Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Mol Genet Metab ; 122(1-2): 126-134, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28641925

RESUMO

GNE myopathy is a rare, autosomal recessive, inborn error of sialic acid metabolism, caused by mutations in GNE, the gene encoding UDP-N-acetyl-glucosamine-2-epimerase/N-acetylmannosamine kinase. The disease manifests as an adult-onset myopathy characterized by progressive skeletal muscle weakness and atrophy. There is no medical therapy available for this debilitating disease. Hyposialylation of muscle glycoproteins likely contributes to the pathophysiology of this disease. N-acetyl-D-mannosamine (ManNAc), an uncharged monosaccharide and the first committed precursor in the sialic acid biosynthetic pathway, is a therapeutic candidate that prevents muscle weakness in the mouse model of GNE myopathy. We conducted a first-in-human, randomized, placebo-controlled, double-blind, single-ascending dose study to evaluate safety and pharmacokinetics of ManNAc in GNE myopathy subjects. Single doses of 3 and 6g of oral ManNAc were safe and well tolerated; 10g was associated with diarrhea likely due to unabsorbed ManNAc. Oral ManNAc was absorbed rapidly and exhibited a short half-life (~2.4h). Following administration of a single dose of ManNAc, there was a significant and sustained increase in plasma unconjugated free sialic acid (Neu5Ac) (Tmax of 8-11h). Neu5Ac levels remained above baseline 48h post-dose in subjects who received a dose of 6 or 10g. Given that Neu5Ac is known to have a short half-life, the prolonged elevation of Neu5Ac after a single dose of ManNAc suggests that intracellular biosynthesis of sialic acid was restored in subjects with GNE myopathy, including those homozygous for mutations in the kinase domain. Simulated plasma concentration-time profiles support a dosing regimen of 6g twice daily for future clinical trials.


Assuntos
Miopatias Distais/tratamento farmacológico , Hexosaminas/efeitos adversos , Hexosaminas/farmacocinética , Ácido N-Acetilneuramínico/sangue , Administração Oral , Adulto , Idoso , Alelos , Animais , Miopatias Distais/genética , Miopatias Distais/fisiopatologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Hexosaminas/administração & dosagem , Homozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Músculos/efeitos dos fármacos , Músculos/metabolismo , Mutação , Ácido N-Acetilneuramínico/biossíntese , Fosfotransferases (Aceptor do Grupo Álcool)/genética
2.
Artigo em Inglês | MEDLINE | ID: mdl-26218770

RESUMO

N-acetylneuraminic acid (Neu5Ac or NANA) is the most predominant sialic acid in mammals. As a terminal component in many glycoproteins and glycolipids, sialic acid is believed to be an important biomarker related to various diseases. Its precursor, N-acetylmannosamine (ManNAc), is being investigated as a potential treatment for GNE myopathy. In this work, we developed two highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for the quantitation of ManNAc and free Neu5Ac in human plasma. A fit-for-purpose approach was adopted during method validation and sample analysis. To measure the endogenous compounds and overcome the interference from plasma samples, a surrogate matrix that contained 5% bovine serum albumin (BSA) was used for the preparation of calibration standards and certain levels of quality control (QC) samples. QC samples at higher concentrations were prepared in the authentic matrix (human plasma) to best mimic incurred samples. For both methods, an Ostro 96-well phospholipid removal plate was used for sample extraction, which efficiently removed the phospholipids from the plasma samples prior to LC injection, eliminated matrix effect, and improved sensitivity. Chromatographic separation was achieved using hydrophilic interaction chromatography (HILIC) and gradient elution in order to retain the two polar compounds. The lower limit of quantitation (LLOQ) for ManNAc and Neu5Ac was 10.0 and 25.0ng/mL, respectively. The overall accuracy of the two assays was within 100%±8.3% based on three levels of QC samples. Inter- and intra-run precision (coefficient of variation (%CV)) across three analytical runs was less than 6.7% for ManNAc and less than 10.8% for Neu5Ac. These methods have been validated to support clinical studies.


Assuntos
Cromatografia Líquida/métodos , Hexosaminas/sangue , Ácido N-Acetilneuramínico/sangue , Espectrometria de Massas em Tandem/métodos , Estabilidade de Medicamentos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA