Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Talanta ; 272: 125839, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38428134

RESUMO

A nitrogen-doped carbon shell loaded with a gold and silver alloy (Au/Ag@NCS) was constructed for highly sensitive electrochemical detection of NO. The Au/Ag@NCS material was prepared by use of SiO2 particles as a template to polymerize imidazolium-based ionic liquids loaded with gold and silver salts, and subsequent carbonization treatment and template removal. The hollow structure of the carbon material acted as a carrier for electrochemical sensing, offering high specific surface area, large pore capacity, robust electron conductivity, and excellent mechanical stability. The inclusion of gold in the composite enhanced its catalytic and sensing capabilities, while silver oxidation was employed as a reference signal for accurate detection. By utilization of the Au/Ag@NCS-modified electrode, a wide detection range from 0.5 nM to 1.05 µM with a low detection limit of 0.32 nM was achieved for NO detection. The electrochemical sensor also exhibited high selectivity and excellent stability. The fabricated sensor was further utilized to explore the release of NO from breast cancer cells, revealing that the electrochemical platform could be regarded as an important method to study the daily tests of NO in clinical application.

2.
Mikrochim Acta ; 191(3): 121, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308135

RESUMO

Hydroxyl radical (•OH) detection is pivotal in medicine, biochemistry and environmental chemistry. Yet, electrochemical method-specific detection is challenging because of hydroxyl radicals' high reactivity and short half-life. In this study, we aimed to modify the electrode surface with a specific recognition probe for •OH. To achieve this, we conducted a one-step hydrothermal process to fabricate a CoZnMOF bimetallic organic framework directly onto conductive graphite paper (Gp). Subsequently, we introduced salicylic acid (SA) and methylene blue (MB), which easily penetrated the pores of CoZnMOF. By selectively capturing •OH by SA and leveraging the electrochemical signal generated by the reaction product, we successfully developed an electrochemical sensor Gp/CoZnMOF/SA + MB. The prepared sensor exhibited a good linear relationship with •OH concentrations ranging from 1.25 to 1200 nM, with a detection limit of 0.2 nM. Additionally, the sensor demonstrated excellent reproducibility and accuracy due to the incorporation of an internal reference. It exhibited remarkable selectivity for •OH detection, unaffected by other electrochemically active substances. The establishment of this sensor provides a way to construct MOF-modified sensors for the selective detection of other reactive oxygen species (ROS), offering a valuable experimental basis for ROS-related disease research and environmental safety investigations.

3.
Luminescence ; 39(2): e4667, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38178733

RESUMO

Ciprofloxacin (CIP) is a widely used broad-spectrum antibiotic and has been associated with various side effects, making its accurate detection crucial for patient safety, drug quality compliance, and environmental and food safety. This study presents the development of a ternary nucleotide-lanthanide coordination nanoprobe, GMP-Tb-BDC (GMP: guanosine 5'-monophosphate, BDC: 2-amino-1,4-benzenedicarboxylic acid), for the sensitive and ratiometric detection of CIP. The GMP-Tb-BDC nanoprobe was constructed by incorporating the blue-emissive ligand BDC into the Tb/GMP coordination polymers. Upon the addition of CIP, the fluorescence of terbium ion (Tb3+ ) was significantly enhanced due to the coordination and fluorescence sensitization properties of CIP, while the emission of the BDC ligand remained unchanged. The nanoprobe demonstrated good linearity in the concentration range of 0-10 µM CIP. By leveraging mobile phone software to analyze the color signals, rapid on-site analysis of CIP was achieved. Furthermore, the nanoprobe exhibited accurate analysis of CIP in actual drug and milk samples. This study showcases the potential of the GMP-Tb-BDC nanoprobe for practical applications in CIP detection.


Assuntos
Elementos da Série dos Lantanídeos , Humanos , Ciprofloxacina , Nucleotídeos , Ligantes , Térbio , Guanosina Monofosfato
4.
Langmuir ; 40(4): 2369-2376, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-38230676

RESUMO

Urinary tract infections (UTIs) have greatly affected human health in recent years. Accurate and rapid diagnosis of UTIs can enable a more effective treatment. Herein, we developed a multichannel sensor array for efficient identification of bacteria based on three antimicrobial agents (vancomycin, lysozyme, and bacitracin) functional gold nanoclusters (AuNCs). In this sensor, the fluorescence intensity of the three AuNCs was quenched to varying degrees by the bacterial species, providing a unique fingerprint for different bacteria. With this sensing platform, seven pathogenic bacteria, different concentrations of the same bacteria, and even bacterial mixtures were successfully differentiated. Furthermore, UTIs can be accurately identified with our sensors in ∼30 min with 100% classification accuracy. The proposed sensing systems offer a rapid, high-throughput, and reliable sensing platform for the diagnosis of UTIs.


Assuntos
Anti-Infecciosos , Nanopartículas Metálicas , Humanos , Ouro , Vancomicina , Bactérias , Espectrometria de Fluorescência
5.
Molecules ; 29(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38257238

RESUMO

Formaldehyde, a ubiquitous indoor air pollutant, plays a significant role in various biological processes, posing both environmental and health challenges. This comprehensive review delves into the latest advancements in electrochemical methods for detecting formaldehyde, a compound of growing concern due to its widespread use and potential health hazards. This review underscores the inherent advantages of electrochemical techniques, such as high sensitivity, selectivity, and capability for real-time analysis, making them highly effective for formaldehyde monitoring. We explore the fundamental principles, mechanisms, and diverse methodologies employed in electrochemical formaldehyde detection, highlighting the role of innovative sensing materials and electrodes. Special attention is given to recent developments in nanotechnology and sensor design, which significantly enhance the sensitivity and selectivity of these detection systems. Moreover, this review identifies current challenges and discusses future research directions. Our aim is to encourage ongoing research and innovation in this field, ultimately leading to the development of advanced, practical solutions for formaldehyde detection in various environmental and biological contexts.

6.
Talanta ; 269: 125454, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38029606

RESUMO

In this work, a lateral moving multi-pedal DNA tetrahedron machine (MTM) is designed and coupled with dual-signal output system to construct a biomimetic electrochemical ratiometric strategy for ultrasensitive target DNA analysis. The tetrahedral structure provided rigid support for the pedal, ensuring efficient replacement of the rail chain modified with ferrocene. By conjugating cholesterol molecules to one vertex of MTM, it is decorated on a lipid bilayer. This molecular architecture confers lateral movement of MTM on an electrode surface while prevents its detachment from the system. The methylene blue tagged hairpin probe provides constant power to support MTM swim on lipid bilayer. Compared with the conventional motion mode, the lateral moving mechanism has the fastest reaction rate and the highest signal-to-noise ratio. Additionally, the dual-signal reporting system further improves the accuracy of target detection on the basis of ensuring motion efficiency. The work improved movement efficiency and shortened time fragment. A linear relationship between the ratio value of two reporters and target DNA concentration was observed from 0.5 fM to 50 pM with a detection limit of 28 aM. The lateral motion mode of DNA machine coalescing with ratiometric system made this sensing platform ultrasensitive and accurate, which holds new avenue of early diagnosis.


Assuntos
Biomimética , Técnicas Biossensoriais , Bicamadas Lipídicas , Técnicas Eletroquímicas , Limite de Detecção , DNA/química
7.
Molecules ; 28(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37446874

RESUMO

Antimony (Sb) is a potential candidate anode for potassium-ion batteries (PIBs) owing to its high theoretical capacity. However; in the process of potassium alloying reaction; the huge volume expansion (about 407%) leads to pulverization of active substance as well as loss of electrical contact resulting in rapidly declining capacity. Herein; uniformly dispersed Sb-Nanodot in carbon frameworks (Sb-ND@C) were constructed by in situ confined polymerization of ionic liquids. Attributed to the uniformly dispersed Sb-ND and confinement effect of carbon frameworks; as anode for PIBs; Sb-ND@C delivered a superior rate capability (320.1 mA h g-1 at 5 A g-1) and an outstanding cycling stability (486 mA h g-1 after 1000 cycles; achieving 89.8% capacity retention). This work offers a facile route to prepare highly dispersed metal-Nanodot via the in situ polymerization of ionic liquid for high-performance metal-ion batteries.


Assuntos
Líquidos Iônicos , Polimerização , Carbono , Potássio
8.
Anal Chem ; 95(21): 8340-8347, 2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37192372

RESUMO

Biomarkers detection in blood with high accuracy is crucial for the diagnosis and treatment of many diseases. In this study, the proof-of-concept fabrication of a dual-mode sensor based on a single probe (Re-BChE) using a dual-signaling electrochemical ratiometric strategy and a "turn-on" fluorescent method is presented. The probe Re-BChE was synthesized in a single step and demonstrated dual mode response toward butyrylcholinesterase (BChE), a promising biomarker of Alzheimer's disease (AD). Due to the specific hydrolysis reaction, the probe Re-BChE demonstrated a turn-on current response for BChE at -0.28 V, followed by a turn-off current response at -0.18 V, while the fluorescence spectrum demonstrated a turn-on response with an emission wavelength of 600 nm. The developed ratiometric electrochemical sensor and fluorescence detection demonstrated high sensitivity with BChE concentrations with a low detection limit of 0.08 µg mL-1 and 0.05 µg mL-1, respectively. Importantly, the dual-mode sensor presents the following advantages: (1) dual-mode readout can correct the impact of systematic or background error, thereby achieving more accurate results; (2) the responses of dual-mode readout originate from two distinct mechanisms and relatively independent signal transduction, in which there is no interference between two signaling routes. Additionally, compared with the reported single-signal electrochemical assays for BChE, both redox potential signals were detected in the absence of biological interference within a negative potential window. Furthermore, it was discovered that the outcomes of direct dual-mode electrochemical and fluorescence quantifications of the level of BChE in serum were in agreement with those obtained from the use of commercially available assay kits for BChE sensing. This method has the potential to serve as a useful point-of-care tool for the early detection of AD.


Assuntos
Doença de Alzheimer , Butirilcolinesterase , Humanos , Doença de Alzheimer/diagnóstico , Corantes Fluorescentes , Biomarcadores
9.
Bioelectrochemistry ; 152: 108450, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37116231

RESUMO

Silver-doped hollow carbon spheres (Ag@HCS) were firstly introduced as electrochemical probes for glycated hemoglobin (HbA1c) sensing at a molecularly imprinted polymer (MIP)-based carbon cloth (CC) electrode. Herein, Ag@HCS was prepared using one-pot polymerization of resorcinol and formaldehyde with AgNO3 on the SiO2 template, subsequent carbonization, and template removal. Furthermore, poly-aminophenylboronic acid (PABA) as the MIP film was used as a sensing platform for recognition of HbA1c, which captured the Ag@HCS probe by binding of HbA1c with aptamer modified on the probe surface. Due to regular geometry, large specific surface area, superior electrical conductivity, and highly-dispersed Ag, the prepared Ag@HCS probe provided an amplified electrochemical signal based on the Ag oxidation. By use of the sandwich-type electrochemical sensor, the ultrahigh sensitivity of 4.365 µA (µg mL-1)-1 cm-2 and a wide detection range of 0.8-78.4 µg mL-1 for HbA1c detection with a low detection limit of 0.35 µg mL-1 were obtained. Excellent selectivity was obtained due to the specific binding between HbA1c and PABA-based MIP film. The fabricated electrochemical sensing platform was also implemented successfully for the determination of HbA1c concentrations in the serum of healthy individuals.


Assuntos
Carbono , Impressão Molecular , Humanos , Prata , Hemoglobinas Glicadas , Dióxido de Silício , Técnicas Eletroquímicas , Ácido 4-Aminobenzoico , Polímeros , Polímeros Molecularmente Impressos , Limite de Detecção , Eletrodos
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 296: 122692, 2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37023655

RESUMO

Hydrazine (N2H4) is a widely used raw material in the chemical industry, but at the same time hydrazine has extremely high toxicity. Therefore, the development of efficient detection methods is crucial for monitoring hydrazine in the environment and evaluating the biological toxicity of hydrazine. This study reports a near-infrared ratiometric fluorescent probe (DCPBCl2-Hz) for the detection of hydrazine by coupling a chlorine-substituted D-π-A fluorophore (DCPBCl2) to the recognition group acetyl. Due to the halogen effect of chlorine substitution, the fluorophore has an elevated fluorescence efficiency and a lowered pKa value and is suitable for physiological pH conditions. Hydrazine can specifically react with the acetyl group of the fluorescent probe to release the fluorophore DCPBCl2, so the fluorescence emission of the probe system significantly shifted from 490 nm to 660 nm. The fluorescent probe has many advantages, such as good selectivity, high sensitivity, large Stokes shift, and wide applicable pH range. The probe-loaded silica plates can realize convenient sensing gaseous hydrazine with content down to 1 ppm (mg/m3). Subsequently, DCPBCl2-Hz was successfully applied to detect hydrazine in soils. In addition, the probe can also penetrate living cells and allow the visualization of intracellular hydrazine. It can be anticipated that probe DCPBCl2-Hz will be a useful tool for sensing hydrazine in biological and environmental applications.


Assuntos
Corantes Fluorescentes , Gases , Humanos , Corantes Fluorescentes/química , Células HeLa , Espectrometria de Fluorescência , Cloro , Hidrazinas/química
11.
Chemistry ; 29(28): e202300450, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-36802106

RESUMO

Beta-site secretase (BACE1) catalyzes the cleavage of amyloid precursor protein (APP), which process ultimately lead to plaque deposition in the brain of Alzheimer's disease (AD). Thus, accurate monitor of BACE1 activity is essential to screen inhibitors for AD treatment. This study develops a sensitive electrochemical assay for probing BACE1 activity based on silver nanoparticles (AgNPs) and tyrosine conjugation as tags and a marking method, respectively. An APP segment is firstly immobilized on aminated microplate reactor. Cytosine (C) rich sequence-templated AgNPs/Zr-based metal-organic framework (MOF) composite is modified by phenol groups, and then the prepared tag (ph-AgNPs@MOF) is captured in microplate surface by the conjugation reaction of phenolic groups between tyrosine and tag. After cleavage by BACE1, the solution containing ph-AgNPs@MOF tags is transferred to the screen-printed graphene electrode (SPGE) surface for voltammetric detection of AgNP signal. This sensitive detection for BACE1 provided an excellent linear relationship between 1 to 200 pM with a detection limit of 0.8 pM. Furthermore, this electrochemical assay is successfully applied for screening of BACE1 inhibitors. This strategy is also verified to be used for evaluation of BACE1 in serum samples.


Assuntos
Doença de Alzheimer , Nanopartículas Metálicas , Estruturas Metalorgânicas , Humanos , Secretases da Proteína Precursora do Amiloide/metabolismo , Peptídeos beta-Amiloides/metabolismo , Ácido Aspártico Endopeptidases , Prata , Tirosina , Doença de Alzheimer/metabolismo , Precursor de Proteína beta-Amiloide/metabolismo
12.
Sens Actuators B Chem ; 378: 133121, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36514318

RESUMO

Alkaline phosphatase (ALP)-induced in situ fluorescent immunosensor is less investigated and reported. Herein, a high-performance ALP-labeled in situ fluorescent immunoassay platform was constructed. The developed platform was based on a fluorogenic self-assembly reaction between pyridineboronic acid (PyB(OH)2) and alizarin red S (ARS). We first used density functional theory (DFT) to theoretically calculate the changes of Gibbs free energy of the used chemicals before and after the combination and simulated the electrostatic potential on its' surfaces. The free ARS and PyB(OH)2 exist alone, neither emits no fluorescence. However, the ARS/PyB(OH)2 complex emits strong fluorescence, which could be effectively quenched by PPi based on the stronger affinity between PPi and PyB(OH)2 than that of ARS and PyB(OH)2. PyB(OH)2 coordinated with ARS again in the presence of ALP due to the ALP-catalyzed hydrolysis of PPi, and correspondingly, the fluorescence was restored. We chose cTnI and SARS-CoV-2 N protein as the model antigen to construct ALP-induced immunosensor, which exhibited a wide dynamic range of 0-175 ng/mL for cTnI and SARS-CoV-2 N protein with a low limit of detection (LOD) of 0.03 ng/mL and 0.17 ng/mL, respectively. Moreover, the proposed immunosensor was used to evaluate cTnI and SARS-CoV-2 N protein level in serum with satisfactory results. Consequently, the method laid the foundation for developing novel fluorescence-based ALP-labeled ELISA technologies in the early diagnosis of diseases.

13.
Front Oncol ; 13: 1239451, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38205138

RESUMO

Background: The emergence of immune checkpoint inhibitors (ICIs) has brought about a paradigm shift in the treatment landscape of non-small cell lung cancer (NSCLC). Despite the promising long-term survival outcomes and optimization of pathological complete response (cPR) demonstrated by various studies such as Impower010 and Checkmate-816, the effectiveness of neoadjuvant immunotherapy in advanced resectable NSCLC remains a subject of debate. Although previous research has explored the connection between the efficacy of neoadjuvant therapy and surgical-related safety, limited studies have specifically investigated the surgical-related safety of neoadjuvant immunotherapy. Therefore, our study aims to assess the efficacy and surgical-related safety of neoadjuvant immunotherapy in advanced resectable non-small cell lung cancer. Method: We conducted a retrospective study on a cohort of 93 patients with stage IIIA-IIIC NSCLC who underwent neoadjuvant therapy and surgical resection. Among them, 53 patients received neoadjuvant immunotherapy, 18 patients underwent neoadjuvant chemotherapy while the remaining 22 underwent neoadjuvant targeted therapy. The patients were separated into further groups according to their pathological type. Data analyses were performed using Mann-Whitney U test, chi-square test. Results: All patients were categorized into six distinct groups. Notably, the neoadjuvant immunotherapy squamous carcinoma group exhibited a favorable edge over the neoadjuvant targeted squamous carcinoma group concerning the duration of drainage tube indwelling and the extent of lymph node dissection. Furthermore, the neoadjuvant immunotherapy adenocarcinoma group outperformed neoadjuvant targeted therapy adenocarcinoma counterpart in terms of achieving complete pathological response (cPR). Simultaneously, the neoadjuvant immunotherapy adenocarcinoma group surpassed the neoadjuvant chemotherapy adenocarcinoma group in the incidence of hydrothorax. Nevertheless, no statistically significant disparities were noted between the neoadjuvant immunotherapy squamous carcinoma group and the neoadjuvant chemotherapy carcinoma group. Conclusion: Regarding surgical outcomes, neoadjuvant immunotherapy conferred notable advantages compared to conventional neoadjuvant chemotherapy and neoadjuvant targeted therapy for patients diagnosed with adenocarcinoma. In the case of squamous carcinoma, neoadjuvant immunotherapy exhibited superiority over neoadjuvant targeted therapy, although additional evidence is required to conclusively establish its precedence over neoadjuvant chemotherapy.

14.
Mikrochim Acta ; 190(1): 12, 2022 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-36478524

RESUMO

R-CDAs have been synthesized in a one-pot solvothermal procedure starting from 3,4-diaminobenzoic acid in an acidic medium. Transmission electron microscopy (TEM) revealed that R-CDAs nanoparticles exhibited a much larger diameter of 7.2-28.8 nm than traditional monodisperse carbon dots. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FT-IR) revealed the presence of polar functional groups (hydroxyl, amino, carboxyl) on the surface of R-CDAs. Upon excitation with visible light (550 nm), R-CDAs emit stable, red fluorescence with a maximum at 610 nm. Under the optimum conditions, Cu2+ ions quench the fluorescence of this probe, and the signal is linear in a concentration range of copper ions between 5 and 600 nM with the detection limit of only 0.4 nM. Recoveries from 98.0 to 105.0% and relative standard deviations (RSD) from 2.8 to 4.5% have been obtained for detection of Cu2+ in real water samples. Furthermore, the R-CDAs fluorescent probe showed negligible cytotoxicity toward HeLa cells and good bioimaging ability, suggesting its potential applicability as a diagnostic tool in biomedicine.


Assuntos
Carbono , Corantes Fluorescentes , Humanos , Corantes Fluorescentes/toxicidade , Carbono/toxicidade , Células HeLa , Espectroscopia de Infravermelho com Transformada de Fourier
15.
Crit Rev Anal Chem ; : 1-13, 2022 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36227582

RESUMO

Alzheimer's disease (AD) is a degenerative disease of the central nervous system. The pathogenesis is still not fully clear. One of the main histopathological manifestations is senile plaques formed by ß-amyloid (Aß) accumulation. Aß is generated from the sequential proteolysis of amyloid precursor protein (APP) by ß-secretase [i.e. ß-site APP cleaving enzyme 1 (BACE1)] and γ-secretase, with a rate-limiting step controlled by BACE1 activity. Therefore, inhibiting BACE1 activity has become a potential therapeutic strategy for AD. The development of reliable detection methods for BACE1 activity plays an important role in early diagnosis of AD and evaluation of the therapeutic effect of new drugs for AD. This article has reviewed the recent advances in BACE1 activity detection techniques. The challenges of applying these analysis techniques to early clinical diagnosis of AD and development trends of the detection techniques have been prospected.

16.
Anal Chem ; 94(34): 11940-11948, 2022 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-35981232

RESUMO

Zinc, which is the second most abundant trace element in the human central nervous system, is closely associated with Alzheimer's disease (AD). However, attempts to develop highly sensitive and selective sensing systems for Zn2+ in the brain have not been successful. Here, we used a one-step solvothermal method to design and prepare a metal-organic framework (MOF) containing the dual ligands, terephthalic acid (H2BDC) and 2,2':6',2″-terpyridine (TPY), with Eu3+ as a metal node. This MOF is denoted as Eu-MOF/BDC-TPY. Adjustment of the size and morphology of Eu-MOF/BDC-TPY allowed the dual ligands to produce multiple luminescence peaks, which could be interpreted via ratiometric fluorescence to detect Zn2+ using the ratio of Eu3+-based emission, as the internal reference, and ligand-based emission, as the indicator. Thus, Eu-MOF/BDC-TPY not only displayed higher selectivity than other metal cations but also offered a highly accurate, sensitive, wide linear, color change-based technique for detecting Zn2+ at concentrations ranging from 1 nM to 2 µM, with a low limit of detection (0.08 nM). Moreover, Eu-MOF/BDC-TPY maintained structural stability and displayed a fluorescence intensity of at least 95.4% following storage in water for 6 months. More importantly, Eu-MOF/BDC-TPY sensed the presence of Zn2+ markedly rapidly (within 5 s), which was very useful in practical application. Furthermore, the results of our ratiometric luminescent method-based analysis of Zn2+ in AD mouse brains were consistent with those obtained using inductively coupled plasma mass spectrometry.


Assuntos
Doença de Alzheimer , Elementos da Série dos Lantanídeos , Estruturas Metalorgânicas , Doença de Alzheimer/diagnóstico , Animais , Európio/química , Humanos , Ligantes , Luminescência , Estruturas Metalorgânicas/química , Camundongos , Microdiálise , Zinco
17.
Anal Chem ; 94(30): 10730-10736, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35853147

RESUMO

This study developed a novel luminescent assay for kinase activity using metal-organic coordination polymer nanoparticles (Tb/ATP-Zn) as the probe. Tb/ATP-Zn, self-assembled by adenosine triphosphate (ATP), Zn2+, and Tb3+, is non-luminescent. Protein kinase A (PKA) can catalyze the transformation of ATP within Tb/ATP-Zn nanoparticles to adenosine diphosphate (ADP), which in turn effectively sensitizes the luminescence of Tb3+. Based on this mechanism, Tb/ATP-Zn can realize the facile luminescent "turn-on" sensing of protein kinase activity without the use of external ATP and substrate peptide. Under optimized conditions, the fluorescence intensities of Tb/ATP-Zn at 550 nm are linear with the PKA activity within a range of 0.3-1.5 U·µL-1. The LOD (S/N = 3) of this method is down to 0.001 U·µL-1. The presented assay also features high selectivity, long-term stability, fast response, and convenient operation. Furthermore, Tb/ATP-Zn was successfully employed for monitoring PKA activity in cell lysis solutions. Probe Tb/ATP-Zn is thus expectable to be a powerful tool for the practical study of PKA in relevant biological events.


Assuntos
Elementos da Série dos Lantanídeos , Nanopartículas Metálicas , Trifosfato de Adenosina , Luminescência , Medições Luminescentes/métodos , Polímeros , Proteínas Quinases
18.
Mikrochim Acta ; 189(7): 263, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35776229

RESUMO

As a vital gaseous signal molecule involved in various physiological and pathological processes, nitric oxide (NO) has attracted extensive attention in the last few decades. In this work, a copper and cobalt element-doped, biphenyl-(3, 4', 5)-tricarboxylic acid (H3PTC)-synthesized metal organic framework (CuCo-PTC MOF) composite with catalytic ability was synthesized by solvothermal method. The material can catalyse the oxidation of o-phenylenediamine (OPD) groups by hydrogen peroxide (H2O2) to form fluorophores (OPDox) with yellow fluorescence emission and greatly improves its reaction rate. In the presence of NO, OPD will react with NO to produce N-(2-hydrazinophenyl) methylamine, and the group will not react with H2O2. Therefore, the concentration of NO can be measured indirectly by comparing the changes of fluorescence intensity in the presence and absence of NO. As the concentration of NO changes, the change of solution colour (from bright yellow to colourless) can also be observed under a 365-nm UV lamp. Furthermore, the method represents high selectivity for NO and shows a fast (within 5 min) and specific fluorescence response toward NO with a linear range from 0.25 to 2.0 µM; the strategy has a limit of detection (LOD) of  0.15 µM. More importantly, the probe was successfully used to detect NO in cell lysate. The recovery was between 98.5 and 103.6%, and the relative standard deviation was between 0.4 and 1.8%. The endogenous NO in cells was successfully detected under the stimulation of L-arginine, which proved the possibility of the probe in real-time and rapid sensing in actual samples and cells. The results indicate that this sensing strategy has the potential to detect NO in the internal environment. Schematic of fluorescence detection of NO.


Assuntos
Estruturas Metalorgânicas , Catálise , Peróxido de Hidrogênio , Limite de Detecção , Óxido Nítrico
19.
Biosens Bioelectron ; 210: 114301, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35500308

RESUMO

Rapid, simple, accurate and highly sensitive detection of enzymes is essential for early screening and clinical diagnosis of many diseases. In this study, we report the fabrication of a turn-on ratiometric electrochemical sensor for the in situ determination of ß-Galactosidase (ß-Gal) based on surface engineering and the design of a molecular probe (Pygal) specific for ß-Gal recognition. First, Pygal probe was synthesized and characterized, and then co-assembled with the methylene blue (MB) internal reference probe on the surface of single-wall carbon nanotubes (SWCNT)-modified carbon fiber microelectrode (CFME). The resulting CFME/SWCNT/MB + Pygal sensor is activated in the presence of ß-Gal giving one peak at 0.33 V originating from the oxidation of the product of Pygal enzymatic hydrolysis (PyOH). Another oxidation peak attributed to MB appears simultaneously at -0.28 V allowing the construction of a ratiometric electrochemical sensor for ß-Gal detection with improved sensitivity and accuracy. The sensor showed a linear response to ß-Gal in a wide concentration range from 1.5 to 30 U L-1 and a low detection limit of 0.1 U L-1. Moreover, the sensor demonstrated excellent selectivity against several biologically relevant hydrolases and redox-active molecules. Finally, the combination of excellent electrochemical performance and favorable physicochemical properties of CFME allowed the determination of ß-Gal in the whole blood of Parkinson's Disease (PD) model mice. The workflow reported in this study provides a strategy for the design and development of sensors for the in vivo monitoring of other enzymes important for the early diagnosis of different health issues.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Doença de Parkinson , Animais , Técnicas Biossensoriais/métodos , Fibra de Carbono , Técnicas Eletroquímicas/métodos , Limite de Detecção , Azul de Metileno/química , Camundongos , Doença de Parkinson/diagnóstico , beta-Galactosidase
20.
ACS Sens ; 7(2): 415-422, 2022 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-35156812

RESUMO

Small-molecule photosensitizers have great application prospects in photoelectrochemical (PEC) sensing due to their defined composition, diversified structure, and adjustable photophysical properties. Herein, we propose a new strategy for PEC analysis based on the target-induced in situ formation of the organic photosensitizer. Taking thiophenol (PhSH) as a model analyte, we designed and synthesized a 2,4-dinitrophenyl (DNP)-caged coumarin precursor (Dye-PhSH), which was then covalently coupled onto the TiO2 nanoarray substrate to obtain the working photoanode. Due to the intramolecular photoinduced electron transfer process, Dye-PhSH has only a very weak photoelectric response. Upon reacting with the target, Dye-PhSH undergoes a tandem reaction of the detachment of the DNP moiety and the intramolecular cyclization process, which leads to a coumarin dye with a pronounced photoelectric effect, thus achieving a highly selective turn-on PEC response to PhSH. For the first time, this study was to construct a PEC sensor by exploiting specific organic reactions for the in situ generation of small molecule-based photoactive material. It can be anticipated that the proposed strategy will expand the paradigm of PEC sensing and holds great potential for detecting various other analytes.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Fármacos Fotossensibilizantes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA