Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
BMC Pregnancy Childbirth ; 22(1): 417, 2022 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-35585573

RESUMO

BACKGROUND: Due to the extensive development of assisted reproductive technology, the number of twin pregnancies has increased significantly over recent decades. Twin pregnancy is the most representative type of multiple pregnancies and is associated with high infant morbidity and mortality. Perinatal complications of twin pregnancy are also markedly increased compared with those of single pregnancy. Transabdominal selective reduction (SR) is a remedial intervention. This study aimed to research the adverse outcomes of transabdominal selective reduction of twin pregnancy and the correlation between the reduction week and pregnancy outcomes. OBJECTIVE: The purpose of this study was to examine the adverse outcomes of the transabdominal selective reduction of twin pregnancy and the correlation between the reduction week and pregnancy outcomes. METHODS: A retrospective cohort study of the transabdominal reduction of twin pregnancy was conducted in a single prenatal diagnosis medical centre from September 2012 to October 2020. According to chorionicity, women with twin pregnancies were divided into 2 groups: dichorionic (DC) twin pregnancies and monochorionic (MC) twin pregnancies. Women with DC twin pregnancies underwent potassium chloride reduction, and those with MC twin pregnancies underwent radiofrequency ablation (RFA). The reduction indications included pregnancy complications, foetal abnormalities, and maternal factors. The perinatal outcomes of different chorionic twins after reduction were analysed. Each foetus with an adverse outcome was included. The relative relationship between the reduction weeks and delivery weeks of twins was examined by correlation analysis. RESULTS: A total of 161 women were included in this study. A total of 112 women had DC twin pregnancies, and 49 women had MC twin pregnancies. Preterm delivery rates were significantly higher in the MC twin reduction group than in the DC twin reduction group prior to 37 weeks (53.1% vs. 29.5%, P = 0.004). The mean gestational age at delivery of the foetuses in the DC twin group that underwent SR was significantly older than that of those in the MC twin group that underwent SR (36.9 ± 4.0 vs. 33.5 ± 6.6 weeks, P = 0.001). The number of DC twins that underwent SR and were delivered after 37 weeks was obviously greater than that of the MC twins that underwent SR (70.5% vs. 46.9%, P = 0.004). The foetal survival rate was 95.5% in the DC twin reduction group and 77.6% in the MC twin reduction group. If the indication of TTTS was not included, there was no significant difference in the foetal survival rate of the DC and MC twin reduction groups (95.5% vs. 86.2%, P = 0.160). Cotwin death 1 week after reduction was greater in the MC group (6.1% vs. 0%, P = 0.027). Compared to other indications, this finding indicated that a significantly lower proportion of women remained undelivered after selective reduction with the indication of TTTS. There was a significant negative correlation between the reduction weeks and delivery weeks of the two groups (P < 0.01), and the best opportunity for reduction was before 22 weeks of gestation. CONCLUSION: These findings highlighted an obviously negative correlation between the reduction week and delivery week. The transabdominal selective reduction of twin pregnancy should be considered for a lower rate of miscarriage or premature delivery if the reduction week takes place earlier in pregnancy. The rate of preterm delivery was the lowest when transabdominal selective reduction was completed before 22 weeks of gestation. Compared with other RFA indications, a higher rate of premature delivery was shown for MC twins with a reduction indication of TTTS. TTTS with sIUGR might be one of the reasons for the adverse outcomes of reduction for MC twin pregnancy.


Assuntos
Gravidez de Gêmeos , Nascimento Prematuro , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Gravidez , Resultado da Gravidez/epidemiologia , Nascimento Prematuro/epidemiologia , Nascimento Prematuro/etiologia , Estudos Retrospectivos , Gêmeos Dizigóticos , Gêmeos Monozigóticos
2.
Chin Med J (Engl) ; 134(15): 1819-1827, 2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34238852

RESUMO

BACKGROUND: Twin pregnancies continue to increase worldwide; however, the current clinical prenatal evaluation for the intrauterine growth of twins still relies on the growth standards of singletons. We attempted to establish a set of fetal biometric references for Chinese twin pregnancies, stratified by chorionicity and conception mode as spontaneously conceived monochorionic diamniotic (SC-MCDA), spontaneously conceived dichorionic diamniotic (SC-DCDA), and assisted reproductive technology dichorionic diamniotic (ART-DCDA) twins. METHODS: From 2016 to 2019, the ultrasonographic fetal biometric measurements were longitudinally collected in pregnant women, including fetal weight, biparietal diameter, head circumference, abdominal circumference, femur length, and humerus length. The linear mixed models were used to test the difference of growth patterns between groups, and the growth curve of each biometric parameter was modeled by a generalized additive model for location scale and shape. RESULTS: A total of 929 twin pregnant women and 2019 singleton pregnant women, met the inclusion criteria. Among twin pregnancies, 148 were SC-MCDA, 215 were SC-DCDA, and 566 were ART-DCDA twins. Overall, SC-DCDA twins grew faster than SC-MCDA twins, while slower than ART-DCDA twins (all P < 0.05), and all of the three groups showed significant differences comparing with singletons, especially during the third trimester. Hence, the customized fetal growth charts of each fetal biometric parameter were, respectively, constructed for SC-MCDA, SC-DCDA, and ART-DCDA twins. CONCLUSIONS: The fetal biometric trajectories demonstrated characteristic patterns according to chorionicity and conception mode. To fill the gap, we modeled fetal biometric parameters for Chinese SC-MCDA, SC-DCDA, and ART-DCDA twin pregnancies, hoping to provide a reference for the further establishment of fetal growth reference values for Chinese twin fetuses.


Assuntos
Desenvolvimento Fetal , Gráficos de Crescimento , China , Feminino , Humanos , Gravidez , Gravidez de Gêmeos , Estudos Retrospectivos , Ultrassonografia Pré-Natal
3.
Bioanalysis ; 9(2): 183-192, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27960545

RESUMO

AIM: It is challenging to develop a multiple reaction monitoring (MRM) method for some disulfide-bonded peptides with inefficient collision-induced dissociation fragmentation. This study describes a new methodology using differential mobility spectrometry (DMS) combined with multiple ion monitoring (MIM) to enhance bioanalytical sensitivity for sunflower trypsin inhibitor. RESULTS: By combining DMS with MIM to monitor the intact precursor ion in Q1 and Q3 MS analyzers, a lower limit of quantitation at 0.125 ng/ml was achieved to quantify sunflower trypsin inhibitor in rat plasma, representing a 40-fold sensitivity improvement over MIM without DMS. CONCLUSION: DMS coupled with MIM method provides triple quadrupole MS users an effective means to overcome challenges in analyzing disulfide-bonded peptides or other analytes that do not have useful collision-induced dissociation fragment ions for MRM analysis.


Assuntos
Técnicas de Química Analítica/métodos , Dissulfetos/química , Espectrometria de Massas , Peptídeos Cíclicos/sangue , Animais , Cromatografia Líquida de Alta Pressão , Íons/química , Limite de Detecção , Ratos
4.
Anal Chem ; 88(7): 3655-61, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-26937555

RESUMO

A differential mobility spectrometry (DMS) in combination with a multiple ion monitoring (MIM) method was developed and validated for quantitative LC-MS/MS bioanalysis of pasireotide (SOM230) in human plasma. Pasireotide, a therapeutic cyclic peptide, exhibits poor collision-induced dissociation (CID) efficiency for multiple reaction monitoring (MRM) detection. Therefore, in an effort to increase the overall sensitivity of the assay, a DMS-MIM approach was explored. By selecting the most abundant doubly charged precursor ion in both the Q1 and Q3 of the mass analyzer in MIM and combining the DMS capability to significantly reduce the high matrix/chemical background noise, this new LC-DMS-MIM method overcomes the sensitivity challenge in the typical MRM method due to poor CID fragmentation of the analyte. Human plasma was spiked with pasireotide with concentrations in the range 0.01-50 ng/mL. Weak cation-exchange solid-phase extraction was employed for sample preparation. The sample extracts were analyzed with a SCIEX QTRAP 6500 system equipped with an ESI source and DMS device. The separation voltage and compensation voltage of the DMS and other parameters of the MS system were optimized to maximize signal responses. The performance of the LC-DMS-MIM assay for quantitative analysis of pasireotide in human plasma was evaluated and compared to those obtained via LC-MRM and LC-MIM without DMS. Overall, the assay sensitivity with DMS-MIM was approximately 5-fold better than that observed in MRM or MIM without DMS. The assay was validated with accuracy (% bias) and precision (% CV) of the QC results at eight concentration levels (0.01, 0.02, 0.05, 0.15, 0.3, 1.5, 15, and 37.5 ng/mL) evaluated ranging from -4.8 to 5.0% bias and 0.7 to 8.6% CV for the intraday and interday runs. The current LC-DMS-MIM workflow can be expanded to quantitative analysis of other molecules that have poor fragmentation efficiency in CID.


Assuntos
Somatostatina/análogos & derivados , Humanos , Somatostatina/sangue , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-25464088

RESUMO

BMS-791325 is a hepatitis C virus (HCV) non-structural protein 5B (NS5B) RNA polymerase inhibitor that is being developed for the treatment of HCV infection. A rugged and accurate LC-MS/MS method was developed and validated for the quantitation of BMS-791325 and its metabolite, BMS-794712, in rat and dog plasma. This method utilized stable-isotope labeled [D6]-BMS-791325 and [13CD3]-BMS-794712 as internal standards. The samples were extracted using liquid-liquid extraction with n-butyl-chloride. Chromatographic separation was achieved with gradient elution on a Waters Atlantis dC18 analytical column (2.1mm×50mm, 3.0µm). Analytes and their stable isotope labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The standard curves, which ranged from 5.00 to 2000ng/mL for BMS-791325 and from 1.00 to 400ng/mL for BMS-794712, were fitted to a 1/x2 weighted linear regression model. For both species, the intra-assay precision was within ±4.3% CV, the inter-assay precision was within ±6.2% CV, and the assay accuracy was within ±10.8% of the nominal values for BMS-791325 and BMS-794712. The validated method was successfully applied to support pre-clinical toxicokinetic studies.

6.
Artigo em Inglês | MEDLINE | ID: mdl-25151331

RESUMO

A sensitive, accurate and rugged UHPLC-MS/MS method was developed and validated for the quantitation of Epothilone D (EpoD), a microtubule stabilizer in development for treatment of Alzeimer's disease, in rat plasma. The ester group in EpoD can be hydrolyzed by esterases in blood or plasma, which creates a stability concern for the bioanalysis of EpoD. Species differences in the stability of EpoD in plasma were observed. Carboxylesterases were identified as the likely esterases responsible for the hydrolysis of EpoD in plasma ex vivo, and the cause of the species different stability. Phenylmethanesulfonyl fluoride, a carboxylesterase inhibitor, was used to stabilize EpoD in rat blood during sample collection, processing, and storage. A systematic method screening and optimization strategy was used to improve the assay sensitivity and minimize potential bioanalytical risks. The stabilized plasma samples were extracted by liquid-liquid extraction. Chromatographic separation was achieved on an Acquity UPLC BEH Phenyl column with a gradient elution. EpoD and its stable isotope labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The standard curve, which ranged from 0.100 to 100ng/mL was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within ±3.6% CV and inter-assay precision was within ±4.2% CV. The assay accuracy was within ±8.3% of the nominal values. Assay recovery of EpoD was high (∼90%) and matrix effect was minimal (1.02-1.05). EpoD was stable in stabilized rat plasma for at least 30h at room temperature, 180 days at -20°C, and following three freeze-thaw cycles. The validated method was successfully applied to sample analysis in toxicology studies.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Epotilonas/sangue , Epotilonas/química , Fluoreto de Fenilmetilsulfonil/química , Espectrometria de Massas em Tandem/métodos , Animais , Hidrolases de Éster Carboxílico/antagonistas & inibidores , Hidrolases de Éster Carboxílico/efeitos dos fármacos , Estabilidade de Medicamentos , Epotilonas/farmacocinética , Feminino , Modelos Lineares , Fluoreto de Fenilmetilsulfonil/farmacologia , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
J Pharm Biomed Anal ; 83: 237-48, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23770636

RESUMO

BMS-927711 is a calcitonin gene-related peptide (CGRP) receptor antagonist that is being developed for the treatment of migraine. A rapid, accurate and robust assay was developed and validated for the quantitation of BMS-927711 in rat, monkey, rabbit and mouse plasma using ultra high performance liquid chromatography with tandem mass spectrometry (UHPLC-MS/MS). A simplified method screening strategy was utilized that included a liquid-liquid extraction (LLE) methodology and eleven LC columns (ten sub-2 µm UHPLC columns and one 2.6 µm HPLC column) for screening with emphasis on the removal of phospholipids, avoidance of metabolite interference and ruggedness of LC conditions. A stable isotope labeled [(13)C2, D4]-BMS-927711 was used as the internal standard, and 50 µL of plasma samples were used for extraction by automated LLE with methyl tert-butyl ether (MTBE) in 96-well format. Chromatographic separation was achieved with an isocratic elution and a gradient column wash on a Waters Acuity UPLC(®) BEH C18 column (2.1 mm × 50 mm, 1.7 µm) with run time of 3.7 min. Positive electrospray ionization was performed using selected reaction monitoring (SRM) with transitions of m/z 535>256 for BMS-927711 and m/z 541>256 for [(13)C2, D4]-BMS-927711. The standard curve, which ranged from 3.00 to 3000 ng/mL for BMS-927711, was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within 5.2% CV, inter-assay precision was within 5.9% CV, and the assay accuracy was within ±5.2% deviation (%Dev) of the nominal values in all the species. The stability of an N-carbamoyl glucuronide metabolite was carefully investigated, and the conversion of this metabolite to BMS-927711 was minimal and manageable without a stabilization procedure. The method was successfully applied to multiple non-clinical toxicokinetic studies in different species in support of the investigative new drug (IND) filing.


Assuntos
Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina , Cromatografia Líquida de Alta Pressão/métodos , Piperidinas/sangue , Piperidinas/química , Piridinas/sangue , Piridinas/química , Espectrometria de Massas em Tandem/métodos , Animais , Glucuronídeos/química , Haplorrinos , Extração Líquido-Líquido/métodos , Camundongos , Coelhos , Ratos , Padrões de Referência
8.
Artigo em Inglês | MEDLINE | ID: mdl-23435345

RESUMO

Asunaprevir (BMS-650032) is a potent hepatitis C virus (HCV) non-structural protein protease inhibitor currently in Phase III clinical trials for the treatment of HCV infection. A rugged and accurate LC-MS/MS method was developed and validated for the quantitation of asunaprevir in rat, dog, monkey, rabbit and mouse plasma. A systematic method screening and optimization strategy was applied to achieve optimized mass spectrometry, chromatography, and sample extraction conditions. The validated method utilized stable-isotope labeled D9-asunaprevir as the internal standard. The samples were extracted by liquid-liquid extraction using 10% ethyl acetate in hexane. Chromatographic separation was achieved with gradient elution on a Waters Atlantis dC18 analytical column. Analyte and its internal standard were detected by positive ion electrospray tandem mass spectrometry. The standard curve, which ranged from 5.00 to 2000ng/mL for asunaprevir, was fitted to a 1/x(2) weighted linear regression model. The intra-assay precision was within ±3.6% CV, inter-assay precision was within ±4.0% CV, and the assay accuracy was within ±8.1% of the nominal values in all the species. The method was successfully applied to support multiple pre-clinical toxicokinetic studies in different species.


Assuntos
Antivirais/sangue , Hepacivirus/enzimologia , Isoquinolinas/sangue , Inibidores de Proteases/sangue , Sulfonamidas/sangue , Espectrometria de Massas em Tandem/métodos , Proteínas não Estruturais Virais/antagonistas & inibidores , Animais , Cromatografia Líquida/métodos , Cães , Haplorrinos , Hepatite C/tratamento farmacológico , Camundongos , Coelhos , Ratos , Sensibilidade e Especificidade
9.
Drug Metab Dispos ; 40(12): 2374-80, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22983304

RESUMO

Brivanib alaninate is an orally administered alanine prodrug of brivanib, a dual inhibitor of the vascular endothelial growth factor (VEGF) and fibroblast growth factor (FGF) signaling pathways. It is currently in clinical trials for the treatment of hepatocellular carcinoma and colorectal cancer. Brivanib has a single asymmetric center derived from a secondary alcohol. The potential for chiral inversion was investigated in incubations with liver subcellular fractions and in animals and humans after oral doses of brivanib alaninate. Incubations of [¹4C]brivanib alaninate with liver microsomes and cytosols from rats, monkeys, and humans followed by chiral chromatography resulted in two radioactive peaks, corresponding to brivanib and its enantiomer. The percentage of the enantiomeric metabolite relative to brivanib in microsomal and cytosolic incubations of different species in the presence of NADPH ranged from 11.6 to 15.8 and 0.8 to 3.1%, respectively. The proposed mechanism of inversion involves the oxidation of brivanib to a ketone metabolite, which is subsequently reduced to brivanib and its enantiomer. After oral doses of brivanib alaninate to rats and monkeys, the enantiomeric metabolite was a prominent drug-related component in plasma, with the percentages of area under the curve (AUC) at 94.7 and 39.7%, respectively, relative to brivanib. In humans, the enantiomeric metabolite was a minor circulating component, with the AUC <3% of brivanib. Pharmacological studies indicated that brivanib and its enantiomer had similar potency toward the inhibition of VEGF receptor-2 and FGF receptor-1 kinases. Because of low plasma concentration in humans, the enantiomeric metabolite was not expected to contribute significantly to target-related pharmacology of brivanib. Moreover, adequate exposure in the toxicology species suggested no specific safety concerns with respect to exposure to the enantiomeric metabolite.


Assuntos
Alanina/análogos & derivados , Triazinas/farmacocinética , Administração Oral , Adolescente , Adulto , Alanina/efeitos adversos , Alanina/farmacocinética , Alanina/farmacologia , Animais , Área Sob a Curva , Citosol/metabolismo , Feminino , Humanos , Cetonas/metabolismo , Macaca fascicularis , Masculino , Microssomos Hepáticos/metabolismo , Pessoa de Meia-Idade , NADP/metabolismo , Oxirredução , Ratos , Ratos Sprague-Dawley , Receptor Tipo 1 de Fator de Crescimento de Fibroblastos/antagonistas & inibidores , Triazinas/efeitos adversos , Triazinas/farmacologia , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/antagonistas & inibidores , Adulto Jovem
10.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(27): 2919-27, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21907643

RESUMO

A liquid chromatography-full scan high resolution accurate mass spectrometry (LC-HRMS) method for quantifying prednisone and prednisolone in human plasma using a quadrupole time-of-flight mass spectrometer (Q-TOF) was developed. Plasma samples were extracted using a liquid-liquid extraction procedure. Full scan data were acquired in the TOF only mode and extracted ion chromatograms were generated post-acquisition with the exact masses of the analytes. The calibration range was 5-2500 ng/mL, with a Lower Limit of Quantitation (LLOQ) of 5 ng/mL. The assay accuracy was between 98.4% and 106.3%. The between-run (inter-day) and within-run (intra-day) precision were within 1.7% and 2.9%, respectively. The matrix effect was between 0.98 and 1.10 for the six different lots of human plasma evaluated. Pooled incurred samples were analyzed by the method and the results matched those obtained from an LC-MS/MS method. In addition, qualitative information on phospholipids, and other endogenous components were also extracted from the full-scan data acquired.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Prednisolona/sangue , Prednisona/sangue , Mineração de Dados , Humanos , Análise dos Mínimos Quadrados , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Rapid Commun Mass Spectrom ; 25(19): 2863-78, 2011 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21913265

RESUMO

There is a growing interest in exploring the use of liquid chromatography coupled with full-scan high resolution accurate mass spectrometry (LC/HRMS) in bioanalytical laboratories as an alternative to the current practice of using LC coupled with tandem mass spectrometry (LC/MS/MS). Therefore, we have investigated the theoretical and practical aspects of LC/HRMS as it relates to the quantitation of drugs in plasma, which is the most commonly used matrix in pharmacokinetics studies. In order to assess the overall selectivity of HRMS, we evaluated the potential interferences from endogenous plasma components by analyzing acetonitrile-precipitated blank human plasma extract using an LC/HRMS system under chromatographic conditions typically used for LC/MS/MS bioanalysis with the acquisition of total ion chromatograms (TICs) using 10 k and 20 k resolving power in both profile and centroid modes. From each TIC, we generated extracted ion chromatograms (EICs) of the exact masses of the [M + H](+) ions of 153 model drugs using different mass extraction windows (MEWs) and determined the number of plasma endogenous peaks detected in each EIC. Fewer endogenous peaks are detected using higher resolving power, narrower MEW, and centroid mode. A 20 k resolving power can be considered adequate for the selective determination of drugs in plasma. To achieve desired analyte EIC selectivity and simultaneously avoid missing data points in the analyte EIC peak, the MEW used should not be too wide or too narrow and should be a small fraction of the full width at half maximum (FWHM) of the profile mass peak. It is recommended that the optimum MEW be established during method development under the specified chromatographic and sample preparation conditions. In general, the optimum MEW, typically ≤ ±20 ppm for 20 k resolving power, is smaller for the profile mode when compared with the centroid mode.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Preparações Farmacêuticas/sangue , Humanos , Modelos Teóricos , Peso Molecular , Preparações Farmacêuticas/química , Sensibilidade e Especificidade
12.
J Mass Spectrom ; 46(6): 595-601, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21630388

RESUMO

It can be argued that the last true paradigm shift in the bioanalytical (BA) arena was the shift from high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection to HPLC with tandem mass spectrometry (MS/MS) detection after the commercialization of the triple quadrupole mass spectrometer in the 1990s. HPLC-MS/MS analysis based on selected reaction monitoring (SRM) has become the gold standard for BA assays and is used by all the major pharmaceutical companies for the quantitative analysis of new drug entities (NCEs) as part of the new drug discovery and development process. While LC-MS/MS continues to be the best tool for drug discovery bioanalysis, a new paradigm involving high-resolution mass spectrometry (HRMS) and ultrahigh-pressure liquid chromatography (uHPLC) is starting to make inroads into the pharmaceutical industry. The ability to collect full scan spectra, with excellent mass accuracy, mass resolution, 10-250 ms scan speeds and no NCE-related MS parameter optimization, makes the uHPLC-HRMS techniques suitable for quantitative analysis of NCEs while preserving maximum qualitative information about other drug-related and endogenous components such as metabolites, degradants, biomarkers and formulation materials. In this perspective article, we provide some insight into the evolution of the hybrid quadrupole-time-of-flight (Qq-TOF) mass spectrometer and propose some of the desirable specifications that such HRMS systems should have to be integrated into the drug discovery bioanalytical workflow for performing integrated qualitative and quantitative bioanalysis of drugs and related components.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Descoberta de Drogas/métodos , Espectrometria de Massas em Tandem/métodos , Descoberta de Drogas/instrumentação , Descoberta de Drogas/normas , Descoberta de Drogas/tendências , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Biomed Chromatogr ; 24(1): 2-19, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20017121

RESUMO

This treatise summarizes the underlying principle and the road map for systematic LC-MS/MS bioanalytical method development. The three themes that have recently emerged as central to building quality during method development-phospholipids, incurred sample and sound chromatographic considerations-are the main focus of this article. In order to reduce the bioanalytical risk associated with plasma phospholipids, a dual approach involving extraction and chromatography is recommended. The use of incurred sample during method development is essential to avoid interference arising from drug-related components. This is different from the current practice of incurred sample reanalysis, which tests reproducibility during method application. LC column/mobile phase optimization is needed to achieve appropriate peak shape, sensitivity and the separation of the analyte from interfering metabolites and phospholipids. Related to sound chromatographic considerations, we lay out facts and myths related to UPLC, vis-à-vis HPLC. Incorporation of quality during method development avoids the costly experience of finding out by chance about the invalidity of a method after it has been used in support of a number of pivotal clinical and non-clinical studies. To this end, we put forth an outline of a protocol for a systematic LC-MS/MS bioanalytical method development.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Fosfolipídeos/análise , Humanos , Fosfolipídeos/sangue , Fosfolipídeos/química
14.
Anal Chem ; 81(18): 7839-43, 2009 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-19691295

RESUMO

The understanding and control of the in-source collision-induced dissociation (CID) of analytes is important for the accurate LC-MS/MS quantitation of drugs and metabolites in biological samples. Accordingly, it was of interest to us to establish whether such in-source CID takes place after and/or before the orifice of an electrospray ionization (ESI) mass spectrometer. A high-field asymmetric waveform ion mobility spectrometry (FAIMS) system that is physically located between the sprayer and the orifice of a mass spectrometer can serve as an ion filter to control ions entering the orifice of the mass spectrometer. In such a configuration, FAIMS could conceivably be used to determine if the in-source CID of an analyte occurs after and/or before the mass spectrometer orifice. We demonstrated this capability of FAIMS using ifetroban acylglucuronide metabolite as a model compound. Under the conditions used, the results showed that the in-source CID conversion of the acylglucuronide metabolite to its parent drug ifetroban occurred almost entirely after the orifice of the mass spectrometer, with the conversion upstream of the orifice accounting for only 5.6% of the conversion. Under the circumstance, the term "post-orifice CID" rather than "in-source CID" may be more appropriate in describing such a dissociation occurring in the front end of a mass spectrometer.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes/análise , Glucuronídeos/análise , Oxazóis/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Compostos Bicíclicos Heterocíclicos com Pontes/metabolismo , Glucuronídeos/química , Oxazóis/metabolismo , Espectrometria de Massas por Ionização por Electrospray/instrumentação
15.
Rapid Commun Mass Spectrom ; 23(14): 2125-38, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19517478

RESUMO

Because plasma phospholipids may cause matrix effects in bioanalytical liquid chromatography/tandem mass spectrometry (LC/MS/MS) methods, it is important to establish optimal mass spectrometric techniques to monitor the fate of phospholipids during method development and application. We evaluated three MS/MS techniques to monitor phospholipids using positive and negative electrospray ionization (ESI). The first technique is based on using positive precursor ion scan of m/z 184, positive neutral loss scan of 141 Da and negative precursor ion scan of m/z 153. The second technique is based on using class-specific positive and negative selected reaction monitoring (SRM) transitions to monitor class-representative phospholipids. The third technique, previously reported, utilizes in-source collision-induced dissociation (CID)-based positive SRM of m/z 184 --> 184. We recommend the all-inclusive technique 1 for use in qualitative assessment of all classes of phospholipids and technique 2 for use in quantitative assessment of class-representative phospholipids. Secondly, we evaluated the elution behaviors of the plasma phospholipids under different reversed-phase mobile phase conditions. The phospholipid-eluting strength of a mobile phase was mainly dependent on the type and amount (%) of the organic eluent and the strength increased in the order of methanol, acetonitrile and isopropyl alcohol. Under the commonly used gradient and isocratic elution schemes in LC/MS/MS bioanalysis, not all the phospholipids are eluted off the column. Thirdly, we investigated the association between phospholipids and matrix effects in positive and negative ESI using basic, acidic and neutral analytes. While the phospholipids caused matrix effects in both positive and negative ESI, the extent of ionization suppression was analyte-dependent and was inversely related to the retention factor and broadness of the phospholipids peaks. The lysophospholipids which normally elute earlier in reversed-phase chromatography are more likely to cause matrix effects compared to the later-eluting phospholipids in spite of the larger concentrations of the latter in plasma.


Assuntos
Cromatografia Líquida/métodos , Fosfolipídeos/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/instrumentação , Humanos , Espectrometria de Massas em Tandem/instrumentação
16.
Anal Chem ; 80(18): 7137-43, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18652493

RESUMO

As a continuation of the evaluation of the utility of high-field asymmetric waveform ion mobility spectrometry (FAIMS) in quantitative bioanalysis, we have developed a sensitive and selective method for the quantification of a peptide drug candidate in rat plasma using FAIMS coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). The LC-FAIMS-MS/MS method provided significant advantage over the corresponding LC-MS/MS method by reducing chemical/endogenous background noise associated with plasma matrix, thereby improving the sensitivity via increasing the signal-to-noise ratio. Linearity was established within 1-1000 nM in rat plasma, and the overall method accuracy and precision were good meeting the generally adopted acceptance criteria for a bioanalytical method. In a related investigation, we demonstrated the global selectivity of FAIMS from plasma endogenous components as a function of the compensation voltage (CV) across molecular masses that encompass small-molecule drugs. This work demonstrates that FAIMS coupled with LC-MS/MS can be highly advantageous in quantitative bioanalysis.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Peptídeos/sangue , Peptídeos/química , Animais , Calibragem , Peso Molecular , Peptídeos/uso terapêutico , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Rapid Commun Mass Spectrom ; 21(22): 3667-76, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17939154

RESUMO

The feasibility of developing a multi-component bioanalytical method using high-field asymmetric waveform ion mobility spectrometry coupled with liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-FAIMS-MS/MS) is demonstrated using nefazodone and its two metabolites as model compounds. The performance of the bioanalytical method for the three analytes, with three different compensation voltage (CV) values, is assessed using standard curves and quality control samples, which exhibited good accuracy, precision and ruggedness. The number of analytes with different CV values that can be quantitated simultaneously depends on the acquisition cycle time, which is a function of the FAIMS residence time (fixed), chromatographic peak width and selected reaction monitoring (SRM) dwell time. It is established that CV, the FAIMS selectivity parameter, is reproducible for at least 16 h, thus ensuring the constancy of the CV during a large-batch sample analysis. It is also established that change in mobile phase composition or of flow rate does not cause a shift in CV. Thus, CV values determined from a CV scan via infusion of a sample can be used for an LC/ESI-FAIMS-M/MS method based on isocratic or gradient elution.


Assuntos
Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Antidepressivos de Segunda Geração/análise , Antidepressivos de Segunda Geração/metabolismo , Cromatografia Líquida de Alta Pressão , Estudos de Viabilidade , Análise de Injeção de Fluxo , Íons/química , Piperazinas , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas em Tandem/instrumentação , Triazóis/análise , Triazóis/metabolismo
18.
J Pharm Biomed Anal ; 43(5): 1808-19, 2007 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-17236738

RESUMO

A rapid, selective and sensitive high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method coupled with high flow direct-injection on-line extraction has been developed and validated for the simultaneous quantitation of nefazodone and its three active metabolites, hydroxynefazodone, triazole-dione (BMS-180492) and m-chlorophyenylpiperazine (mCPP) in human plasma. The method utilized d7-nefazodone, d7-hydroxynefazodone, d4-BMS-180492 and d4-mCPP as internal standards (IS). The plasma samples were injected into the LC-MS/MS system after simply adding the internal standard solution and centrifuging. The required extraction and chromatographic separation of the analytes were achieved on an Oasis HLB column (on-line extraction column, 1 mm x 50 mm, 30 microm) and a conventional Luna C8 column (analytical column, 4.6 mm x 50 mm, 5 microm). Detection was by positive ion electrospray tandem mass spectrometry. The total analysis run time for each sample was 2 min, which included the time needed for on-line extraction, chromatographic separation and LC-MS/MS analysis. The assay was validated for each analyte and the concentrations ranged from 2.0 to 500 ng/ml for nefazodone, hydroxynefazodone and mCPP and from 4.0 to 1000 ng/ml for BMS-180492, respectively. The assay was used for the high-throughput sample analysis of thousands of pharmacokinetic study samples and was proven to be rapid, accurate, precise, sensitive, specific and rugged.


Assuntos
Antidepressivos de Segunda Geração/análise , Antidepressivos de Segunda Geração/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Triazóis/análise , Triazóis/sangue , Antidepressivos de Segunda Geração/química , Antidepressivos de Segunda Geração/metabolismo , Antidepressivos de Segunda Geração/farmacocinética , Humanos , Estrutura Molecular , Piperazinas/análise , Piperazinas/sangue , Piperazinas/química , Piperazinas/metabolismo , Piperazinas/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Fatores de Tempo , Triazóis/química , Triazóis/metabolismo , Triazóis/farmacocinética
19.
Drug Metab Dispos ; 35(4): 525-32, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17220241

RESUMO

The pharmacokinetics, metabolism, and excretion of sitagliptin [MK-0431; (2R)-4-oxo-4-[3-(trifluoromethyl)-5,6-dihydro[1,2,4]triazolo[4,3-a]pyrazin-7(8H)-yl]-1-(2,4,5-trifluorophenyl)butan-2-amine], a potent dipeptidyl peptidase 4 inhibitor, were evaluated in male Sprague-Dawley rats and beagle dogs. The plasma clearance and volume of distribution of sitagliptin were higher in rats (40-48 ml/min/kg, 7-9 l/kg) than in dogs ( approximately 9 ml/min/kg, approximately 3 l/kg), and its half-life was shorter in rats, approximately 2 h compared with approximately 4 h in dogs. Sitagliptin was absorbed rapidly after oral administration of a solution of the phosphate salt. The absolute oral bioavailability was high, and the pharmacokinetics were fairly dose-proportional. After administration of [(14)C]sitagliptin, parent drug was the major radioactive component in rat and dog plasma, urine, bile, and feces. Sitagliptin was eliminated primarily by renal excretion of parent drug; biliary excretion was an important pathway in rats, whereas metabolism was minimal in both species in vitro and in vivo. Approximately 10 to 16% of the radiolabeled dose was recovered in the rat and dog excreta as phase I and II metabolites, which were formed by N-sulfation, N-carbamoyl glucuronidation, hydroxylation of the triazolopiperazine ring, and oxidative desaturation of the piperazine ring followed by cyclization via the primary amine. The renal clearance of unbound drug in rats, 32 to 39 ml/min/kg, far exceeded the glomerular filtration rate, indicative of active renal elimination of parent drug.


Assuntos
Inibidores da Dipeptidil Peptidase IV , Inibidores Enzimáticos/farmacocinética , Hipoglicemiantes/farmacocinética , Pirazinas/farmacocinética , Triazóis/farmacocinética , Adenosina Desaminase/metabolismo , Inibidores de Adenosina Desaminase , Administração Oral , Animais , Bile/metabolismo , Disponibilidade Biológica , Biotransformação , Ciclização , Dipeptidil Peptidase 4/metabolismo , Cães , Inibidores Enzimáticos/administração & dosagem , Inibidores Enzimáticos/sangue , Inibidores Enzimáticos/urina , Fezes/química , Glucuronídeos/metabolismo , Glicoproteínas/antagonistas & inibidores , Glicoproteínas/metabolismo , Haplorrinos , Humanos , Hidroxilação , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/sangue , Hipoglicemiantes/urina , Técnicas In Vitro , Rim/metabolismo , Masculino , Microssomos Hepáticos/metabolismo , Estrutura Molecular , Oxirredução , Ligação Proteica , Pirazinas/administração & dosagem , Pirazinas/sangue , Pirazinas/urina , Ratos , Ratos Sprague-Dawley , Fosfato de Sitagliptina , Especificidade da Espécie , Ésteres do Ácido Sulfúrico/metabolismo , Triazóis/administração & dosagem , Triazóis/sangue , Triazóis/urina
20.
Drug Metab Dispos ; 35(2): 283-92, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17132765

RESUMO

(3R)-4-(4-Chlorobenzyl)-7-fluoro-5-(methylsulfonyl)-1,2,3,4-tetrahydrocyclopenta[b]indol-3-yl acetic acid (MK-0524) is a potent orally active human prostaglandin D(2) receptor 1 antagonist that is currently under development for the prevention of niacin-induced flushing. The major in vitro and in vivo metabolite of MK-0524 is the acyl glucuronic acid conjugate of the parent compound, M2. To compare metabolism of MK-0524 across preclinical species and humans, studies were undertaken to determine the in vitro kinetic parameters (K(m) and V(max)) for the glucuronidation of MK-0524 in Sprague-Dawley rat, beagle dog, cynomolgus monkey, and human liver microsomes, human intestinal microsomes, and in recombinant human UDP glucuronosyltransferases (UGT). A comparison of K(m) values indicated that UGT1A9 has the potential to catalyze the glucuronidation of MK-0524 in the liver, whereas UGT1A3 and UGT2B7 have the potential to catalyze the glucuronidation in the intestine. MK-0524 also was subject to phase I oxidative metabolism; however, the rate was significantly lower than that of glucuronidation. The rate of phase I metabolism was ranked as follows: rat approximately monkey > human intestine > dog > human liver with qualitatively similar metabolite profiles across species. In all the cases, the major metabolites were the monohydroxylated epimers (M1 and M4) and the keto-metabolite, M3. Use of inhibitory monoclonal antibodies and recombinant human cytochromes P450 suggested that CYP3A4 was the major isozyme involved in the oxidative metabolism of MK-0524, with a minor contribution from CYP2C9. The major metabolite in hepatocyte preparations was the acyl glucuronide, M2, with minor amounts of M1, M3, M4, and their corresponding glucuronides. Overall, the in vivo metabolism of MK-0524 is expected to proceed via glucuronidation, with minor contributions from oxidative pathways.


Assuntos
Hepatócitos/metabolismo , Indóis/metabolismo , Microssomos Hepáticos/metabolismo , Receptores Imunológicos/antagonistas & inibidores , Receptores de Prostaglandina/antagonistas & inibidores , Animais , Cromatografia Líquida , Cães , Glucuronídeos/metabolismo , Humanos , Macaca mulatta , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , NADP/metabolismo , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA