean difference of -0.07 mm and - 1.4 mm2 for perimeter and area, respectively. For the ascending aorta measured 5 cm above the annular plane, correlation coefficient was 0.95 and mean difference was 1.4 mm. Instruction for use-based sizing yielded agreement with the effective implant size in 87-88 % of patients for self-expanding valves (perimeter-based sizing) and in 88 % for balloon-expandable valves (area-based sizing). CONCLUSIONS: A fully automated software enables accurate and precise anatomical segmentation and measurements required for TAVR planning without human interaction and with high reliability.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Inteligência Artificial , Automação , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Substituição da Valva Aórtica Transcateter/instrumentação , Reprodutibilidade dos Testes , Próteses Valvulares Cardíacas , Desenho de Prótese , Variações Dependentes do Observador , Validação de Programas de Computador , Tomografia Computadorizada Multidetectores
4.
Ann Thorac Surg ; 118(2): 291-310, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38286206

RESUMO

The Society of Thoracic Surgeons 2023 Clinical Practice Guidelines for the Surgical Treatment of Atrial Fibrillation incorporate the most recent evidence for surgical ablation and left atrial appendage occlusion in different clinical scenarios. Substantial new evidence regarding the risks and benefits of surgical left atrial appendage occlusion and the long-term benefits of surgical ablation has been produced in the last 5 years. Compared with the 2017 clinical practice guideline, the current update has an emphasis on surgical ablation in first-time, nonemergent cardiac surgery and its long-term benefits, an extension of the recommendation to perform surgical ablation in all patients with atrial fibrillation undergoing first-time, nonemergent cardiac surgery, and a new class I recommendation for left atrial appendage occlusion in all patients with atrial fibrillation undergoing first-time, nonemergent cardiac surgery. Further guidance is provided for patients with structural heart disease and atrial fibrillation being considered for transcatheter valve repair or replacement, as well as patients in need of isolated left atrial appendage management who are not candidates for surgical ablation. The importance of a multidisciplinary team assessment, treatment planning, and long-term follow-up are reiterated in this clinical practice guideline with a class I recommendation, along with the other recommendations from the 2017 guidelines that remained unchanged in their class of recommendation and level of evidence.


Assuntos
Fibrilação Atrial , Sociedades Médicas , Fibrilação Atrial/cirurgia , Humanos , Cirurgia Torácica , Apêndice Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/normas , Ablação por Cateter/métodos
6.
Ann Thorac Surg ; 117(2): 260-270, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040323

RESUMO

The Society of Thoracic Surgeons (STS) Adult Cardiac Surgery Database is one of the largest and most comprehensive contemporary clinical databases in use. It now contains >9 million procedures from 1010 participants and 3651 active surgeons. Using audited data collection, it has provided the foundation for multiple risk models, performance metrics, health policy decisions, and a trove of research studies to improve the care of patients in need of cardiac surgical procedures. This annual report provides an update on the current status of the database and summarizes the development of new risk models and the STS Online Risk Calculator. Further, it provides insights into current practice patterns, such as the change in the demographics among patients undergoing aortic valve replacement, the use of minimally invasive techniques for valve and bypass surgery, or the adoption of surgical ablation and left atrial appendage ligation among patients with atrial fibrillation. Lastly, an overview of the research conducted using the STS Adult Cardiac Surgery Database and future directions for the database are provided.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgiões , Cirurgia Torácica , Adulto , Humanos , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Bases de Dados Factuais , Sociedades Médicas
8.
Eur J Heart Fail ; 25(3): 399-410, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36883620

RESUMO

AIMS: This study aimed to compare outcomes after transcatheter mitral valve replacement (TMVR) and mitral valve transcatheter edge-to-edge repair (M-TEER) for the treatment of secondary mitral regurgitation (SMR). METHODS AND RESULTS: The CHOICE-MI registry included 262 patients with SMR treated with TMVR between 2014 and 2022. The EuroSMR registry included 1065 patients with SMR treated with M-TEER between 2014 and 2019. Propensity score (PS) matching was performed for 12 demographic, clinical and echocardiographic parameters. Echocardiographic, functional and clinical outcomes out to 1 year were compared in the matched cohorts. After PS matching, 235 TMVR patients (75.5 years [70.0, 80.0], 60.2% male, EuroSCORE II 6.3% [interquartile range 3.8, 12.4]) were compared to 411 M-TEER patients (76.7 years [70.1, 80.5], 59.0% male, EuroSCORE II 6.7% [3.9, 12.4]). All-cause mortality was 6.8% after TMVR and 3.8% after M-TEER at 30 days (p = 0.11), and 25.8% after TMVR and 18.9% after M-TEER at 1 year (p = 0.056). No differences in mortality after 1 year were found between both groups in a 30-day landmark analysis (TMVR: 20.4%, M-TEER: 15.8%, p = 0.21). Compared to M-TEER, TMVR resulted in more effective mitral regurgitation (MR) reduction (residual MR ≤1+ at discharge for TMVR vs. M-TEER: 95.8% vs. 68.8%, p < 0.001), and superior symptomatic improvement (New York Heart Association class ≤II at 1 year: 77.8% vs. 64.3%, p = 0.015). CONCLUSION: In this PS-matched comparison between TMVR and M-TEER in patients with severe SMR, TMVR was associated with superior reduction of MR and superior symptomatic improvement. While post-procedural mortality tended to be higher after TMVR, no significant differences in mortality were found beyond 30 days.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Pontuação de Propensão , Resultado do Tratamento , Cateterismo Cardíaco/métodos
12.
JACC Case Rep ; 4(22): 1459-1463, 2022 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-36444179

RESUMO

A 67-year-old woman with prior transcatheter aortic valve replacement presented with worsening dyspnea. Imaging revealed transcatheter aortic valve thrombosis and aortic stenosis. Despite oral anticoagulation, she progressively deteriorated and developed cardiogenic shock. We highlight the Heart Team's role in treating this unusual late thrombosis. (Level of Difficulty: Intermediate.).

16.
Ann Thorac Surg ; 113(2): 511-518, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33844993

RESUMO

BACKGROUND: The Society of Thoracic Surgeons (STS) Quality Measurement Task Force has developed risk models and composite performance measures for isolated coronary artery bypass grafting (CABG), isolated aortic valve replacement (AVR), isolated mitral valve replacement or repair (MVRR), AVR+CABG, and MVRR+CABG. To further enhance its portfolio of risk-adjusted performance metrics, STS has developed new risk models for multiple valve operations ± CABG procedures. METHODS: Using July 2011 to June 2019 STS Adult Cardiac Surgery Database data, risk models for AVR+MVRR (n = 31,968) and AVR+MVRR+CABG (n = 12,650) were developed with the following endpoints: Operative Mortality, major morbidity (any 1 or more of the following: cardiac reoperation, deep sternal wound infection/mediastinitis, stroke, prolonged ventilation, and renal failure), and combined mortality and/or major morbidity. Data were divided into development (July 2011 to June 2017; n = 35,109) and validation (July 2017 to June 2019; n = 9509) samples. Predictors were selected by assessing model performance and clinical face validity of full and progressively more parsimonious models. Performance of the resulting models was evaluated by assessing discrimination and calibration. RESULTS: C-statistics for the overall population of multiple valve ± CABG procedures were 0.7086, 0.6734, and 0.6840 for mortality, morbidity, and combined mortality and/or morbidity in the development sample, and 0.6953, 0.6561, and 0.6634 for the same outcomes, respectively, in the validation sample. CONCLUSIONS: New STS Adult Cardiac Surgery Database risk models have been developed for multiple valve ± CABG operations, and these models will be used in subsequent STS performance metrics.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Modelos Estatísticos , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Sociedades Médicas , Cirurgia Torácica , Adulto , Procedimentos Cirúrgicos Cardíacos/mortalidade , Causas de Morte/tendências , Bases de Dados Factuais , Feminino , Valvas Cardíacas/cirurgia , Humanos , Masculino , Morbidade/tendências , Estudos Retrospectivos , Fatores de Risco , Cirurgiões , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
17.
Cardiovasc Revasc Med ; 40S: 196-199, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34059465

RESUMO

Treatment of recurrent MR after initially successful MitraClip procedure can pose therapeutic challenges. We report a successful case of redo MitraClip to treat recurrent inter-clip MR due to progression of underlying degenerative valvular pathology with prolapsing posterior mitral leaflet between the two prior clips. In this vignette, we describe the novel use of quantitative coronary arteriography (QCA) to select redo MitraClip as the treatment strategy.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Instrumentos Cirúrgicos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA