Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Se Pu ; 42(5): 445-451, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736387

RESUMO

Mycotoxins are toxic secondary metabolites produced by fungal species that can cause acute, subacute, and chronic toxicity in humans and animals. Thus, these toxins pose a significant threat to health and safety. Owing to the lack of effective antimold measures in the agricultural industry, feed ingredients such as corn, peanuts, wheat, barley, millet, nuts, oily feed, forage, and their byproducts are prone to mold and mycotoxin contamination, which can affect animal production, product quality, and safety. Cyclopiazonic acid (CPA), which is mainly biosynthesized from mevalonate, tryptophan, and diacetate units, is a myotoxic secondary metabolite produced by Penicillium and Aspergillus fungi. CPA is widely present as a copollutant with aflatoxins in various crops. Compared with some common mycotoxins such as aflatoxins, fumonisins, ochratoxins, zearalenones, and their metabolites, CPA has not been well investigated. In the United States, a survey showed that 51% of corn and 90% of peanut samples contained CPA, with a maximum level of 2.9 mg/kg. In Europe, CPA was found in Penicillium-contaminated cheeses as high as 4.0 mg/kg. Some studies have shown that CPA can cause irreversible damage to organs such as the liver and spleen in mice. Therefore, the establishment of a rapid and efficient analytical method for CPA is of great significance for the risk assessment of CPA in feeds, the development of standard limits, and the protection of feed product quality and safety. The QuEChERS method, a sample pretreatment method that is fast, simple, cheap, effective, and safe, is widely used in the analysis of pesticide residues in food. In this study, a modified QuEChERS method combined with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was used to determine CPA levels in feeds. The chromatographic separation and MS detection of CPA as well as the key factors affecting the extraction efficiency of CPA, including the type of extraction solvent, type of inorganic salt, and type and dosage of adsorbent, were optimized in detail. During the optimization of the chromatographic-separation step, the acid and salt concentrations of the mobile phase affected the separation and detection of CPA. During the optimization of the QuEChERS method, the addition of a certain amount of acetic acid improved the extraction efficiency of CPA because of its acidic nature; in addition, GCB and PSA significantly adsorbed CPA from the feed extract. Under optimal conditions, the CPA in the feed sample (1.0 g) was extracted with 2 mL of water and 4 mL of acetonitrile (ACN) containing 0.5% acetic acid. After salting out with 0.4 g of NaCl and 1.6 g of MgSO4, 1 mL of the ACN supernatant was purified by dispersive solid-phase extraction using 150 mg of MgSO4 and 50 mg of C18 and analyzed by UPLC-MS/MS. The sample was separated on a Waters HSS T3 column (100 mm×2.1 mm, 1.8 µm) using 2 mmol/L ammonium acetate aqueous solution with 0.5% formic acid and ACN as the mobile phases and then analyzed by positive electrospray ionization in multiple reaction monitoring mode. CPA exhibited good linearity in the range of 2-200 ng/mL, with a high correlation coefficient (r=0.9995). The limits of detection and quantification of CPA, which were calculated as 3 and 10 times the signal-to-noise ratio, respectively, were 0.6 and 2.0 µg/kg, respectively. The average recoveries in feed samples spiked with 10, 100, and 500 µg/kg CPA ranged from 70.1% to 78.5%, with an intra-day precision of less than 5.8% and an inter-day precision of less than 7.2%, indicating the good accuracy and precision of the proposed method. Finally, the modified QuEChERS-UPLC-MS/MS method was applied to the analysis of CPA in 10 feed samples obtained from Wuhan market. The analysis results indicated that the developed method has good applicability for CPA analysis in feed samples. In summary, an improved QuEChERS method was applied to the extraction and purification of CPA from feeds for the first time; this method provides a suitable analytical method for the risk monitoring, assessment, and standard-limit setting of CPA in feed samples.


Assuntos
Ração Animal , Contaminação de Alimentos , Indóis , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Ração Animal/análise , Cromatografia Líquida de Alta Pressão/métodos , Contaminação de Alimentos/análise , Indóis/análise , Micotoxinas/análise
2.
PLoS One ; 19(5): e0303751, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38768114

RESUMO

Increasing yield is an important goal of barley breeding. In this study, 54 papers published from 2001-2022 on QTL mapping for yield and yield-related traits in barley were collected, which contained 1080 QTLs mapped to the barley high-density consensus map for QTL meta-analysis. These initial QTLs were integrated into 85 meta-QTLs (MQTL) with a mean confidence interval (CI) of 2.76 cM, which was 7.86-fold narrower than the CI of the initial QTL. Among these 85 MQTLs, 68 MQTLs were validated in GWAS studies, and 25 breeder's MQTLs were screened from them. Seventeen barley orthologs of yield-related genes in rice and maize were identified within the hcMQTL region based on comparative genomics strategy and were presumed to be reliable candidates for controlling yield-related traits. The results of this study provide useful information for molecular marker-assisted breeding and candidate gene mining of yield-related traits in barley.


Assuntos
Estudo de Associação Genômica Ampla , Hordeum , Locos de Características Quantitativas , Hordeum/genética , Hordeum/crescimento & desenvolvimento , Mapeamento Cromossômico , Melhoramento Vegetal , Fenótipo , Genoma de Planta , Genes de Plantas
3.
Artigo em Inglês | MEDLINE | ID: mdl-38710536

RESUMO

AIMS: Atrial fibrillation/atrial flutter (AF/AFL) remains a significant public health concern on a global scale, with metabolic risks playing an increasingly prominent role. This study aimed to investigate comprehensive epidemiological data and trends concerning the metabolic risks related-AF/AFL burden based on the data from the Global Burden of Disease (GBD) study 2019. METHODS & RESULTS: The analysis of disease burden focused on numbers, age-standardized rates (ASR) of deaths, disability-adjusted life years (DALYs), and estimated annual percentage change (EAPC), while considering factors of age, sex, sociodemographic index (SDI), and locations. In 2019, there was a culmination of 137 179 deaths and 4 099 146 DALYs caused by metabolic risks related-AF/AFL worldwide, with an increase of 162.95% and 120.30% respectively from 1990. High and high-middle SDI regions predominantly carried the burden of AF/AFL associated with metabolic risks, while a shift towards lower SDI regions had been occurring. Montenegro had the highest recorded death rate (7.6 per 100 000) and DALYs rate (146.3 per 100 000). An asymmetrically inverted V-shaped correlation was found between SDI and deaths/DALYs rates. Moreover, females and the elderly exhibited higher AF/AFL burdens, and young adults (over 40 years old) also experienced an annual increase. CONCLUSIONS: The global AF/AFL burden related to metabolic risks has significantly increased over past three decades, with considerable spatiotemporal, gender-based, and age-related heterogeneity. These findings shed valuable light on the trends in the burden of metabolic risks related-AF/AFL, and offered insights into corresponding strategies.

4.
BMC Med ; 21(1): 461, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996906

RESUMO

BACKGROUND: High-power short-duration (HPSD) ablation strategy has emerged as a popular approach for treating atrial fibrillation (AF), with shorter ablation time. The utilized Smart Touch Surround Flow (STSF) catheter, with 56 holes around the electrode, lowers electrode-tissue temperature and thrombus risk. Thus, we conducted this prospective, randomized study to investigate if the HPSD strategy with STSF catheter in AF ablation procedures reduces the silent cerebral embolism (SCE) risk compared to the conventional approach with the Smart Touch (ST) catheter. METHODS: From June 2020 to September 2021, 100 AF patients were randomized 1:1 to the HPSD group using the STSF catheter (power set at 50 W) or the conventional group using the ST catheter (power set at 30 to 35 W). Pulmonary vein isolation was performed in all patients, with additional lesions at operator's discretion. High-resolution cerebral diffusion-weighted magnetic resonance imaging (hDWI) with slice thickness of 1 mm was performed before and 24-72 h after ablation. The incidence of new periprocedural SCE was defined as the primary outcome. Cognitive performance was assessed using the Montreal Cognitive Assessment (MoCA) test. RESULTS: All enrolled AF patients (median age 63, 60% male, 59% paroxysmal AF) underwent successful ablation. Post-procedural hDWI identified 106 lesions in 42 enrolled patients (42%), with 55 lesions in 22 patients (44%) in the HPSD group and 51 lesions in 20 patients (40%) in the conventional group (p = 0.685). No significant differences were observed between two groups regarding the average number of lesions (p = 0.751), maximum lesion diameter (p = 0.405), and total lesion volume per patient (p = 0.669). Persistent AF and CHA2DS2-VASc score were identified as SCE determinants during AF ablation procedure by multivariable regression analysis. No significant differences in MoCA scores were observed between patients with SCE and those without, both immediately post-procedure (p = 0.572) and at the 3-month follow-up (p = 0.743). CONCLUSIONS: Involving a small sample size of 100 AF patients, this study reveals a similar incidence of SCE in AF ablation procedures, comparing the HPSD strategy using the STSF catheter to the conventional approach with the ST catheter. TRIAL REGISTRATION: Clinicaltrials.gov: NCT04408716. AF = Atrial fibrillation, DWI = Diffusion-weighted magnetic resonance imaging, HPSD = High-power short-duration, ST = Smart Touch, STSF = Smart Touch Surround Flow.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Embolia Intracraniana , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos Prospectivos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/prevenção & controle , Incidência , Técnicas de Ablação/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
5.
Pacing Clin Electrophysiol ; 46(12): 1576-1585, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37987556

RESUMO

Anticoagulation therapy plays a crucial role in the management of atrial fibrillation (AF), considering the high morbidity and mortality of AF-related ischemic strokes. With the plausible hypothesis that left atrial appendage is the main source of thrombus in AF patients, left atrial appendage closure (LAAC) has been regarded as a potential substitute to oral anticoagulation in order to meet the unmet needs for stroke prevention, particularly in patients with high bleeding risk. Notable advancements in safety, efficacy, and device innovation have been made in recent years, albeit concerns still remain regarding the insufficient efficacy data, device-related complications, and the need for procedural optimization. We aim to review current knowledge about LAAC and provide potential future directions for the remaining key issues.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Resultado do Tratamento , Hemorragia/induzido quimicamente , Apêndice Atrial/cirurgia , Anticoagulantes
6.
Biomed Pharmacother ; 167: 115579, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37776637

RESUMO

Lutein is a strong antioxidant with anti-inflammatory, anti-oxidative and cardioprotective effects and could be a promising candidate for the treatment of hypertensive heart disease (HHD), but is not clinically appealing because of its low oral bioavailability and main distribution in the eyes. To address this, a biomimetic drug delivery system-MMLNPs was established by coating macrophage membranes (MMs) onto lutein-loaded poly (lactic-co-glycolic acid) (PLGA) nanoparticles (LNPs). This study characterized the physical properties of biomimetic nanoparticles and examined the targeting capability, therapeutic effects and mechanism, and biosecurity of administering them for cardiac fibrosis therapy in the transverse aortic constriction (TAC) model and in vitro. Transmission electron microscope mapping and dynamic light scattering analysis proved that MMLNPs were spherical nanoparticles camouflaged by a layer of cell membrane and had negative zeta potential. Confocal laser scanning microscopy and flow cytometry analysis showed that MMs on the biomimetic nanoparticles hindered the phagocytosis of macrophages and facilitated the targeting of activated endothelial cells. Ex vivo fluorescence imaging experiments demonstrated the targeting of biomimetic nanoparticles to the injured heart. EdU assay indicated that MMLNPs have the same potential to inhibit angiotensin (Ang) II-induced cardiac fibroblast proliferation as free lutein. Furthermore, echocardiography showed that MMLNPs improved cardiac function and structure, and Masson staining and western blotting showed that MMLNPs ameliorated cardiac fibrosis. We found MMLNPs inhibited the interleukin (IL)-11/ERK signaling pathway which was up-regulated in the TAC model compared to the sham-operated mouse. Biochemical testing and hematoxylin and eosin staining proved that the long-term use of MMLNPs lacked biological toxicity. Collectively, MMLNPs might be a promising nanodrug delivery approach to attenuate pressure overload (PO)-induced cardiac fibrosis.


Assuntos
Luteína , Nanopartículas , Camundongos , Animais , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Luteína/farmacologia , Luteína/uso terapêutico , Biomimética , Células Endoteliais , Fibrose , Nanopartículas/química , Macrófagos/metabolismo
7.
J Cardiovasc Electrophysiol ; 34(1): 117-125, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36403284

RESUMO

INTRODUCTION: Intramural or epicardial locations of the arrhythmogenic substrate are regarded as one of the main reasons for radiofrequency (RF) catheter ablation failure. This study aims to conduct a comprehensive analysis of various factors including baseline impedance, irrigant and electrode configuration at similar ablation index (AI) value. METHODS: In 12 ex vivo swine hearts, RF ablation was performed at a target AI value of 500 and a multistep impedance load (100-180 Ω) in 4 settings: (1) conventional unipolar configuration with an irrigant of normal saline (NS); (2) conventional unipolar configuration with an irrigant of half normal saline (HNS); (3) bipolar configuration with an irrigant of NS; (4) sequential unipolar configuration with an irrigant of NS. The relationships between lesion dimensions and above factors were examined. RESULTS: Baseline impedance had a strong negative linear correlation with lesion dimensions at a certain AI. The correlation coefficient between baseline impedance and depth, width, and volume were R = -0.890, R = -0.755 and R = -0.813, respectively (p < .01). There were 10 (total: 10/100, 10%; bipolar: 10/25, 40%) transmural lesions during the whole procedure. Bipolar ablation resulted in significantly deeper lesion than other electrode configurations. Other comparisons in our experiment did not achieve statistical significance. CONCLUSION: There is a strong negative linear correlation between baseline impedance and lesion dimensions at a certain AI value. Baseline impedance has an influence on the overall lesion dimensions among irrigated fluid and ablation configurations. Over a threshold impedance of 150 Ω, the predictive accuracy of AI can be compromised.


Assuntos
Ablação por Cateter , Solução Salina , Suínos , Animais , Impedância Elétrica , Coração , Eletrodos , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
Artigo em Inglês | MEDLINE | ID: mdl-36429845

RESUMO

Electroencephalogram (EEG) signals are the gold standard tool for detecting epileptic seizures. Long-term EEG signal monitoring is a promising method to realize real-time and automatic epilepsy detection with the assistance of computer-aided techniques and the Internet of Medical Things (IoMT) devices. Machine learning (ML) algorithms combined with advanced feature extraction methods have been widely explored to precisely recognize EEG signals, while among which, little attention has been paid to high computing costs and severe information losses. The lack of model interpretability also impedes the wider application and deeper understanding of ML methods in epilepsy detection. In this research, a novel feature extraction method based on an autoencoder (AE) is proposed in the time domain. The architecture and mechanism are elaborated. In this method, specified features are defined and calculated on the basis of signal reconstruction quantification of the AE. The EEG recognition is performed to validate the effectiveness of the proposed detection method, and the prediction accuracy reached 97%. To further investigate the superiority of the proposed AE-based feature extraction method, a widely used feature extraction method, PCA, is allocated for comparison. In order to understand the underlying working mechanism, permutation importance and SHapley Additive exPlanations (SHAP) are conducted for model interpretability, and the results further confirm the reasonability and effectiveness of the extracted features by AE reconstruction. With high computing efficiency in the time domain and an extensively satisfactory accuracy, the proposed epilepsy detection method exhibits great superiority and potential in almost real-time and automatic epilepsy monitoring.


Assuntos
Epilepsia , Internet das Coisas , Humanos , Eletroencefalografia , Epilepsia/diagnóstico , Aprendizado de Máquina , Algoritmos
9.
Front Cardiovasc Med ; 9: 937913, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35872904

RESUMO

Objective: To evaluate the efficacy and safety of lower ablation indexes (AI) guided pulmonary vein isolation (PVI) in treating paroxysmal atrial fibrillation (AF). Methods: Ninety patients with paroxysmal AF scheduled for radiofrequency ablation were randomly divided into three groups. The AI targets for PVI were as follows: In group A/B/C, 550/500/450 for roof and anterior wall, and 400/350/300 for posterior/inferior wall. The first-pass PVI rate, ablation time, complications and recurrence of atrial tachyarrhythmia (ATa) were compared. Results: The mean age was 62.5 years (male: 63.0%), mean body mass index (BMI): 24.35 ± 3.66 kg/m2. The baseline characteristics were comparable. There was no significant difference in the first-pass PVI rate among the three groups (left-sided-PV: 66.7% vs. 80% vs. 73.3%, P = 0.51; right-sided-PV: 70% vs. 83.3% vs. 73.3%, P = 0.64), also with similar gap rate during the procedural waiting time. At 1-year follow-up there was no significant difference in the recurrence rate of ATa among the three groups (10% vs. 13.3% vs. 13.3%, P = 1.00). The ablation time in the Group C was significantly less than that in the other two groups (47.8 min. vs. 47.0 min. vs. 36.6 min, P < 0.001). Higher AI seemed to link a non-significant trend toward higher rate of pericardial effusion (group A + B vs. group C:6.7% vs. 0%, P = 0.30), although the rate of overall complications was not different among the three groups. Conclusion: This randomized study shows that, a relatively lower target AI guided ablation may be similarly effective to achieve PVI with significantly reduced ablation time and obtain similar clinical outcome in treating paroxysmal AF in Asian population. Clinical Trial Registration: [www.ClinicalTrials.gov], identifier [NCT:04549714].

10.
J Cardiovasc Dev Dis ; 9(6)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35735817

RESUMO

Cardioneuroablation (CNA) is proposed as a promising therapy for patients with sinoatrial node dysfunction (SND) that is mediated by excessive vagal tone. However, a series of urgent questions about CNA remain unanswered. From December 2020 to March 2022, six patients with symptomatic SND who underwent CNA were summarized in this report. Sequential CNA targeting Ao-SVC GP, PMLGP, RAGP, and LSGP was performed in patients, guided by fractionated intracardiac electrograms and dynamically evaluated by extracardiac vagal stimulation (ECVS). The results showed that Ao-SVC GP ablation led to a significant increase in heart rate (HR) and the elimination of sinus arrest evoked by ECVS, while the vagal responses of atrial ventricular block were eliminated by the ablation of PMLGP and LSGP. Post-procedure HR increased up to 64-86% of the maximum HR of an atropine test at baseline. The median HR from Holter monitoring increased from 52.8 ± 2.1 bpm at baseline to 73.0 ± 10.4 bpm after the procedure (p = 0.012) and to 71.3 ± 10.1 bpm at the six-month follow-up (p = 0.011). Bradycardia-related symptoms disappeared in all patients at the six-month follow-up. This case series reveals the feasibility of using the ECVS-assisted sequential CNA technique and indicates the critical role of ECVS in dynamically evaluating the impact of sequential CNA on the vagal control of SAN and AVN.

11.
J Cardiovasc Dev Dis ; 9(2)2022 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-35200699

RESUMO

Left atrial appendage thrombus (LAAT) is a surrogate of thromboembolic events in patients with nonvalvular atrial fibrillation (NVAF). We aimed to investigate the risk factors for LAAT formation before catheter ablation and cardioversion beside the CHA2DS2-VASc score. In this case-control study, patients with NVAF who underwent transesophageal echocardiography (TEE) were included. Demographic data, laboratory results, and echocardiographic measurements were retrospectively collected. Logistic regression analysis was performed to determine risk factors predicting LAAT. Of the 543 included patients, LAAT was identified in 50 patients (9.2%). Multivariable logistic regression analysis for the entire cohort showed that NT-proBNP (per 500 ng/L increase, OR (95% CI): 1.09 (1.00-1.19), p = 0.038) and LDL-C (per 1 mmol/L increase, OR (95% CI): 1.70 (1.05-2.77), p = 0.032) were independently correlated with the presence of LAAT after the adjustment for CHA2DS2-VASc score and anticoagulant therapy. The subgroup analysis of patients without anticoagulant therapy also yielded similar results. Regarding patients with CHA2DS2-VASc scores ≤ 1, a higher level of LDL-C (per 1 mmol/L increase, OR (95% CI): 6.31 (2.38-16.74), p < 0.001) independently correlated with the presence of LAAT. The present study suggests that beyond CHA2DS2-VASc score, raised NT-proBNP and LDL-C are additional predictors for LAAT in NVAF patients.

12.
Front Cardiovasc Med ; 8: 802306, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35071366

RESUMO

Fish oil is rich in unsaturated fatty acids, i.e., eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), both of which are widely distributed in the body such as heart and brain. In vivo and in vitro experiments showed that unsaturated fatty acids may have effects of anti-inflammation, anti-oxidation, protecting vascular endothelial cells, thrombosis inhibition, modifying autonomic nerve function, improving left ventricular remodeling, and regulating blood lipid. Given the relevance to public health, there has been increasing interest in the research of potential cardioprotective effects of fish oil. Accumulated evidence showed that fish oil supplementation may reduce the risk of cardiovascular events, and, in specific, it may have potential benefits in improving the prognosis of patients with hypertension, coronary heart disease, cardiac arrhythmias, or heart failure; however, some studies yielded inconsistent results. In this article, we performed an updated systematical review in order to provide a contemporary understanding with regard to the effects of fish oil on cardiovascular diseases.

13.
ACS Appl Mater Interfaces ; 11(26): 23006-23017, 2019 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-31136144

RESUMO

Myocardial fibrosis plays an important role in the development of heart failure and malignant arrhythmia, which potentially increases the incidence of sudden cardiac death. Therefore, early detection of myocardial fibrosis is of great significance for evaluating the prognosis of patients and formulating appropriate treatment strategies. Late gadolinium-enhanced magnetic resonance imaging is considered as the currently effective strategy for noninvasive detection of myocardial fibrosis, but it still suffers from some critical issues. In this work, multifunctional CNA35-labeled perfluoropentane nanoparticles (CNA35-PFP NPs) have been elaborately designed and constructed for molecular imaging of fibrotic myocardium based on ultrasound imaging. These as-constructed CNA35-PFP NPs are intravenously infused into rabbit circulation with an animal model of myocardial infarction. Especially, these targeted CNA35-PFP NPs with nanoscale size could efficiently pass through the endothelial cell gap and adhere to the surface of fibroblasts in the fibrotic myocardium. Importantly, followed by low-intensity focused ultrasound irradiation on the myocardium, these intriguing CNA35-PFP NPs could transform from liquid into gaseous microbubbles, which further significantly enhanced the ultrasound contrast in the fibrotic area, facilitating the detection by diagnostic ultrasound imaging. Therefore, this work provides a desirable noninvasive, economical, and real-time imaging technique for the assessment of cardiac fibrosis with diagnostic ultrasound based on the rational design of liquid-to-gas phase-changeable nanoplatforms.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Fibrose/diagnóstico por imagem , Nanocompostos/química , Ultrassonografia/métodos , Animais , Cardiomiopatias/patologia , Colágeno/química , Modelos Animais de Doenças , Fibrose/patologia , Coração/diagnóstico por imagem , Coração/fisiopatologia , Humanos , Miocárdio/patologia , Nanocompostos/uso terapêutico , Nanopartículas/química , Coelhos
14.
IDCases ; 12: 149-150, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29942775
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA