Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Front Oncol ; 13: 1259851, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023210

RESUMO

Purpose: This study aimed to evaluate the robustness with respect to the positional variations of five planning strategies in free-breathing breast hypofractionated radiotherapy (HFRT) for patients after breast-conserving surgery. Methods: Twenty patients who received breast HFRT with 42.72 Gy in 16 fractions were retrospectively analyzed. Five treatment planning strategies were utilized for each patient, including 1) intensity-modulated radiation therapy (IMRT) planning (IMRTpure); 2) IMRT planning with skin flash tool extending and filling the fluence outside the skin by 2 cm (IMRTflash); 3) IMRT planning with planning target volume (PTV) extended outside the skin by 2 cm in the computed tomography dataset (IMRTePTV); 4) hybrid planning, i.e., 2 Gy/fraction three-dimensional conformal radiation therapy combined with 0.67 Gy/fraction IMRT (IMRThybrid); and 5) hybrid planning with skin flash (IMRThybrid-flash). All plans were normalized to 95% PTV receiving 100% of the prescription dose. Six additional plans were created with different isocenter shifts for each plan, which were 1 mm, 2 mm, 3 mm, 5 mm, 7 mm, and 10 mm distally in the X (left-right) and Y (anterior-posterior) directions, namely, (X,Y), to assess their robustness, and the corresponding doses were recalculated. Variation of dosimetric parameters with increasing isocenter shift was evaluated. Results: All plans were clinically acceptable. In terms of robustness to isocenter shifts, the five planning strategies followed the pattern IMRTePTV, IMRThybrid-flash, IMRTflash, IMRThybrid, and IMRTpure in descending order. V 95% of IMRTePTV maintained at 99.6% ± 0.3% with a (5,5) shift, which further reduced to 98.2% ± 2.0% with a (10,10) shift. IMRThybrid-flash yielded the robustness second to IMRTePTV with less risk from dose hotspots, and the corresponding V 95% maintained >95% up until (5,5). Conclusion: Considering the dosimetric distribution and robustness in breast radiotherapy, IMRTePTV performed best at maintaining high target coverage with increasing isocenter shift, while IMRThybrid-flash would be adequate with positional uncertainty<5 mm.

2.
Front Oncol ; 12: 820632, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35211411

RESUMO

PURPOSE: This study aimed to investigate the dosimetric effect and delivery reliability of jaw tracking (JT) with increasing planning target volume (PTV) for lung stereotactic body radiation therapy (SBRT) plans. A threshold of PTV was proposed as a selection criterion between JT and fixed-jaw (FJ) techniques. METHODS: A total of 28 patients with early-stage non-small-cell lung cancer were retrospectively included. The PTVs ranged from 4.88 cc to 68.74 cc, prescribed with 48 Gy in four fractions. Three-partial-arc volumetric modulated arc therapy (VMAT) plans with FJ and with JT were created for each patient with the same optimization objectives. These two sets of plans were compared using metrics, including conformity index (CI), V50%, R50%, D2cm, dose-volume parameters of organs at risk, and monitor units (MUs). The ratio of small subfields (<3 cm in either dimension), %SS, was acquired as a surrogate for the small-field uncertainty. Statistical analyses were performed to evaluate the correlation between the differences in these parameters and the PTV. RESULTS: The V50%, R50%, D2cm, and V20Gy, D1,500cc, and D1,000cc of the lung showed a statistically significant improvement in JT plans as opposed to FJ plans, while the number of MU in JT plans was higher by an average of 1.9%. Between FJ and JT plans, the PTV was strongly correlated with the differences in V50%, moderately correlated with those in V20Gy of the lung, and weakly correlated with those in D2cm and D1,500cc of the lung. By using JT, %SS was found to be negatively correlated with the PTV, and the PTV should be at least approximately 12.5 cc for an expected %SS <50%, which was 15 cc for a %SS <20% and 20 cc for a %SS <5%. CONCLUSIONS: Considering the dosimetric differences and small-field uncertainties, JT could be selected using a PTV threshold, such as 12.5, 15, or 20 cc, on the basis of the demand of delivery reliability for lung SBRT.

3.
Sci Rep ; 11(1): 21879, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-34750457

RESUMO

Radiotherapy (RT) is one of the main treatment strategies of breast cancer. It is challenging to design RT plans that can completely cover the target area while protecting organs at risk (OAR). The Plan-IQ feasibility tool can estimate the best sparing dose of OAR before optimizing the Plan. A systematic quantitative evaluation of the quality change of intensity-modulated radiation therapy (IMRT) using the Plan-IQ feasibility tool was performed for modified radical mastectomy in this study. We selected 50 patients with breast cancer treated with IMRT. All patients received the same dose in the planning target volume (PTV). The plans are categorized into two groups, with each patient having one plan in each group: the clinically accepted normal plan group (NP group) and the repeat plan group (RP group). An automated planning strategy was generated using a Plan-IQ feasibility dose volume histogram (FDVH) in RP group. These plans were assessed according to the dosimetry parameters. A detailed scoring strategy was based on the RTOG9804 report and 2018 National Comprehensive Cancer Network guidelines, combined with clinical experience. PTV coverage in both groups was achieved at 100% of the prescribed dose. Except for the thyroid coverage, the dose limit of organs at risk (OAR) in RP group was significantly better than that in NP group. In the scoring analysis, the total scores of RP group decreased compared to that of NP group (P < 0.05), and the individual scores of PTV and OAR significantly changed. PTV scores in RP group decreased (P < 0.01); however, OAR scores improved (P < 0.01). The Plan-IQ FDVH was useful for evaluating a class solution for IMRT planning. Plan-IQ can automatically help physicians design the best OAR protection plan, which sacrifices part of PTV, but still meets clinical requirements.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Mastectomia Radical Modificada , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Terapia Combinada/métodos , Terapia Combinada/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia Adjuvante/métodos , Radioterapia Adjuvante/estatística & dados numéricos , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Estudos Retrospectivos , Software
4.
Sci Rep ; 11(1): 19035, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34561504

RESUMO

To optimize the collimator angles in dual-arc volumetric modulated arc therapy (VMAT) plans for whole-brain radiotherapy with hippocampus and inner ear sparing (HIS-WBRT). Two sets of dual-arc VMAT plans were generated for 13 small-cell lung cancer patients: (1) The collimator angles of arcs 1 and 2 (θ1/θ2) were 350°/10°, 350°/30°, 350°/45°, 350°/60°, and 350°/80°, i.e., the intersection angle of θ1 and θ2 (Δθ) increased. (2) θ1/θ2 were 280°/10°, 300°/30°, 315°/45°, 330°/60°, and 350°/80°, i.e., Δθ = 90°. The conformity index (CI), homogeneity index (HI), monitor units (MUs), and dosimetric parameters of organs-at-risk were analyzed. Quality assurance for Δθ = 90° plans was performed. With Δθ increasing towards 90°, a significant improvement was observed for most parameters. In 350°/80° plans compared with 350°/10° ones, CI and HI were improved by 1.1% and 25.2%, respectively; MUs were reduced by 16.2%; minimum, maximum, and mean doses (D100%, Dmax, and Dmean, respectively) to the hippocampus were reduced by 5.5%, 6.3%, and 5.4%, respectively; Dmean to the inner ear and eye were reduced by 0.7% and 5.1%, respectively. With Δθ kept at 90°, the plan quality was not significantly affected by θ1/θ2 combinations. The gamma-index passing rates in 280°/10° and 350°/80° plans were relatively lower compared with the other Δθ = 90° plans. Δθ showed a significant effect on dual-arc VMAT plans for HIS-WBRT. With Δθ approaching 90°, the plan quality exhibited a nearly continuous improvement, whereas with Δθ = 90°, the effect of θ1/θ2 combination was insignificant.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Orelha Interna , Hipocampo , Tratamentos com Preservação do Órgão/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Carcinoma de Pequenas Células do Pulmão/patologia , Resultado do Tratamento
5.
Sci Rep ; 10(1): 10927, 2020 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-32616839

RESUMO

To evaluate the quality of planning target volume (PTV) and organs at risk (OAR) generated by the manual Pinnacle planning (manP) and Auto-Planning (AP) modules and discuss the feasibility of AP in the application of radiotherapy for patients with breast cancer. Thirty patients who underwent breast-conserving therapy were randomly selected. The Philips Pinnacle 9.10 treatment planning system was used to design the manP and AP modules for PTV and OAR distribution on the same computed tomography. A physician compared the plans in terms of dosimetric parameters and monitor units (MUs) using blind qualitative scoring. Statistical differences were evaluated using paired two-sided Wilcoxon's signed-rank test. On comparing the plans of AP and manP modules, the conformal index (P < 0.01) and D50 (P = 0.04) of PTV in the AP group was lower than those in the manP group, while D1 was higher (P = 0.03). In terms of dosimetry of OAR, ipsilateral lung V20 Gy (P < 0.01), V10 Gy (P < 0.01), V5 Gy (P < 0.05), and Dmean (P < 0.01) of the AP group were better than those of the manP group. Heart V40 Gy and Dmean of all patients with breast cancer in the AP group were lower than those in the manP group (P < 0.01). Moreover, 12 patients with left breast cancer had the same results (P < 0.01). The MU value of the intensity-modulated radiation therapy module designed using two different methods was higher in the AP group than in the manP group (P = 0.32), although there was no statistical significance. The AP module almost had an equal quality of PTV and dose distribution as the manP module, and its OAR was less irradiated.


Assuntos
Neoplasias da Mama/radioterapia , Mastectomia Segmentar , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Adjuvante , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X , Adulto , Idoso , Automação , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Pessoa de Meia-Idade , Órgãos em Risco , Radiometria , Dosagem Radioterapêutica , Estudos de Amostragem
6.
Front Chem ; 8: 388, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32500057

RESUMO

The SiO-based composites containing different carbon structures were prepared from asphalt and graphite by the milling, spray drying, and pyrolysis. In the obtained near-spherical composite particles, the refined amorphous SiO plates, which are coated with an amorphous carbon layer, are aggregated with the binding of graphite sheets. The SiO/C/Graphite composites present a maximum initial charge capacity of 963 mAh g-1 at 100 mA g-1, excellent cyclic stability (~950 mAh g-1 over 100 cycles), and rate capability with the charge capacity of 670 mAh g-1 at 1,000 mA g-1. This significant improvement of electrochemical performances in comparison with pristine SiO or SiO/C composite is attributed to the unique microstructure, in which both the graphite sheets and amorphous carbon coating could enhance the conductivity of SiO and buffer the volume change of SiO. The higher pyrolysis temperature causes the denser spherical microstructure and better cycle life. Our work demonstrates the potential of this SiO/C/Graphite composite for high capacity anode of LIBs.

7.
Chem Commun (Camb) ; 46(19): 3357-9, 2010 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-20442900

RESUMO

A base-catalyzed tandem Michael addition/intramolecular isocyanide [3 + 2] cycloaddition of ethyl isocyanoacetate and Michael acceptors with tethered carbonyl groups is described. This reaction leads to the formation of fused oxazolines in a highly diastereoselective manner under very mild conditions.


Assuntos
Cianetos/síntese química , Oxazóis/síntese química , Cianetos/química , Ciclização , Estrutura Molecular , Oxazóis/química , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA