Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiol ; 84(4): 266-273, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38701945

RESUMO

BACKGROUND: Multi-parametric assessment, including heart sounds in addition to conventional parameters, may enhance the efficacy of noninvasive telemonitoring for heart failure (HF). We sought to assess the feasibility of self-telemonitoring with multiple devices including a handheld heart sound recorder and its association with clinical events in patients with HF. METHODS: Ambulatory HF patients recorded their own heart sounds, mono­lead electrocardiograms, oxygen saturation, body weight, and vital signs using multiple devices every morning for six months. RESULTS: In the 77 patients enrolled (63 ±â€¯13 years old, 84 % male), daily measurements were feasible with a self-measurement rate of >70 % of days in 75 % of patients. Younger age and higher Minnesota Living with Heart Failure Questionnaire scores were independently associated with lower adherence (p = 0.002 and 0.027, respectively). A usability questionnaire showed that 87 % of patients felt self-telemonitoring was helpful, and 96 % could use the devices without routine cohabitant support. Six patients experienced ten HF events of re-hospitalization and/or unplanned hospital visits due to HF. In patients who experienced HF events, a significant increase in heart rate and diastolic blood pressure and a decrease in the time interval from Q wave onset to the second heart sound were observed 7 days before the events compared with those without HF events. CONCLUSIONS: Self-telemonitoring with multiple devices including a handheld heart sound recorder was feasible even in elderly patients with HF. This intervention may confer a sense of relief to patients and enable monitoring of physiological parameters that could be valuable in detecting the deterioration of HF.


Assuntos
Estudos de Viabilidade , Insuficiência Cardíaca , Ruídos Cardíacos , Telemedicina , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Masculino , Feminino , Pessoa de Meia-Idade , Projetos Piloto , Idoso , Telemedicina/instrumentação , Autocuidado , Frequência Cardíaca , Inquéritos e Questionários , Eletrocardiografia
2.
J Cardiol Cases ; 27(3): 108-112, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36910036

RESUMO

Chronic heart failure (HF) has various phenotypes. It is accompanied by repeated hospitalizations over a long period. Therefore, accumulating long-term observational data of patients with various backgrounds is important to establish a prediction technology for the exacerbation of HF. In a patient with chronic right-sided HF caused by cor pulmonale, heart sounds and electrocardiograms were recorded at home or our hospital twice a week for 7 months including the stable (31 days), pre-exacerbation (2 weeks just before the onset of exacerbation), and hospitalization periods and quantified as cardiac acoustic biomarkers (CABs) using AUDICOR technology (Inovise Medical, Inc., Portland, OR, USA). The relationship between the change in CABs and hospitalization events due to HF were investigated. During the pre-exacerbation period just before the onset of exacerbation of HF leading to hospitalization, inaudible changes in the third heart sound (S3) strength that were probably derived from the right heart were observed. Although the values of the fourth heart sound (S4) strength were high during the stable and pre-exacerbation period, values decreased markedly during hospitalization. These findings suggest that CABs including S3 and S4 are useful for the early detection of signs of HF exacerbation. Learning Objective: In a case of chronic right-sided heart failure, the change in the third heart sound (S3) caused by the right ventricle could be detected using cardiac acoustic biomarkers in exacerbations of heart failure. Even if S3 is inaudible by auscultation, it is possible to observe its changes using quantification technology.

3.
J Clin Med ; 11(21)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36362600

RESUMO

Since an elevation of pulmonary artery pressure (PAP) often precedes clinical worsening of heart failure (HF), early and non-invasive detection of this sign is useful in HF care. This study aimed to assess whether cardiac acoustic biomarkers (CABs) are associated with the elevation of PAP in patients with HF. Patients with HF scheduled to undergo right heart catheterization were prospectively enrolled. CABs were concurrently recorded during catheterization at rest (baseline) and while applying a handgrip (exercise). Forty-nine patients were included in the analysis, and their mean PAP significantly increased after exercise compared to baseline. Several CABs correlated significantly with mean PAP by absolute values, among which S2 Width (r = 0.354; p = 0.014 and r = 0.363; p = 0.010) and S3 Strength (r = 0.375; p = 0.009 and r = 0.386; p = 0.007) were consistent throughout baseline and exercise. The response of CABs to exercise-induced PAP elevation was divided into two patterns: increasing and decreasing. The frequency of cardiac index below 2.2 mL/m2 was significantly higher in the decreasing pattern. CABs related to S2 and S3 showed significant correlations with absolute PAP values both at baseline and after exercise in patients with HF, but no significant correlations between their changes from baseline to post-exercise were observed in this study population. Further research is therefore needed to assess whether CABs can sensitively reflect changes in PAP according to HF status and underlying phenotypes.

4.
Heart Vessels ; 37(4): 593-600, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34599380

RESUMO

Pulmonary hypertension (PH) is commonly associated with left heart disease. In this retrospective study, using the database of a clinical study conducted between January 2008 and July 2008, the phenotypes of PH were classified using non-invasive cardiac acoustic biomarkers (CABs) and compared with classification by echocardiography. Records with same-day measurement of acoustic cardiography and right heart catheterization (RHC) parameters were included; cases with congenital heart disease were excluded. Using the RHC measurements, PH was classified as pre-capillary PH (Prec-PH), isolated post-capillary PH (Ipc-PH), and combined pre-capillary and post-capillary PH (Cpc-PH). The first, second, third, and fourth heart sounds (S1, S2, S3, and S4) were quantified as CABs (intensity, complexity, and strength). Forty subjects were selected: 5 had Prec-PH, 5 had Ipc-PH, 8 had Cpc-PH, and 22 had No-PH. CABs were significantly correlated with RHC measurements, with significant differences among phenotypes. Phenotype classification was performed using various CABs, and the diagnostic performance as assessed by the area under the receiver operating characteristic curve was 0.674-0.720 for Prec-PH, 0.657-0.807 for Ipc-PH, and 0.742 for Cpc-PH. High negative and low positive predictive values for phenotype identification were observed. CABs may provide an ambulatory measurement method with home-monitoring friendliness which is more convenient than standard examinations to identify presence of PH and its phenotypes.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Acústica , Biomarcadores , Cateterismo Cardíaco , Humanos , Fenótipo , Estudos Retrospectivos
5.
ESC Heart Fail ; 8(5): 4037-4047, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34184415

RESUMO

AIMS: Relationships between cardiac acoustic biomarkers (CABs) measured by acoustic cardiography and clinical outcomes have been reported in heart failure (HF) patients. However, no studies have investigated the temporal change of CABs and the corresponding changes in HF status. The purpose of this study was to assess whether the temporal changes of CABs in patients with acute decompensated heart failure (ADHF) reflect changes in cardiac function and status. METHODS AND RESULTS: Sixty ADHF patients were enrolled prospectively. CABs and echocardiography data were collected at admission, before discharge, and at the first clinic visit. CABs included electromechanical activation time (EMAT); the time interval from Q wave onset on electrocardiography to the first heart sound (S1), QoS2; the time interval from Q wave onset on electrocardiography to the second heart sound (S2); and third heart sound (S3) and fourth heart sound (S4) intensities, defined as the peak-to-peak amplitudes of S3 and S4. EMATc (EMAT/RR) (P = 0.001), S3 intensity (P < 0.001), and S4 intensity (P < 0.001) were significantly decreased, and QoS2 (P = 0.005) was significantly increased from admission to discharge. The change in S3 intensity was significantly correlated with that of E/A (ρ = 0.571, P < 0.001), and the extended QoS2 was also significantly correlated with the increase in the stroke volume index (ρ = 0.383, P = 0.004). CONCLUSIONS: Some CABs in ADHF patients changed significantly in the normal direction throughout the treatment course and could be useful biomarkers in ADHF management.


Assuntos
Insuficiência Cardíaca , Acústica , Biomarcadores , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Humanos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA