Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Korean J Intern Med ; 37(3): 631-638, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35124940

RESUMO

BACKGROUND/AIMS: Hip fracture and acute exacerbation of chronic obstructive pulmonary disease (AE-COPD) could increase mortality in patients with COPD. There are no data on the relationship between AE-COPD and hip fracture, which may significantly affect the prognosis of patients with COPD. Therefore, we conducted this study to determine the effects of AE-COPD on hip fractures in patients with COPD. METHODS: This retrospective, nested, case-control study included 253,471 patients with COPD (≥ 40 years of age) identified from the Korea National Health Insurance Service-National Health Screening Cohort (NHIS-HEALS) from 2002 to 2015. Among 176,598 patients with COPD, 1,415 patients with hip fractures were identified. Each case was matched to one control for age (within 10 years), sex, and year of COPD diagnosis. We estimated the adjusted odds ratios (aORs) and 95% confidence intervals (CIs) for hip fractures associated with AE-COPD using conditional logistic regression analysis, adjusting for underlying diseases and smoking history. RESULTS: In patients with AE-COPD, the risk of hip fracture was 2.50 times higher, regardless of systemic corticosteroid use and underlying disease (aOR, 2.50; 95% CI, 1.67 to 3.75). The risk of hip fracture increased if there was one episode of AE in the year before hip fractures (aOR, 2.25; 95% CI, 1.66 to 3.05). Moreover, the risk of hip fracture also increased in patients with more than two episodes of AE the year before hip fractures (aOR, 2.57; 95% CI, 1.61 to 4.10). CONCLUSION: AE-COPD increases the risk of hip fracture regardless of underlying diseases, including osteoporosis, and treatment with systemic corticosteroids.


Assuntos
Fraturas do Quadril , Doença Pulmonar Obstrutiva Crônica , Estudos de Casos e Controles , Criança , Fraturas do Quadril/diagnóstico , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/etiologia , Humanos , Programas Nacionais de Saúde , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Estudos Retrospectivos , Fatores de Risco
3.
Spine (Phila Pa 1976) ; 47(10): 745-753, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-35102120

RESUMO

STUDY DESIGN: Retrospective study. OBJECTIVE: To evaluate the absolute value of L4 trabecular region-of-interest (t-ROI) computed tomography (CT) attenuation, which can predict pedicle screw loosening, and determine the changes in value according to number of fused levels and sagittal balance in patients undergoing lumbar fusion surgery. SUMMARY OF BACKGROUND DATA: Although osteoporosis was not diagnosed in spinal dual x-ray absorptiometry preoperatively, we encountered several cases of screw loosening within 1 year of lumbar fusion surgery. METHODS: We enrolled 478 patients and analyzed factors related to screw loosening. We evaluated the association between L4 t-ROI CT attenuation and screw loosening and determined the best cutoff value of t L4 t-ROI CT attenuation for predicting screw loosening. RESULTS: The number of fused levels, postoperative C7-S1 sagittal vertical axis (SVA), and L4 t-ROI CT attenuation were independently correlated with screw loosening. According to number of fused level and postoperative C7-T1 SVA (≥36.9 mm or <36.9 mm), in patients with one-level fusion and C7-S1 SVA less than 36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 106.5 Hounsfield unit (HU). L4 t-ROI attenuation did not change until two-level fusions. In patients with three-level fusions and C7-S1 SVA less than 36.9 mm, the optimal cutoff point of the L4 t-ROI CT attenuation predicting screw loosening was 159.0 HU. The optimal cutoff point of L4 t-ROI CT attenuation in patients with three-level fusions and C7-S1 SVA more than or equal to 36.9 mm was 191.0 HU. CONCLUSION: L4 t-ROI CT attenuation value considering number of fused levels and sagittal balance is an accurate measurement method to predict screw loosening. Spine surgeons should be aware of the L4 t-ROI attenuation before surgery to improve the fusion rate and reduce instrument-related complications of lumbar spine surgery in osteoporotic patients. LEVEL OF EVIDENCE: 3.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Região Lombossacral , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X
4.
PLoS One ; 16(7): e0254586, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34288972

RESUMO

In this paper, we propose an automatic cell counting framework for stimulated Raman scattering (SRS) images, which can assist tumor tissue characteristic analysis, cancer diagnosis, and surgery planning processes. SRS microscopy has promoted tumor diagnosis and surgery by mapping lipids and proteins from fresh specimens and conducting a fast disclose of fundamental diagnostic hallmarks of tumors with a high resolution. However, cell counting from label-free SRS images has been challenging due to the limited contrast of cells and tissue, along with the heterogeneity of tissue morphology and biochemical compositions. To this end, a deep learning-based cell counting scheme is proposed by modifying and applying U-Net, an effective medical image semantic segmentation model that uses a small number of training samples. The distance transform and watershed segmentation algorithms are also implemented to yield the cell instance segmentation and cell counting results. By performing cell counting on SRS images of real human brain tumor specimens, promising cell counting results are obtained with > 98% of area under the curve (AUC) and R = 0.97 in terms of cell counting correlation between SRS and histological images with hematoxylin and eosin (H&E) staining. The proposed cell counting scheme illustrates the possibility and potential of performing cell counting automatically in near real time and encourages the study of applying deep learning techniques in biomedical and pathological image analyses.


Assuntos
Neoplasias Encefálicas/patologia , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Microscopia , Análise Espectral Raman , Humanos
5.
Int J Med Sci ; 18(4): 1039-1050, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33456362

RESUMO

Objective : This network meta-analysis (NMA) aimed to determine the relative efficacy and safety of pharmacological strategies used to mitigate haemodynamic instability by intubation for general anaesthesia in hypertensive parturient women undergoing caesarean section. Methods : We considered randomised controlled studies comparing the effects of pharmacological strategies used to alleviate haemodynamic instability during intubation in parturient women with hypertensive disorders of pregnancy. The primary endpoints were maximum blood pressure and heart rate after intubation, and secondary endpoints were the Apgar scores at 1 and 5 min. NMA allowed us to combine direct and indirect comparisons between strategies. Results : Twelve studies evaluating nine pharmacological strategies in 619 patients were included. According to the surface under the cumulative ranking curve, the maximal mean arterial pressure was lowest for high-dose remifentanil (99.4%) followed by nitroglycerin (73.6%) and labetalol (60.9%). The maximal heart rate was lowest for labetalol (99.9%) followed by high dose of remifentanil (81.2%) and fentanyl (61.6%). Apgar score at 1 min was higher with low-dose than with high-dose remifentanil (mean difference, 0.726; 95% confidence interval, 0.056 to 1.396; I2=0.0%). Conclusions : High-dose remifentanil produces minimum blood pressure changes, while labetalol is most effective in maintaining normal heart rate in parturient women with hypertensive disorders of pregnancy during caesarean section under general anaesthesia.


Assuntos
Anestesia Geral/efeitos adversos , Anti-Hipertensivos/administração & dosagem , Hipertensão Induzida pela Gravidez/tratamento farmacológico , Complicações Intraoperatórias/prevenção & controle , Intubação Intratraqueal/efeitos adversos , Índice de Apgar , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial , Cesárea/efeitos adversos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Hipertensão Induzida pela Gravidez/fisiopatologia , Recém-Nascido , Cuidados Intraoperatórios/métodos , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/fisiopatologia , Labetalol/administração & dosagem , Metanálise em Rede , Nitroglicerina/administração & dosagem , Gravidez , Ensaios Clínicos Controlados Aleatórios como Assunto , Remifentanil/administração & dosagem , Resultado do Tratamento
6.
Spine (Phila Pa 1976) ; 46(3): 175-183, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33065695

RESUMO

STUDY DESIGN: Retrospective study. OBJECTIVE: The aim of this study was to evaluate the usefulness of computed tomography (CT) attenuation in defining trabecular region-of-interest (t-ROI) at lumbar vertebral body in the assessment of osteoporotic compression fracture (OCF) compared to spinal dual x-ray absorptiometry (DXA). SUMMARY OF BACKGROUND DATA: Even though osteoporosis was not diagnosed in the bone mineral density measurement using DXA, we often experienced cases where the screw was weakly inserted due to low bone quality during screw insertion. METHODS: A total of 188 patients who met the inclusion criteria were enrolled. We determined best cutoff value of the simple t-ROI attenuation at the most relevant level for predicting OCF. We assessed correlations between the simple t-ROI attenuation at the most relevant level and OCF rate, and investigate the association between the number of compression fracture and simple t-ROI attenuation at the most relevant level. RESULTS: L4 ROI attenuation is the most accurate measurement for predicting osteoporotic compression fracture with an area under the curve of 0.798. The optimal cutoff point of L4 ROI attenuation was measured at 90.5 HU with 88.8% and 60.6% sensitivity and specificity, respectively. L4 ROI attenuation was significantly correlated with the osteoporotic compression fracture rate (r = -0.545, P < 0.001). The number of compression fracture (coefficient of determination R2 = 0.286; P < 0.001) was independently correlated with L4 ROI attenuation. CONCLUSION: Simple t-ROI computed tomography attenuation is an accurate measurement tool in predicting OCF compared to DXA T-score. The value of L4 t-ROI attenuation is the most relevant measurement for predicting osteoporotic compression fracture, is an alternative to DXA, and can predict the number and rate of compression fractures. Spine surgeons should be aware of L4 t-ROI attenuation to make successful fusion in spine surgery for elderly patients group.Level of Evidence: 3.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Região Lombossacral/diagnóstico por imagem , Fraturas por Osteoporose/diagnóstico , Tomografia Computadorizada por Raios X , Absorciometria de Fóton/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Fraturas por Compressão , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/diagnóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral
7.
Micromachines (Basel) ; 11(12)2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-33265986

RESUMO

In this paper, an approach to determine the thermal impedance of a multi-chip silicon carbide (SiC) power module is proposed, by fusing optical measurement and multi-physics simulations. The tested power module consists of four parallel SiC metal-oxide semiconductor field-effect transistors (MOSFETs) and four parallel SiC Schottky barrier diodes. This study mainly relies on junction temperature measurements performed using fiber optic temperature sensors instead of temperature-sensitive electrical parameters (TESPs). However, the fiber optics provide a relatively slow response compared to other available TSEP measurement methods and cannot detect fast responses. Therefore, the region corresponding to undetected signals is estimated via multi-physics simulations of the power module. This method provides a compensated cooling curve. We analyze the thermal resistance using network identification by deconvolution (NID). The estimated thermal resistance is compared to that obtained via a conventional method, and the difference is 3.8%. The proposed fusion method is accurate and reliable and does not require additional circuits or calibrations.

8.
J Korean Neurosurg Soc ; 63(1): 45-55, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31916426

RESUMO

OBJECTIVE: Fibrin sealants have been used for hemostasis, sealant for cerebrospinal fluid leakage, and adhesive barrier in neurosurgery. Further, as its clinical use and role of an effective drug delivery vehicle have been proposed. This study was performed to measure antibacterial activity and continuous local antibiotic release from different concentrations of vancomycin-impregnated fibrin sealant in vitro. METHODS: Antibacterial activity was investigated by disk diffusion test by measuring the diameter of the growth inhibition zone of bacteria (methicillin-resistant Staphylococcus aureus, ATCC29213) from vancomycin-embedded fibrin sealant disc diluted at five different concentrations (C1-C5; 8.33, 4.167, 0.83, 0.083, and 0.0083 mg/disc, respectively). Continuous and conditioned release of vancomycin concentration (for 2 weeks and for 5 days, respectively) were also measured using high-performance liquid chromatography (HPLC) method. To mimic the physiologic wound conditions with in vitro, conditioned vancomycin release in phosphate buffer solution (PBS) was measured and replaced PBS for five consecutive days, half a day or completely daily. RESULTS: In the disk diffusion test, the mean diameters of bacterial inhibition zone were 2.54±0.07 cm, 2.61±0.12 cm, and 2.13±0.15 cm (C1, C2, and C3 respectively) but 1.67±0.06 cm and 1.23±0.15 cm in C4 and C5, respectively. Continuous elution test elicited the peak release of vancomycin from the fibrin sealant at 48 hours, with continued release until 2 weeks. However, conditioned vancomycin release decreased to half or more on day 2, however, the sustainable release was measured over the therapeutic dose (10-20 µg/mL) for 5 days and 4 days in assays of half and total exchange of PBS. CONCLUSION: This study suggests that fibrin sealant can provide an efficient vehicle for antibiotic drug release in a wide range of neurosurgical procedures and the safe and effective therapeutic dose will be at the concentration embedded of 4.167 mg/disc or more of vancomycin.

9.
Korean J Intern Med ; 35(1): 133-141, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30962409

RESUMO

BACKGROUND/AIMS: There is insufficient quality data to recommend the use of herbs for the treatment of acute bronchitis. Small number of randomized trials of plant extracts for this purpose were determined to be low quality and there are concerns for the safety. HL301 is a combined product of seven medicinal plants. In the present study, we tried to evaluate the efficacy and safety of HL301 for the treatment of acute bronchitis with a randomized, double-blind, placebo-controlled, multicenter trial design. METHODS: A total of 166 patients with acute bronchitis were randomized to receive placebo or HL301 (600 mg/day) for 7 days. The primary endpoint was change in bronchitis severity score (BSS) from baseline visit (visit 2) to the end of treatment (visit 3). Other efficacy variables were the change of each component of the BSS (cough, sputum, dyspnea, chest pain, and crackle) with treatment, response rate, improvement rate, satisfaction rate and number of rescue medications taken. RESULTS: Changes in the BSS from visit 2 to visit 3 were higher in the HL301 group than in the placebo group both in the full analysis set (4.57 ± 1.82 vs. 3.15 ± 3.08, p < 0.01) and in the per protocol set (4.62 ± 1.81 vs. 3.30 ± 3.03, p < 0.01). Four BSS components (cough, sputum, dyspnea, and chest pain) improved more with HL301 treatment than with placebo treatment. Participants treated with HL301 showed higher response, improvement, and satisfaction rates and less use of rescue medication than the placebo group. CONCLUSION: HL301 (600 mg/day) was effective and safe for symptomatic treatment of acute bronchitis.


Assuntos
Bronquite , Fitoterapia , Doença Aguda , Bronquite/diagnóstico , Bronquite/tratamento farmacológico , Método Duplo-Cego , Humanos , Extratos Vegetais/efeitos adversos , Resultado do Tratamento
10.
Data Brief ; 28: 104852, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31871993

RESUMO

This article presents dataset of network meta-analysis (NMA) and systemic review, entitled, Comparison of supraglottic airway devices in laparoscopic surgeries: A network meta-analysis Yoon SW et al., 2019. The data tables demonstrate numeric values for endpoints: oropharyngeal leak pressure (OLP) before and after pneumoperitoneum, peak inspiratory pressure (PIP) before and after pneumoperitoneum, and gastric tube insertion success rate for each supraglottic airway device (SAD). All relevant randomized controlled trials published up to 31 March 2018 were collected from MEDLINE, EMBASE, Web of Science, Cochrane Central Register of Controlled Trials (CENTRAL), and Google Scholar databases. 26 studies with a total of 2142 patients that included eight different SADs were included. The data described in this article are available as a supplementary file.

11.
Medicine (Baltimore) ; 98(51): e18454, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31861021

RESUMO

BACKGROUND: Hypertensive disorders of pregnancy are major health issues affecting mothers and infants. General anesthesia is inevitable for certain mothers with these conditions and they may exhibit pronounced hemodynamic instability, especially during induction and airway manipulation. The aims of this study are to combine direct and indirect comparisons of the efficacies of different medications used in attenuating reflex hemodynamic responses and generate intervention ranking by network meta-analysis (NMA). METHODS: A systematic and comprehensive search will be performed using MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials (CENTRAL), and Google Scholar databases, beginning from their inceptions to November 2019. Only randomized clinical trials evaluating the efficacy and safety of pharmacologic interventions for preventing hemodynamic changes after intubation in parturient women with hypertensive disorders of pregnancy will be included. The primary endpoints will be maximal mean arterial pressure (MAP) and maximal heart rate after intubation. Maximal systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and maternal/fetal blood gas analysis, as well as safety issues, including Apgar score at 1 minute and 5 minutes after delivery, will be also assessed.We will conduct both pairwise meta-analysis and network meta-analysis. We will use surface under the cumulative ranking curve (SUCRA) values and rankograms to present the hierarchy of pharmacologic interventions. A comparison-adjusted funnel plot will be used to assess the presence of small-study effects. The quality of the studies included will be assessed using the risk of bias tool 2.0. All statistical analyses will be performed using Stata SE, version 15.0 (StataCorp, College Station, TX). RESULTS: The results of this systematic review and NMA will be published in a peer-reviewed journal. CONCLUSION: This NMA will enable us to determine the order of effectiveness and safety of pharmacological interventions used in attenuating hemodynamic responses for mothers with hypertensive disorders of pregnancy. TRIAL REGISTRATION NUMBER: CRD42019136067.


Assuntos
Fármacos Cardiovasculares/uso terapêutico , Hipertensão Induzida pela Gravidez/prevenção & controle , Intubação Intratraqueal/efeitos adversos , Feminino , Humanos , Metanálise como Assunto , Gravidez , Revisões Sistemáticas como Assunto
12.
Acute Crit Care ; 34(1): 30-37, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31723902

RESUMO

BACKGROUND: The 2016 Society of Critical Care Medicine (SCCM)/European Society of Intensive Care Medicine (ESICM) task force for Sepsis-3 devised new definitions for sepsis, sepsis with organ dysfunction and septic shock. Although Sepsis-3 was data-driven, evidence-based approach, East Asian descents comprised minor portions of the project population. METHODS: We selected Korean participants from the fever and antipyretics in critically ill patients evaluation (FACE) study, a joint study between Korea and Japan. We calculated the concordance rates for sepsis diagnosis between Sepsis-2 and Sepsis-3 criteria and evaluated mortality rates of sepsis, sepsis with organ dysfunction, and septic shock by Sepsis-3 criteria using the selected data. RESULTS: Korean participants of the FACE study were 913 (383 with sepsis and 530 without sepsis by Sepsis-2 criteria). The concordance rate for sepsis diagnosis between Sepsis-2 and Sepsis-3 criteria was 55.4%. The intensive care unit (ICU) and 28-day mortality rates of sepsis, sepsis with organ dysfunction, and septic shock patients according to Sepsis-3 criteria were 26.2% and 31.0%, 27.5% and 32.5%, and 40.8% and 43.4%, respectively. The quick Sequential Organ Failure Assessment (qSOFA) was inferior not only to SOFA but also to systemic inflammatory response syndrome (SIRS) for predicting ICU and 28-day mortality. CONCLUSIONS: The concordance rates for sepsis diagnosis between Sepsis-2 and Sepsis-3 criteria were low. Mortality rate for septic shock in Koreans was consistent with estimates made by the 2016 SCCM/ESICM task force. SOFA and SIRS were better than qSOFA for predicting ICU and 28-day mortality in Korean ICU patients.

14.
PLoS One ; 14(9): e0221788, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31483820

RESUMO

BACKGROUND: Severe centrum semiovale perivascular spaces (CSO-PVSs) are associated with the onset of brain atrophy and dementia. This study explored the relationship between severity of CSO-PVS and development of subdural fluid (SDF) in patients with mild traumatic brain injury (TBI), with the aim of investigating independent radiological risk factors for development of SDF. METHODS: The study cohort comprised 222 patients with a mean age of 51 years (64.0% men) who presented with mild TBI from January 2013 to November 2016. In this study, mild TBI was defined as a Glasgow Coma Scale (GCS) of ≥ 13, Post-Traumatic Amnesia (PTA) of <1 day, and Loss of Consciousness (LOC) of <30 minutes. The severity of CSO-PVS was categorized as low or high-degree. RESULTS: Among the 222 enrolled patients, 38 (17.1%) and 90 (40.5%) had high-degree PVS in the basal ganglia (BG) and centrum semiovale, respectively. Compared with patients who did not develop SDF, the mean age of patients who developed SDF was significantly higher (47.41 years versus 60.33 years, P < 0.0001). The incidence of de novo SDF was significantly higher in men than in women (77.8% versus 59.5%, P = 0.0151). Patients who showed SDF on brain computed tomography at admission more frequently developed de novo SDF (68.5% versus 38.1%, P < 0.0001). In multivariate logistic regression analysis of risk factors, high-degree CSO-PVS, male sex, initial SDF on admission, and old age were independently associated with development of de novo SDF after mild TBI. In Cox proportional hazards models of risk factors for SDF-development free survival rate, high-degree CSO-PVS, old age, and initial subdural hemorrhage showed statistically significant differences. CONCLUSIONS: Our study might help neurosurgeons determine the frequency of brain CT or the duration of follow-up for patients who present with mild TBI with high-degree CSO-PVS.


Assuntos
Lesões Encefálicas Traumáticas/patologia , Substância Branca/patologia , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Substância Branca/diagnóstico por imagem
15.
Sensors (Basel) ; 19(11)2019 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-31195620

RESUMO

Human hand gestures are a widely accepted form of real-time input for devices providing a human-machine interface. However, hand gestures have limitations in terms of effectively conveying the complexity and diversity of human intentions. This study attempted to address these limitations by proposing a multi-modal input device, based on the observation that each application program requires different user intentions (and demanding functions) and the machine already acknowledges the running application. When the running application changes, the same gesture now offers a new function required in the new application, and thus, we can greatly reduce the number and complexity of required hand gestures. As a simple wearable sensor, we employ one miniature wireless three-axis gyroscope, the data of which are processed by correlation analysis with normalized covariance for continuous gesture recognition. Recognition accuracy is improved by considering both gesture patterns and signal strength and by incorporating a learning mode. In our system, six unit hand gestures successfully provide most functions offered by multiple input devices. The characteristics of our approach are automatically adjusted by acknowledging the application programs or learning user preferences. In three application programs, the approach shows good accuracy (90-96%), which is very promising in terms of designing a unified solution. Furthermore, the accuracy reaches 100% as the users become more familiar with the system.


Assuntos
Técnicas Biossensoriais , Gestos , Mãos/fisiologia , Algoritmos , Humanos , Reconhecimento Automatizado de Padrão , Interface Usuário-Computador , Dispositivos Eletrônicos Vestíveis
16.
J Clin Anesth ; 55: 52-66, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30597453

RESUMO

STUDY OBJECTIVE: To review all randomized controlled trials (RCTs) on supraglottic airway devices (SADs) used in laparoscopy and compare their oropharyngeal leak pressure (OLP) and peak inspiratory pressure (PIP) before and after pneumoperitoneum, and success rate of gastric tube insertion rate. DESIGN: Systematic review and network meta-analysis of RCTs. SETTING: Laparoscopic surgeries using SADs. PATIENTS: We searched MEDLINE, EMBASE, Web of Science, Cochrane Central Register of Controlled Trials, and Google Scholar databases to detect all relevant RCTs on SADs for laparoscopic surgery published until March 2018. INTERVENTIONS: Use of different SADs. MEASUREMENTS: The primary endpoint was OLP before and after pneumoperitoneum. The secondary endpoints were PIP before and after pneumoperitoneum and gastric tube insertion success rate. MAIN RESULTS: Twenty-six studies involving 2142 patients with eight different SADs were evaluated. According to surface under the cumulative ranking curve value, the OLP before pneumoperitoneum was the highest in Ambu AuraGain (95.7%), followed by Laryngeal Mask Airway ProSeal (77.3%) and Streamlined Liner of the Pharynx Airway (75.6%); after pneumoperitoneum, the pressure was the highest in i-gel (95.8%). PIP was the highest in Ambu AuraGain (80.9%) before pneumoperitoneum and i-gel (69.4%) after pneumoperitoneum. CONCLUSION: Although all SADs available were not evaluated, and further studies are needed to establish our results, OLP was the highest in Ambu AuraGain before pneumoperitoneum and i-gel after pneumoperitoneum.


Assuntos
Anestesia Geral/instrumentação , Laparoscopia/instrumentação , Máscaras Laríngeas , Pressão do Ar , Anestesia Geral/métodos , Laparoscopia/métodos , Metanálise em Rede , Orofaringe , Pneumoperitônio Artificial , Ensaios Clínicos Controlados Aleatórios como Assunto , Testes de Função Respiratória
17.
J Cerebrovasc Endovasc Neurosurg ; 20(2): 112-119, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30370245

RESUMO

OBJECTIVE: Cerebral microbleeds (CMBs) are known as the neuroimaging markers of risk in stroke and dementia. Many studies on CMBs in elderly patients with hemorrhagic or ischemic stroke have been reported; however, reports on CMBs in young populations with intracerebral hemorrhage (ICH) are lacking. MATERIALS AND METHODS: A total of 272 patients aged 18-54 years presented to our hospital with ICH between December 2009 and August 2017. Among these, CMB presence, count, and topography with respect to ICH were evaluated on magnetic resonance imaging (MRI) gradient echo images (GREs). We also evaluated the prevalence and risk factors of CMBs. RESULTS: Among 272 patients, only 66 underwent GRE T2-weighted MRI. CMBs were detected in 40 patients (61%), with 29 (73%) being of the multifocal type. Among the 219 CMBs, 150 (68.5%) were of the deep type and 69 (31.5%) of the lobar type. CMB prevalence was higher in men. In multivariate logistic regression analysis, history of hypertension (adjusted odds ratio [aOR], 4.048; 95% confidence interval [CI], 1.14-14.32; p = 0.030), and male sex (aOR, 4.233; 95% CI, 1.09-16.48; p = 0.037) were independently associated with CMBs. CONCLUSION: In young patients who presented with spontaneous ICH, CMBs were highly prevalent in 61% of patients and strongly associated with history of hypertension and male sex.

18.
Clin Exp Otorhinolaryngol ; 11(4): 281-287, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29764011

RESUMO

OBJECTIVES: Regenerative treatment using stem cells may serve as treatment option for empty nose syndrome (ENS), which is caused by the lack of turbinate tissue and deranged nervous system in the nasal cavity. We aimed to assess the efficacy and safety of the autologous stromal vascular fraction (SVF) in the treatment of ENS. METHODS: In this prospective observational clinical study, we enrolled 10 ENS patients who volunteered to undergo treatment of ENS through the injection of autologous SVF. Data, including demographic data, pre- and postoperative Sino-Nasal Outcome Test-25 (SNOT-25) scores, overall patient satisfaction, and postoperative complications, were prospectively collected. Nasal secretion was assessed using the polyurethane foam absorption method, and the levels of biological markers were analyzed in both ENS group and control group using enzyme-linked immunosorbent assay. The SVF extracted from abdominal fat was diluted and injected into both inferior turbinates. RESULTS: Among the 10 initial patients, one was excluded from the study. Subjective satisfaction was rated as "much improved" in two and "no change" in seven. Among the improved patients, the mean preinjection SNOT-25 score was 55.0 and the score at 6 months after injection was 19.5. However, the average SNOT-25 score of nine participants at 6 months after injection (mean±standard deviation, 62.4±35.8) did not differ significantly from the baseline SNOT25 score (70.1±24.7, P>0.05, respectively). Among the various inflammatory markers assessed, the levels of interleukin (IL)-1ß, IL-8, and calcitonin gene-related peptide were significantly higher in ENS patients. Compared with preinjection secretion level, the nasal secretions from SVF-treated patients showed decreased expressions of IL-1ß and IL-8 after injection. CONCLUSION: Although SVF treatment appears to decrease the inflammatory cytokine levels in the nasal mucosa, a single SVF injection was not effective in terms of symptom improvement and patient satisfaction. Further trials are needed to identify a more practical and useful regenerative treatment modality for patients with ENS.

19.
Dig Endosc ; 30(5): 580-591, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29526045

RESUMO

BACKGROUND AND AIM: Previous randomized controlled trials have reported conflicting findings comparing propofol combination therapy (PCT) with propofol monotherapy (PMT) for sedation of patients undergoing gastrointestinal endoscopy. Therefore, a systematic review was carried out to compare the efficacy and safety of PCT and PMT in such patients. METHODS: We searched MEDLINE, EMBASE and CENTRAL databases to identify all randomized controlled trials that compared the efficacy and safety of PCT and PMT for sedation of patients undergoing gastrointestinal endoscopy. Primary endpoints were incidence of respiratory complications, hypotension and arrhythmia, dose of propofol used, and recovery time. Procedure duration and the satisfaction of patients and doctors were also evaluated. RESULTS: A total of 2250 patients from 22 studies were included in the final analysis. The combined analysis did not show any difference between PCT and PMT in the incidence of respiratory complications (risk ratio [RR], 0.80; 95% CI, 0.52 to 1.23; I2 = 58.34%), hypotension (RR, 1.06; 95% CI, 0.63 to 1.78; I2 = 72.13%), arrhythmia (RR,1.40; 95% CI, 0.74 to 2.64; I2 = 43.71%), recovery time (standardized mean difference [SMD], 0.16; 95% CI, -0.49 to 0.81; I2 = 95.9%), procedure duration (SMD, 0.04; 95% CI, -0.05 to 0.14; I2 = 0.0%), patient satisfaction (SMD, 0.13; 95% CI, -0.26 to 0.52; I2 = 89.63%) or doctor satisfaction (SMD, 0.01; 95% CI, -0.15 to 0.17; I2 = 0.00%). However, the dose of propofol used was significantly lower in PCT than in PMT (SMD, -1.38; 95% CI, -1.99 to -0.77; I2 = 97.70%). CONCLUSION: PCT showed comparable efficacy and safety to PMT with respect to respiratory complications, hypotension and arrhythmia, recovery time, procedure duration, patient satisfaction, and doctor satisfaction. However, the average dose of propofol used was higher in PMT.


Assuntos
Sedação Consciente/métodos , Quimioterapia Combinada/métodos , Endoscopia Gastrointestinal , Hipnóticos e Sedativos/administração & dosagem , Propofol/administração & dosagem , Quimioterapia Combinada/efeitos adversos , Humanos , Hipnóticos e Sedativos/efeitos adversos , Propofol/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
20.
Asia Pac Allergy ; 6(3): 187-91, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27489792

RESUMO

Allergic bronchopulmonary aspergillosis (ABPA) is a pulmonary disease with small prevalence. Exposure to aspergillus mold causes immunologic hypersensitivity and may cause ranges of symptoms from minimal to detrimental outcomes. Diagnosing and treating the disease before the development of bronchiectasis may save the patient from poor outcomes. This report presents a case of recurrent ABPA without any symptom of asthma, which impeded the correct diagnosis even after numerous hospitalizations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA