Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Rev Sci Instrum ; 90(12): 123301, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893832

RESUMO

High Temperature Ovens (HTOs) have widely been used to evaporate refractory materials in electron cyclotron resonance ion sources to produce hundreds of microamperes of multiply and highly charged metal ion beams. To meet the demands of milliamperes of multiply charged uranium and other heavy metal ion beams for future accelerators, a new and low-cost HTO is under development at Lawrence Berkeley National Laboratory for better long-term stability at high evaporation rates. ANSYS simulations have been carried out to optimize the new HTO with low heating current to reduce the electromagnetic forces as an HTO is immersed in the strong ECRIS magnetic fields. A larger loading volume is employed to deal with higher material consumption. Off-line tests have shown that the unloaded new HTO operates stably up to 1800-1900 °C with low temperature gradients and good repeatability. This paper presents and discusses the conceptual design features of the new HTO and off-line tests.

2.
Rev Sci Instrum ; 89(5): 052301, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864795

RESUMO

The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eµA 40Ar16+, 15 eµA 40Ar18+, 146 eµA 86Kr28+, 0.5 eµA 86Kr33+, 53 eµA 129Xe38+, and 17 eµA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR.

3.
Rev Sci Instrum ; 87(2): 02A702, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931920

RESUMO

To demonstrate a Mixed Axial and Radial field System (MARS) as the best magnet scheme for future ECRISs, MARS-D, a demonstrative ECRIS using a NbTi MARS magnet is progressing at Lawrence Berkeley National Laboratory. An optimized MARS design can use either NbTi or Nb3Sn coils with reduced engineering complexities to construct the needed high-field magnets. The optimized magnet design could enhance MARS-D to a next generation ECRIS by producing minimum-B field maxima of 5.6 T axially and 3.2 T radially for operating frequencies up to 45 GHz. In-progress test winding has achieved a milestone demonstrating the fabrication feasibility of a MARS closed-loop coil.

4.
Rev Sci Instrum ; 87(2): 02A736, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931954

RESUMO

The long-term operation of high charge state electron cyclotron resonance ion sources fed with high microwave power has caused damage to the plasma chamber wall in several laboratories. Porosity, or a small hole, can be progressively created in the chamber wall which can destroy the plasma chamber over a few year time scale. A burnout of the VENUS plasma chamber is investigated in which the hole formation in relation to the local hot electron power density is studied. First, the results of a simple model assuming that hot electrons are fully magnetized and strictly following magnetic field lines are presented. The model qualitatively reproduces the experimental traces left by the plasma on the wall. However, it is too crude to reproduce the localized electron power density for creating a hole in the chamber wall. Second, the results of a Monte Carlo simulation, following a population of scattering hot electrons, indicate a localized high power deposited to the chamber wall consistent with the hole formation process. Finally, a hypervapotron cooling scheme is proposed to mitigate the hole formation in electron cyclotron resonance plasma chamber wall.

5.
Rev Sci Instrum ; 85(2): 02A719, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593453

RESUMO

Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) is an advanced fully superconducting ECR ion source at IMP designed to be operational at the microwave frequency of 18-24 GHz. The existing SECRAL beam transmission line is composed of a solenoid lens and a 110° analyzing magnet. Simulations of particle tracking with 3D space charge effect and realistic 3D magnetic fields through the line were performed using particle-in-cell code. The results of the beam dynamics show that such a low energy beam is very sensitive to the space charge effect and significantly suffers from the second-order aberration of the analyzing magnet resulting in large emittance. However, the second-order aberration could be reduced by adding compensating sextupole components in the beam line. On this basis, a new 110° analyzing magnet with relatively larger acceptance and smaller aberration is designed and will be used in the design of low energy beam transport line for a new superconducting ECR ion source SECRAL-II. The features of the analyzer and the corresponding beam trajectory calculation will be detailed and discussed in this paper.

6.
Rev Sci Instrum ; 85(2): 02A922, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593501

RESUMO

A new superconducting Electron Cyclotron Resonance Ion Source (ECRIS) is under development at LBNL to harness the winding techniques of a closed-loop sextupole coil for the next generation ECRIS and to enhance the capability of the 88-in. cyclotron facility. The proposed ECRIS will use a superconducting closed-loop sextupole coil to produce the radial field and a substantial portion of the axial field. The field strengths of the injection, central and extraction regions are adjusted by a three solenoids outside the closed-loop sextupole coil. In addition to maintaining the typical ECRIS magnetic field configuration, this new source will also be able to produce a dustpan-like minimum-B field to explore possible ECRIS performance enhancement. The dustpan-like minimum-B field configuration has about the same strengths for the maximum axial field at the injection region and the maximum radial pole fields at the plasma chamber walls but it can be substantially lower at the extraction region. The dustpan-like minimum-B will have a field maximum Bmax ≥ 2.6 T for operations up to 18 GHz with a ratio of Bmax/Bres ≥ 4 and higher ratios for lower frequencies. The field maxima of this new source can reach over 3 T both at the injection and the plasma chamber walls which could also support operation at 28 GHz. The source will be built of cryogen-free with the magnets directly cooled by cryo-coolers to simplify the cryostat structure. The source design features will be presented and discussed.

7.
Rev Sci Instrum ; 84(3): 033306, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556814

RESUMO

A low energy beam transport (LEBT) system has been built for a compact pulsed hadron source (CPHS) at Tsinghua University in China. The LEBT, consisting of two solenoids and three short-drift sections, transports a pulsed proton beam of 60 mA of energy of 50 keV to the entrance of a radio frequency quadrupole (RFQ). Measurement has shown a normalized RMS beam emittance less than 0.2 π mm mrad at the end of the LEBT. Beam simulations were carried out to compare with the measurement and are in good agreement. Based on the successful CPHS LEBT development, a new LEBT for a China ADS projector has been designed. The features of the new design, including a beam chopper and beam simulations of the LEBT are presented and discussed along with CPHS LEBT development in this article.

8.
Rev Sci Instrum ; 83(2): 02A302, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380149

RESUMO

High field and high frequency have been leading the development of electron cyclotron resonance ion sources (ECRISs) in the past decade as demonstrated by the achieved great performance. The present superconducting magnet structures built with NbTi wires have reached an axial field of 3.5-4.0 T and a radial field of 2.0 T for operating frequency up to 28 GHz. Further increase of the magnetic field strength will require higher current superconductor, i.e., Nb(3)Sn wires. This paper will present the features of a new superconducting magnet structure and review of the existing structures. Using NbTi wires, the new magnet structure could be able to produce maximum fields of 7.0 T on axis and radial field of 3.7 T at a hexagonal plasma chamber wall for ECRIS operations up to 50 GHz. If this new magnet can be built with Nb(3)Sn wires, much higher fields can be expected.

9.
Rev Sci Instrum ; 83(2): 02A320, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380167

RESUMO

SECRAL (superconducting ECR ion source with advanced design in Lanzhou) ion source has been in routine operation for Heavy Ion Research Facility in Lanzhou (HIRFL) accelerator complex since May 2007. To further enhance the SECRAL performance in order to satisfy the increasing demand for intensive highly charged ion beams, 3-5 kW high power 24 GHz single frequency and 24 GHz +18 GHz double frequency with an aluminum plasma chamber were tested, and some exciting results were produced with quite a few new record highly charged ion beam intensities, such as (129)Xe(35+) of 64 eµA, (129)Xe(42+) of 3 eµA, (209)Bi(41+) of 50 eµA, (209)Bi(50+) of 4.3 eµA and (209)Bi(54+) of 0.2 eµA. In most cases SECRAL is operated at 18 GHz to deliver highly charged heavy ion beams for the HIRFL accelerator, only for those very high charge states and very heavy ion beams such as (209)Bi(36+) and (209)Bi(41+), SECRAL has been operated at 24 GHz. The total operation beam time provided by SECRAL up to July 2011 has exceeded 7720 hours. In this paper, the latest performance, development, and operation status of SECRAL ion source are presented. The latest results and reliable long-term operation for the HIRFL accelerator have demonstrated that SECRAL performance for production of highly charged heavy ion beams remains improving at higher RF power with optimized tuning.

10.
Rev Sci Instrum ; 83(2): 02A328, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380175

RESUMO

A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.


Assuntos
Ciclotrons , Elétrons , Radiometria/instrumentação , Desenho de Equipamento
11.
Rev Sci Instrum ; 83(2): 02A329, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380176

RESUMO

The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.

12.
Rev Sci Instrum ; 83(2): 02B303, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380282

RESUMO

A laser (Nd:YAG laser, 3 J, 1064 nm, 8-10 ns) ion source has been built and under development at IMP to provide pulsed high-charge-state heavy ion beams to a radio frequency quadrupole (RFQ) for upgrading the IMP accelerators with a new low-energy beam injector. The laser ion source currently operates in a direct plasma injection scheme to inject the high charge state ions produced from a solid target into the RFQ. The maximum power density on the target was about 8.4 × 10(12) W∕cm(2). The preliminary experimental results will be presented and discussed in this paper.

13.
Rev Sci Instrum ; 83(2): 02B726, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380331

RESUMO

Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

14.
Rev Sci Instrum ; 81(2): 02A202, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192321

RESUMO

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e microA of (129)Xe(43+), 22 e microA of (209)Bi(41+), and 1.5 e microA of (209)Bi(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e microA of (129)Xe(27+) and 152 e microA of (129)Xe(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and (129)Xe(27+), (78)Kr(19+), (209)Bi(31+), and (58)Ni(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

15.
Rev Sci Instrum ; 81(2): 02A318, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192339

RESUMO

Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e microA of Xe(37+), 1 e microA of Xe(43+), and 0.16 e microA of Ne-like Xe(44+). To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi(31+) beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e microA of Bi(31+), 22 e microA of Bi(41+), and 1.5 e microA of Bi(50+) have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.

16.
Rev Sci Instrum ; 79(2 Pt 2): 02A315, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315105

RESUMO

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

17.
Rev Sci Instrum ; 79(2 Pt 2): 02B711, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315202

RESUMO

To satisfy the requirements of surface and atomic physics study in the field of low energy multiple charge state ion incident experiments, a low energy (10 eV/q-20 keV/q) ion beam platform is under design at IMP. A simple test bench has been set up to test the ion beam deceleration systems. Considering virtues such as structure simplicity, easy handling, compactness, cost saving, etc., an all-permanent magnet ECRIS LAPECR1 [Lanzhou all-permanent magnet electron cyclotron resonance (ECR) ion source No. 1] working at 14.5 GHz has been adopted to produce intense medium and low charge state ion beams. LAPECR1 source has already been ignited. Some intense low charge state ion beams have been produced on it, but the first test also reveals that many problems are existing on the ion beam transmission line. The ion beam transmission mismatches result in the depressed performance of LAPECR1, which will be discussed in this paper. To obtain ultralow energy ion beam, after being analyzed by a double-focusing analyzer magnet, the selected ion beam will be further decelerated by two afocal deceleration lens systems, which is still under design. This design has taken into consideration both ions slowing down and also ion beam focusing. In this paper, the conceptual design of deceleration system will be discussed.

18.
Zhonghua Wai Ke Za Zhi ; 31(1): 43-5, 1993 Jan.
Artigo em Chinês | MEDLINE | ID: mdl-8404343

RESUMO

The authors report a self-designed procedure of deltoid spina scapula muscular pedicle bone graft which is suitable for treatment of humeral bone tumor, traumatic bone defect, bone infection or anomalies involving the shoulder region and the humerus when bone graft is needed. The results of preliminary application in 11 cases show that owing to good quality and satisfactory quantity of the graft rich in vascularization, this procedure is reliable, easy to perform and facilitates rapid bone healing.


Assuntos
Úmero/cirurgia , Pseudoartrose/cirurgia , Retalhos Cirúrgicos/métodos , Adolescente , Adulto , Neoplasias Ósseas/cirurgia , Transplante Ósseo , Criança , Feminino , Tumores de Células Gigantes/cirurgia , Humanos , Úmero/lesões , Masculino , Pessoa de Meia-Idade , Músculos/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA