Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Jpn J Appl Phys (2008) ; 63(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38911013

RESUMO

The double-Nakagami (DN) model provides a method for analyzing the amplitude envelope statistics of quantitative ultrasound (QUS). In this study, the relationship between the sound field characteristics and the robustness of QUS evaluation was evaluated using five HF linear array probes and tissue-mimicking phantoms. Compound plane-wave imaging (CPWI) was used to acquire echo data. Five phantoms containing two types of scatterers were used to mimic fatty liver tissue. After clarifying the relationship between the sound field characteristics of the probes and QUS parameters, DN QUS parameters in 10 rat livers with different lipidification were evaluated using one HF linear array probe. For both phantom and in situ liver analyses, correlations between fat content and multiple QUS parameters were confirmed, suggesting that the combination of CPWI using a HF linear array probe with the DN model is a robust method for quantifying fatty liver and has potential clinical diagnostic applications.

2.
Acta Neurochir (Wien) ; 166(1): 272, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888676

RESUMO

BACKGROUND: Acute subdural hematoma (ASDH) is a life-threatening condition, and hematoma removal is necessary as a lifesaving procedure when the intracranial pressure is highly elevated. However, whether decompressive craniectomy (DC) or conventional craniotomy (CC) is adequate remains unclear. Hinge craniotomy (HC) is a technique that provides expansion potential for decompression while retaining the bone flap. At our institution, HC is the first-line operation instead of DC for traumatic ASDH, and we present the surgical outcomes. METHODS: From January 1, 2017, to December 31, 2022, 372 patients with traumatic ASDH were admitted to our institution, among whom 48 underwent hematoma evacuation during the acute phase. HC was performed in cases where brain swelling was observed intraoperatively. If brain swelling was not observed, CC was selected. DC was performed only when the brain was too swollen to allow replacement of the bone flap. We conducted a retrospective analysis of patient demographics, prognosis, and subsequent cranial procedures for each technique. RESULTS: Of the 48 patients, 2 underwent DC, 23 underwent HC, and 23 underwent CC. The overall mortality rate was 20.8% (10/48) at discharge and 30.0% (12/40) at 6 months. The in-hospital mortality rates for DC, HC, and CC were 100% (2/2), 21.7% (5/23), and 13.0% (3/23), respectively. Primary brain injury was the cause of death in five patients whose brainstem function was lost immediately after surgery. No fatalities were attributed to the progression of postoperative brain herniation. In only one case, the cerebral contusion worsened after the initial surgery, leading to brain herniation and necessitating secondary DC. CONCLUSIONS: The strategy of performing HC as the first-line operation for ASDH did not increase the mortality rate compared with past surgical reports and required secondary DC in only one case.


Assuntos
Craniotomia , Craniectomia Descompressiva , Hematoma Subdural Agudo , Humanos , Hematoma Subdural Agudo/cirurgia , Masculino , Craniectomia Descompressiva/métodos , Feminino , Pessoa de Meia-Idade , Craniotomia/métodos , Idoso , Estudos Retrospectivos , Adulto , Resultado do Tratamento , Idoso de 80 Anos ou mais
4.
Artigo em Inglês | MEDLINE | ID: mdl-38261486

RESUMO

We propose burst-wave-aided, contrast-enhanced, active Doppler ultrasonography for visualizing lymph vessels. This technique forces ultrasound contrast agents (UCAs) to move using the acoustic radiation force induced by burst waves with low amplitude while suppressing their destruction. Using a flow phantom, we measured the average, decrease rate of echo intensity [i.e., pulse intensity integral (PII)], and the velocity of individual contrast agents, which directly affects the performance of imaging and tracking contrast agents under stationary flow conditions. Comparison with pulse-inversion Doppler without exposure to the burst wave demonstrated that the velocity of the contrast agents could be enhanced up to several tens of millimeters per second by the effect of the burst wave, maximizing the echo intensity extracted by a clutter filter. The contrast ratio (CR), defined as the ratio of the contrast echo to the phantom echo outside the channel, did not change appreciably, even when the lower cut-off velocity of the clutter filter was increased up to 10 mm/s. This implies a better robustness against the motion of the tissue. In addition, the performance for detecting contrast agents (i.e., echo intensity) was superior or similar to that of pulse-inversion Doppler, even in undesirable conditions where the flow had a velocity component in the opposite direction to that of the acoustic radiation force. The echo intensity was lower or the same as that in pulse-inversion Doppler, demonstrating the potential for suppressing the destruction of contrast agents and enabling long-term observations. From these results, we expect that the proposed method will be beneficial for visualizing lymph vessels.


Assuntos
Meios de Contraste , Microbolhas , Ultrassonografia , Ultrassonografia Doppler/métodos , Angiografia , Imagens de Fantasmas , Velocidade do Fluxo Sanguíneo
5.
Ultrasound Med Biol ; 50(4): 592-599, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38238201

RESUMO

OBJECTIVE: Hepatic fibrosis has recently been evaluated using ultrasonography or magnetic resonance elastography. Although the shear wave velocity (SWV) obtained using point shear wave elastography (pSWE) provides a valuable measure of fibrosis, underlying steatosis may affect its measurement. METHODS: Using hepatic fibrosis samples, this study evaluated the effect of steatosis on the shear wave velocity of pSWE (Vs) and viscoelastic properties (assessed by dynamic mechanical analysis) of rat liver. Fifty rats with various grades of steatosis and fibrosis underwent open abdominal in vivo Vs measurements using a commercial ultrasound scanner. The mechanical properties of hepatic tissue were also characterized under ex vivo conditions using dynamic mechanical analysis and the Zener model of viscoelasticity. RESULTS: Fibrosis and steatosis progression influenced Vs and elasticity. The SWV computed using the Zener model and Vs showed a substantial correlation (r > 0.8). Fibrosis progression increased SWV. Steatosis was also related to SWV. Steatosis progression obscured the SWV change associated with fibrosis progression. CONCLUSION: We conclude that steatosis progression affects the evaluation of fibrosis progression. This finding could aid discrimination of non-alcoholic steatohepatitis from non-alcoholic fatty liver disease using SWV.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Ratos , Animais , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/complicações , Fibrose
6.
J Med Ultrason (2001) ; 51(1): 5-16, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37796397

RESUMO

PURPOSE: Quantitative diagnosis of the degree of fibrosis progression is currently a focus of attention for fatty liver in nonalcoholic steatohepatitis (NASH). However, previous studies have focused on either lipid droplets or fibrotic tissue, and few have reported the evaluation of both in patients whose livers contain adipose and fibrous features. Our aim was to evaluate fibrosis tissue and lipid droplets in the liver. METHODS: We used an analytical method combining the multi-Rayleigh (MRA) model and a healthy liver structure filter (HLSF) as a technique for statistical analysis of the amplitude envelope to estimate fat and fibrotic volumes in clinical datasets with different degrees of fat and fibrosis progression. RESULTS: Fat mass was estimated based on the non-MRA fraction corresponding to the signal characteristics of aggregated lipid droplets. Non-MRA fraction has a positive correlation with fat mass and is effective for detecting moderate and severe fatty livers. Progression of fibrosis was estimated using MRA parameters in combination with the HLSF. The proposed method was used to extract non-healthy areas with characteristics of fibrotic tissue. Fibrosis in early fatty liver suggested the possibility of evaluation. On the other hand, fat was identified as a factor that reduced the accuracy of estimating fibrosis progression in moderate and severe fatty livers. CONCLUSION: The proposed method was used to simultaneously evaluate fat mass and fibrosis progression in early fatty liver, suggesting the possibility of quantitative evaluation for discriminating between lipid droplets and fibrous tissue in the early fatty liver.


Assuntos
Fígado , Hepatopatia Gordurosa não Alcoólica , Humanos , Progressão da Doença , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Ultrassonografia
7.
Ultrasonics ; 134: 107102, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37454454

RESUMO

Detection of tumors and regional lymph nodes during surgery has been proposed in the diagnosis of lymphatic metastasis and the surgical treatment of malignant diseases. Giant cluster vesicles (GCVs), including liposomally formulated indocyanine green (LP-ICG) derivatives, are a possible candidate for agents to realize the two contradictory properties, i.e., retention in tissue for lesion-marking and trace for sentinel lymph nodes (SLNs) identification. We attempted to release the LP-ICG derivatives from GCVs using ultrasound contrast agents (UCAs) under ultrasound irradiation. An absorption spectrophotometer quantitatively evaluated the amounts of released LP-ICG derivatives. As a result, we demonstrated that it depended on conditions for sound pressure, burst length, and number density of UCAs, and had a sound pressure threshold independent of burst length and number density of UCAs. The results will aid to determine appropriate conditions to maximize the released amount of LP-ICG derivatives while keeping safety.


Assuntos
Corantes Fluorescentes , Verde de Indocianina , Humanos , Verde de Indocianina/química , Metástase Linfática , Ultrassonografia , Meios de Contraste
8.
J Med Ultrason (2001) ; 50(2): 119, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37171736
9.
Sensors (Basel) ; 23(5)2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36904843

RESUMO

High-frame-rate imaging with a clutter filter can clearly visualize blood flow signals and provide more efficient discrimination with tissue signals. In vitro studies using clutter-less phantom and high-frequency ultrasound suggested a possibility of evaluating the red blood cell (RBC) aggregation by analyzing the frequency dependence of the backscatter coefficient (BSC). However, in in vivo applications, clutter filtering is required to visualize echoes from the RBC. This study initially evaluated the effect of the clutter filter for ultrasonic BSC analysis for in vitro and preliminary in vivo data to characterize hemorheology. Coherently compounded plane wave imaging at a frame rate of 2 kHz was carried out in high-frame-rate imaging. Two samples of RBCs suspended by saline and autologous plasma for in vitro data were circulated in two types of flow phantoms without or with clutter signals. The singular value decomposition was applied to suppress the clutter signal in the flow phantom. The BSC was calculated using the reference phantom method, and it was parametrized by spectral slope and mid-band fit (MBF) between 4-12 MHz. The velocity distribution was estimated by the block matching method, and the shear rate was estimated by the least squares approximation of the slope near the wall. Consequently, the spectral slope of the saline sample was always around four (Rayleigh scattering), independently of the shear rate, because the RBCs did not aggregate in the solution. Conversely, the spectral slope of the plasma sample was lower than four at low shear rates but approached four by increasing the shear rate, because the aggregations were presumably dissolved by the high shear rate. Moreover, the MBF of the plasma sample decreased from -36 to -49 dB in both flow phantoms with increasing shear rates, from approximately 10 to 100 s-1. The variation in the spectral slope and MBF in the saline sample was comparable to the results of in vivo cases in healthy human jugular veins when the tissue and blood flow signals could be separated.


Assuntos
Eritrócitos , Ultrassom , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Ultrassonografia , Imagens de Fantasmas
10.
J Neurosurg ; 138(1): 191-198, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35594890

RESUMO

OBJECTIVE: Subarachnoid hemorrhage (SAH) due to intracranial aneurysm (IA) rupture is often a devastating event. Since the incidence of SAH increases especially in menopause, it is crucial to clarify the detailed pathogenesis of these events. The activation of vascular nucleotide-binding oligomerization domain-like receptor family pyrin domain-containing 3 (NLRP3) inflammasomes has been studied in ischemic stroke and cardiovascular disease. However, the role of NLRP3 in IA rupture still needs to be explained. The authors sought to test their hypothesis that, under estrogen-deficient conditions, activation of NLRP3 inflammasomes via downregulation of the estrogen receptor (ER) facilitates IA rupture. METHODS: Ten-week-old female Sprague Dawley rats with and without oophorectomy were subjected to hemodynamic changes and hypertension (OVX+/HT and OVX-/HT, respectively) and fed a high-salt diet. Separately, using human brain endothelial cells (HBECs) and human brain smooth muscle cells (HBSMCs), the authors tested the effect of NLRP3 under estrogen-free conditions and in the presence of estradiol or of ER agonists. RESULTS: In OVX+/HT rats, the frequency of IA rupture was significantly higher than in OVX-/HT rats (p = 0.03). In the left posterior cerebral artery prone to rupture in OVX+/HT rats, the levels of the mRNAs encoding ERα and Sirt1, but not of that encoding ERß, were decreased, and the levels of the mRNAs encoding NLRP3, interleukin-1ß (IL-1ß), and matrix metalloproteinase 9 (MMP-9) were elevated. Immunohistochemical analysis demonstrated that the expression profiles of these proteins correlated with their mRNA levels. Treatment with an ER modulator, bazedoxifene, normalized the expression profiles of these proteins and improved SAH-free survival. In HBECs and HBSMCs under estrogen-free conditions, the depletion of ERα and Sirt1 and the accumulation of NLRP3 were counteracted by exposure to estradiol or to an ERα agonist but not to an ERß agonist. CONCLUSIONS: To the authors' knowledge, this work represents the first demonstration that, in an aneurysm model under estrogen-deficient conditions, the depletion of ERα and Sirt1 may contribute to activation of the NLRP3/IL-1ß/MMP-9 pathway, facilitating the rupture of IAs in the estrogen-deficient rat IA rupture model.


Assuntos
Aneurisma Intracraniano , Hemorragia Subaracnóidea , Ratos , Feminino , Humanos , Animais , Inflamassomos/metabolismo , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Receptor alfa de Estrogênio/genética , Receptor alfa de Estrogênio/metabolismo , Receptores de Estrogênio , Ratos Sprague-Dawley , Metaloproteinase 9 da Matriz , Receptor beta de Estrogênio/genética , Receptor beta de Estrogênio/metabolismo , Sirtuína 1 , Interleucina-1beta , Células Endoteliais/metabolismo , Estrogênios , Estradiol
11.
J Clin Transl Hepatol ; 11(1): 244-252, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36406314

RESUMO

Percutaneous ablation under imaging guidance is a curative treatment that can induce complete tumor necrosis with advantages of minimal invasiveness and a low risk of complications. Thermal ablation, which includes radiofrequency ablation and microwave ablation, is a representative technique that has sufficient antitumor effects in cases of hepatocellular carcinoma with ≤3 lesions measuring ≤3 cm and preserved liver function. The short- and long-term outcomes of patients are comparable with those achieved with surgical resection. Despite their nonmalignant nature, some benign liver tumors require treatment for symptoms caused by the presence of the tumor and/or continuous enlargement. Ablation may be the treatment of choice because it has lower burden on patients than surgical treatment. This review describes the recent concepts, progress, and limitations of ablation-based treatment for benign liver tumors.

12.
J Med Ultrason (2001) ; 49(4): 569-578, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36098894

RESUMO

PURPOSE: The aim of this study was to elucidate the frequency dependence of the speed of sound (SoS) and attenuation coefficients in phantoms with controlled attenuation properties (scatterer density, scatterer size, absorption control material) and rat livers. METHODS: The frequency dependence of SoS and attenuation coefficients were evaluated with ultrasound (1-15 MHz) by observing multiple phantoms with different scatterer sizes, densities, and presence or absence of evaporated milk as absorbing media. Normal and fatty model rat livers were examined with the same protocol. RESULTS: The phantom results revealed that the scatterer density and SoS of the base media were the dominant factors causing the changes in SoS. Frequency dependence was not observed in SoS. Assessment of the attenuation coefficient showed that the frequency dependence was mainly affected by absorption attenuation when the scatterer was as small as a hepatocyte (i.e. ≤ 10 µm). Scattering attenuation was also observed to affect frequency dependence when the scatterer was as large as lipid droplets (i.e. ≤ 40 µm). CONCLUSION: Assuming a consistent size of the main scatterers in the evaluation medium, the frequency dependence of the SoS and attenuation coefficients may provide insight into the scatterer density and the contribution of absorption and scattering attenuation. Further studies in the higher frequency band (up to about 50 MHz) are expected to advance the clinical application of high-frequency ultrasound.


Assuntos
Acústica , Som , Ratos , Animais , Imagens de Fantasmas , Ultrassonografia/métodos
13.
Surg Neurol Int ; 13: 340, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36128114

RESUMO

Background: Convexity dural arteriovenous fistulae (dAVF) usually reflux into cortical veins without involving the venous sinuses. Although direct drainage ligation is curative, transarterial embolization (TAE) may be an alternative treatment. Case Description: Between September 2018 and January 2021, we encountered four patients with convexity dAVFs. They were three males and one female; their age ranged from 36 to 73 years. The initial symptom was headache (n = 1) or seizure (n = 2); one patient was asymptomatic. In all patients, the feeders were external carotid arteries with drainage into the cortical veins; in two patients, there was pial arterial supply from the middle cerebral artery. All patients were successfully treated by TAE alone using either Onyx or N-butyl cyanoacrylate embolization. Two patients required two sessions. All dAVFs were completely occluded and follow-up MRI or angiograms confirmed no recurrence. Conclusion: Our small series suggests that TAE with a liquid embolic material is an appropriate first-line treatment in patients with convexity dAVFs with or without pial arterial supply.

14.
J Neuroinflammation ; 19(1): 161, 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35725479

RESUMO

BACKGROUND AND PURPOSE: An aneurysmal subarachnoid hemorrhage is a devastating event. To establish an effective therapeutic strategy, its pathogenesis must be clarified, particularly the pathophysiology of brain harboring intracranial aneurysms (IAs). To elucidate the pathology in brain harboring IAs, we examined the significance of the receptor for advanced glycation end-products (RAGE)/mineralocorticoid receptor (MR) pathway and Na+/K+-ATPase (ATP1α3). METHODS: Ten-week-old female rats were subjected to oophorectomy as well as hypertension and hemodynamic changes to induce IAs, and were fed a high-salt diet. Brain damage in these rats was assessed by inflammatory changes in comparison to sham-operated rats fed a standard diet. RESULTS: Six weeks after IA induction (n = 30), irregular morphological changes, i.e., an enlarged vessel diameter and vascular wall, were observed in all of the left posterior cerebral arteries (Lt PCAs) prone to rupture. Approximately 20% of rats had ruptured IAs within 6 weeks. In brain harboring unruptured IAs at the PCA, the mRNA levels of RAGE and MR were higher, and that of ATP1α3 was lower than those in the sham-operated rats (p < 0.05, each). Immunohistochemically, elevated expression of RAGE and MR, and decreased expression of ATP1α3 were observed in the brain parenchyma adjacent to the Lt PCA, resulting in increased Iba-1 and S100B expression that reflected the inflammatory changes. There was no difference between the unruptured and ruptured aneurysm rat groups. Treatment with the MR antagonist esaxerenone abrogated these changes, and led to cerebral and vascular normalization and prolonged subarachnoid hemorrhage-free survival (p < 0.05). CONCLUSIONS: Regulation of the imbalance between the RAGE/MR pathway and ATP1α3 may help attenuate the damage in brain harboring IAs, and further studies are warranted to clarify the significance of the down-regulation of the MR/RAGE pathway and the up-regulation of ATP1α3 for attenuating the pathological changes in brain harboring IAs.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Aneurisma Roto/patologia , Animais , Encéfalo/metabolismo , Feminino , Proteína HMGB1/metabolismo , Aneurisma Intracraniano/patologia , Ratos , Receptor para Produtos Finais de Glicação Avançada/metabolismo , Receptores de Mineralocorticoides/metabolismo , ATPase Trocadora de Sódio-Potássio/metabolismo , Hemorragia Subaracnóidea/patologia
15.
Gan To Kagaku Ryoho ; 49(4): 473-477, 2022 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-35444140

RESUMO

A 60-year-old woman was not accompanied by any symptom. She had a gallstone which was identified 20 years prior. Ultrasonography performed by a local doctor revealed that the gallbladder was filled with small stones, and the patient was referred to our department for further examination and treatment for gallbladder stone. Tumor markers are elevated. Contrast- enhanced CT revealed gallbladder stones and thickening in the gallbladder body. PET-CT showed abnormal accumulation of FDG-PET with SUVmax 3.6 in the body of the gallbladder. With a diagnosis of gallbladder cancer, extended cholecystectomy and gallbladder bed resection with regional lymph node dissection were performed. The tumor was diagnosed histologically as small cell type neuroendocrine carcinoma of the gallbladder(pT2a[SS], pN0, pStage ⅡA; Japanese society of hepato-biliary-pancreatic surgery, the 7th edition). The postoperative course was uneventful. This patient has been followed up for 8 years without obvious signs of recurrence. R0 resection and lack of lymph node metastasis can allow long- term survival.


Assuntos
Carcinoma Neuroendócrino , Carcinoma de Células Pequenas , Neoplasias da Vesícula Biliar , Carcinoma Neuroendócrino/cirurgia , Carcinoma de Células Pequenas/cirurgia , Feminino , Neoplasias da Vesícula Biliar/patologia , Neoplasias da Vesícula Biliar/cirurgia , Humanos , Excisão de Linfonodo , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico
16.
J Med Ultrason (2001) ; 49(2): 143-152, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35061118

RESUMO

PURPOSE: To quantify the bias of shear wave speed (SWS) measurements in a viscoelastic phantom across six different ultrasound (US) systems and to compare the SWS with those from transient elastography (TE) and magnetic resonance elastography (MRE). METHODS: A viscoelastic phantom of stiffness representing fibrotic liver or healthy thyroid was measured with nine (linear probe) and 10 (convex probe) modes of six different US-based shear wave elastography (SWE) systems using linear and convex probes. SWS measurements of three regions of interest were repeated thrice at two focal depths, coupling the probe to the phantom using a jig. An MRE system using three motion-encoding gradient frequencies of 60, 90, and 120 Hz and TE were also used to measure the stiffness of the phantom. RESULTS: The SWS from different SWE systems had mean coefficients of variation of 9.0-9.2% and 5.4-5.6% with linear and convex probes, respectively, in viscoelastic phantom measurement. The focal depth was a less significant source of SWS variability than the system. The total average SWS obtained with US-SWE systems was 19.9% higher than that obtained with MRE at 60 Hz, which is commonly used in clinical practice, and 31.5% higher than that obtained with TE using the M probe. CONCLUSIONS: Despite the measurement biases associated with the SWE systems, biases were not necessarily consistent, and they changed with the probes used and depth measured. The SWS of the viscoelastic phantom obtained using different modalities increased according to the shear wave frequency used.


Assuntos
Técnicas de Imagem por Elasticidade , Viés , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática , Imagens de Fantasmas , Ultrassonografia
17.
Ultrasound Med Biol ; 48(4): 646-662, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35033402

RESUMO

This study investigated the ability of in vivo quantitative ultrasound (QUS) assessment to evaluate lymphedema severity compared with the gold standard method, the International Society of Lymphology (ISL) stage. Ultrasonic measurements were made around the middle thigh (n = 150). Radiofrequency data were acquired using a clinical scanner and 8-MHz linear probe. Envelope statistical analysis was performed using constant false alarm rate processing and homodyned K (HK) distribution. The attenuation coefficient was calculated using the spectral log-difference technique. The backscatter coefficient (BSC) was obtained by the reference phantom method with attenuation compensation according to the attenuation coefficients in the dermis and hypodermis, and then effective scatterer diameter (ESD) and effective acoustic concentration (EAC) were estimated with a Gaussian model. Receiver operating characteristic curves of QUS parameters were obtained using a linear regression model. A single QUS parameter with high area under the curve (AUC) differed between the dermis (ESD and EAC) and hypodermis (HK) parameters. The combinations with ESD and EAC in the dermis, HK parameters in the hypodermis and typical features (dermal thickness and echogenic regions in the hypodermis) improved classification performance between ISL stages 0 and ≥I (AUC = 0.90 with sensitivity of 75% and specificity of 91%) in comparison with ESD and EAC in the dermis (AUC = 0.82) and HK parameters in the hypodermis (AUC = 0.82). In vivo QUS assessment by BSC and envelope statistical analyses can be valuable for non-invasively classifying an extremely early stage of lymphedema, such as ISL stage I, and following its progression.


Assuntos
Linfedema , Tela Subcutânea , Derme/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Ultrassonografia/métodos
19.
Front Med (Lausanne) ; 9: 1057045, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36590972

RESUMO

Portal hypertension is a major pathophysiological condition in patients with cirrhosis. This accounts for the occurrence and severity of the various manifestations. The degree is determined by the portal pressure or hepatic venous pressure gradients, both of which are obtained by invasive interventional radiological procedures. Ultrasound (US) is a simple and minimally invasive imaging modality for the diagnosis of liver diseases. Owing to the availability of microbubble-based contrast agents and the development of imaging modes corresponding to contrast effects, contrast-enhanced US (CEUS) has become popular worldwide for the detailed evaluation of hepatic hemodynamics, diffuse liver disease, and focal hepatic lesions. Recent advancements in digital technology have enabled contrast-based demonstrations with improved resolution, leading to a wider range of applications. This review article describes the current role, benefits, and limitations of CEUS in the management of portal hypertension.

20.
IEEE J Transl Eng Health Med ; 9: 1800612, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34786215

RESUMO

Objective: Hepatic steatosis causes nonalcoholic fatty liver disease and may progress to fibrosis. Ultrasound is the first-line approach to examining hepatic steatosis. Fatty droplets in the liver parenchyma alter ultrasound radiofrequency (RF) signal statistical properties. This study proposes using sample entropy, a measure of irregularity in time-series data determined by the dimension [Formula: see text] and tolerance [Formula: see text], for ultrasound parametric imaging of hepatic steatosis and fibrosis. Methods: Liver donors and patients were enrolled, and their hepatic fat fraction (HFF) ([Formula: see text]), steatosis grade ([Formula: see text]), and fibrosis score ([Formula: see text]) were measured to verify the results of sample entropy imaging using sliding-window processing of ultrasound RF data. Results: The sample entropy calculated using [Formula: see text] 4 and [Formula: see text] was highly correlated with the HFF when a small window with a side length of one pulse was used. The areas under the receiver operating characteristic curve for detecting hepatic steatosis that was [Formula: see text]mild, [Formula: see text]moderate, and [Formula: see text]severe were 0.86, 0.90, and 0.88, respectively, and the area was 0.87 for detecting liver fibrosis in individuals with significant steatosis. Discussion/Conclusions: Ultrasound sample entropy imaging enables the identification of time-series patterns in RF signals received from the liver. The algorithmic scheme proposed in this study is compatible with general ultrasound pulse-echo systems, allowing clinical fibrosis risk evaluations of individuals with developing hepatic steatosis.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Entropia , Humanos , Cirrose Hepática/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA