Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Assunto principal
Tipo de documento
Intervalo de ano de publicação
1.
Nanomaterials (Basel) ; 14(7)2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38607098

RESUMO

Tympanic membrane (TM) perforations, primarily induced by middle ear infections, the introduction of foreign objects into the ear, and acoustic trauma, lead to hearing abnormalities and ear infections. We describe the design and fabrication of a novel composite patch containing photocrosslinkable gelatin methacryloyl (GelMA) and keratin methacryloyl (KerMA) hydrogels. GelMA-KerMA patches containing conical microneedles in their design were developed using the digital light processing (DLP) 3D printing approach. Following this, the patches were biofunctionalized by applying a coaxial coating with PVA nanoparticles loaded with gentamicin (GEN) and fibroblast growth factor (FGF-2) with the Electrohydrodynamic Atomization (EHDA) method. The developed nanoparticle-coated 3D-printed patches were evaluated in terms of their chemical, morphological, mechanical, swelling, and degradation behavior. In addition, the GEN and FGF-2 release profiles, antimicrobial properties, and biocompatibility of the patches were examined in vitro. The morphological assessment verified the successful fabrication and nanoparticle coating of the 3D-printed GelMA-KerMA patches. The outcomes of antibacterial tests demonstrated that GEN@PVA/GelMA-KerMA patches exhibited substantial antibacterial efficacy against Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli. Furthermore, cell culture studies revealed that GelMA-KerMA patches were biocompatible with human adipose-derived mesenchymal stem cells (hADMSC) and supported cell attachment and proliferation without any cytotoxicity. These findings indicated that biofunctional 3D-printed GelMA-KerMA patches have the potential to be a promising therapeutic approach for addressing TM perforations.

2.
Analyst ; 147(3): 516-526, 2022 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-35044380

RESUMO

Several fundamentally similar, miniaturized solid-state reference electrode designs, and their fabrication and comparison are described in this article. All electrodes were based on Ag/AgCl as their reference element. The best electrode (a three-layer assembly with graphite oxide, epoxy, and hardener as the framework providers and with well-mixed micro-Ag particles in the bottom layer, AgCl in the middle layer, and fine KCl powder in the top layer) exhibited satisfactory short-term performance to replace a commercial reference electrode in many cases and was rigorously tested in terms of pH response, long-term leakage, and the effect of oxygen to better evaluate its characteristics. To assess the electrode's performance in medically important studies, cytotoxicity experiments and tests in artificial saliva were also conducted. All tests demonstrated that our best reference electrode was stable and had a long shelf life.


Assuntos
Grafite , Prata , Eletrodos , Microeletrodos , Óxidos , Potenciometria
3.
Anal Sci ; 37(7): 971-976, 2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-33250453

RESUMO

In this work, we proposed a new wireless sensor to contribute to research aimed at continuous monitoring of nitrate and ammonium in water, which as leading agents of water pollution have become the source of a serious problem today. In this research, a well-implemented application of an electroanalytical sensor was achieved by combining it with the internet of things (IoT) concept, which is the most modern technique for wireless data collection. We developed a portable IoT system and ion-selective nitrate and ammonium electrodes and monitored the nitrate and ammonium levels of the water online. The system was produced in a low-cost manner (under $25) and it enabled data acquisition without energy-related problems, thanks to the support of solar energy and mobile power bank. The recovery rates of the sensors were tested with the standard addition method and response was obtained between 101.74 and 147.01%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA