Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 32(9): 15269-15279, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38859182

RESUMO

Telescopes play an essential important role in the fields of astronomical observation, emergency rescue, etc. The traditional telescopes achieve zoom function through the mechanical movement of the solid lenses, usually requiring refocusing after magnification adjustment. Therefore, the traditional telescopes lack adaptability, port-ability and real-time capability. In this paper, a continuous optical zoom telescopic system based on liquid lenses is proposed. The main components of the system consist of an objective lens, an eyepiece, and a zoom group composed of six pieces of liquid lenses. By adjusting the external voltages on the liquid lenses, the zoom telescopic system can achieve continuous optical zoom from ∼1.0× to ∼4.0× operating with an angular resolution from 28.648" to 19.098", and the magnification switching time is ∼50ms. The optical structure of the zoom telescopic system with excellent performance is given, and its feasibility is demonstrated by simulations and experiments. The proposed system with fast response, portability and high adaptability is expected to be applied to astronomical observation, emergency rescue and so on.

2.
Opt Express ; 31(10): 16067-16080, 2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37157693

RESUMO

Microscopy is being pursued to obtain richer and more accurate information, and there are many challenges in imaging depth and display dimension. In this paper, we propose a three-dimensional (3D) microscope acquisition method based on a zoom objective. It enables 3D imaging of thick microscopic specimens with continuous adjustable optical magnification. The zoom objective based on liquid lenses can quickly adjust the focal length, to expand the imaging depth and change the magnification by adjusting the voltage. Based on the zoom objective, an arc shooting mount is designed to accurately rotate the objective to obtain the parallax information of the specimen and generate parallax synthesis images for 3D display. A 3D display screen is used to verify the acquisition results. The experimental results show that the obtained parallax synthesis images can accurately and efficiently restore the 3D characteristics of the specimen. The proposed method has promising applications in industrial detection, microbial observation, medical surgery, and so on.

3.
Opt Express ; 31(26): 43416-43426, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38178435

RESUMO

Inspired by the arrangement of iris and crystalline lens in human eyes, we propose a three-phase electrowetting liquid lens with a deformable liquid iris (TELL-DLI). The proposed electrowetting liquid lens has three-phase fluid: air, conductive liquid, and dyed insulating liquid. The insulating liquid is distributed on the inner wall of the chamber in a ring shape. By applying voltage, the contact angle is changed, so that the dyed insulating liquid contracts towards the center, which is similar to the contraction of iris and the function of crystalline lens muscle in human eyes. The variation range of focal length is from -451.9 mm to -107.9 mm. The variation range of the aperture is from 4.89 mm to 0.6 mm. Under the step voltage of 200 V, the TELL-DLI can be switched between the maximum aperture state and the zero aperture state, and the switching time is ∼150/200 ms. Because of the discrete electrodes, TELL-DLI can regionally control the shape and position of the iris, and switch between circle, ellipse, sector, and strip. The TELL-DLI has a wide application prospect in imaging systems, such as microscopic imaging system, and has the potential to be applied in the field of complex beam navigation.

4.
Opt Express ; 30(25): 44580-44593, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36522880

RESUMO

Depth of field (DOF) and resolution are mutually restricted in integral imaging (II) display. To overcome the trade-offs, we propose an II display system that simultaneously enhances the DOF and resolution. The system consists of a transmissive mirror device (TMD), a semi-transparent mirror (STM), and two II display units. Each II display unit consists of a 4K display screen and a micro-lens array (MLA). Benefiting from the parallel placement of the TMD and the STM, two central depth planes are reconstructed, which effectively enhances the DOF. Meanwhile, the resolution in the overlapping DOF region is increased to two times due to the interpolation of the light field information from two II display units. The impact of the distance between the two II display units and the TMD on the 3D image quality is analyzed. In geometric optics, a distance between the II two display units and the TMD is optimized to eliminate ghost images. In wave optics, a distance is optimized to eliminate 3D pixel gaps by exploiting the diffraction effect of the TMD. Both the geometric and wave optics are considered simultaneously to obtain a high-quality 3D image without ghost images and 3D pixel gaps. A DOF and resolution-enhanced II display system is developed, and the experimental results verify its feasibility.

5.
Opt Express ; 29(23): 37418-37428, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808813

RESUMO

In this paper, we propose an optofluidic lenticular lens array (OLLA) for a two-dimensional/three-dimensional (2D/3D) switchable display. The OLLA includes a bottom substrate layer with lenticular lens structure, a microfluidic layer with microchannels, and a top substrate layer with inlets as well as outlets. A micro gap is formed between the lenticular lens of the bottom substrate layer and the top substrate layer. When air is in the micro gap, the OLLA behaves as a lenticular lens array, which can realize 3D display. When fluid is filled in the micro gap, because the refractive index of the fluid is the same with the lenticular lens structure, the OLLA equivalents to a transparent flat panel, which can realize a 2D display. Experiments verify that a switchable 2D/3D display prototype based on this OLLA and a smartphone achieves both high-resolution 2D display and high-quality 3D display.

6.
Opt Express ; 29(17): 27104-27117, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34615132

RESUMO

In this paper, a high stability liquid lens with optical path modulation function is designed and fabricated. The liquid lens has an outer chamber and an inner chamber, and the inner chamber has a structure with three annular anchoring layers. This structure can limit the sliding of the three-phase contact line under electrowetting effect and anchor the position of contact angle with a limited distance. The feasibility of this structure is verified by simulation and practice. The zoom imaging, contact angle, focal length and response time of the liquid lens are analyzed. The structure with three annular anchoring layers provides six anchored precision optical path modulation gears, and the optical path difference can be changed by mechanical hydraulic control, up to 1.17 mm. Widespread applications of the proposed liquid lens are foreseeable such as microscopic imaging and a telescope system, etc.

7.
Sci Rep ; 10(1): 14644, 2020 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-32887926

RESUMO

The conventional microscope has discrete magnification and slow response time in zoom process, which is difficult to capture the dynamic activity of the live specimen. We demonstrate an adaptive microscope employing a tunable objective and a tunable eyepiece with large zooming range. The tunable objective consists of three glass lenses and four electrowetting liquid lenses. The tunable eyepiece consists of an achromatic eyepiece and an electrowetting liquid lens. The focal point between the objective and the eyepiece is designed to be tunable, which are controlled by voltages. Thus, the tuning range is relatively large. We fabricate the adaptive microscope and observe the specimen. In the experiment, the magnification of the microscope changes continuously from ~ 59.1 × to ~ 159.2 × , and the largest numerical aperture is ~ 0.212. The tunable eyepiece can release the back focal length of the tunable objective, which increases the zoom range of the microscope. No mechanical movement is required and the aberrations can be corrected over a wide wavelength range. Thus, the proposed adaptive microscope has a potential application in biological research and clinical medical examination.

8.
Sci Rep ; 10(1): 12389, 2020 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-32709880

RESUMO

In this paper, we propose a real time, ultrahigh accuracy and full-field-of-view (RUF) algorithm for full field of view (FOV) imaging system. The proposed algorithm combines rough matching and precise matching method to stitch multiple images with the whole FOV in short time and high imaging quality. In order to verify real-time imaging effect of RUF algorithm, we also fabricate a multi-camera imaging system which includes 19 independent cameras. And the experiment result practically illustrates that full-FOV system can achieve good performances under a near-limiting FOV of 360° × 240° with low distortion, meanwhile, optical resolution reaches up to 95 megapixels. 100% registration-accuracy RUF algorithm for imaging in one second can be widely applied to any optical imaging engineering field with large FOV, such as remote sensing imaging, microscopy imaging, monitoring system engineering fields and so on.

9.
Sci Rep ; 9(1): 13062, 2019 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-31506551

RESUMO

The conventional electrowetting lens usually has one tunable liquid-liquid (L-L) interface. The shape of L-L interface is deformed to get variable focal length due to electrowetting effect. However, contact angle saturation of the L-L interface is an unavoidable problem which prevents focal length from further changing. Here, we demonstrate an optofluidic lens based on electrowetting liquid piston. The proposed lens has two connected chambers, the piston chamber and the lens chamber to form a closed-loop fluidic system. The electrowetting liquid piston can generate clockwise and counter-clockwise liquid flows, which can make the L-L interface convex and concave. To prove the concept, we fabricate an optofluidic device whose shortest negative and positive focal lengths are ~-17.9 mm and ~18 mm with 5 mm aperture, respectively. The proposed optofluidic lens has large tunable focal length range. Widespread application of such an adaptive lens is foreseeable.

10.
Opt Express ; 25(19): 22280-22291, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041541

RESUMO

We report an electrically controlled optofluidic zoom system which can achieve a large continuous zoom change and high-resolution image. The zoom system consists of an optofluidic zoom objective and a switchable light path which are controlled by two liquid optical shutters. The proposed zoom system can achieve a large tunable focal length range from 36mm to 92mm. And in this tuning range, the zoom system can correct aberrations dynamically, thus the image resolution is high. Due to large zoom range, the proposed imaging system incorporates both camera configuration and telescope configuration into one system. In addition, the whole system is electrically controlled by three electrowetting liquid lenses and two liquid optical shutters, therefore, the proposed system is very compact and free of mechanical moving parts. The proposed zoom system has potential to take place of conventional zoom systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA