Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Coron Artery Dis ; 33(6): 433-439, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35811572

RESUMO

BACKGROUND: Previous studies showed conflicting results regarding the contribution of coronary collateral circulation (CCC) to myocardial perfusion and function in the setting of myocardial infarction (MI). In the primary angioplasty era, the role of CCC in these studies may have been influenced by the effect of early reperfusion. The true impact of CCC could be clarified by studying its effect on nonreperfused patients. The aim of our study was to evaluate the effect of CCC on myocardial viability of late presentation MI. METHODS AND RESULTS: Between 2008 and 2019, we included 167 patients with a late presentation MI who had a complete angiographic occlusion in a major coronary artery in which myocardial viability of the culprit territory was assessed. Patients were divided according to the presence of angiographic early recruited CCC (ERCC) (Rentrop 2-3) or poor CCC (PCC) (Rentrop 0-1). A lower left ventricular ejection function (LVEF) at discharge (54.2 ± 9 vs. 47.9 ± 12; <0.01) and a more severe left ventricular wall motion abnormalities in the culprit territory were observed in PCC patients. The presence of ERCC was the main independent predictor of myocardial viability in late presentation MI (hazard ratio, 4.24; 95% confidence interval, 1.68-10.6; P < 0.001). At follow-up, wall motion score increased significantly (2.05 ± 0.16; P = 0.02) in patients with ERCC but not in PCC patients (0.07 ± 0.16; P = 0.4), and LVEF improvement was significantly higher in ERCC than in PCC patients (9.7 ± 2.6 vs. 3.8 ± 4.2; P = 0.02). CONCLUSION: The presence of ERCC was the main independent predictor of myocardial viability in late presentation MI.


Assuntos
Circulação Coronária , Infarto do Miocárdio , Circulação Colateral , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Função Ventricular Esquerda
2.
World J Cardiol ; 14(1): 1-12, 2022 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-35126868

RESUMO

Use of ionizing radiation during cardiac catheterization interventions adversely impacts both the patients and medical staff. In recent years, radiation dose in cardiac catheterization interventions has become a topic of increasing interest in interventional cardiology and there is a strong interest in reducing radiation exposure during the procedures. This review presents the current status of radiation protection in the cardiac catheterization laboratory and summarizes a practical approach for radiation dose management for minimizing radiation exposure. This review also presents recent innovations that have clinical potential for reducing radiation during cardiac interventions.

3.
Catheter Cardiovasc Interv ; 98(4): E523-E530, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33979479

RESUMO

BACKGROUND: The use of ionizing radiation during cardiac catheterization interventions adversely impacts the medical staff. Traditional radiation protection equipment is only partially effective. The Cathpax® radiation protection cabin (RPC) has proven to significantly reduce radiation exposure in electrophysiological and neuroradiology interventions. Our objective was to analyze whether the Cathpax® RPC reduces radiation dose in coronary and cardiac structural interventions in unselected real-world procedures. METHODS AND RESULTS: In this nonrandomized all-comers prospective study, 119 consecutive cardiac interventional procedures were alternatively divided into two groups: the RPC group (n = 59) and the non-RPC group (n = 60). No significant changes in the characteristics of patients and procedures, average contrast volume, air kerma (AK), dose area-product (DAP) and fluoroscopy time between both groups were apparent. In the RPC group, the first-operator relative radiation exposure was reduced by 78% at the chest and by 70% at the wrist. This effect was consistent during different types of procedures including complex percutaneous interventions and structural procedures. CONCLUSIONS: Our study demonstrates, for the first time, that the Cathpax® cabin significantly and efficiently reduces relative operator radiation exposure during different types of interventional procedures, confirming its feasibility in a real-world setting.


Assuntos
Cardiologia , Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Fluoroscopia , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Resultado do Tratamento
4.
Am J Cardiol ; 141: 31-37, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33220317

RESUMO

Coronary flow reserve (CFR) is a well-validated flow-based physiological parameter that has shown value in clinical risk stratification. CFR can be invasively assessed, classically by Doppler and, more recently, by thermodilution with saline boluses (CFRthermo-bolus). Alternatively, continuous thermodilution is a novel operator-independent, highly-reproducible technique to invasively quantify maximum absolute coronary flow (AF). This study aimed to assess the feasibility of this method to quantify resting AF and to determine CFR (CFRThermo-infusion) as compared with CFRthermo-bolus. Sixty-two consecutive patients with suspicion of coronary disease and absence of significant epicardial lesions were prospectively investigated. AF at maximal hyperemia (20 mL/min) and at lower infusion rates (6-8-10-12 mL/min) were systematically measured using a dedicated catheter and a temperature/pressure guidewire. The absence of baseline Pd/Pa decrease at 6 (0.15 ± 0.2%), 8 (0.17 ± 0.18%) and 10 mL/min (0.2 ± 0.12%) demonstrated absence of hyperemia at ≤10 mL/min (all p = NS). However, at 12 mL/min hyperemia was confirmed by a significant decrease in Pd/Pa (1.3 ± 1.5%, p <0.01) and increase in AF from 10 mL/min to 12 mL/min (31.4 ± 28.1 mL, p <0.05). All curve tracings at 10 mL/min (129/129, 100%) were adequate versus only (7/15, 53%) and (15/18, 17%) at 6 mL/min, and 8 mL/min, respectively, and this infusion-rate was considered to determine resting-AF. CFRThermo-infusion was determined as the ratio of hyperemic-AF (20 mL/min) by resting-AF (10 mL/min). Mean CFRThermo-infusion was 2.56 ± 0.9 and CFRthermo-bolus 2.49 ± 1. Both parameters showed a good correlation (r = 0.76; p <0.001) and intraclass agreement (ICC = 0.76; p <0.001).The continuous thermodilution method enables to quantify resting-AF providing a novel clinical tool to determine CRF. CFRThermo-infusion shows a good correlation with CFRthermo-bolus..


Assuntos
Circulação Coronária , Vasos Coronários/fisiopatologia , Hiperemia/fisiopatologia , Microcirculação , Microvasos , Termodiluição/métodos , Idoso , Cateterismo Cardíaco , Angiografia Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Reprodutibilidade dos Testes , Solução Salina
5.
Coron Artery Dis ; 29(7): 550-556, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29965836

RESUMO

BACKGROUND: Debate still remains on whether the presence of early recruited collateral circulation (ERCC) in the setting of an acute coronary occlusion (ACO) has a prognosis benefit. Some previous reports have shown lower mortality and morbidity rates in well-collateralized patients compared with those with poorly recruited collateral circulation (PCC), but others have not. In the primary angioplasty era, the role of collateral circulation in these studies may have been influenced by the effect of early reperfusion. The actual impact of ERCC in ACO can be clarified by studying its effect on nonreperfused patients. OBJECTIVE: This study aimed to compare the 1-year clinical outcome in nonreperfused late presentation ACO in a major coronary artery with ERCC versus PCC. PATIENTS AND METHODS: Between 2008 and 2015, we included 164 patients with a nonreperfused late presentation ACO. The patients were divided according to the presence of angiographic ERCC (Rentrop 2-3) or PCC (Rentrop 0-1). ERCC was present in 54% of patients. Patients with ERCC less often presented with cardiogenic shock (P=0.02) and the right coronary artery was the most frequent culprit vessel (P=0.02). The presence of PCC was associated independently with higher 1-year cardiovascular mortality [hazard ratio (HR): 6.92; 95% confidence interval (95%CI): 1.37-34.7; P=0.019], 1-year total mortality (HR: 5.79; 95%CI: 1.95-17.1; P=0.001), and 1-year major adverse cardiac event (HR: 8.05; 95%CI: 1.73-37.4; P<0.01). CONCLUSION: The presence of angiographically PCC in the setting of late presentation nonreperfused ACO is relatively infrequent (46%) and is associated with worse 1-year major clinical outcomes.


Assuntos
Circulação Colateral , Circulação Coronária , Oclusão Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Idoso , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Espanha , Fatores de Tempo
6.
Rev Esp Cardiol ; 62(4): 438-41, 2009 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-19401129

RESUMO

Periprosthetic mitral valve regurgitation due to paravalvular leakage is one of the complications of valve replacement surgery. We report a series of eight patients with severe symptomatic periprosthetic mitral regurgitation in whom surgery could not be performed because of the high risk. All patients were assigned to percutaneous closure of periprosthetic mitral valve leaks using an Amplatzer duct occluder. The procedure was successful in five patients. A significant reduction in periprosthetic regurgitation and a clinical improvement were observed in four of the patients. The procedure was unsuccessful in three patients: in two due to interference with the prosthesis discs; in the other, because it was not possible to pass through the leak. One of these three patients died a few hours after the procedure due to severe stroke. Percutaneous closure of paravalvular leakage in patients at a high surgical risk is technically feasible and has an acceptable clinical success rate.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA