1.
Injury ; 45(2): 379-82, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24119651

RESUMO

We present the case report of a 40-year-old woman who was HIV-positive in Highly Active Anti-Retroviral Therapy (HAART) and affected by femural pertrochanteric fracture, which was treated by endomedullary nailing. Two years after the surgical operation, the woman developed an aseptic symptomatic osteolysis around the implant. Hardware removal was resolutive. Aseptic and septic hardware mobilization, hardware removal, and implant decision in HIV patients with pertrochanteric fractures is discussed. The authors suggest close follow-up and prompt hardware removal, as soon as X-rays demonstrate healing signs, in HIV patients with fracture fixation, if general condition allows.


Assuntos
Remoção de Dispositivo/métodos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas , Fixação Intramedular de Fraturas/efeitos adversos , Soropositividade para HIV/imunologia , Osteólise/imunologia , Adulto , Terapia Antirretroviral de Alta Atividade , Feminino , Fraturas do Fêmur/complicações , Fraturas do Fêmur/imunologia , Consolidação da Fratura , Soropositividade para HIV/complicações , Humanos , Imunidade Celular , Osteólise/etiologia , Amplitude de Movimento Articular , Reoperação , Resultado do Tratamento