Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Cereb Blood Flow Metab ; : 271678X241238820, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38477292

RESUMO

Stimulation of the M4 muscarinic acetylcholine receptor reduces striatal hyperdopaminergia, suggesting its potential as a therapeutic target for schizophrenia. Emraclidine (CVL-231) is a novel, highly selective, positive allosteric modulator (PAM) of M4 muscarinic acetylcholine receptors i.e. acts as a modulator that increases the response of these receptors. First, we aimed to further characterize the positron emission tomography (PET) imaging and quantification performance of a recently developed M4 PAM radiotracer, [11C]MK-6884, in non-human primates (NHPs). Second, we applied these results to determine the receptor occupancy of CVL-231 as a function of dose. Using paired baseline-blocking PET scans, we quantified total volume of distribution, binding potential, and receptor occupancy. Both blood-based and reference region-based methods quantified M4 receptor levels across brain regions. The 2-tissue 4-parameter kinetic model best fitted regional [11C]MK-6884-time activity curves. Only the caudate nucleus and putamen displayed statistically significant [11C]MK-6884 uptake and dose-dependent blocking by CVL-231. For binding potential and receptor occupancy quantification, the simplified reference tissue model using the grey cerebellum as a reference region was employed. CVL-231 demonstrated dose-dependent M4 receptor occupancy in the striatum of the NHP brain and shows promise for further development in clinical trials.

3.
Eur J Nucl Med Mol Imaging ; 50(2): 344-351, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36197499

RESUMO

PURPOSE: [18F]3F4AP is a novel PET radiotracer that targets voltage-gated potassium (K+) channels and has shown promise for imaging demyelinated lesions in animal models of neurological diseases. This study aimed to evaluate the biodistribution, safety, and radiation dosimetry of [18F]3F4AP in healthy human volunteers. METHODS: Four healthy volunteers (2 females) underwent a 4-h dynamic PET scan from the cranial vertex to mid-thigh using multiple bed positions after administration of 368 ± 17.9 MBq (9.94 ± 0.48 mCi) of [18F]3F4AP. Volumes of interest for relevant organs were manually drawn guided by the CT, and PET images and time-activity curves (TACs) were extracted. Radiation dosimetry was estimated from the integrated TACs using OLINDA software. Safety assessments included measuring vital signs immediately before and after the scan, monitoring for adverse events, and obtaining a comprehensive metabolic panel and electrocardiogram within 30 days before and after the scan. RESULTS: [18F]3F4AP distributed throughout the body with the highest levels of activity in the kidneys, urinary bladder, stomach, liver, spleen, and brain and with low accumulation in muscle and fat. The tracer cleared quickly from circulation and from most organs. The clearance of the tracer was noticeably faster than previously reported in nonhuman primates (NHPs). The average effective dose (ED) across all subjects was 12.1 ± 2.2 µSv/MBq, which is lower than the estimated ED from the NHP studies (21.6 ± 0.6 µSv/MBq) as well as the ED of other fluorine-18 radiotracers such as [18F]FDG (~ 20 µSv/MBq). No differences in ED between males and females were observed. No substantial changes in safety assessments or adverse events were recorded. CONCLUSION: The biodistribution and radiation dosimetry of [18F]3F4AP in humans are reported for the first time. The average total ED across four subjects was lower than most 18F-labeled PET tracers. The tracer and study procedures were well tolerated, and no adverse events occurred.


Assuntos
Doenças Desmielinizantes , Radiometria , Masculino , Feminino , Animais , Humanos , Distribuição Tecidual , Radiometria/métodos , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos
4.
EJNMMI Radiopharm Chem ; 5(1): 11, 2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32405797

RESUMO

BACKGROUND: [13N]Ammonia is a cyclotron produced myocardial perfusion imaging agent. With the development of high-yielding [13N]ammonia cyclotron targets using a solution of 5 mM ethanol in water, there was a need to develop and validate an automated purification and formulation system for [13N]ammonia to be in a physiological compatible formulation of 0.9% sodium chloride since there is no widely available commercial system at this time. Due to its short half-life of 10 min, FDA and USP regulations allow [13N]ammonia to be tested in quality control (QC) sub-batches with limited quality control testing performed on the sub-batches for patient use. The current EP and the original USP method for the determination of the radiochemical purity and identity of [13N]ammonia depended on an HPLC method using a conductivity detector and a solvent free of other salts. This HPLC method created issues in a modern cGMP high volume PET manufacturing facility where the HPLC is used with salt containing mobile phase buffers for quality control analysis of other PET radiopharmaceuticals. Flushing of the HPLC system of residual salt buffers which may interfere with the [13N]ammonia assay can take several hours of instrument time. Since there are no mass limits on [13N]ammonia, a simplified TLC assay to determine radiochemical identity and purity could be developed to simplify and streamline QC. RESULTS: We have developed and validated a streamlined automated synthesis for [13N]ammonia which provides the drug product in 8 mL of 0.9% sodium chloride for injection. A novel radio-TLC method was developed and validated to demonstrate feasibility to quantitate [13N]ammonia and separate it from all known radiochemical impurities. CONCLUSIONS: The process for automated synthesis of [13N]ammonia simplifies and automates the purification and formulation of [13N]ammonia in a cGMP compliant manner needed for high-throughput manufacture of [13N]ammonia. The novel radio-TLC method has simplified [13N]ammonia quality control (QC) and now enables it to be tested using the same QC equipment as [18F]fludeoxyglucose (FDA/USP recognized name for 2-[18F]fluoro-2-deoxy-D-glucose). Both the streamlined automated synthesis of [13N]ammonia and the novel radio-TLC method have been accepted and approved by the US Food and Drug Administration (FDA) for the cGMP manufacture of [13N]ammonia.

5.
Eur J Nucl Med Mol Imaging ; 46(10): 2099-2111, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31332496

RESUMO

PURPOSE: [18F]MK6240 was developed for PET imaging of tau aggregates, which are implicated in Alzheimer's disease. The goal of this work was to evaluate the kinetics of [18F]MK6240 and to investigate different strategies for in-vivo quantification of tau aggregates in humans. METHODS: Thirty-five subjects, consisting of 18 healthy controls (CTRL), 11 subjects with mild cognitive impairment (MCI) and six with Alzheimer's Disease (AD), underwent dynamic [18F]MK6240 PET scans. Arterial blood measurements were collected in 16 subjects (eight CTRLs, six MCIs and two AD) to measure whole blood and plasma concentration time courses. Radiometabolite analysis was performed on a subset of plasma samples. Various compartmental model configurations as well as the Logan and multilinear analysis (MA1) graphical methods with arterial plasma input function were tested. Simplified reference tissue methods were investigated, including Logan distribution volume ratio (DVR), multilinear reference tissue method (MRTM2), and static SUV ratio using the cerebellum as a reference region. RESULTS: Whole blood:plasma ratio stabilized to 0.66 ± 0.01 after 15 min. Percent parent in plasma (%PP) followed a single exponential and ranged from 0 to 10% at 90 min. [18F]MK6240 in gray matter peaked quickly (SUV > 2 at ~3 min). The preferred compartmental model was a reversible two-tissue compartment model, with the blood contribution included as a model parameter (2T4k1v). Compartmental and graphical analysis methods with arterial input functions yielded concordant results, but rapid metabolism raised challenges for blood-based quantification. MCI and AD subjects demonstrated a broad range of VT as compared to CTRL subjects. DVR from MRTM2 and Logan reference tissue methods correlated with DVR calculated indirectly from compartmental modeling, but underestimation was observed in data sets with very high binding (DVR > 3). SUVR also underestimated indirect DVR from blood-based analyses in high binding regions, although a non-linear relationship was exhibited. CONCLUSIONS: [18F]MK6240 exhibited a wide dynamic range of uptake, with binding patterns in MCI/AD subjects consistent with neurofibrillary tau deposition patterns. Linearized reference tissue methods using an estimated average tissue-to-plasma efflux constant [Formula: see text] and static SUVR agreed well with blood-based methods for most data sets; however, discrepancies were noted in the highest binding cases. Caution should therefore be exercised in application of simplified methods to such data sets, and in quantitative interpretation of corresponding outcomes.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Isoquinolinas/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Proteínas tau/metabolismo , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Tomografia por Emissão de Pósitrons/normas
6.
J Labelled Comp Radiopharm ; 60(5): 263-269, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28185305

RESUMO

Fluorine-18-labelled 6-(fluoro)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([18 F]MK-6240) is a novel potent and selective positron emission tomography (PET) radiopharmaceutical for detecting human neurofibrillary tangles, which are made up of aggregated tau protein. Herein, we report the fully automated 2-step radiosynthesis of [18 F]MK-6240 using a commercially available radiosynthesis module, GE Healthcare TRACERlab FXFN . Nucleophilic fluorination of the 5-diBoc-6-nitro precursor with potassium cryptand [18 F]fluoride (K[18 F]/K222 ) was performed by conventional heating, followed by acid deprotection and semipreparative high-performance liquid chromatography under isocratic conditions. The isolated product was diluted with formulation solution and sterile filtered under Current Good Manufacturing Practices, and quality control procedures were established to validate this radiopharmaceutical for human use. At the end of synthesis, 6.3 to 9.3 GBq (170-250 mCi) of [18 F]MK-6240 was formulated and ready for injection, in an uncorrected radiochemical yield of 7.5% ± 1.9% (relative to starting [18 F]fluoride) with a specific activity of 222 ± 67 GBq/µmol (6.0 ± 1.8 Ci/µmol) at the end of synthesis (90 minutes; n = 3). [18 F]MK-6240 was successfully validated for human PET studies meeting all Food and Drug Administration and United States Pharmacopeia requirements for a PET radiopharmaceutical. The present method can be easily adopted for use with other radiofluorination modules for widespread clinical research use.


Assuntos
Radioisótopos de Flúor , Isoquinolinas/química , Emaranhados Neurofibrilares/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Radioquímica/métodos , Compostos Radiofarmacêuticos/química , Halogenação , Humanos , Isoquinolinas/síntese química , Controle de Qualidade , Compostos Radiofarmacêuticos/síntese química
7.
J Nucl Med ; 58(3): 484-491, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27660144

RESUMO

18F-T807 is a PET radiotracer developed for imaging tau protein aggregates, which are implicated in neurologic disorders including Alzheimer disease and traumatic brain injury (TBI). The current study characterizes 18F-T807 pharmacokinetics in human subjects using dynamic PET imaging and metabolite-corrected arterial input functions. Methods: Nine subjects (4 controls, 3 with a history of TBI, 2 with mild cognitive impairment due to suspected Alzheimer disease) underwent dynamic PET imaging for up to 120 min after bolus injection of 18F-T807 with arterial blood sampling. Total volume of distribution (VT) was estimated using compartmental modeling (1- and 2-tissue configurations) and graphical analysis techniques (Logan and multilinear analysis 1 [MA1] regression methods). Reference region-based methods of quantification were explored including Logan distribution volume ratio (DVR) and static SUV ratio (SUVR) using the cerebellum as a reference tissue. Results: The percentage of unmetabolized 18F-T807 in plasma followed a single exponential with a half-life of 17.0 ± 4.2 min. Metabolite-corrected plasma radioactivity concentration fit a biexponential (half-lives, 18.1 ± 5.8 and 2.4 ± 0.5 min). 18F-T807 in gray matter peaked quickly (SUV > 2 at ∼5 min). Compartmental modeling resulted in good fits, and the 2-tissue model with estimated blood volume correction (2Tv) performed best, particularly in regions with elevated binding. VT was greater in mild cognitive impairment subjects than controls in the occipital, parietal, and temporal cortices as well as the posterior cingulate gyrus, precuneus, and mesial temporal cortex. High focal uptake was found in the posterior corpus callosum of a TBI subject. Plots from Logan and MA1 graphical methods became linear by 30 min, yielding regional estimates of VT in excellent agreement with compartmental analysis and providing high-quality parametric maps when applied in voxelwise fashion. Reference region-based approaches including Logan DVR (t* = 55 min) and SUVR (80- to 100-min interval) were highly correlated with DVR estimated using 2Tv (R2 = 0.97, P < 0.0001). Conclusion:18F-T807 showed rapid clearance from plasma and properties suitable for tau quantification with PET. Furthermore, simplified approaches using DVR (t* = 55 min) and static SUVR (80-100 min) with cerebellar reference tissue were found to correlate highly with compartmental modeling outcomes.


Assuntos
Encéfalo/metabolismo , Carbolinas/farmacocinética , Imagem Molecular/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Proteínas tau/metabolismo , Adulto , Idoso , Carbolinas/sangue , Simulação por Computador , Humanos , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Modelos Biológicos , Especificidade de Órgãos , Compostos Radiofarmacêuticos/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
8.
J Labelled Comp Radiopharm ; 60(2): 140-146, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27859483

RESUMO

The radiotracer, [18 F]-THK-5351, is a highly selective and high-binding affinity PET imaging agent for aggregates of hyper-phosphorylated tau protein. Our report is a simplified 1-pot, 2-step radiosynthesis of [18 F]-THK-5351. This report is broadly applicable for routine clinical production and multi-center trials on account of favorable half-life of flourine-18 and the use of a commercially available radiosynthesis module, the GE TRACERlab™ FXFN . First, the O-THP protected tosyl precursor underwent nucleophilic fluorinating reaction with potassium cryptand fluoride ([18 F] fluoride (K[18 F]/K222 )) in Dimethyl sulfoxide at 110°C for 10 minutes followed by O-THP removal by using diluted hydrochloric acid (HCl) at same temperature. [18 F]-THK-5351 was purified via semi-preparative high-performance liquid chromatography and formulated by using 10% EtOH, United States Pharmacopeia (USP) in 0.9% sodium chloride for injection, USP and an uncorrected radiochemical yield of 21 ± 3.5%, with a specific activity of 153.11 ± 25.9 GBq/µmol (4138 ± 700 mCi/µmol) at the end of synthesis (63 minutes; n = 3).


Assuntos
Aminopiridinas/síntese química , Quinolinas/síntese química , Compostos Radiofarmacêuticos/síntese química , Aminopiridinas/química , Automação/métodos , Técnicas de Química Sintética/métodos , Quinolinas/química , Compostos Radiofarmacêuticos/química
9.
J Nucl Med ; 56(3): 489-92, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25655630

RESUMO

UNLABELLED: Translation of new methodologies for labeling nonactivated aromatic molecules with (18)F remains a challenge. Here, we report a one-step, regioselective, metal-free (18)F-labeling method that uses a hypervalent iodonium(III) ylide precursor, to prepare the radiopharmaceutical (18)F-3-fluoro-5-[(pyridin-3-yl)ethynyl]benzonitrile ((18)F-FPEB). METHODS: Automated radiosynthesis of (18)F-FPEB was achieved by reaction of the ylide precursor (4 mg) with (18)F-Et4NF in dimethylformamide at 80°C for 5 min and formulated for injection within 1 h. RESULTS: (18)F-FPEB was synthesized in 20% ± 5% (n = 3) uncorrected radiochemical yields relative to (18)F-fluoride, with specific activities of 666 ± 51.8 GBq (18 ± 1.4 Ci)/µmol at the end of synthesis and was validated for human use. CONCLUSION: Radiofluorination of iodonium (III) ylides proved to be an efficient radiosynthetic strategy for synthesis of (18)F-labeled radiopharmaceuticals.


Assuntos
Radioisótopos de Flúor/química , Iodo/química , Nitrilas/química , Oniocompostos/química , Piridinas/química , Compostos Radiofarmacêuticos/síntese química , Automação , Elétrons , Humanos , Hidrólise , Oxigênio/química , Tomografia por Emissão de Pósitrons , Piridinas/síntese química , Radioquímica , Compostos Radiofarmacêuticos/química , Temperatura , Fatores de Tempo
10.
Medchemcomm ; 5(4): 432-435, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25431646

RESUMO

The synthesis of fluorine-18 labeled 3-fluoro-5-[(pyridin-3-yl)ethynyl] benzonitrile ([18F]FPEB) for imaging metabotropic glutamate receptor subtype type 5 (mGluR5) was achieved with a commercial continuous-flow microfluidics device. This work represents the first positron emission tomography (PET) radiopharmaceutical that is suitable for human use with this technology. We also describe a validated synthesis of [18F]FPEB with a commercial reactor-based system.

11.
Mol Imaging ; 132014.
Artigo em Inglês | MEDLINE | ID: mdl-25248283

RESUMO

Despite extensive preclinical imaging with radiotracers developed by continuous-flow microfluidics, a positron emission tomographic (PET) radiopharmaceutical has not been reported for human imaging studies by this technology. The goal of this study was to validate the synthesis of the tau radiopharmaceutical 7-(6-fluoropyridin-3-yl)-5H-pyrido[4,3-b]indole ([18F]T807) and perform first-in-human PET scanning enabled by microfluidic flow chemistry. [18F]T807 was synthesized by our modified one-step method and adapted to suit a commercial microfluidic flow chemistry module. For this proof of concept, the flow system was integrated to a GE Tracerlab FXFN unit for high-performance liquid chromatography purification and formulation. Three consecutive productions of [18F]T807 were conducted to validate this radiopharmaceutical. Uncorrected radiochemical yields of 17 ± 1% of crude [18F]T807 (≈ 500 mCi, radiochemical purity 95%) were obtained from the microfluidic device. The crude material was then purified, and > 100 mCi of the final product was obtained in an overall uncorrected radiochemical yield of 5 ± 1% (n  =  3), relative to starting [18F]fluoride (end of bombardment), with high radiochemical purity (≥ 99%) and high specific activities (6 Ci/µmol) in 100 minutes. A clinical research study was carried out with [18F]T807, representing the first reported human imaging study with a radiopharmaceutical prepared by this technology.


Assuntos
Encéfalo/diagnóstico por imagem , Carbolinas/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Adulto , Carbolinas/síntese química , Cromatografia Líquida de Alta Pressão , Humanos , Masculino , Microfluídica/instrumentação , Compostos Radiofarmacêuticos/síntese química
12.
J Labelled Comp Radiopharm ; 56(14): 736-40, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24339014

RESUMO

Fluorine-18 labeled 7-(6-fluoropyridin-3-yl)-5H-pyrido[4,3-b]indole ([(18) F]T807) is a potent and selective agent for imaging paired helical filaments of tau and is among the most promising PET radiopharmaceuticals for this target in early clinical trials. The present study reports a simplified one-step method for the synthesis of [(18) F]T807 that is broadly applicable for routine clinical production using a GE TRACERlab™ FXFN radiosynthesis module. Key facets of our optimized radiosynthesis include development and use of a more soluble protected precursor, tert-butyl 7-(6-nitropyridin-3-yl)-5H-pyrido[4,3-b]indole-5-carboxylate, as well as new HPLC separation conditions that enable a facile one-step synthesis. During the nucleophilic fluorinating reaction with potassium cryptand [(18) F]fluoride (K[(18) F]/K222 ) in DMSO at 130 °C over 10 min the precursor is concurrently deprotected. Formulated [(18) F]T807 was prepared in an uncorrected radiochemical yield of 14 ± 3%, with a specific activity of 216 ± 60 GBq/µmol (5837 ± 1621 mCi/µmol) at the end of synthesis (60 min; n = 3) and validated for human use. This methodology offers the advantage of faster synthesis in fewer steps, with simpler automation that we anticipate will facilitate widespread clinical use of [(18) F]T807.


Assuntos
Carbolinas/síntese química , Radioisótopos de Flúor/química , Marcação por Isótopo/métodos , Compostos Radiofarmacêuticos/síntese química , Tomografia por Emissão de Pósitrons , Proteínas tau/metabolismo
13.
Appl Radiat Isot ; 80: 99-102, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23860127

RESUMO

OBJECTIVES: Often peptides used in synthesis of radiopharmaceutical PET tracers are lipophilic and adhere to the walls of container closure systems (CCS) such that costly peptide and product are not fully recoverable after synthesis occurs. This investigation compares a standard United States Pharmacopeia (USP) Type I borosilicate glass CCS to a cyclic polyolefin copolymer Crystal Zenith(®) (CZ) CCS, for (68)Ga-chloride and (68)Ga-DOTATOC ([(68)Ga] Ga-DOTA-D-Phe1-Tyr3-octreotide) retention in the reaction vial after labeling. METHODS: (68)Gallium labeling of DOTATOC was conducted by adding (68)Ga-chloride, 2M HEPES (4-(2-hydroxyethyl)piperazine-1-ethanesulfonic acid) or 0.75 M sodium acetate, and 1-30 µg of DOTATOC into the CZ or glass CCS. The reaction mixture was heated for 15 min and cooled to room temperature. The crude reaction mixture was then withdrawn via syringe, for final processing. The CCS was then assayed using a dose calibrator to determine the amount of retained (68)Ga-DOTATOC. Statistical significance was assessed using an unpaired Student's t-test. RESULTS: In all experiments (n=72) with various amounts of peptide and different buffering systems, the CZ CCS retained less activity than the glass CCS. Using 2 M HEPES and 15 µg or 30 µg of DOTATOC, the CZ CCS retained approximately 10% less of the labeled DOTATOC compared to the glass CCS (p<0.05). Utilizing either a sodium acetate or a HEPES buffering system with 15 µg or 30 µg of DOTATOC, the CZ CCS retained approximately 2.5% less of the total reaction activity compared to the glass CCS (p<0.05). Product yield was equivalent in glass and CZ CCS under the same reaction conditions. Both the CZ and glass vials showed no retention of (68)Ga-chloride. CONCLUSION: For applications involving the labeling of peptides such as (68)Ga-DOTATOC, the CZ CCS compared to the glass CCS, results in an improved recovery of product.


Assuntos
Compostos de Boro/química , Radioisótopos de Gálio/química , Vidro , Peptídeos/isolamento & purificação , Silicatos/química , Peptídeos/química
14.
Appl Radiat Isot ; 70(10): 2313-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22871433

RESUMO

We report an automated synthesis of [(18)F]-FMISO utilizing a prototype microfluidic radiochemistry module. The instrument allows for production of the tracer with 58%±2% (11 runs) decay corrected yield. Total time of production, including synthesis and purification averages 60 min. Use of the microfluidic platform results in a specific activity of 138.6 GBq/µ mol, which is higher than previously reported for conventional reactors.


Assuntos
Radioisótopos de Flúor/química , Microfluídica , Misonidazol/análogos & derivados , Oxigênio/química , Misonidazol/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA