Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Eur J Radiol ; 85(11): 1956-1962, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27776646

RESUMO

PURPOSE: To compare the predictabilities of postoperative pulmonary function after lobectomy for primary lung cancer among counting method, effective lobar volume, and lobar collapsibility. METHODS: Forty-nine patients who underwent lobectomy for primary lung cancer were enrolled. All patients underwent inspiratory/expiratory CT and pulmonary function tests 2 weeks before surgery and postoperative pulmonary function tests 6-7 months after surgery. Pulmonary function losses (ΔFEV1.0 and ΔVC) were calculated from the pulmonary function tests. Predictive postoperative pulmonary function losses (ppoΔFEV1.0 and ppoΔVC) were calculated using counting method, effective volume, and lobar collapsibility. Correlations and agreements between ΔFEV1.0 and ppoFEV1.0 and those between ΔVC and ppoΔVC were tested among three methods using Spearman's correlation coefficient and Bland-Altman plots. RESULTS: ΔFEV1.0 and ppoΔFEV1.0insp-exp were strongly correlated (r=0.72), whereas ΔFEV1.0 and ppoΔFEV1.0count and ΔFEV1.0 and Pred. ΔFEV1.0eff.vol. were moderately correlated (r=0.50, 0.56). ΔVC and ppoΔVCeff.vol. (r=0.71) were strongly correlated, whereas ΔVC and ppoΔVCcount, and ΔVC and ppoΔVC insp-exp were moderately correlated (r=0.55, 0.42). CONCLUSIONS: Volumetry from inspiratory/expiratory CT data could be useful to predict postoperative pulmonary function after lobectomy for primary lung cancer.


Assuntos
Neoplasias Pulmonares/cirurgia , Pulmão/fisiopatologia , Complicações Pós-Operatórias/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Expiração , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Período Pós-Operatório , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Testes de Função Respiratória/métodos , Testes de Função Respiratória/estatística & dados numéricos
2.
Cardiovasc Intervent Radiol ; 39(2): 227-32, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26122739

RESUMO

PURPOSE: To evaluate the frequency and the predictive factor of each feeding artery on intra-arterial infusion chemotherapy (IAIC) in primary tongue cancer. MATERIALS AND METHODS: We retrospectively evaluated 20 patients who received IAIC for primary tongue cancer. The main and accompanying feeding arteries were identified on super-selective angiography of the branches of the external carotid artery. Tumor diameter, and extension to the contralateral side, tongue extrinsic muscles (TEMs), and lateral mesopharyngeal wall were determined based on magnetic resonance imaging or computed tomography findings. RESULTS: The main feeding artery was the ipsilateral lingual artery (LA) in 15 of the 20 examined tumors and the contralateral LA in the other 5. Ten cancers had only one feeding artery, and multiple feeding arteries were detected in the remaining 10. Tumors >4 cm (n = 9), those with extension to the contralateral side (n = 13), and those with extension to TEMs (n = 15) were supplied by significantly larger numbers of feeding arteries compared to tumors without these features (P = 0.01, 0.049, and 0.02, respectively). The frequency of feeding from the contralateral LA was 64 % (9/14) and 17 % (1/6) in tumors with and without extension to the contralateral side, respectively. Feeding from a facial artery (FA) was not detected in tumors ≤4 cm, while 5 of the 9 (56 %) tumors >4 cm were supplied by a FA (P = 0.01). CONCLUSION: A careful search for feeding arteries is required, especially in large tumors with extension to the contralateral side or to TEMs.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Língua/tratamento farmacológico , Neoplasias da Língua/patologia , Língua/irrigação sanguínea , Língua/patologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Antineoplásicos/administração & dosagem , Tomografia Computadorizada de Feixe Cônico , Meios de Contraste , Feminino , Humanos , Infusões Intra-Arteriais , Iopamidol , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neovascularização Patológica , Estudos Retrospectivos , Resultado do Tratamento
3.
Eur J Radiol ; 84(12): 2654-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26362824

RESUMO

PURPOSE: To compare hybrid iterative reconstruction (HIR) with filtered back projection (FBP) in the volumetry of artificial pure ground-glass nodules (GGNs) with low-dose computed tomography (CT). MATERIALS AND METHODS: Artificial GGNs (10 mm-diameter, 523.6 mm(3), -660 HU) in an anthropomorphic chest phantom were scanned by a 256-row multi-slice CT with three dose levels (10, 30, 100 mAs). Each scan was repeated six times. Each set was reconstructed by FBP and HIR at 0.625-mm thickness. The volumes of artificial GGNs placed at the lung apex and middle lung field of the chest phantom were measured by two observers. Semi-automated measurements were performed by clicking the cursor in the center of GGNs, and manual measurements were performed by tracing GGNs on axial section. Modification of the trace was added on a sagittal or coronal section if necessary. Measurement errors were calculated for both the FBP and HIR at each dose level. We used the Wilcoxon signed rank test to identify any significant difference between the measurement errors of the FBP and HIR. Inter-observer, intra-observer, and inter-scan variabilities were evaluated by Bland Altman analysis with limits of agreements given by 95% confidence intervals. RESULTS: There were significant differences in measurement errors only at the lung apex between FBP and HIR with 10 mAs in both the semi-automated (observer 1, -37% vs. 7.2%; observer 2, -39% vs. 1.9%) and manual methods (observer 1, -29% vs. 7.5%; observer 2, -30% vs. 1.1%), respectively (P<0.05). HIR provided each variability equal to or less than one half of that of FBP at 10 mAs in both methods. In the semi-automated method, the inter-observer and intra-observer variabilities obtained by HIR at 10 mAs were -11% to 17% and -6.7% to 6.7%, whereas those for FBP at 10 mAs were -29% to 30% and -38% to 20%, respectively. The inter-scan variability for FBP at 100 mAs vs. HIR at 10 mAs was -9.5% to 11%, and that for FBP at 100 mAs vs. FBP at 10 mAs was -73% to 32%. In the manual method, the inter-observer and intra-observer variabilities for HIR at 10 mAs were -14% to 22% and -9.8% to 22%, and those for FBP at 10 mAs were -45% to 36% and -31% to 28%, respectively. The inter-scan variability for FBP at 100 mAs vs. HIR at 10 mAs was -7.4% to 23%, and that for FBP at 100 mAs vs. FBP at 10 mAs was -52% to 26%. CONCLUSION: HIR is superior to FBP in the volumetry of artificial pure GGNs at lung apex with low-dose CT.


Assuntos
Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Pulmão , Variações Dependentes do Observador
4.
Jpn J Radiol ; 33(7): 433-6, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26025611

RESUMO

We present a case of mediastinal paraganglioma with radiologic-pathologic correlation. A 48-year-old woman was found incidentally to have a middle mediastinal mass on CT. The mass showed iso-signal intensity compared to that of muscle on T1-weighted images and high signal intensity on T2-weighted images. The lesion showed intermediate intensity on diffusion-weighted imaging, and its apparent diffusion coefficient was 1.72 × 10(-3) mm(2)/s. A contrast-enhanced dynamic study revealed a rapid peak and washout enhancement pattern. (18)F-FDG-PET revealed abnormal uptake in the mediastinal tumor with a maximal standardized uptake value of 7.88. (123)I-meta-iodobenzylguanidine scintigraphy also showed abnormal uptake in the tumor. These findings corresponded to the hypervascularity, rich stroma, low nuclear/cytoplasmic ratio, and nest-forming proliferation of tumor cells with positive neuroendocrine markers.


Assuntos
Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/patologia , Paraganglioma/diagnóstico por imagem , Paraganglioma/patologia , 3-Iodobenzilguanidina , Imagem de Difusão por Ressonância Magnética , Feminino , Fluordesoxiglucose F18 , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
5.
Int J Cardiovasc Imaging ; 31(2): 399-407, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25348658

RESUMO

Iron deficiency and cardiac sympathetic impairment play a role in the worsening of heart failure, and these two conditions may be linked. The present study aimed to clarify the relationship between myocardial iron deficiency, cardiac sympathetic activity, and major adverse cardiac events (MACE) in patients with dilated cardiomyopathy (DCM). Cardiac T2* MRI for iron deficiency and (123)I-Metaiodobenzylguanidine (MIBG) imaging for cardiac sympathetic activity were performed in 46 patients with DCM. Myocardial T2* value (M-T2*) was calculated by fitting signal intensity data for mid-left ventricular septum to a decay curve using 3-Tesla scanner. (123)I-MIBG washout rate (MIBG-WR) was calculated using a polar-map technique with tomographic data. We analyze the ability of M-T2* and MIBG-WR to predict MACE. MIBG-WR and M-T2* were significantly greater in DCM patients with MACE than in patients without MACE. Receiver-operating-characteristics curve analysis showed that the optimal MIBG-WR and M-T2* thresholds of 35 % and 28.1 ms, and the two combination predict MACE with C-statics of 0.69, 0.73, and 0.82, respectively. Patients with MIBG-WR <35 % and M-T2* <28.1 ms had significantly lower event-free rates than those with MIBG-WR ≥35 % or M-T2* ≥28.1 ms (log-rank value = 4.35, p < 0.05). Cox hazard regression analysis showed that χ(2) and the hazard ratio were 3.99 and 2.15 for development of MACE in patients with MIBG-WR ≥35 % or M-T2* ≥28.1 ms (p < 0.05). Iron deficiency, expressed by a high M-T2*, and MIBG-WR were both independent predictors of MACE in patients with DCM. The two combination was a more powerful predictor of MACE than either parameter alone.


Assuntos
3-Iodobenzilguanidina , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Coração/diagnóstico por imagem , Coração/inervação , Deficiências de Ferro , Imagem Cinética por Ressonância Magnética , Miocárdio/metabolismo , Compostos Radiofarmacêuticos , Sistema Nervoso Simpático/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Área Sob a Curva , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/metabolismo , Progressão da Doença , Intervalo Livre de Doença , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Medição de Risco , Fatores de Risco
6.
Acta Radiol ; 56(8): 943-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25168020

RESUMO

BACKGROUND: There has been no comparison of detectability of small lung cancer between general and medical LCD monitors or no comparison of detectability of small lung cancer between solid and part-solid nodules. PURPOSE: To compare the detectabilities of T1a lung cancer on chest radiographs on three LCD monitor types: 2-megapixel (MP) for general purpose (General), 2-MP for medical purpose (Medical), and 3-MP-Medical. MATERIAL AND METHODS: Radiographs from forty patients with T1aN0M0 primary lung cancer (27 solid nodules, 13 part-solid nodules) and 60 patients with no abnormalities on both chest X-ray and computed tomography (CT) were consecutively collected. Five readers assessed 100 cases for each monitor. The observations were analyzed using receiver operating characteristic (ROC) analysis. A jackknife method was used for statistical analysis. A P value of <0.05 was considered significant. RESULTS: The average AUC for all T1a lung cancer nodule detection using the 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.86, 0.89, and 0.89, respectively; there were no significant differences among them. The average AUC for part-solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.77, 0.86, and 0.89, respectively. There were significant differences between the 2-MP-General and 2-MP-Medical LCD monitors (P = 0.043) and between the 2-MP-General and 3-MP-Medical LCD monitors (P = 0.027). There was no significant difference between the 2-MP-Medical and 3-MP-Medical LCD monitors. The average AUC for solid nodule detection using a 2-MP-General, 2-MP-Medical, and 3-MP-Medical LCD monitors were 0.90, 0.90, and 0.88, respectively; there were no significant differences among them. The mean AUC values for all and part-solid nodules of the low-experienced readers were significantly lower than those of the high-experienced readers with the 2 M-GP color LCD monitor (P < 0.05). CONCLUSION: Detectability of part-solid nodules using a general-purpose LCD monitor was significantly lower than those using medical-purpose LCD monitors.


Assuntos
Terminais de Computador , Apresentação de Dados , Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Congenit Heart Dis ; 10(3): 271-80, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25159310

RESUMO

PURPOSE: Right ventricular (RV) failure and ventricular dyssynchrony are strong determinants of prognosis in patients with adult congenital heart disease (ACHD). The aim of this study was to investigate the relationship between interventricular dyssynchrony (IVD) using cine-tagged magnetic resonance imaging (MRI) and RV dysfunction in ACHD patients. MATERIALS AND METHODS: Sixty-seven patients with ACHD (38 with repaired tetralogy of Fallot; 22 with atrial septal defect; seven with ventricular septal defect) underwent tagging MRI. Time curves of myocardial circumferential strains for RV and left ventricular (LV) free walls were delivered from short-axis cine-tagging images. Contraction delay between RV and LV free walls was computed by cross-correlation analysis of the two strain time curves and was defined as the IVD time (msec). RESULTS: IVD was significantly greater for patients with RV ejection fraction (RVEF) <40% (116 ± 58 msec) than for patients with RVEF ≥ 40% (65 ± 54 msec) and was significantly greater for patients with RV systolic pressure ≥ 40 mm Hg (112 ± 59 msec) than for patients with RV systolic pressure <40 mm Hg (49 ± 28 msec). Receiver operating characteristic analysis revealed optimal IVD thresholds for detecting patients with RVEF <40% with C-statistics of 0.76 and patients with RV systolic pressure ≥ 40 mm Hg with C-statistics of 0.81. CONCLUSION: Quantification of IVD was possible using RV and LV strains derived from tagging MRI. IVD, represented as the time difference between LV and RV contractions, correlates with RV dysfunction. IVD may thus offer an indicator for RV failure in ACHD.


Assuntos
Cardiopatias Congênitas/complicações , Cardiopatias/congênito , Cardiopatias/complicações , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Adulto , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
8.
Int Heart J ; 55(6): 512-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25310930

RESUMO

The aims of this study were to quantify the geometrical differences in left ventricular (LV) dyssynchrony in patients with heart failure (HF) using cine-tagged MRI, and to investigate the relationship between dyssynchrony and major adverse cardiac events (MACE) in HF.In 67 patients with HF [mean LV ejection fraction (LVEF), 34%], cardiac MRI using a 3-Tesla scanner was performed. The dyssynchrony time between septal and lateral segments (SL-DT) and between basal and apical segments (BA-DT) was computed by cross-correlation analysis of the strain time-curves from the cine-tagged MRI. After receiving optimal medical treatment, all patients were followed-up for a mean period of 27 months. The primary endpoint was MACE that consisted of cardiac death or HF hospitalization or a left ventricular assist device due to refractory pump failure. Multivariate logistic regression analysis was performed to determine the ability of SL-DT, BA-DT, and HF biomarkers to predict MACE.Multivariate logistic regression analysis showed that the odds ratio to predict MACE was 0.935 for LVEF (P = 0.021), 1.016 for BA-DT (P = 0.026), and 0.971 for systolic blood pressure (P = 0.126).The results show that basal-apical dyssynchrony is an independent predictor of MACE in HF patients.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Esquerda , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio , Estudos Prospectivos
9.
Eur Radiol ; 24(12): 3289-99, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25113649

RESUMO

OBJECTIVES: To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF). METHODS: Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability. RESULTS: CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0%) and PRF (-9.1 ± 2.0%) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv. CONCLUSIONS: 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF. KEY POINTS: 256-slice CT assessment of RV function is highly reproducible in repaired TOF. Pulmonary regurgitation can be evaluated by biventricular systolic volume difference. CT overestimates RV volume and underestimates pulmonary regurgitation, compared with MRI.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores/métodos , Insuficiência da Valva Pulmonar/diagnóstico , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Adulto , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Volume Sistólico , Sístole , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia
11.
Eur J Radiol ; 83(8): 1344-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24856515

RESUMO

PURPOSE: The purpose of this study was to determine the factors that contribute to the differentiation between phyllodes tumors (PTs) and fibroadenomas (FAs) on MR imaging. MATERIALS AND METHODS: This retrospective study included 19 PTs and 18 FAs with ≥ 2 cm diameter. The presence or absence of a capsule and internal septum, the extent of lobulation, and the apparent diffusion coefficient (ADC) values were determined. The presence or absence of a cystic component, the time-intensity curve, and the signal intensity on delayed-phase contrast-enhanced T1WI were also evaluated in 31 patients (16 PTs and 17 FAs) who underwent a contrast-enhanced study. RESULTS: Cystic components were seen in 10 of the 16 PTs (63%) and in 4 of the 17 FAs (24%; P=0.03). The PTs showed strong lobulation more frequently compared to the FAs (14/19 [74%] vs. 7/18 [39%], respectively; P=0.04). Though there was no significant difference, PT tended to be heterogeneous more frequently on the delayed phase of the contrast-enhanced T1WI compared to the FA (11/16 [69%] vs. 7/17 [41%], respectively). No significant difference was found in the other findings. CONCLUSIONS: Although PTs and FAs show similar MR findings, the presence of a cystic component, strong lobulation, and heterogeneity on delayed-phase contrast-enhanced T1WI suggests a PT.


Assuntos
Neoplasias da Mama/diagnóstico , Fibroadenoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tumor Filoide/diagnóstico , Adolescente , Adulto , Neoplasias da Mama/patologia , Meios de Contraste , Diagnóstico Diferencial , Feminino , Fibroadenoma/patologia , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Tumor Filoide/patologia , Estudos Retrospectivos
12.
Acad Radiol ; 21(5): 648-53, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24703478

RESUMO

RATIONALE AND OBJECTIVES: To investigate the effect of dual-bolus contrast media injection (dual-CM) on the accuracy of automated right ventricular (RV) segmentation on coronary computed tomography angiography (CCTA). MATERIALS AND METHODS: A total of 104 patients with suspected and known coronary artery disease underwent 256-slice CCTA with retrospective electrocardiographic (ECG) gating. The patients were divided into 51 patients who underwent single-bolus CM injection (single-CM) and 53 patients who underwent dual-CM. The dual-CM method consisted of an initial bolus of CM followed by an injection of dilute CM with saline (CM:saline, 1:9). Three-dimensional CCTA images were automatically segmented into the RV, left ventricle (LV), and myocardium using commercially available software (Comprehensive Cardiac Analysis; Philips Medical Systems, Cleveland, OH). Prevalence and locations of segmentation errors were compared between single-CM and dual-CM. Segmentation errors were defined as segment deviation of >1 cm from the actual ventricular margin. RESULTS: Prevalence of segmentation errors was significantly lower with dual-CM than with single-CM in the diastolic phase (4/41 vs. 20/41, respectively; P < .01), and there was no difference between the two methods in the systolic phase (2/12 vs. 2/10, respectively). With dual-CM and single-CM, the locations of segmentation errors were mostly the RV wall (4/53 and 18/51, respectively) and secondly the LV wall (2/53 and 9/51, respectively). CONCLUSIONS: Dual-CM improved the accuracy of automated ventricular segmentation using diastolic data from 256-slice CCTA.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Iopamidol/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Direita/diagnóstico por imagem , Idoso , Algoritmos , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Volume Sistólico , Disfunção Ventricular Direita/etiologia
13.
Radiology ; 271(2): 356-64, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24475794

RESUMO

PURPOSE: To develop a method to determine significant stenosis at whole-heart coronary magnetic resonance (MR) angiography and to evaluate the accuracy and reproducibility of this approach. MATERIALS AND METHODS: The institutional review board approved the study, and all participants provided written informed consent. Sixty-two patients who were suspected of having coronary artery disease (CAD) and were scheduled for conventional coronary angiography were included. Coronary MR angiography was performed by using a 1.5-T imager with 32-channel coils. Luminal narrowing was evaluated with quantitative analysis (QA) of coronary MR angiograms on the basis of the signal intensity profile along the vessel. Percentage stenosis with QA of coronary MR angiograms was calculated as [1 - (SI(min)/SI(ref))] × 100, where SI(min) is minimal signal intensity and SI(ref) is corresponding reference signal intensity. Diagnostic performance of QA of coronary MR angiograms for predicting at least a 50% reduction in diameter was evaluated by using quantitative coronary angiography (QCA), with conventional angiography findings serving as the reference standard. Receiver operating characteristic (ROC) analysis, Spearman rank correlation, Bland-Altman analysis, and Cohen κ analysis were used. RESULTS: The areas under the ROC curve in a segment-based analysis for detecting significant CAD were 0.96 (95% confidence interval [CI]: 0.94, 0.98) with QA of coronary MR angiograms and 0.93 (95% CI: 0.88, 0.98) with visual assessment. The correlation coefficients between percentage stenosis with QA of coronary MR angiograms and percentage stenosis with QCA were 0.84 (P < .001), 0.80 (P < .001), and 0.66 (P < .001) in the patient-, vessel-, and segment-based analyses, respectively. CONCLUSION: QA of coronary MR angiograms with use of a signal intensity profile along the vessel permits detection of CAD. This method had a diagnostic performance approximately equal to that of visual analysis of coronary MR angiograms with high inter- and intraobserver reliability, allowing for more objective interpretation of coronary MR angiography findings.


Assuntos
Doença das Coronárias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Angiografia por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
14.
Am J Cardiol ; 113(6): 1024-30, 2014 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-24461766

RESUMO

The aim of this study was to use T2* cardiac magnetic resonance (CMR) imaging to quantify myocardial iron content in patients with heart failure (HF) and to investigate the relation between iron content, cardiac function, and the cause of HF. CMR data were analyzed from 167 patients with nonischemic and 31 with ischemic HF and 50 patients with normal ventricular function. Short-axis T2* imaging was accomplished using 3-T scanner and multiecho gradient-echo sequence. Myocardial T2* value (M-T2*) was calculated by fitting the signal intensity data for the mid-left ventricular (LV) septum to a decay curve. Patients with nonischemic HF were categorized into patients with LV ejection fraction (LVEF) <35% or ≥35%. The relation between nonischemic HF with LVEF <35% and the risk for major adverse cardiac events was analyzed by multivariate logistic regression analysis using M-T2* and HF biomarkers. M-T2* was significantly greater for patients with nonischemic HF (LVEF <35%: 29 ± 7 ms, LVEF ≥35%: 26 ± 5 ms) than for patients with normal LV function (22 ± 3 ms, p <0.0001) or ischemic HF (22 ± 4 ms, p <0.001). The odds ratio was 1.21 for M-T2* (p <0.0001) and 1.0015 for brain natriuretic peptide (p <0.0001) in relation to nonischemic HF with LVEF <35%. Furthermore, this value was 0.96 for systolic blood pressure (p = 0.012) and 1.02 for M-T2* (p = 0.03) in relation to the risk for major adverse cardiac events in patients with nonischemic HF. In conclusion, T2* CMR demonstrated the robust relation between myocardial iron deficiency and nonischemic HF. M-T2* is a biomarker that can predict adverse cardiac function in patients with nonischemic HF.


Assuntos
Insuficiência Cardíaca/diagnóstico , Deficiências de Ferro , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/química , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/metabolismo , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Prognóstico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
15.
Jpn J Radiol ; 32(2): 80-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24408077

RESUMO

PURPOSE: To evaluate the correlation between apparent diffusion coefficient (ADC) and prognosis in head and neck squamous cell carcinoma (HNSCC) treated with radiotherapy. MATERIALS AND METHODS: We retrospectively studied 41 patients (38 male and 3 female, ages 37-85 years) diagnosed with HNSCC (14 oropharynx, 22 hypopharynx, 4 larynx, 1 oral cavity) and treated with radiotherapy, with radiation dose to gross tumor volume over 60 Gy. The association between age, gender, performance status, tumor location, T stage, N stage, stage, dose, overall treatment time, treatment method, adjuvant therapy, or ADC and prognosis was analyzed using a Cox proportional hazard test. RESULTS: ADC calculated with b-values of 300, 500, 750, and 1,000 s/mm(2) (ADC 300-1,000) alone showed a significant correlation with all of the analyses (p = 0.022 for local control, p = 0.0109 for regional control, p = 0.0041 for disease-free survival, and p = 0.0014 for overall survival). ADC calculated with b-values of 0, 100, and 200 s/mm(2) (ADC 0-200) showed a significant correlation with overall survival (p = 0.0012). N stage showed a significant correlation with regional control (p = 0.0241). Performance status showed significant association with local control (p = 0.0459), disease-free survival (p = 0.023), and overall survival (p = 0.0151), respectively. CONCLUSION: ADC is an independent predictor of prognosis in HNSCC treated with radiotherapy.


Assuntos
Água Corporal/metabolismo , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/mortalidade , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/radioterapia , Difusão , Intervalo Livre de Doença , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Modelos de Riscos Proporcionais , Dosagem Radioterapêutica , Estudos Retrospectivos
16.
J Med Chem ; 56(18): 7222-31, 2013 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-23964788

RESUMO

Histone N(ε)-methyl lysine demethylases KDM2/7 have been identified as potential targets for cancer therapies. On the basis of the crystal structure of KDM7B, we designed and prepared a series of hydroxamate analogues bearing an alkyl chain. Enzyme assays revealed that compound 9 potently inhibits KDM2A, KDM7A, and KDM7B, with IC50s of 6.8, 0.2, and 1.2 µM, respectively. While inhibitors of KDM4s did not show any effect on cancer cells tested, the KDM2/7-subfamily inhibitor 9 exerted antiproliferative activity, indicating the potential for KDM2/7 inhibitors as anticancer agents.


Assuntos
Antineoplásicos/farmacologia , Inibidores Enzimáticos/farmacologia , Histona Desmetilases/antagonistas & inibidores , Domínio Catalítico , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Histona Desmetilases/química , Humanos , Concentração Inibidora 50 , Modelos Moleculares
17.
Magn Reson Med Sci ; 12(3): 193-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23857151

RESUMO

PURPOSE: We investigated possible correlations between apparent diffusion coefficient (ADC) values and prognostic factors of breast cancer. METHODS: We retrospectively evaluated 81 patients who underwent magnetic resonance (MR) imaging of the breast and were diagnosed pathologically with invasive ductal carcinoma (IDC) not otherwise specified with invasive foci one cm or larger. We excluded ductal carcinoma in situ and IDC with invasive foci smaller than one cm because small lesions decrease the reliability of signal intensity of diffusion-weighted imaging (DWI). We also excluded special type cancers. We used t-test to compare the mean ADC values of cancers of Stage pT1 (≤2 cm) versus pT2 or 3 (>2 cm), cancers with versus without vascular invasion, axillary lymph node (N)-positive versus N-negative cancers, estrogen receptor (ER)-positive versus ER-negative cancers, and progesterone receptor (PgR)-positive versus PgR-negative cancers. We analyzed correlations between the ADC value with nuclear grade (NG) and human epidermal growth factor receptor 2 (HER2) score by rank test using Spearman's correlation coefficient. RESULTS: The mean ADC value was significantly higher for N-positive (n=28; 0.97 ± 0.20 × 10(-3) mm(2)/s) than N-negative cancers (n=53; 0.87 ± 0.17 × 10(-3) mm(2)/s) (P=0.017); significantly lower for ER-positive (n=63; 0.88 ± 0.15 × 10(-3) mm(2)/s) than ER-negative cancers (n=18; 1.01 ± 0.21 × 10(-3) mm(2)/s) (P=0.005); and significantly lower for PgR-positive (n=47; 0.88 ± 0.16 × 10(-3) mm(2)/s) than PgR-negative cancers (n=34; 0.95 ± 0.18 × 10(-3) mm(2)/s) (P=0.048). Tumor size, vascular invasion, NG, and HER2 status showed no significant correlation with ADC values. CONCLUSION: ADC values were higher for N-positive and ER-negative breast cancers than N-negative and ER-positive cancers.


Assuntos
Algoritmos , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Japão/epidemiologia , Pessoa de Meia-Idade , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Estatística como Assunto
18.
J Nucl Cardiol ; 20(4): 600-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23653269

RESUMO

BACKGROUND: Impairment of cardiac sympathetic activity has various detrimental effects on cardiac function. The purpose was to investigate the relationship between left ventricular (LV) dyssynchrony and cardiac sympathetic activity in non-ischemic heart failure (HF). METHODS: Twenty-seven patients with non-ischemic HF were enrolled. Cardiac sympathetic activity was assessed by heart-to-mediastinum ratio (H/M ratio) on (123)I-Metaiodobenzylguanidine scintigraphy. LV dyssynchrony was assessed by cross-correlation analysis of time curves of myocardial circumferential strains delivered from cine-tagging MR images. Temporal dyssynchrony was defined as contraction delay between septal and lateral segments >110 milliseconds. Spatial dyssynchrony was defined as the negative value of the maximum correlation for the two strain time curves. RESULTS: H/M ratio was significantly lower for patients with spatial dyssynchrony compared to patients without (1.8 ± 0.3 vs 2.1 ± 0.3, P < .05). There was no difference between patients with and without temporal dyssynchrony (2.0 ± 0.2 vs 2.0 ± 0.3). The incidence of spatial dyssynchrony was significantly higher in patients with H/M ratio <2.0 than those whose ratios were ≥2.0 (75% vs 20%, P = .001). There was no difference in the incidence of temporal dyssynchrony between the two groups (17% vs 20%). CONCLUSION: Impairment of cardiac sympathetic activity was found to be associated with spatial dyssynchrony in patients with non-ischemic HF.


Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Sistema Nervoso Simpático/patologia , Adolescente , Adulto , Idoso , Terapia de Ressincronização Cardíaca , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Humanos , Radioisótopos do Iodo , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos , Fatores de Tempo , Adulto Jovem
19.
Radiol Phys Technol ; 6(2): 299-304, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23400447

RESUMO

The detection of ground-glass opacities (GGOs) is an important issue in lung cancer screening with low-dose CT. The iterative reconstruction (IR) technique has the ability to improve the image quality relative to the filtered back projection (FBP) technique with low-dose CT. Our purpose was to investigate the ability to detect GGO in a chest phantom using a low-dose CT and hybrid IR, named iDose. Simulated GGOs in a chest phantom were scanned with 256-section CT at tube current second products of 20, 50, 100, and 200 mAs. Five radiologists visually assessed the detectability of GGOs in the phantom. The contrast-to-noise ratio (CNR) for GGOs was used as an estimate of image quality. Comparison of the detectability and CNR between standard images with 200 mAs-FBP and low-dose images with 20, 50, and 100-mAs FBP/iDose were performed by ANOVA with Dunnett's and Tukey's test. The detectability was significantly lower at 20-mAs FBP/iDose and 50-mAs FBP than that at 200-mAs FBP (p < 0.05). There was no significant difference between 50-mAs iDose and 200-mAs FBP and between 100-mAs iDose/FBP and 200-mAs FBP. The CNR was significantly higher on iDose images than that on FBP images at each mAs value. The CNR at 200-mAs FBP was the same as that at 50-mAs iDose (CNR:1.8). The hybrid IR technique and low-dose CT imaging with 50 mAs enabled noise and to maintain the detectability for GGOs in a chest phantom that is equivalent to the reference acquisitions of 200 mAs with FBP.


Assuntos
Algoritmos , Vidro/química , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Radiografia Torácica/instrumentação
20.
Eur J Radiol ; 82(4): e192-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23265927

RESUMO

PURPOSE: We compared the diagnostic performance of T1ρ and T2 mappings in the evaluation of denatured articular cartilage with osteoarthritis of the knee. MATERIALS AND METHODS: 2D-Sagittal T1ρ and T2 mappings of the knee were obtained from 16 patients before total knee arthroplasty. After surgery, specimens of the femur and tibia were regionally segmented according to a 5-point scale of the severity of denaturalization. The T1ρ and T2 values in the full thickness of the articular cartilage in each region were measured by two observers. The two mappings were compared for their ability to differentiate between normal and denatured articular cartilage and also for their usefulness in grading the severity of the denaturalization using the area under receiver operating characteristic curves (Az). A p<0.05 was considered significant for each analysis. RESULTS: The T1ρ mapping showed a significantly higher Az value than the T2 mapping for the differentiation between normal and denatured articular cartilage (p<0.05). Regarding the assessment of the severity of denaturalization, T1ρ mapping could differentiate between normal and mild denaturalization (p<0.05), but T2 mapping could not. However, there were no significant differences between the two mappings in the discrimination of mild versus moderate denaturalization or of moderate versus severe denaturalization. The two observers showed good agreement in the results (intraclass correlation coefficient=0.81 for T1ρ and 0.92 for T2). CONCLUSION: T1ρ mapping is superior to T2 mapping for the evaluation of denatured articular cartilage with osteoarthritis of the knee.


Assuntos
Artroplastia do Joelho , Cartilagem Articular/patologia , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Estudos Prospectivos , Curva ROC , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA