Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
J Clin Ultrasound ; 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39431601

RESUMO

PURPOSE: This study aimed to compare shear-wave elastography (SWE) USG and composition analysis of CT on the right mid-rectus femoris muscle (RF) in both healthy adults and chronic kidney disease (CKD) patients. METHODS: Sixty-three healthy adults and 22 CKD patients were included. One musculoskeletal radiologist performed right RF SWE USG, while two radiologists measured shear-wave velocity (SWV) from the same SWE images. CT scan was performed, and muscle composition was measured using imageJ, categorized into four HU-based compositions. Interobserver agreement for SWV between two readers was evaluated. Correlations between SWV and CT compositions were analyzed using Pearson's or Spearman's correlation. RESULTS: SWV of healthy group was significantly higher than CKD group by each reader (p = 0.030 and 0.038). The percentage of low-density muscle was higher in CKD group than healthy group (p < 0.001), and the percentage of normal density muscle was higher in healthy group than CKD (p < 0.001) by each reader. Interobserver agreement of SWV by the two readers was almost perfect in both groups (k = 0.957-0.984, 0.959-0.993). There was a statistically significant correlation between SWV and the percentage of normal density muscle on CT in both healthy adults and CKD patient groups (Reader 1, r = 0.318-0.480, p = 0.001 and 0.024; Reader 2, r = 0.511-0.518, p < 0.001 and p = 0.013). CONCLUSIONS: SWV demonstrated a significant correlation with the percentage of normal density muscle on CT in both healthy adults and CKD patients by each reader. SWE provides a radiation-free approach that may offer an objective method for evaluating muscle quality, potentially making it an option for muscle monitoring.

2.
Quant Imaging Med Surg ; 14(9): 6531-6542, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39281122

RESUMO

Background: Heavily T2-weighted fat-saturated (HT2W-FS) magnetic resonance myelography (MRM) is useful for diagnosing the cause of intracranial hypotension. Recently, deep learning-based reconstruction (DLR) has been utilized to improve image signal-to-noise ratios and sharpness while reducing artifacts, all without lengthening acquisition times. This study aimed to compare the diagnostic performance and image quality of conventional reconstruction (CR) and DLR of 3-dimensional (3D) HT2W-FS MRM applied to detecting epidural fluid in patients with clinically suspected intracranial hypotension. Methods: This retrospective study included 21 magnetic resonance myelography examinations using both CR and DLR in 21 patients who experienced orthostatic headache between April 2021 and September 2022. Quantitative image quality evaluation was performed by comparing signal-to-noise ratios at the lower thoracic levels. The image quality and artifacts were graded by three readers. The presence of epidural fluid was reported with a confidence score by two readers, and the area under the receiver operating curve, interobserver agreement, and inter-image-set agreement were evaluated. The conspicuity of the dura mater where the epidural fluid was detected was also investigated. Results: Quantitative and subjective image quality, and artifacts significantly improved with DLR (all P<0.001). Diagnostic performance of DLR was higher for both readers [reader 1: area under the curve (AUC) of CR =0.929; 95% confidence interval (CI): 0.902-0.950, AUC of DLR =0.965 (95% CI: 0.944-0.979), P=0.007; reader 2: AUC of CR =0.834 (95% CI: 0.798-0.866), AUC of DLR =0.877 (0.844-0.905), P=0.040]. Correlation with standard care of MRM in CR and DLR were both strong in reader 1 (rho =0.868-0.919, P<0.001), but was respectively strong and moderate in reader 2 (rho =0.734-0.805, P<0.001). Interobserver agreement was substantial (κ=0.708-0.762). The inter-image-set agreement was almost perfect for reader 1 (κ=0.907) and was substantial for reader 2 (κ=0.750). Dura mater conspicuity significantly improved with DLR (P<0.014, reader 1; P<0.001, readers 2 and 3). Conclusions: HT2W-FS magnetic resonance myelography with DLR demonstrates substantial improvements in image quality and may improve confidence in detecting epidural fluid.

3.
Eur J Radiol ; 175: 111471, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38636411

RESUMO

PURPOSE: With the slice thickness routinely used in elbow MRI, small or subtle lesions may be overlooked or misinterpreted as insignificant. To compare 1 mm slice thickness MRI (1 mm MRI) with deep learning reconstruction (DLR) to 3 mm slice thickness MRI (3 mm MRI) without/with DLR, and 1 mm MRI without DLR regarding image quality and diagnostic performance for elbow tendons and ligaments. METHODS: This retrospective study included 53 patients between February 2021 and January 2022, who underwent 3 T elbow MRI, including T2-weighted fat-saturated coronal 3 mm and 1 mm MRI without/with DLR. Two radiologists independently assessed four MRI scans for image quality and artefacts, and identified the pathologies of the five elbow tendons and ligaments. In 19 patients underwent elbow surgery after elbow MRI, diagnostic performance was evaluated using surgical records as a reference standard. RESULTS: For both readers, 3 mm MRI with DLR had significant higher image quality scores than 3 mm MRI without DLR and 1 mm MRI with DLR (all P < 0.01). For common extensor tendon and elbow ligament pathologies, 1 mm MRI with DLR showed the highest number of pathologies for both readers. The 1 mm MRI with DLR had the highest kappa values for all tendons and ligaments. For reader 1, 1 mm MRI with DLR showed superior diagnostic performance than 3 mm MRI without/with DLR. For reader 2, 1 mm MRI with DLR showed the highest diagnostic performance; however, there was no significant difference. CONCLUSIONS: One mm MRI with DLR showed the highest diagnostic performance for evaluating elbow tendon and ligament pathologies, with similar subjective image qualities and artefacts.


Assuntos
Aprendizado Profundo , Articulação do Cotovelo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Articulação do Cotovelo/diagnóstico por imagem , Idoso , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/lesões , Ligamentos/diagnóstico por imagem , Adulto Jovem , Tendões/diagnóstico por imagem
4.
Sci Rep ; 14(1): 2769, 2024 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-38307965

RESUMO

This study aimed to develop and evaluate a sarcopenia prediction model by fusing numerical features from shear-wave elastography (SWE) and gray-scale ultrasonography (GSU) examinations, using the rectus femoris muscle (RF) and categorical/numerical features related to clinical information. Both cohorts (development, 70 healthy subjects; evaluation, 81 patients) underwent ultrasonography (SWE and GSU) and computed tomography. Sarcopenia was determined using skeletal muscle index calculated from the computed tomography. Clinical and ultrasonography measurements were used to predict sarcopenia based on a linear regression model with the least absolute shrinkage and selection operator (LASSO) regularization. Furthermore, clinical and ultrasonography features were combined at the feature and score levels to improve sarcopenia prediction performance. The accuracies of LASSO were 70.57 ± 5.00-81.54 ± 4.83 (clinical) and 69.00 ± 4.52-69.73 ± 5.47 (ultrasonography). Feature-level fusion of clinical and ultrasonography (accuracy, 70.29 ± 6.63 and 83.55 ± 4.32) showed similar performance with clinical features. Score-level fusion by AdaBoost showed the best performance (accuracy, 73.43 ± 6.57-83.17 ± 5.51) in the development and evaluation cohorts, respectively. This study might suggest the potential of machine learning fusion techniques to enhance the accuracy of sarcopenia prediction models and improve clinical decision-making in patients with sarcopenia.


Assuntos
Técnicas de Imagem por Elasticidade , Sarcopenia , Humanos , Técnicas de Imagem por Elasticidade/métodos , Sarcopenia/diagnóstico por imagem , Ultrassonografia/métodos , Músculo Quadríceps , Voluntários Saudáveis
5.
Quant Imaging Med Surg ; 14(1): 722-735, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223037

RESUMO

Background: While anti-peristaltic agents are beneficial for high quality magnetic resonance enterography (MRE), their use is constrained by potential side effects and increased examination complexity. We explored the potential of deep learning-based reconstruction (DLR) to compensate for the absence of anti-peristaltic agent, improve image quality and reduce artifact. This study aimed to evaluate the need for an anti-peristaltic agent in single breath-hold single-shot fast spin-echo (SSFSE) MRE and compare the image quality and artifacts between conventional reconstruction (CR) and DLR. Methods: We included 45 patients who underwent MRE for Crohn's disease between October 2021 and September 2022. Coronal SSFSE images without fat saturation were acquired before and after anti-peristaltic agent administration. Four sets of data were generated: SSFSE CR with and without an anti-peristaltic agent (CR-A and CR-NA, respectively) and SSFSE DLR with and without an anti-peristaltic agent (DLR-A and DLR-NA, respectively). Two radiologists independently reviewed the images for overall quality and artifacts, and compared the three images with DLR-A. The degree of distension and inflammatory parameters were scored on a 5-point scale in the jejunum and ileum, respectively. Signal-to-noise ratio (SNR) levels were calculated in superior mesenteric artery (SMA) and iliac bifurcation level. Results: In terms of overall quality, DLR-NA demonstrated no significant difference compared to DLR-A, whereas CR-NA and CR-A demonstrated significant differences (P<0.05, both readers). Regarding overall artifacts, reader 1 rated DLR-A slightly better than DLR-NA in four cases and rated them as identical in 41 cases (P=0.046), whereas reader 2 demonstrated no difference. Bowel distension was significantly different in the jejunum (Reader 1: P=0.046; Reader 2: P=0.008) but not in the ileum. Agreements between the images (Reader 1: ĸ=0.73-1.00; Reader 2: ĸ=1.00) and readers (ĸ=0.66 for all comparisons) on inflammation were considered good to excellent. The sensitivity, specificity, and accuracy in diagnosing inflammation in the terminal ileum were the same among DLR-NA, DLR-A, CR-NA and CR-A (94.42%, 81.83%, and 89.69 %; and 83.33%, 90.91%, and 86.21% for Readers 1 and 2, respectively). In both SMA and iliac bifurcation levels, SNR of DLR images exhibited no significant differences. CR images showed significantly lower SNR compared with DLR images (P<0.001). Conclusions: SSFSE without anti-peristaltic agents demonstrated nearly equivalent quality to that with anti-peristaltic agents. Omitting anti-peristaltic agents before SSFSE and adding DLR could improve the scanning outcomes and reduce time.

7.
Skeletal Radiol ; 52(8): 1545-1555, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36943429

RESUMO

OBJECTIVE: To compare the image quality and agreement among conventional and accelerated periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) MRI with both conventional reconstruction (CR) and deep learning-based reconstruction (DLR) methods for evaluation of shoulder. MATERIALS AND METHODS: We included patients who underwent conventional (acquisition time, 8 min) and accelerated (acquisition time, 4 min and 24 s; 45% reduction) PROPELLER shoulder MRI using both CR and DLR methods between February 2021 and February 2022 on a 3 T MRI system. Quantitative evaluation was performed by calculating the signal-to-noise ratio (SNR). Two musculoskeletal radiologists compared the image quality using conventional sequence with CR as the reference standard. Interobserver agreement between image sets for evaluating shoulder was analyzed using weighted/unweighted kappa statistics. RESULTS: Ninety-two patients with 100 shoulder MRI scans were included. Conventional sequence with DLR had the highest SNR (P < .001), followed by accelerated sequence with DLR, conventional sequence with CR, and accelerated sequence with CR. Comparison of image quality by both readers revealed that conventional sequence with DLR (P = .003 and P < .001) and accelerated sequence with DLR (P = .016 and P < .001) had better image quality than the conventional sequence with CR. Interobserver agreement was substantial to almost perfect for detecting shoulder abnormalities (κ = 0.600-0.884). Agreement between the image sets was substantial to almost perfect (κ = 0.691-1). CONCLUSION: Accelerated PROPELLER with DLR showed even better image quality than conventional PROPELLER with CR and interobserver agreement for shoulder pathologies comparable to that of conventional PROPELLER with CR, despite the shorter scan time.


Assuntos
Aprendizado Profundo , Ombro , Humanos , Ombro/diagnóstico por imagem , Artefatos , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído
8.
Life (Basel) ; 13(2)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36836759

RESUMO

Background: This study evaluated the efficacy and safety of pulmonary rehabilitation (PR) on functional performance, exercise-related oxygen saturation, and health-related quality of life among patients with idiopathic pulmonary fibrosis (IPF). Methods: A total of 25 patients with IPF (13 in the PR group and 12 in the non-PR group) were enrolled between August 2019 and October 2021 at Haeundae-Paik Hospital in the Republic of Korea. A cardiopulmonary exercise test (CPET), six-minute walk test (6MWT), pulmonary function test (PFT), Saint George's Respiratory Questionnaire (SGRQ), muscle strength test, and bioelectrical impedance analysis were performed in each group at baseline and after eight weeks of PR. Results: The mean age was 68 years of age and most subjects were male. Baseline characteristics were similar between the two groups. The distance during 6MWT after PR was significantly improved in the PR group (inter-group p-value = 0.002). VO2max and VE/VCO2 slopes showed a significant difference after eight weeks only in the PR group, but the rate of change did not differ significantly from the non-PR group. Total skeletal muscle mass, PFT variables, and SGRQ scores did not differ significantly between the groups. Conclusions: PR improved exercise capacity, as measured using CPET and 6 MWT. Further studies in larger samples are needed to evaluate the long-term efficacy of PR in IPF patients.

9.
J Clin Ultrasound ; 51(4): 703-710, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36710597

RESUMO

PURPOSE: The purpose of this study was to compare the measurement of shear wave elastography (SWE) and gray scale ultrasonography (GSU) and CT attenuation of mid-rectus femoris (RF) muscle in healthy adults. METHODS: This prospective study included 70 participants with a healthy body mass index (<25 kg/m2 ) between June 2019 and January 2020. Echo intensity (EI) grading of RF on GSU was performed. SWE was performed for the three levels of the RF. Measurements were repeated 10 min after the first measurement. The mid-RF attenuation on CT was also measured. Interobserver agreement of EI grade among three readers was assessed using weighted-kappa statistics. The reliability of SWE was assessed using intraclass correlation coefficient. The correlations between the SWE and CT/GSU measurements were analyzed. RESULTS: Interobserver agreement of EI grade on GSU by the three radiologists was moderate to substantial (k = 0.562-0.767). The inter-session agreements for SWE were almost perfect for mid RF (k = 0.822-0.829) and substantial for proximal and distal RF (k = 0.767-0.795). There were significant correlations between SWE-EI and SWE-CT attenuation (p < 0.001, respectively) at the mid-RF. CONCLUSIONS: SWE measurements on mid-RF demonstrated the highest reliability. SWE parameters showed a strong correlation with EI on GSU and attenuation on CT.


Assuntos
Técnicas de Imagem por Elasticidade , Adulto , Humanos , Músculo Quadríceps/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X
10.
J Clin Ultrasound ; 51(3): 510-517, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36201602

RESUMO

PURPOSE: We aim to evaluate the shear wave velocity (SWV) of the thenar muscle as an adjunct diagnostic tool for carpal tunnel syndrome (CTS). METHODS: Ninety-two wrists with CTS and 30 control wrists without CTS underwent ultrasonographic evaluation of thenar muscle and median nerve including shear-wave elastography. Cross sectional area (CSA) of medial nerve and SWV of thenar muscle and median nerve were evaluated. CTS patients were assessed for Boston CTS, Padua CTS, modified Hirani grading scores, and nerve conduction study (NCS). SWVs, CSA, and NCS parameters were compared between two groups. RESULTS: The SWVs of thenar muscle and median nerve (p < 0.001, respectively), and CSA of median nerve (p < 0.001) were more significantly greater in patients with CTS than in controls. The SWV of median nerve was moderately correlated with CSA of median nerve (r = 0.35, p < 0.001) and modified Hirani CTS score (r = 0.35, p < 0.001). The SWV of thenar muscle was inversely correlated with modified Hirani CTS score (r = -0.21, p = 0.04). CONCLUSION: The SWV of thenar muscle and median nerve of CTS were significantly increased compared to that of control, and significantly negatively correlated with NCS parameters (modified Hirani CTS score). SWVs may be used as an adjunct diagnostic tool for CTS.


Assuntos
Síndrome do Túnel Carpal , Técnicas de Imagem por Elasticidade , Humanos , Síndrome do Túnel Carpal/diagnóstico por imagem , Ultrassonografia , Condução Nervosa/fisiologia , Nervo Mediano/diagnóstico por imagem , Músculo Esquelético
11.
J Clin Ultrasound ; 51(1): 123-130, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36169174

RESUMO

PURPOSE: This study aimed to compare the diagnostic performance of gray-scale ultrasound (GSU), strain elastography (SE), and shear wave elastography (SWE) for lateral epicondylitis (LE). METHODS: From November 2018 to March 2021, 87 common extensor tendons (CETs) of 70 patients were evaluated using elbow ultrasound. Patients were divided into two groups: patients with LE and those without lateral elbow pain. GSU, SE, and SWE findings from the two groups were compared, and the diagnostic performance was compared for significant variables. RESULTS: Among the 70 patients, 41 with 44 CETs were clinically diagnosed with LE, and 29 with 43 CETs had no lateral elbow pain. Hypoechogenicity, calcification, and hyperemia were significantly different. Strain ratio (SR), stiffness, and shear wave velocity (SWV) were also significantly different. The diagnostic accuracy of stiffness and SWV was better than that of other significant findings. Furthermore, there were no superiorities in SR, stiffness, or SWV. CONCLUSION: Both SE and SWE can be valuable diagnostic tools for diagnosing LE. The diagnostic performances of both SE and SWE were similar in the detection of LE.


Assuntos
Técnicas de Imagem por Elasticidade , Cotovelo de Tenista , Humanos , Cotovelo de Tenista/diagnóstico por imagem , Ultrassonografia
12.
Sci Rep ; 12(1): 3596, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246589

RESUMO

We aim to evaluate the performance of a deep convolutional neural network (DCNN) in predicting the presence or absence of sarcopenia using shear-wave elastography (SWE) and gray-scale ultrasonography (GSU) of rectus femoris muscle as an imaging biomarker. This retrospective study included 160 pair sets of GSU and SWE images (n = 160) from December 2018 and July 2019. Two radiologists scored the echogenicity of muscle on GSU (4-point score). Among them, 141 patients underwent CT and their L3 skeletal muscle index (SMI) were measured to categorize the presence or absence of sarcopenia. For DCNN, we used three CNN architectures (VGG19, ResNet-50, DenseNet 121). The accuracies of DCNNs for sarcopenia classification were 70.0-80.0% (based on SWE) and 65.0-75.0% (based on GSU). The DCNN application to SWE images highlights the utility of deep-learning base SWE for sarcopenia prediction. DCNN application to SWE images might be a potentially useful biomarker to predict sarcopenic status.


Assuntos
Aprendizado Profundo , Técnicas de Imagem por Elasticidade , Sarcopenia , Técnicas de Imagem por Elasticidade/métodos , Humanos , Músculo Quadríceps/diagnóstico por imagem , Estudos Retrospectivos , Sarcopenia/diagnóstico por imagem , Ultrassonografia/métodos
13.
AJR Am J Roentgenol ; 218(3): 506-516, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34523950

RESUMO

BACKGROUND. Shoulder MRI using standard multiplanar sequences requires long scan times. Accelerated sequences have tradeoffs in noise and resolution. Deep learning-based reconstruction (DLR) may allow reduced scan time with preserved image quality. OBJECTIVE. The purpose of this study was to compare standard shoulder MRI sequences and accelerated sequences without and with DLR in terms of image quality and diagnostic performance. METHODS. This retrospective study included 105 patients (45 men, 60 women; mean age, 57.6 ± 10.9 [SD] years) who underwent a total of 110 3-T shoulder MRI examinations. Examinations included standard sequences (scan time, 9 minutes 23 seconds) and accelerated sequences (3 minutes 5 seconds; 67% reduction), both including fast spin-echo sequences in three planes. Standard sequences were reconstructed using the conventional pipeline; accelerated sequences were reconstructed using both the conventional pipeline and a commercially available DLR pipeline. Two radiologists independently assessed three image sets (standard sequence, accelerated sequence without DLR, and accelerated sequence with DLR) for subjective image quality and artifacts using 4-point scales (4 = highest quality) and identified pathologies of the subscapularis tendon, supraspinatus-infraspinatus tendon, long head of the biceps brachii tendon, and glenoid labrum. Interobserver agreement and agreement between image sets for the evaluated pathologies were assessed using weighted kappa statistics. In 27 patients who underwent arthroscopy, diagnostic performance was calculated using arthroscopic findings as a reference standard. RESULTS. Mean subjective image quality scores for readers 1 and 2 were 10.6 ± 1.2 and 10.5 ± 1.4 for the standard sequence, 8.1 ± 1.3 and 7.2 ± 1.1 for the accelerated sequence without DLR, and 10.7 ± 1.2 and 10.5 ± 1.6 for the accelerated sequence with DLR. Mean artifact scores for readers 1 and 2 were 9.3 ± 1.2 and 10.0 ± 1.0 for the standard sequence, 7.3 ± 1.3 and 9.1 ± 0.8 for the accelerated sequence without DLR, and 9.4 ± 1.2 and 9.8 ± 0.8 for the accelerated sequence with DLR. Interobserver agreement ranged from kappa of 0.813-0.951 except for accelerated sequence without DLR for the supraspinatus-infraspinatus tendon (κ = 0.673). Agreement between image sets ranged from kappa of 0.809-0.957 except for reader 1 for supraspinatus-infraspinatus tendon (κ = 0.663-0.700). Accuracy, sensitivity, and specificity for tears of the four structures were not different (p > .05) among image sets. CONCLUSION. Accelerated sequences with DLR provide 67% scan time reduction with similar subjective image quality, artifacts, and diagnostic performance to standard sequences. CLINICAL IMPACT. Accelerated sequences with DLR may provide an alternative to standard sequences for clinical shoulder MRI.


Assuntos
Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Lesões do Ombro/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Articulação do Ombro/diagnóstico por imagem
14.
Eur Radiol ; 31(9): 6726-6735, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33634322

RESUMO

OBJECTIVES: To evaluate the ability of shear wave elastography (SWE) in diagnosing medial epicondylitis and to compare the diagnostic performance of SWE with that of grey-scale ultrasound (GSU) and strain elastography (SE). METHODS: GSU, SE, and SWE were performed on 61 elbows of 54 patients from March 2018 to April 2019. An experienced radiologist evaluated the GSU findings (swelling, cortical irregularity, hypoechogenicity, calcification, and tear), colour Doppler findings (hyperaemia), SE findings (strain ratio [SR]), and SWE findings (stiffness and shear wave velocity [SWV]). Participants were divided in two groups: patients with clinically diagnosed medial epicondylitis and patients without medial elbow pain. Findings from the two groups were compared, and the receiver operating characteristic (ROC) curves were calculated for significant features. RESULTS: Of the 54 patients, 25 patients with 28 imaged elbows were clinically diagnosed with medial epicondylitis and 29 patients with 33 imaged elbows had no medial elbow pain. Cortical irregularity, hypoechogenicity, calcification, hyperaemia, SR, stiffness, and SWV were significantly different between the two groups. The areas under the ROC curves were 0.838 for hypoechogenicity, 0.948 for SR, 0.999 for stiffness, and 0.999 for SWV. The diagnostic performances of SR, stiffness, and SWV were significantly superior compared to that of hypoechogenicity. However, there were no significant differences among SR, stiffness, and SWV. CONCLUSIONS: SWE can obtain both stiffness and SWV, which are valuable diagnostic tools in the diagnosis of medial epicondylitis. The diagnostic performance of SWE and SE is similar in detecting medial epicondylitis. KEY POINTS: • Shear wave elastography providing stiffness and shear wave velocity showed excellent performance in the diagnosis of medial epicondylitis. • There was no significant difference in the ability of SE and SWE for diagnosing medial epicondylitis.


Assuntos
Técnicas de Imagem por Elasticidade , Articulação do Cotovelo , Tendinopatia do Cotovelo , Articulação do Cotovelo/diagnóstico por imagem , Humanos , Curva ROC , Ultrassonografia
15.
Taehan Yongsang Uihakhoe Chi ; 82(3): 613-625, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-36238785

RESUMO

Purpose: To evaluate the MRI findings and clinical factors that are characteristic of patients who ultimately undergo surgery for medial epicondylitis. Materials and Methods: Fifty-two consecutive patients who were diagnosed with medial epicondylitis and underwent an elbow MRI between March 2010 and December 2018 were included in this retrospective study. The patients' demographic information, clinical data, and MRI findings were evaluated. All variables were compared between the conservative treatment and surgical treatment groups. Logistic regression analyses were conducted to identify which factors were associated with surgical treatment. Results: Common flexor tear (CFT) tear size showed a statistically significant difference in both the transverse and longitudinal planes (p < 0.001, p = 0.013). The CFT abnormality grade significantly differed in both the transverse and longitudinal planes (p = 0.022, p = 0.003). A significant difference was also found in the medial collateral ligament abnormality (p = 0.025). Logistic regression analyses showed that only the transverse diameter of the CFT tear size (odds ratio: 1.864; 95% confidence interval: 1.264-2.750) was correlated with surgical treatment. Conclusion: Of patients diagnosed with medial epicondylitis, patients with a larger transverse CFT tear size tend to undergo surgical treatment ultimately.

16.
J Ultrasound Med ; 40(5): 1011-1021, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32852107

RESUMO

OBJECTIVES: To compare the diagnostic performance between strain elastography and shear wave elastography (SWE) for the diagnosis of carpal tunnel syndrome (CTS). METHODS: Between July 2018 and June 2019, 66 consecutive patients with 95 imaged wrists underwent wrist ultrasound, including grayscale ultrasound, strain elastography, and SWE, because of the suspicion of CTS. During wrist ultrasound, the cross-sectional area (CSA), strain ratio, elasticity, and shear wave velocity of each median nerve were measured at the proximal carpal bone level (scaphoid to pisiform). The variables were compared between the normal and CTS groups by using the independent t test, and subgroup analyses were performed using one-way analysis of variance. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic performance of each variable. RESULTS: CSA, elasticity, and shear wave velocity showed significant intergroup differences (P < 0.001, P < 0.001, and P = 0.002, respectively). However, the strain ratio showed no statistically significant intergroup difference (P = 0.639). In the subgroup analyses, elasticity showed significantly higher values in the severe group than in the mild and moderate groups (P < 0.001 and P = 0.001, respectively). Other parameters showed no significant differences among the different subgroups. The areas under the ROC curve were 0.823 for CSA, 0.772 for elasticity, and 0.779 for shear wave velocity. The differences in the areas under the ROC curve among CSA, elasticity, and shear wave velocity were not statistically significant (all P > 0.05). CONCLUSIONS: SWE has a good diagnostic value in CTS. In particular, elasticity can discriminate the severe group from the other groups.


Assuntos
Síndrome do Túnel Carpal , Técnicas de Imagem por Elasticidade , Síndrome do Túnel Carpal/diagnóstico por imagem , Humanos , Nervo Mediano/diagnóstico por imagem , Punho/diagnóstico por imagem , Articulação do Punho
17.
Eur Radiol ; 31(3): 1597-1607, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33128599

RESUMO

OBJECTIVES: To clarify CT findings that predict outcome of conservative treatment in patients with non-strangulated adhesive small bowel obstruction (SBO). METHODS: Unenhanced and contrast-enhanced abdominopelvic CT studies in 189 patients with adhesive SBO who had initial conservative treatment were reviewed. The CT findings included transition zone, beak signs, maximum bowel diameter, bowel diameter ratio, decreased bowel wall enhancement, increased unenhanced bowel wall attenuation, anterior parietal adhesion, bowel wall thickening, closed-loop obstruction, small bowel feces sign, whirl sign, mesenteric haziness, mesenteric, peritoneal fluid, and submucosal edema. These findings were statistically compared according to the success or failure of treatment. RESULTS: Conservative treatment succeeded in 144 patients (76.2%) and failed in 45 patients (23.8%). At multivariate analysis, the lack of small bowel feces sign, focal, diffuse mesenteric haziness, and moderate amount of mesenteric fluid were independent findings predicting failure of conservative treatment, with odds ratios of 5.23, 5.5, 13.55, and 4.89, respectively. The presence of all significant findings showed a high specificity of 97.2% with positive likelihood ratio of 8.8. If CT scans showed none of the three significant findings, the negative predictive value was 97.6% and negative likelihood ratio was 0.08. CONCLUSIONS: The lack of small bowel feces sign, focal, diffuse mesenteric haziness, and moderate amount of mesenteric fluid are independent CT findings predicting the failure of conservative treatment in patients with non-strangulated adhesive SBO. The combination of all CT findings suggests the need for surgery; absence of two or all CT findings should suggest an attempt for conservative treatment. KEY POINTS: • To minimize delayed operation, it is important to identify non-strangulated adhesive small bowel obstruction patients in whom initial conservative treatment is likely to fail. • The lack of small bowel feces sign, the presence of mesenteric haziness, and a moderate amount of mesenteric fluid are independent factors predicting the failure of conservative treatment in patients with non-strangulated adhesive small bowel obstruction. • The combination of all three CT findings suggests the need for surgery; absence of two or all three CT findings should suggest an attempt for conservative treatment.


Assuntos
Tratamento Conservador , Obstrução Intestinal , Adesivos , Humanos , Obstrução Intestinal/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
18.
Eur J Radiol ; 112: 52-58, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30777219

RESUMO

OBJECTIVES: To investigate the feasibility of three-dimensional fast spin echo (3D-FSE) imaging with compressed sensing (CS) and parallel imaging (PI) compared to 3D-FSE imaging with only PI in evaluating ankle joint pathologies. MATERIALS AND METHODS: Twenty consecutive patients underwent ankle magnetic resonance imaging (MRI), including acquisition of image sets of 2D-FSE sequences, and 3D-FSE sequences without and with CS, between June 2016 and November 2017. Three MR image sets were independently rated by two radiologists for the presence/absence of ankle pathology. Quantitative image similarity and subjective image quality were evaluated using 3D-FSE images without CS and those with CS-PI. Inter-sequence agreement between 3D-FSE sequences without CS and with CS-PI in both readers was evaluated. RESULTS: Interobserver agreements were nearly perfect for sprain of the anterior talofibular ligament (ATFL, κ=0.77), osteochondral lesion of the talus (OLT, κ=0.76-0.88), osteochondral lesion of the distal tibia (OLTi, κ=0.74) and os subfibulare (OSF, κ=0.62-0.64). The structural similarity index (mean, 0.996; range, 0.990-0.997) between the 3D-FSE sequences without CS and with CS-PI was acceptable. There was no significant difference in subjective image quality between the two imaging sequences (ATFL, p = 0.317; bone marrow, p = 0.083; cartilage, p = 1.000, tendon, p = 1.000). Intersequence agreement between the 3D-FSE sequences with and without CS was nearly perfect (ATFL and OLTi, κ=1.00; OLT, κ=0.87-0.96; OSF, κ=0.62-0.64) in both readers. CONCLUSIONS: Isotropic 3D-FSE ankle MRI with CS provides acceptable diagnostic performance with reduced scan time. Compressed sensing-related artifacts could be minimized with CS reconstruction enhancement, allowing for better image quality for evaluating ankle joint pathologies.


Assuntos
Articulação do Tornozelo/patologia , Artropatias/patologia , Adulto , Artefatos , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Pressão , Sensibilidade e Especificidade , Tálus/patologia
19.
Ultrasound Med Biol ; 45(1): 246-254, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30352727

RESUMO

The aim of this study was to evaluate the diagnostic potential of real-time sonoelastography (RSE) in medial epicondylitis by comparing clinically diagnosed patients and patients without medial elbow pain. From July 2016 to December 2017, gray-scale sonographic findings (swelling, cortical irregularity, hypo-echogenicity, calcification and tear), color Doppler findings (hyperemia) and sonoelastographic findings (elastographic grade on a 3-point visual scale and strain ratio from two regions of interest) for 63 elbows of 56 patients were compared. Twenty-four patients with 29 imaged elbows were clinically diagnosed with medial epicondylitis, and 32 patients with 34 imaged elbows had no medial elbow pain. Cortical irregularity, hypo-echogenicity, calcification, elastographic grade and strain ratio revealed significant differences (p < 0.05). Among these, strain ratio had the highest diagnostic performance (area under the curve: 0.985). Real-time sonoelastography, which can obtain both elastographic grade and strain ratio, is valuable as a supplementary tool in the diagnosis of medial epicondylitis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Tendinopatia do Cotovelo/diagnóstico por imagem , Tendinopatia do Cotovelo/patologia , Tendões/diagnóstico por imagem , Tendões/patologia , Adulto , Idoso , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Eur Radiol ; 29(5): 2573-2580, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30488107

RESUMO

OBJECTIVES: To investigate the agreement between double-inversion recovery (DIR) with synthetic magnetic resonance imaging (MRI) and T1-weighted contrast-enhanced (CE)-MRI for the assessment of knee synovitis. METHODS: T1-weighted CE-MRI and synthetic MRI of 30 patients were compared. Synthetic DIR image reconstruction was performed with two inversion times (280-330 ms and 2800-2900 ms). Subjective image quality, visibility of synovium, detection of synovitis, and total synovitis score in the knee joint were evaluated on both MR images. The relative signal intensity (SI) and relative contrast of synovium, joint effusion, and bone marrow for two imaging were assessed. Differences in data between two imaging were assessed by using Wilcoxon's signed-rank test and chi-square test/Fisher's exact test. Interobserver agreement was expressed as weighted kappa value. Accuracy of synthetic DIR image was calculated by using CE-MRI as reference standard. RESULTS: T1-weighted CE-MRI yielded better image quality than synthetic DIR imaging (p < 0.001). Interobserver agreements for detecting synovitis diagnosis/sum of the synovitis score were moderate to almost perfect (κ = 0.58/0.44, synthetic DIR; κ = 0.83/0.65, T1-weighted CE-MRI). There were no statistical differences in visibility of synovium (p = 0.058-0.190), detection of synovitis (p < 0.001), and relative SI of structures between two imaging (p = 0.086-0.360). Synovium-to-effusion contrast was higher in synthetic DIR (p = 0.003) and synovium-to-bone marrow contrast was higher in CE-MRI (p < 0.001). CONCLUSION: Synthetic DIR imaging showed a moderate degree of interobserver agreement and good accuracy for detecting synovitis. Though it has limitations, it may play a role in imaging of degenerative joint disease or larger cohort scientific studies where gadolinium application is not feasible. KEY POINTS: • Synthetic double-inversion recovery (DIR) imaging avoids the use of contrast agent. • There was no significant difference between T1-weighted CE-MRI and synthetic DIR imaging in evaluating presence of synovitis in knee joint. • Synthetic DIR imaging showed moderate degree of interobserver agreement and good accuracy for detecting synovitis compared to CE-MRI, and it may facilitate evaluation of some regions of peripatellar synovitis.


Assuntos
Processamento de Imagem Assistida por Computador , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Membrana Sinovial/patologia , Sinovite/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Curva ROC , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA