Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Clin Med ; 13(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38592271

RESUMO

Coronary artery disease (CAD) remains a significant global health concern, necessitating timely and precise diagnosis, especially for acute coronary syndromes (ACSs). Traditional diagnostic methods like electrocardiograms (ECGs) are critical, yet the advent of echocardiography has revolutionized cardiac care by providing comprehensive insights into heart function. This article examines the integration of echocardiography in the cardiac catheterization laboratory, emphasizing its role in augmenting traditional diagnostics, enhancing patient outcomes, and preparing for targeted interventions. Specifically, we argue for the routine use of focused echocardiographic evaluations in patients presenting with ST-Elevation Myocardial Infarction (STEMI) to the cath lab, illustrating how this practice can significantly refine diagnostic accuracy, identify concurrent life-threatening conditions, and inform the management of STEMI and its complications.

2.
Minerva Cardiol Angiol ; 72(2): 172-181, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38088090

RESUMO

BACKGROUND: Paravalvular leakage (PVL) is a common finding after transcatheter aortic valve replacement (TAVR) and affects late clinical outcome. It is more frequent with self-expandable (SE) transcatheter-heart-valve (THV). Few is known about SE-THV expansion after implantation. The purpose is to assess SE-THV frame expansion and its possible influence on PVL. METHODS: We designed a prospective pilot study to assess the time-course of SE-THV frame dimensions and PVL after TAVR. Consecutive patients undergoing TAVR with SE-THV were enrolled. Prosthesis fluoroscopy and echocardiography were prospectively performed immediately after TAVR (T0) and before discharge (T1) to grade PVL. Prosthesis diameters were assessed in 2 fluoroscopic orthogonal views. PVL reduction ≥1+ from T0 to T1 at echocardiography was the primary study endpoint. RESULTS: Twenty-five patients were enrolled. Mean interval between T0 and T1 evaluations was 5 days. Grade 1 or 2 was present in 76% of patients at T0 and in 68% at T1 (P=0.034). A total of 7 patients (28%) improved PVL ≥1 grade from T0 to T1. Differences between T0 and T1 fluoroscopic diameters were not statistically significant. When comparing the diameter changes according to PVL evolution, patients with PVL improvement (as compared with those without) had significantly larger minimum diameter increase at both annulus/inflow (P=0.016) and outflow/distal edge (P=0.027). CONCLUSIONS: PVL may improve in the early days after SE-THV and those patients with PVL improvement may have THV frame expansion. Further studies are needed to confirm such preliminary observations and to establish the clinical relevance of this phenomenon.


Assuntos
Insuficiência da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estudos Prospectivos , Projetos Piloto , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Desenho de Prótese
3.
Int J Cardiol ; 370: 356-365, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36343795

RESUMO

AIMS: Wall shear stress (WSS) is involved in coronary artery plaque pathological mechanisms and modulation of gene expression. This study aims to provide a comprehensive haemodynamic and biological description of unstable (intact-fibrous-cap, IFC, and ruptured-fibrous-cap, RFC) and stable (chronic coronary syndrome, CCS) plaques and investigate any correlation between WSS and molecular pathways. METHODS AND RESULTS: We enrolled 24 CCS and 25 Non-ST Elevation Myocardial Infarction-ACS patients with IFC (n = 11) and RFC (n = 14) culprit lesions according to optical coherence tomography analysis. A real-time PCR primer array was performed on peripheral blood mononuclear cells for 17 different molecules whose expression is linked to WSS. Computational fluid dynamics simulations were performed in high-fidelity 3D-coronary artery anatomical models for three patients per group. A total of nine genes were significantly overexpressed in the unstable patients as compared to CCS patients, with no differences between IFC and RFC groups (GPX1, MMP1, MMP9, NOS3, PLA2G7, PI16, SOD1, TIMP1, and TFRC) while four displayed different levels between IFC and RFC groups (TNFα, ADAMTS13, EDN1, and LGALS8). A significantly higher WSS was observed in the RFC group (p < 0.001) compared to the two other groups. A significant correlation was observed between TNFα (p < 0.001), EDN1 (p = 0.036), and MMP9 (p = 0.005) and WSS values in the RFC group. CONCLUSIONS: Our data demonstrate that IFC and RFC plaques are subject to different WSS conditions and gene expressions, suggesting that WSS profiling may play an essential role in the plaque instability characterization with relevant diagnostic and therapeutic implications in the era of precision medicine.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Ruptura Cardíaca , Placa Aterosclerótica , Humanos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/genética , Vasos Coronários/patologia , Leucócitos Mononucleares , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/genética , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/genética , Tomografia de Coerência Óptica/métodos , Ruptura Espontânea/metabolismo , Ruptura Espontânea/patologia , Angiografia Coronária/métodos , Galectinas/metabolismo
4.
JACC Cardiovasc Interv ; 13(1): 49-58, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31918942

RESUMO

OBJECTIVES: The aim of this study was to compare optical coherence tomographic (OCT) guidance and fractional flow reserve (FFR) guidance in patients with angiographically intermediate coronary lesions (AICLs) in a single-center, prospective, 1:1 randomized trial. BACKGROUND: FFR and OCT imaging may help both in the assessment of AICLs and in percutaneous coronary intervention optimization. METHODS: Patients with AICLs were randomized to FFR or OCT imaging. In the FFR arm, PCI was performed if FFR was ≤0.80. In the OCT imaging arm, PCI was performed if area stenosis was ≥75% or 50% to 75% with minimal luminal area <2.5 mm2 or plaque rupture. Angina (evaluated using the Seattle Angina Questionnaire), major adverse cardiac events, and cost were assessed at the end of follow-up. The pre-defined primary endpoint was the composite of major adverse cardiac events or significant angina (defined as Seattle Angina Questionnaire frequency scale score <90) at 13 months. RESULTS: A total of 350 patients (with 446 AICLs) were enrolled (176 randomized to FFR and 174 to OCT imaging). The primary endpoint of major adverse cardiac events or significant angina at 13 months occurred in 14.8% of patients in the FFR arm and in 8.0% in the OCT imaging arm (p = 0.048). This result was driven by a statistically nonsignificant lower occurrence of all primary endpoint components. Up to 13 months, the rate of medically managed patients was significantly higher (p < 0.001) and total cost significantly lower (p < 0.001) with FFR in comparison with OCT imaging. CONCLUSIONS: In patients with AICLs, OCT guidance is associated with lower occurrence of the composite of major adverse cardiac events or significant angina. FFR guidance is associated with a higher rate of medical management and lower costs. FFR or OCT Guidance to Revascularize Intermediate Coronary Stenosis Using Angioplasty [FORZA]; NCT01824030).


Assuntos
Cateterismo Cardíaco , Fármacos Cardiovasculares/uso terapêutico , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Reserva Fracionada de Fluxo Miocárdico/efeitos dos fármacos , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Idoso , Cateterismo Cardíaco/economia , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/economia , Tomada de Decisão Clínica , Estenose Coronária/economia , Estenose Coronária/fisiopatologia , Redução de Custos , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/economia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Cidade de Roma , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia de Coerência Óptica/economia , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 96(2): 459-470, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31925991

RESUMO

OBJECTIVES: To describe and report the results of an original technique for trans-femoral (TF) transcatheter-aortic-valve-replacement (TAVR). BACKGROUND: TF approach represents the commonest TAVR technique. The best technique for TF-TAVR is not recognized. METHODS: We developed a less-invasive totally-endovascular (LITE) technique for TF-TAVR. The key aspects are: precise TAVR access puncture using angiographic-guidewire-ultrasound guidance radial approach as the "secondary access" (to guide valve positioning, to check femoral-access hemostasis and to manage eventual access-site complications) non-invasive pacing (by retrograde left ventricle stimulation or by definitive pace-maker external programmer) The LITE technique has been systematically adopted at our Institution. Procedure details, complications and clinical events occurring during hospitalization were prospectively recorded. Major vascular complications and life-threatening or major bleedings were the primary study end-points. RESULTS: A total of 153 consecutive patients referred for TF-TAVR were approached using the LITE technique. Mean predicted surgical operative mortality was 4.9% and mean TAVR predicted mortality was 3.9%. In 132 (86.3%) patients, TAVR was completed without the need for additional femoral artery access or transvenous temporary pace-maker implantation. Major vascular complications occurred in 2 (1.3%), life-threatening or major bleedings occurred in 4 (2.6%) patients. All-cause death occurred in 3 patients (2.0%). CONCLUSIONS: TF-TAVR according to LITE technique is feasible and is associated with very low rates of vascular or bleeding complications.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Estimulação Cardíaca Artificial , Cateterismo Periférico , Artéria Femoral , Artéria Radial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Sistema de Registros , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
J Am Heart Assoc ; 8(15): e012772, 2019 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-31331219

RESUMO

Background Fractional flow reserve (FFR) and optical coherence tomography (OCT) may help both in assessment and in percutaneous coronary intervention optimization of angiographically intermediate coronary lesions. We designed a prospective trial comparing the clinical and economic outcomes associated with FFR or OCT in angiographically intermediate coronary lesions. Methods and Results Three hundred fifty patients with angiographically intermediate coronary lesions (n=446) were randomized to FFR or OCT guidance. In the FFR arm, percutaneous coronary intervention was performed if FFR was ≤0.80 aiming for a postprocedure FFR >0.90. In the OCT arm, percutaneous coronary intervention was performed if percentage of area stenosis was ≥75% or 50% to 75% with minimal lumen area <2.5 mm2 or plaque ulceration. Costs, angina frequency, and major adverse cardiac events were assessed at 1 month and at 13 months. We present early data at 1 month consistent with a prespecified analysis of secondary end points. Patients randomized to FFR, as compared with OCT, were significantly more commonly managed with medical therapy alone (67.7% versus 41.1%; P<0.001), required less contrast media (245±137 versus 280±129 mL; P=0.004), and exhibited a lower occurrence of contrast-induced acute kidney injury (1.7% versus 8.6%; P=0.034). At 1 month, in comparison to FFR, OCT was associated with increased total costs (2831±1288 versus 4292±3844 euros/patient; P<0.001) whereas occurrence of major adverse cardiac events or significant angina was similar. Conclusions In patients with angiographically intermediate coronary lesions, a functional guidance by FFR, as compared with OCT, increased the rate of patients treated with medical therapy alone. This translated into a significant reduction in administered contrast, contrast-induced acute kidney injury, and total costs at 1 month with FFR. Clinical Trial Registration URL: http://www.clinicaltrialsgov. Unique identifier: NCT01824030.


Assuntos
Estenose Coronária/cirurgia , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Cirurgia Assistida por Computador , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA