Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Intervent Radiol ; 45(6): 858-866, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35378613

RESUMO

PURPOSE: The feasibility of using a compressed interwoven Supera stent as a flow diverting device for popliteal aneurysms was recently demonstrated in patients. It is unclear, however, what the optimal flow diverting strategy is, because of the fusiform shape of popliteal aneurysms and their exposure to triphasic flow. To assess this flow diverting strategy for popliteal aneurysms, flow profiles and thrombus formation likelihood were investigated in popliteal aneurysm models. MATERIALS AND METHODS: Six popliteal aneurysm models were created and integrated into a pulsatile flow set-up. These models covered a bent and a straight anatomy in three configurations: control, single-lined and dual-lined Supera stents. Two-dimensional flow velocities were visualized by laser particle image velocimetry. In addition, the efficacy of the stent configurations for promoting aneurysm thrombosis was assessed by simulations of residence time and platelet activation. RESULTS: On average for the two anatomies, the Supera stent led to a twofold reduction of velocities in the aneurysm for single-lined stents, and a fourfold reduction for dual-lined stents. Forward flow was optimally diverted, whereas backward flow was generally deflected into the aneurysm. The dual-lined configuration led to residence times of 15-20 s, compared to 5-15 s for the single stent configurations. Platelet activation potential was not increased by the flow diverting stents. CONCLUSION: A compressed Supera stent was successfully able to divert flow in a popliteal aneurysm phantom. A dual-lined configuration demonstrated superior hemodynamic characteristics compared to its single-lined counterpart.


Assuntos
Aneurisma , Artéria Poplítea , Ligas , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Humanos , Artéria Poplítea/diagnóstico por imagem , Desenho de Prótese , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
Med Eng Phys ; 37(7): 683-91, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26004506

RESUMO

The maximum diameter, total volume of the abdominal aorta, and its growth rate are usually regarded as key factors for making a decision on the therapeutic operation time for an abdominal aortic aneurysm (AAA) patient. There is, however, a debate on what is the best standard method to measure the diameter. Currently, two dominant methods for measuring the maximum diameter are used. One is measured on the planes perpendicular to the aneurism's central line (orthogonal diameter) and the other one is measured on the axial planes (axial diameter). In this paper, another method called 'inscribed-spherical diameter' is proposed to measure the diameter. The main idea is to find the diameter of the largest sphere that fits within the aorta. An algorithm is employed to establish a centerline for the AAA geometries obtained from a set of longitudinal scans obtained from South Korea. This centerline, besides being the base of the inscribed spherical method, is used for the determination of orthogonal and axial diameter. The growth rate parameters are calculated in different diameters and the total volume and the correlations between them are studied. Furthermore, an exponential growth pattern is sought for the maximum diameters over time to examine a nonlinear growth pattern of AAA expansion both globally and locally. The results present the similarities and discrepancies of these three methods. We report the shortcomings and the advantages of each method and its performance in the quantification of expansion rates. While the orthogonal diameter measurement has an ability of capturing a realistic diameter, it fluctuated. On the other hand, the inscribed sphere diameter method tends to underestimate the diameter measurement but the growth rate can be bounded in a narrow region for aiding prediction capability. Moreover, expansion rate parameters derived from this measurement exhibit good correlation with each other and with growth rate of volume. In conclusion, although the orthogonal method remains the main method of measuring the diameter of an abdominal aorta, employing the idea of maximally inscribed spheres provides both a tool for generation of the centerline, and an additional parameter for quantification of aneurysmal growth rates.


Assuntos
Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/patologia , Aortografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Povo Asiático , Progressão da Doença , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Dinâmica não Linear , Tamanho do Órgão , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , República da Coreia , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA