Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Ultrasound ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918318

RESUMO

Cerebral ultrasound is a non-invasive imaging technique widely used for the assessment of brain anatomy and diseases in neonates and infants. Indeed, it allows a precise characterization of common variants such as cavum septum pellucidum or diseases like intraventricular hemorrhage. The aim of this pictorial review is to provide a comprehensive overview of the main ultrasound features of the most common cerebral anatomical variants and disorders detectable by cerebral ultrasound using an age-related approach which could support non-subspecialized radiologists.

2.
Quant Imaging Med Surg ; 12(2): 1450-1466, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35111638

RESUMO

BACKGROUND: The primary objective of this study was to compare measurements of skeletal muscle index (SMI), visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) at the level of L3, on subjects who underwent computed tomography (CT) and magnetic resonance imaging (MRI) examinations within a three-month period. The secondary objective was to compare the automatic and semi-automatic quantifications of the same values for CT images. METHODS: Among subjects who underwent CT and MRI at our Institution between 2011 and 2020, exclusion criteria were: presence of extensive artifacts; images not including the whole waist circumference; CT acquired with low-dose technique and lack of non-contrast images. A set of three axial images (CT, MRI T1-weighted and T2-weighted) were used to extract the following measurements with semi-automatic segmentations: SMI [calculated normalizing skeletal muscle area (SMA) by the square height], SAT, VAT. For the CT images only, the same values were also calculated by using automatic segmentation. Statistical analysis was performed comparing quantitative MRI and CT measurements by Pearson correlation analysis and by Bland-Altman agreement analysis. RESULTS: A total of 123 patients were included. By performing linear regression analysis, CT and MRI measurements of SMI showed a high correlation (r2=0.81 for T1, r2=0.89 for T2), with a mean logarithmic difference between CT and MRI quantitative values of 0.041 for T1-weighted and 0.072 for T2-weighted images. CT and MRI measurements of SAT showed high correlation (r2=0.81 for T1; r2=0.81 for T2), with a mean logarithmic difference between CT and MRI values of 0.0174 for T1-weighted and 0.201 for T2-weighted images. CT and MRI measurements of VAT showed high correlation (r2=0.94 for T1; r2=0.93 for T2), with a mean logarithmic difference of 0.040 for T1-weighted and -0.084 for T2-weighted images. The comparison of values extracted by semi-automatic and automatic segmentations were highly correlated. CONCLUSIONS: Quantification of body composition values at MRI from T1-weighted and T2-weighted images was highly correlated to same values at CT, therefore quantitative values of body composition among patients who underwent either one of the examinations may be compared. CT body composition values extracted by semi-automatic and automatic segmentations showed high correlation.

3.
Pediatr Nephrol ; 37(4): 833-841, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34546419

RESUMO

BACKGROUND: Kidney diseases are a recognized cause of posterior reversible leukoencephalopathy syndrome, usually abbreviated as PRES. The purpose of this review was to systematically address the association between acute postinfectious glomerulonephritis and PRES. METHODS: We performed a systematic review of the literature on acute postinfectious glomerulonephritis associated with PRES. The principles recommended by the Economic and Social Research Council guidance on the conduct of narrative synthesis and on the Preferred Reporting Items for Systematic Reviews and Meta-analyses were used. Databases searched included Excerpta Medica, US National Library of Medicine, and Web of Science. RESULTS: For the final analysis, we evaluated 47 reports describing 52 cases (32 males and 20 females). Fifty patients were ≤ 18 years of age. Blood pressure was classified as follows: normal-elevated (n = 3), stage 1 hypertension (n = 3), stage 2 hypertension (n = 5), and severe hypertension (n = 41). Acute kidney injury was classified as stage 1 in 32, stage 2 in 16, and stage 3 in four cases. Neuroimaging studies disclosed a classic posterior PRES pattern in 28 cases, a diffuse PRES pattern in 23 cases, and a brainstem-cerebellum PRES pattern in the remaining case. Antihypertensive drugs were prescribed in all cases and antiepileptic drugs in cases presenting with seizures. A resolution of clinical findings and neuroimaging lesions was documented in all cases with information about follow-up. CONCLUSIONS: The main factor associated with PRES in acute postinfectious glomerulonephritis is severe hypertension. Prompt clinical suspicion, rapid evaluation, and management of hypertension are crucial. A higher resolution version of the Graphical abstract is available as Supplementary information.


Assuntos
Glomerulonefrite , Hipertensão , Síndrome da Leucoencefalopatia Posterior , Anti-Hipertensivos/uso terapêutico , Feminino , Glomerulonefrite/complicações , Glomerulonefrite/tratamento farmacológico , Humanos , Hipertensão/tratamento farmacológico , Imageamento por Ressonância Magnética , Masculino , Neuroimagem , Síndrome da Leucoencefalopatia Posterior/etiologia
4.
Cerebrovasc Dis ; 48(3-6): 140-148, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31661690

RESUMO

BACKGROUND: Carotid plaque neovascularization (vasa vasorum [VV]) may be useful for detecting high-risk atherosclerotic plaques. Contrast-enhanced ultrasound (CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) are 2 commonly used techniques for imaging VV of the carotid plaque, yet the relationship between their measurements remains unknown. OBJECTIVES: We aimed to blindly evaluate the correlation between CEUS and DCE-MRI in measuring carotid plaque VV. METHODS: We recruited subjects with asymptomatic carotid stenosis (≥50%). VV was graded by CEUS, based on richness of contrast signal, according to 3 different methods named CEUS_A, CEUS_B and CEUS_C on different point scales (the higher the values, the higher the estimated VV). A 3.0 T MRI scanner was used for VV quantification by DCE-MRI using gadolinium contrast kinetic modelling for computing the fractional plasma volume (vp) and transfer constant (Ktrans). RESULTS: The analysis included 30 patients. A significant correlation between CEUS and DCE-MRI findings was observed when CEUS_C was used for neovessel grading and DCE-MRI was used to determine adventitial (r = 0.460, p = 0.010) and plaque (r = 0.374, p = 0.042) Ktrans values. CEUS_B (r = 0.416, p = 0.022) and CEUS_C (r = 0.443, p = 0.014) grading showed a significant correlation with regard to the maximal Ktrans. CONCLUSIONS: We found a positive but weak correlation and a moderate diagnostic agreement between neovessels as visually graded by CEUS and adventitial neovessels assessed by DCE-MRI Ktrans in carotid atherosclerosis. These findings may help in understanding how VV density, flow, and permeability influence in vivo measurements by CEUS and DCE-MRI as well as in selecting the most appropriate variables and imaging method in future research and potentially in clinical settings. Further confirmative studies are necessary to confirm our results.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Angiografia por Ressonância Magnética , Meglumina/administração & dosagem , Neovascularização Patológica , Compostos Organometálicos/administração & dosagem , Fosfolipídeos/administração & dosagem , Placa Aterosclerótica , Hexafluoreto de Enxofre/administração & dosagem , Ultrassonografia Doppler Dupla , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , Artérias Carótidas/patologia , Estenose das Carótidas/patologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes
5.
Angiology ; 70(1): 20-34, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29783854

RESUMO

In the past decades, peripheral arteries have represented a model for the comprehension of atherosclerosis as well as for the development of new diagnostic imaging modalities and therapeutic strategies. Peripheral arteries may represent a window to study atherosclerosis. Pathology has prominently contributed to move the clinical and research attention from the arterial lumen stenosis and angiography to morphological and functional imaging techniques. Evidence from large and prospective cohort or randomized controlled studies is still modest. Nevertheless, several emerging imaging investigations represent a potential tool for a comprehensive "in vivo" evaluation of the entire natural history of peripheral atherosclerosis. This constitutes a demanding assignment, as it would be desirable to obtain both single-lesion focused and extensive arterial system views to achieve the most accurate prognostic information. Our narrative review rests upon the fundamental pathological evidence, summarizing the rapidly growing field of imaging of atherosclerosis in peripheral arteries and presenting a selection of both currently available and emerging imaging techniques.


Assuntos
Aterosclerose/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Aterosclerose/patologia , Humanos , Doença Arterial Periférica/patologia
6.
J Endovasc Ther ; 24(6): 852-858, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28891376

RESUMO

PURPOSE: To prospectively evaluate the long-term outcomes after a telementoring program for distant teaching of endovascular aneurysm repair (EVAR) and the degree of EVAR procedure assimilation into routine practice. METHODS: A telementoring protocol using stepwise introduction of EVAR was implemented between a university care center and a remote vascular health care site; from March 1999 to October 2003, 49 EVAR patients (mean age 72 years; 48 men) were treated during telementoring at the remote center. After the telementoring period, 86 patients (mean age 71 years; 77 men) underwent EVAR procedures carried out at the secondary care center from November 2003 to July 2011. The long-term outcomes were compared between the EVAR procedures performed during telementoring with the procedures performed independently thereafter. RESULTS: No significant difference was appreciated between telementored and not telementored procedures either in 30-day mortality (4.1% vs 2.3%, p=0.621) or in the initial technical success (93.9% vs 97.7%, p=0.353). The telementored group showed no significant difference in overall aneurysm-related mortality (6.1% vs 2.3%, p=0.353) or in the overall complication rates (p=0.985). The reintervention rate was significantly lower among the unmentored procedures (11.6% vs 32.7%, p=0.004). In particular, significantly fewer patients underwent late endovascular procedures (1.2% vs 12.2%, p=0.009) and late percutaneous interventions (7.0% vs 20.4%, p=0.027) after telementoring ceased. CONCLUSION: The telementoring program followed here allowed excellent EVAR skill assimilation into the routine practice of a remote health care site. Telementoring is a feasible strategy to support skill introduction in remote medical facilities.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/educação , Instrução por Computador/métodos , Educação a Distância/métodos , Procedimentos Endovasculares/educação , Mentores , Telemedicina/métodos , Idoso , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Competência Clínica , Angiografia por Tomografia Computadorizada , Currículo , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Eur Radiol Exp ; 1(1): 18, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29708194

RESUMO

BACKGROUND: The aim of this work was to evaluate detection of low-contrast objects and image quality in computed tomography (CT) phantom images acquired at different tube loadings (i.e. mAs) and reconstructed with different algorithms, in order to find appropriate settings to reduce the dose to the patient without any image detriment. METHODS: Images of supraslice low-contrast objects of a CT phantom were acquired using different mAs values. Images were reconstructed using filtered back projection (FBP), hybrid and iterative model-based methods. Image quality parameters were evaluated in terms of modulation transfer function; noise, and uniformity using two software resources. For the definition of low-contrast detectability, studies based on both human (i.e. four-alternative forced-choice test) and model observers were performed across the various images. RESULTS: Compared to FBP, image quality parameters were improved by using iterative reconstruction (IR) algorithms. In particular, IR model-based methods provided a 60% noise reduction and a 70% dose reduction, preserving image quality and low-contrast detectability for human radiological evaluation. According to the model observer, the diameters of the minimum detectable detail were around 2 mm (up to 100 mAs). Below 100 mAs, the model observer was unable to provide a result. CONCLUSION: IR methods improve CT protocol quality, providing a potential dose reduction while maintaining a good image detectability. Model observer can in principle be useful to assist human performance in CT low-contrast detection tasks and in dose optimisation.

8.
Data Brief ; 9: 563-567, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27752526

RESUMO

Here we provide the correlation among different carotid ultrasound (US) variables to assess echogenicity n standard carotid US and to assess intraplaque neovascularization on contrast enhanced US. We recruited 45 consecutive subjects with an asymptomatic≥50% carotid artery stenosis. Carotid plaque echogenicity at standard US was visually graded according to Gray-Weale classification (GW) and measured by the greyscale median (GSM), a semi-automated computerized measurement performed by Adobe Photoshop®. On CEUS imaging IPNV was graded according to the visual appearance of contrast within the plaque according to three different methods: CEUS_A (1=absent; 2=present); CEUS_B a three-point scale (increasing IPNV from 1 to 3); CEUS_C a four-point scale (increasing IPNV from 0 to 3). We have also implemented a new simple quantification method derived from region of interest (ROI) signal intensity ratio as assessed by QLAB software. Further information is available in "Contrast-enhanced ultrasound imaging of intraplaque neovascularization and its correlation to plaque echogenicity in human carotid arteries atherosclerosis (M. Cattaneo, D. Staub, A.P. Porretta, J.M. Gallino, P. Santini, C. Limoni et al., 2016) [1].

9.
Int J Cardiol ; 223: 917-922, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27597156

RESUMO

BACKGROUND: Currently the most widely accepted predictor of stroke risk in patients with carotid atherosclerosis is the degree of stenoses. Plaque echogenicity on ultrasound imaging (US) and intraplaque neovascularization (IPNV) are becoming recognized as factors of plaque vulnerability. Aim of the study was to investigate the correlation between the echogenicity of the carotid atherosclerosis by standard US and the degree of IPNV by contrast enhanced US (CEUS). METHODS: We recruited 45 consecutive subjects with an asymptomatic ≥50% carotid artery stenoses. Carotid plaque echogenicity at standard US was visually graded according to Gray-Weale classification (GW) and measured by the grayscale median (GSM), a semi-automated measurement performed by Adobe Photoshop©. On CEUS imaging IPNV was graded by different point scales according to the visual appearance of contrast within the plaque as follows: CEUS_A (1=absent; 2=present); CEUS_B (increasing IPNV from 1 to 3); and CEUS_C (increasing IPNV from 0 to 3). RESULTS: The correlation between echogenicity by GW and IPNV grading was as follows: CEUS_B (-0.130 p .423), CEUS_C (-0.108, p .509), CEUS_A (0.021, p .897). The correlation between echogenicity by GSM measurement and IPNV was as follows: using a CEUS_A (-0.125, p .444), CEUS_C (-0.021, p .897) (0.005, p .977). No correlation was found statistically significant. CONCLUSION: Our results display that there is no significant correlation between plaque echogenicity and IPNV. The small sample number and the multifaceted pathophysiology of the atherosclerotic plaque may explain the absence of statistically significantly correlation. Curtailing vulnerability explanation to either IPNV or echolucency may be misleading.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas , Neovascularização Patológica/diagnóstico , Placa Aterosclerótica/diagnóstico por imagem , Acidente Vascular Cerebral , Ultrassonografia/métodos , Idoso , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estatística como Assunto , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
10.
Vasa ; 45(6): 471-477, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27598044

RESUMO

BACKGROUND: Qualitative change in carotid plaques was prospectively evaluated by Gray Scale Median (GSM) analysis at repeated examinations "in vivo", in relation to quantitative change in carotid arterial geometry, as assessed by high-resolution magnetic resonance imaging (HR-MRI). PATIENTS AND METHODS: Duplex ultrasound with GSM analysis and HR-MRI at the carotid level were performed at baseline and 1- and 2-year follow up in 30 patients with < 70% carotid stenosis. Changes in GSM values (ΔGSM) were evaluated as the intra-individual difference between 2-year and baseline values. HR-MRI studies were evaluated for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA-LA) and normalized wall index (NWI = VWA/TVA). RESULTS: ΔGSM value distribution was divided into quartiles. Predominantly echolucent plaques with ΔGSM value in the lowest quartile (ΔGSM ≤- 8) showed a significantly greater mean 2-year LA (28.62 ± 10.9 mm2 vs. 17.88 ± 4.8 mm2, p = 0.04) and a greater mean 2-year TVA (83.64 ± 19.4 mm2 vs. 63.26 ± 9.2 mm2, p = 0.02) than predominantly echogenic plaques with ΔGSM value in the highest quartile (ΔGSM ≥8). CONCLUSIONS: Increasing echolucency during the 2-year follow up was associated with a 2-year lower degree of stenosis and higher tendency toward lumen preservation. By corroborating that plaque vulnerability is highly independent of stenosis severity, our study provided a possible new combined "in vivo" noninvasive approach for the assessment of carotid plaque vulnerability.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Multimodal/métodos , Placa Aterosclerótica , Ultrassonografia Doppler Dupla , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Ruptura Espontânea , Índice de Gravidade de Doença , Fatores de Tempo
11.
Int J Cardiovasc Imaging ; 31(8): 1611-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26296806

RESUMO

The purpose of this study was to evaluate differences of plaque composition and morphology within the same patient in different vascular beds using non-invasive MR-plaque imaging. 28 patients (67.8 ± 7.4 years, 8 females) with high Framingham general cardiovascular disease 10-year risk score and mild-to-moderate atherosclerosis were consecutively included in the study. All subjects underwent a dedicated MRI-plaque imaging protocol using TOF and T1w and T2w black-blood-sequences with fat suppression at 1.5 T. The scan was centered on the carotid bulb of the carotid arteries and on the most stenotic lesion of the ipsilateral femoral artery, respectively. Plaques were classified according to the American Heart Association (AHA) lesion type classification and area measurements of lumen, wall and the major plaque components, such as calcification, necrotic core and hemorrhage were determined in consensus by two blinded reviewers using dedicated software (Cascade, Seattle, USA). Plaque components were recorded as maximum percentages of the wall area. Carotid arteries had larger maximum wall and smaller minimum lumen areas (p < 0.001) than femoral arteries, whereas no significant difference was find with respect to the max. NWI (p = 0.87). Prevalence of lipid-rich AHA lesion type IV/V and complicated AHA lesion type VI with hemorrhage/thrombus/fibrous cap rupture was significantly higher in the carotid arteries compared to the femoral arteries. Plaque composition as percentage of the vessel wall differed significantly between carotid and femoral arteries: Max. %necrotic core and max. %hemorrhage were significantly higher in the carotid arteries compared to the femoral arteries (p = 0.001 and p = 0.02, respectively). Max. %calcification did not differ significantly. Average stenotic degree of carotid arteries at duplex was 49.7 ± 12.5 (%). Non-invasive MR plaque-imaging is able to visualize differences in plaque composition across the vascular tree. We observed significant differences in quantitative and qualitative plaque features between carotid and femoral arteries within the same patient, which in the future could help to improve risk stratification in patients with atherosclerosis.


Assuntos
Aterosclerose/patologia , Artérias Carótidas/patologia , Doenças das Artérias Carótidas/patologia , Artéria Femoral/patologia , Angiografia por Ressonância Magnética , Placa Aterosclerótica , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Constrição Patológica , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Necrose , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Software , Ultrassonografia Doppler Dupla
12.
J Comput Assist Tomogr ; 39(3): 365-72, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25700227

RESUMO

OBJECTIVES: To prospectively verify, in vivo, Le Bihan's model of signal decay in magnetic resonance/diffusion-weighted imaging (intravoxel incoherent motion) in healthy liver parenchyma. METHODS: Informed consent and institutional board approval were obtained. To measure both underfasting and postprandial conditions, apparent, slow, and fast diffusion (D*) coefficients and perfusion fraction of liver parenchyma, 40 healthy volunteers (19 women and 21 men) underwent a 3.0-T magnetic resonance imaging examination, including portal venous flow measurements by a 2-dimensional phase-contrast sequence, and multi-b diffusion-weighted imaging acquired before and 30 minutes after a 600-Kcal meal. Parameters were measured by fitting procedure with regions of interest drawn on the right liver lobe. Paired-sample t test was performed to search for any statistically significant difference between preprandial and postprandial values of each parameter and of portal flow. Pearson correlation coefficients were calculated to evaluate the relationship between portal flow increase and diffusion-weighted imaging parameter changes in postprandial conditions. Interobserver agreement for measurement of the intravoxel incoherent motion parameters was determined, both for preprandial and postprandial values. RESULTS: Mean increase in postprandial portal flow was 98% (P < 0.0009). The t test did not show any statistically significant difference between the preprandial and postprandial values for apparent, slow diffusion coefficients and perfusion fraction (P ≥ 0.05), whereas a statistically significant postprandial increase (P < 0.01) of D* was detected. Correlation with portal venous flow increase at Pearson test was statistically significant for D* (P = 0.04) and nonsignificant for the other parameters. All the parameters showed wide variability, with a higher percent coefficient of variation for D*. Interobserver agreement was always greater than 0.70. CONCLUSIONS: This study verifies Le Bihan's theory, confirming that in the liver, D* is influenced by perfusional changes related to portal venous flow.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Veias Hepáticas/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Circulação Hepática/fisiologia , Fígado/fisiologia , Angiografia por Ressonância Magnética/métodos , Adulto , Feminino , Veias Hepáticas/anatomia & histologia , Humanos , Imageamento Tridimensional/métodos , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Adulto Jovem
13.
J Endovasc Ther ; 20(5): 663-71, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24093319

RESUMO

PURPOSE: To report our results of endovascular aneurysm repair (EVAR) over a 10-year period using systematic preoperative collateral artery embolization. METHODS: From 1999 until 2009, 124 patients (117 men; mean age 70.8 years) with abdominal aortic aneurysm (AAA) underwent embolization of patent lumbar and/or inferior mesenteric arteries prior to elective EVAR procedures. Embolization was systematically attempted and, whenever possible, performed using microcoils and a coaxial technique. Follow-up included computed tomography and/or magnetic resonance imaging and abdominal radiography. RESULTS: The technical success for EVAR was 96% (119/124), with 4 patients dying within 30 days (3.2% perioperative mortality) and 1 type III endoleak accounting for the failures. Collateral arteries were occluded spontaneously or by embolization in 60 (48%) of 124 patients. The endoleak rate was 50.9% (74 in 61 patients), most of which were type II (19%). Over a mean clinical follow-up of 60.5±34.1 months (range 1-144), aneurysm sac dimensions decreased in 66 patients, increased in 19 patients, and were stable in 35. The endoleak rate was significantly higher in the patients with increasing sac diameter (p<0.001). Among the patients with patent collateral arteries, 38/64 (59.3%) developed 46 leaks, while 28 leaks appeared in 23 (41%) of 56 patients with collateral artery occlusion (p=0.069). The type II endoleak rate significantly differed between these two groups (47.8% vs. 3.6%, p<0.001). CONCLUSION: Preoperative collateral embolization seems to be a valid method of reducing the incidence of type II endoleak, improving the long-term outcome.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Circulação Colateral , Embolização Terapêutica , Endoleak/prevenção & controle , Procedimentos Endovasculares , Vértebras Lombares/irrigação sanguínea , Artéria Mesentérica Inferior/fisiopatologia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Eletivos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
14.
Eur Radiol ; 22(6): 1295-302, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22215074

RESUMO

OBJECTIVE: To determine the prevalence and importance of extracardiac findings (ECF) in patients undergoing clinical CMR and to test the hypothesis that the original CMR reading focusing on the heart may underestimate extracardiac abnormalities. METHODS: 401 consecutive patients (mean age 53 years) underwent CMR at 1.5 T. Main indications were ischaemic heart disease (n = 183) and cardiomyopathy (n = 164). All CMR sequences, including scout images, were reviewed with specific attention to ECF in a second reading by the same radiologist who performed the first clinical reading. Potentially significant findings were defined as abnormalities requiring additional clinical or radiological follow-up. RESULTS: 250 incidental ECF were detected, of which 84 (34%) had potentially significant ECF including bronchial carcinoma (n = 1), lung consolidation (n = 7) and abdominal abnormalities. In 166 CMR studies (41%) non-significant ECF were detected. The number of ECF identified at second versus first reading was higher for significant (84 vs. 47) and non-significant (166 vs. 36) findings (P < 0.00001). CONCLUSIONS: About one fifth of patients undergoing CMR were found to have potentially significant ECF requiring additional work-up. The second dedicated reading detected significantly more ECF compared with the first clinical reading emphasising the importance of active search for extracardiac abnormalities when evaluating CMR studies. KEY POINTS: • Many patients undergoing cardiac MR have significant extracardiac findings (ECF) • These impact on management and require additional work-up. • Wide review of scout and cine sequences will detect most ECFs. • Education of radiologists is important to identify ECFs on CMR studies.


Assuntos
Neoplasias Brônquicas/diagnóstico por imagem , Neoplasias Brônquicas/epidemiologia , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Doenças Torácicas/diagnóstico por imagem , Doenças Torácicas/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Humanos , Incidência , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Sensibilidade e Especificidade , Suíça/epidemiologia , Adulto Jovem
15.
Eur Heart J ; 33(2): 230-7, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21920966

RESUMO

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.


Assuntos
Aterosclerose/patologia , Artéria Carótida Primitiva/patologia , Artéria Carótida Interna/patologia , Estenose das Carótidas/patologia , Artéria Femoral/patologia , Idoso , Progressão da Doença , Feminino , Seguimentos , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Placa Aterosclerótica/patologia , Estudos Prospectivos
16.
AJR Am J Roentgenol ; 197(5): W852-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22021532

RESUMO

OBJECTIVE: The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA. MATERIALS AND METHODS: Normal-dose pulmonary CTA examinations using 120 kVp and 100 mL of contrast material in 10 patients with no PE were retrospectively selected. The image characteristics of an 80-kVp low-dose pulmonary CTA protocol (patient exposure reduction, 57%) with 75 mL of contrast material were simulated. Four different sets of filling defects were computer simulated in identical locations in each normal-dose and corresponding low-dose examination, equaling 783 PE in 40 normal-dose and 40 low-dose datasets. Ten normal-dose and 10 low-dose examinations contained no emboli and were used as controls. The 100 pulmonary CTA studies were randomly assessed by three readers blinded to PE location and image quality. The results were assessed by nonparametric tests and Student t tests. RESULTS: No difference was found between the CT protocols in terms of sensitivity, specificity, and positive and negative diagnostic likelihood ratios at all ramification levels of the pulmonary arteries (p = 0.343-1). The overall sensitivity and specificity with the normal and simulated low-dose protocols were 79.9% versus 81.3% and 98.0% versus 98.2% (p = 0.444 and 0.702), respectively. The diagnostic confidence (2.81 ± 0.39 vs 2.77 ± 0.47; p = 0.297) and overall image quality (3.92 ± 0.52 vs 3.83 ± 0.54; p = 0.216) were similar at 120 kV and 80 kV. CONCLUSION: The intraindividual comparison of diagnostic accuracy with normal-dose and simulated low-dose pulmonary CTA protocols revealed no difference under experimental conditions.


Assuntos
Angiografia/métodos , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Simulação por Computador , Meios de Contraste/administração & dosagem , Feminino , Humanos , Masculino , Doses de Radiação , Estudos Retrospectivos , Sensibilidade e Especificidade , Estatísticas não Paramétricas
18.
Ann Thorac Surg ; 90(5): 1507-13, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20971250

RESUMO

BACKGROUND: The PAS-Port system (Cardica, Inc, Redwood City, CA) was used routinely for patients undergoing coronary surgery with at least one venous graft. Graft patency and clinical results were evaluated, respectively, at 6 months and 5 years after surgery. METHODS: A total of 100 patients (82 males, 18 females; mean age 68.9 ± 12 years) underwent coronary bypass surgery with at least one PAS-Port anastomosis (total number of PAS-Port implants: n = 117). At 6 months after surgery all patients were followed up clinically and 86 patients with 101 PAS-Port implants underwent either a multidetector computed tomographic scan or coronary angiography. Actuarial freedom from MACCE (major adverse cardiac and cerebrovascular events) was assessed at 5 years after surgery. RESULTS: Six-month PAS-Port patency was 88%. The inner diameter of the graft at the implant site (measured in 26 patients) did not reveal any pathologic narrowing (mean inner diameter 3.1 ± 0.6 mm). At 5 years, freedom from overall MACCE was 79% ± 5% and freedom from PAS-Port target vessel revascularization was 94% ± 6%. CONCLUSIONS: The routine use of PAS-Port was associated with good vein graft patency at 6 months and a low incidence of MACCE at 5 years after surgery. No evidence of implant-related graft stenosis was detected.


Assuntos
Anastomose Cirúrgica/métodos , Ponte de Artéria Coronária/efeitos adversos , Grau de Desobstrução Vascular , Adulto , Idoso , Ponte de Artéria Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
20.
Radiother Oncol ; 92(1): 118-24, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19181409

RESUMO

PURPOSE: A treatment planning study was performed to compare volumetric-modulated arc radiotherapy against conventional fixed field IMRT. MATERIALS AND METHODS: CT datasets of 10 patients affected by carcinoma of the anal canal were included and five plans were generated for each case: fixed beam IMRT, single (RA1)- and double (RA2)-modulated arcs with the RapidArc technique. Dose prescription was set according to a simultaneous integrated boost strategy to 59.4 Gy to the primary tumour PTVI (at 1.8 Gy/fraction) and to 49.5 Gy to risk area including inguinal nodes, PTVII. Planning objectives for PTV were minimum dose >95%, maximum dose<107%; for organs at risk (OARs): bladder (mean<45 Gy, D(2%)<56 Gy, D(30%)<35 Gy), femurs (D(2%)<47 Gy), small bowel (mean<30 Gy, D(2%)<56 Gy). MU and delivery time scored treatment efficiency. RESULTS: All techniques fulfilled objectives on maximum dose. Some deviations were observed on minimum dose for PTV. Uniformity (D(5)-D(95)) on PTVI resulted 6.6+/-1.4% for IMRT and ranged from 5.7+/-0.3% to 8.1+/-0.8% for RA plans (+/-1 standard deviation). Conformity index (CI(95%)) was 1.3+/-0.1 (IMRT) and 1.4+/-0.1 (all RA techniques). Bladder: all techniques resulted equivalent above 40 Gy; V(30 Gy) approximately 57% for the double arcs, approximately 61% for RA1 and approximately 65% for IMRT. Femurs: maximum dose was of the order of 41-42 Gy for all RA plans and approximately 45 Gy for IMRT. Small bowel: all techniques respected planning objectives. The number of computed MU/fraction was 1531+/-206 (IMRT), 468+/-95 (RA1), and 545+/-80 (RA2) leading to differences in treatment time: 9.4+/-1.7 min for IMRT vs. 1.1+/-0.0 min for RA1 and 2.6+/-0.0 min for double arcs. CONCLUSION: RapidArc showed improvements in organs at risk and healthy tissue sparing with uncompromised target coverage when double arcs are applied. Optimal results were also achieved anyway with IMRT plans.


Assuntos
Canal Anal/efeitos da radiação , Neoplasias do Ânus/radioterapia , Carcinoma de Células Escamosas/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada , Feminino , Humanos , Masculino , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA