Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
Kaohsiung J Med Sci ; 36(10): 841-849, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32729992

RESUMO

Mechanical ventilation (MV) is a common life support system in intensive care units. Accurate identification of patients who are capable of being extubated can shorten the MV duration and potentially reduce MV-related complications. Therefore, prediction of patients who can successfully be weaned from the mechanical ventilator is an important issue. The electronic medical record system (EMRs) has been applied and developed in respiratory therapy in recent years. It can increase the quality of critical care. However, there is no perfect index available that can be used to determine successful MV weaning. Our purpose was to establish a novel model that can predict successful weaning from MV. Patients' information was collected from the Kaohsiung Medical University Hospital respiratory therapy EMRs. In this retrospective study, we collected basic information, classic weaning index, and respiratory parameters during spontaneous breathing trials of patients eligible for extubation. According to the results of extubation, patients were divided into successful extubation and extubation failure groups. This retrospective cohort study included 169 patients. Statistical analysis revealed successful extubation predictors, including sex; height; oxygen saturation; Glasgow Coma Scale; Acute Physiology and Chronic Health Evaluation II score; pulmonary disease history; and the first, 30th, 60th, and 90th minute respiratory parameters. We built a predictive model based on these predictors. The area under the curve of this model was 0.889. We established a model for predicting the successful extubation. This model was novel to combine with serial weaning parameters and thus can help intensivists to make extubation decisions easily.


Assuntos
Respiração Artificial/métodos , Desmame do Respirador/métodos , Idoso , Idoso de 80 Anos ou mais , Registros Eletrônicos de Saúde , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Pulm Pharmacol Ther ; 48: 22-27, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29054517

RESUMO

BACKGROUND: Few studies have evaluated the size distribution of inhaled and exhaled aerosolized drugs, or the effect of heated humidification on particle size and lung deposition. The present study evaluated these aspects of bronchodilator (salbutamol/ipratropium) delivery using a lung model in the absence and presence of heat and humidification. METHODS: We positioned filters to collect and measure the initial drug, inhaled drug, and exhaled drug. Particle size distribution was evaluated using an 8-stage Marple personal cascade impactor with 0.2-µm polycarbonate filters. RESULTS: A greater inhaled drug mass was delivered using a vibrating mesh nebulizer (VMN) than by using a small volume nebulizer (SVN), when heated humidifiers were not employed. When heated and humidified medical gas was used, there was no significant difference between the inhaled drug mass delivered by the VMN and that delivered by the SVN. A significantly greater mass of inhaled 1.55-µm drug particles was produced by the VMN than with the SVN, under heated and humidified conditions. However, the mass median aerodynamic diameters (MMADs) of the aerosolized drug produced by the SVN and VMN did not differ significantly under the same conditions. CONCLUSIONS: The VMN produced more fine particles of salbutamol/ipratropium, and the drug particle size clearly increased in the presence of heat and humidification.


Assuntos
Combinação Albuterol e Ipratrópio/administração & dosagem , Broncodilatadores/administração & dosagem , Sistemas de Liberação de Medicamentos , Pulmão/metabolismo , Administração por Inalação , Aerossóis , Combinação Albuterol e Ipratrópio/farmacocinética , Broncodilatadores/farmacocinética , Temperatura Alta , Umidade , Nebulizadores e Vaporizadores , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA