Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Phys Med ; 123: 103402, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38875932

RESUMO

PURPOSE: One of the advantages of integrating automated processes in treatment planning is the reduction of manual planning variability. This study aims to assess whether a deep-learning-based auto-planning solution can also reduce the contouring variation-related impact on the planned dose for early-breast cancer treatment. METHODS: Auto- and manual plans were optimized for 20 patients using both auto- and manual OARs, including both lungs, right breast, heart, and left-anterior-descending (LAD) artery. Differences in terms of recalculated dose (ΔDrcM,ΔDrcA) and reoptimized dose (ΔDroM,ΔDroA) for manual (M) and auto (A)-plans, were evaluated on manual structures. The correlation between several geometric similarities and dose differences was also explored (Spearman's test). RESULTS: Auto-contours were found slightly smaller in size than manual contours for right breast and heart and more than twice larger for LAD. Recalculated dose differences were found negligible for both planning approaches except for heart (ΔDrcM=-0.4 Gy, ΔDrcA=-0.3 Gy) and right breast (ΔDrcM=-1.2 Gy, ΔDrcA=-1.3 Gy) maximum dose. Re-optimized dose differences were considered equivalent to recalculated ones for both lungs and LAD, while they were significantly smaller for heart (ΔDroM=-0.2 Gy, ΔDroA=-0.2 Gy) and right breast (ΔDroM =-0.3 Gy, ΔDroA=-0.9 Gy) maximum dose. Twenty-one correlations were found for ΔDrcM,A (M=8,A=13) that reduced to four for ΔDroM,A (M=3,A=1). CONCLUSIONS: The sensitivity of auto-planning to contouring variation was found not relevant when compared to manual planning, regardless of the method used to calculate the dose differences. Nonetheless, the method employed to define the dose differences strongly affected the correlation analysis resulting highly reduced when dose was reoptimized, regardless of the planning approach.

2.
Cancers (Basel) ; 16(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38893216

RESUMO

Objectives: We investigated spatial patterns between primary and recurrent tumor sites and assessed long-term toxicity after dose escalation stereotactic body radiation therapy (SBRT) to the dominant intra-prostatic nodule (DIN). Materials and methods: In 33 patients with intermediate-high-risk prostate cancer (PCa), doses up to 50 Gy were administered to the DIN. Recurrence sites were determined and compared to the original tumor development sites through multiparametric MRI and 68Ga-labeled prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (68Ga-PSMA-PET/CT) images. Overlap rates, categorized as 75% or higher for full overlap, and 25-74% for partial overlap, were assessed. Long-term toxicity is reported. Results: All patients completed treatment, with only one receiving concomitant androgen deprivation therapy (ADT). Recurrences were diagnosed after a median of 33 months (range: 17-76 months), affecting 13 out of 33 patients (39.4%). Intra-prostatic recurrences occurred in 7 patients (21%), with ≥75% overlap in two, a partial overlap in another two, and no overlap in the remaining three patients. Notably, five patients with intra-prostatic recurrences had synchronous bone and/or lymph node metastases, while six patients had isolated bone or lymph node metastasis without intra-prostatic recurrences. Extended follow-up revealed late grade ≥ 2 GU and GI toxicity in 18% (n = 6) and 6% (n = 2) of the patients. Conclusions: Among patients with intermediate-high-risk PCa undergoing focal dose-escalated SBRT without ADT, DIN recurrences were infrequent. When present, these recurrences were typically located at the original site or adjacent to the initial tumor. Conversely, relapses beyond the DIN and in extra-prostatic (metastatic) sites were prevalent, underscoring the significance of systemic ADT in managing this patient population. Advances in knowledge: Focal dose-escalated prostate SBRT prevented recurrences in the dominant nodule; however, extra-prostatic recurrence sites were frequent.

3.
Med Phys ; 51(4): 3010-3019, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38055371

RESUMO

BACKGROUND: Studies comparing different radiotherapy treatment techniques-such as volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT)-typically compare one treatment plan per technique. Often, some dose metrics favor one plan and others favor the other, so the final plan decision involves subjective preferences. Pareto front comparisons provide a more objective framework for comparing different treatment techniques. A Pareto front is the set of all treatment plans where improvement in one criterion is possible only by worsening another criterion. However, different Pareto fronts can be obtained depending on the chosen machine settings. PURPOSE: To compare VMAT and HT using Pareto fronts and blind expert evaluation, to explain the observed differences, and to illustrate limitations of using Pareto fronts. METHODS: We generated Pareto fronts for twenty-four prostate cancer patients treated at our clinic for VMAT and HT techniques using an in-house script that controlled a commercial treatment planning system. We varied the PTV under-coverage (100% - V95%) and the rectum mean dose, and fixed the mean doses to the bladder and femoral heads. In order to ensure a fair comparison, those fixed mean doses were the same for the two treatment techniques and the sets of objective functions were chosen so that the conformity indexes of the two treatment techniques were also the same. We used the same machine settings as are used in our clinic. Then, we compared the VMAT and HT Pareto fronts using a specific metric (clinical distance measure) and validated the comparison using a blinded expert evaluation of treatment plans on these fronts for all patients in the cohort. Furthermore, we investigated the observed differences between VMAT and HT and pointed out limitations of using Pareto fronts. RESULTS: Both clinical distance and blind treatment plan comparison showed that VMAT Pareto fronts were better than HT fronts. VMAT fronts for 10 and 6 MV beam energy were almost identical. HT fronts improved with different machine settings, but were still inferior to VMAT fronts. CONCLUSIONS: That VMAT Pareto fronts are better than HT fronts may be explained by the fact that the linear accelerator can rapidly vary the dose rate. This is an advantage in simple geometries that might vanish in more complex geometries. Furthermore, one should be cautious when speaking about Pareto optimal plans as the best possible plans, as their calculation depends on many parameters.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias da Próstata/radioterapia , Reto , Órgãos em Risco
4.
Phys Imaging Radiat Oncol ; 28: 100492, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37780177

RESUMO

Background and purpose: Automation in radiotherapy treatment planning aims to improve both the quality and the efficiency of the process. The aim of this study was to report on a clinical implementation of a Deep Learning (DL) auto-planning model for left-sided breast cancer. Materials and methods: The DL model was developed for left-sided breast simultaneous integrated boost treatments under deep-inspiration breath-hold. Eighty manual dose distributions were revised and used for training. Ten patients were used for model validation. The model was then used to design 17 clinical auto-plans. Manual and auto-plans were scored on a list of clinical goals for both targets and organs-at-risk (OARs). For validation, predicted and mimicked dose (PD and MD, respectively) percent error (PE) was calculated with respect to manual dose. Clinical and validation cohorts were compared in terms of MD only. Results: Median values of both PD and MD validation plans fulfilled the evaluation criteria. PE was < 1% for targets for both PD and MD. PD was well aligned to manual dose while MD left lung mean dose was significantly less (median:5.1 Gy vs 6.1 Gy). The left-anterior-descending artery maximum dose was found out of requirements (median values:+5.9 Gy and + 2.9 Gy, for PD and MD respectively) in three validation cases, while it was reduced for clinical cases (median:-1.9 Gy). No other clinically significant differences were observed between clinical and validation cohorts. Conclusion: Small OAR differences observed during the model validation were not found clinically relevant. The clinical implementation outcomes confirmed the robustness of the model.

5.
Phys Med ; 114: 103139, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37757500

RESUMO

PURPOSE: In inverse radiotherapy treatment planning, the Pareto front is the set of optimal solutions to the multi-criteria problem of adequately irradiating the planning target volume (PTV) while reducing dose to organs at risk (OAR). The Pareto front depends on the chosen optimisation parameters whose influence (clinically relevant versus not clinically relevant) is investigated in this paper. METHODS: Thirty-one prostate cancer patients treated at our clinic were randomly selected. We developed an in-house Python script that controlled the commercial treatment planning system RayStation to calculate directly deliverable Pareto fronts. We calculated reference Pareto fronts for a given set of objective functions, varying the PTV coverage and the mean dose of the primary OAR (rectum) and fixing the mean doses of the secondary OARs (bladder and femoral heads). We calculated the fronts for different sets of objective functions and different mean doses to secondary OARs. We compared all fronts using a specific metric (clinical distance measure). RESULTS: The in-house script was validated for directly deliverable Pareto front calculations in two and three dimensions. The Pareto fronts depended on the choice of objective functions and fixed mean doses to secondary OARs, whereas the parameters most influencing the front and leading to clinically relevant differences were the dose gradient around the PTV, the weight of the PTV objective function, and the bladder mean dose. CONCLUSIONS: Our study suggests that for multi-criteria optimisation of prostate treatments using external therapy, dose gradient around the PTV and bladder mean dose are the most influencial parameters.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Próstata , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco
6.
Br J Radiol ; 96(1145): 20220803, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36745031

RESUMO

OBJECTIVES: We conducted a phase I/II prospective trial to determine whether stereotactic dose escalation to the dominant intra-prostatic nodule (DIN) up to 50 Gy incorporating a rectal balloon spacer is safe, does not affect patient quality of life, and preserves local control in patients with intermediate-high risk PCa. METHODS: Eligible patients included males with stage ≤T3b localized disease, a prostate-specific antigen (PSA) level ≤50 , International Prostate Symptom Score (IPSS) ≤14, and a gland volume ≤70 cm3. Patients underwent perirectal spacer placement, followed by a planning MRI and were subsequently treated with SBRT doses of 36.25 Gy in five fractions to the whole prostate while simultaneously escalating doses to the magnetic resonance image visible DIN up to 50 Gy. Primary endpoint: safety. Secondary endpoints: biochemical control, quality of life (QofL), and dosimetry outcome. RESULTS: Nine patients were treated in the Phase I part of the study. Dose limiting toxicities (DLTs) were not observed. Further characterization of tolerability and efficacy was conducted in the subsequent 24 patients irradiated at the recommended Phase II dose (50 Gy, RP2D). At a median follow-up of 61 months, biochemical control is 69%. Grade 1 and 2 acute GU and GI toxicity was 57.5 and 15%, and 24.2 and 6.1%, respectively. Grade 1 and 2 late GU and GI toxicity was 66.6 and 12.1%, and 15.1 and 3%, respectively. No Grade 3 or higher toxicity was reported. QofL data confirmed physician's reported side effects. Dosimetry analysis showed adherence to the doses prescribed in the protocol. CONCLUSIONS: SBRT of the whole prostate with 36.25 Gy in 5 fractions and dose escalation to 50 Gy to the DIN, when combined with a peri-rectal balloon spacer, was tolerable and established the RP2D. QofL analysis showed minimal negative impact in GU, GI, and sexual domains. ADVANCES IN KNOWLEDGE: Extreme hypofractionated prostate radiation therapy with focal dose escalation to the DIN is well tolerated with efficacy comparable to normal fractionated radiation therapy.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Antígeno Prostático Específico , Neoplasias da Próstata/patologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Prospectivos , Qualidade de Vida
7.
Clin Transl Radiat Oncol ; 39: 100557, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36561729

RESUMO

A 40-year-old patient with cT4cN1M0 squamous cell lung cancer of the upper right lobe received preoperative induction chemotherapy. Systemic induction treatment failed to reverse tumour growth with the addition of conventional radiotherapy (RT). A salvage lattice RT boost of 12 Gy was administered immediately to increase the dose to the tumour. Conventional RT was resumed at the planned dose of 60 Gy. The tumour shrank rapidly, and the patient was surged. The postoperative pathology remained ypT0ypN0 status.

8.
Phys Med ; 90: 30-39, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34530213

RESUMO

PURPOSE: To assess the interplay effect amplitude between different planned MU distributions and respiratory patterns in the CyberKnife system when treating moving targets with static tracking technique. METHODS: Small- and Large-Respiratory Motions (SRM and LRM) differing in amplitude and frequency were simulated in a semi-anthropomorphic dynamic thorax phantom. The interplay effect was evaluated for both respiration motions in terms of GTV coverage and conformity for three plans designed with an increasing range of MU per beam (small, medium and large). Each plan was delivered three times changing the initial beam-on phase to assess the inter-fraction variation. Dose distributions were measured using radiochromic films placed in the GTV axial and sagittal planes. RESULTS: Generally, SRM plans gave higher GTV coverage and were less dependent on beam-on phases than LRM plans. For SRM (LRM) plans, the GTV coverage ranged from 95.2% to 99.7% (85.9% to 99.8%). Maximum GTV coverage was found for large MU plans in SRM and for small MU plans in LRM. Minimum GTV coverage was found for medium MU plans for both SRM and LRM. For SRM plans, dose conformity decreased with increasing MU range while the variation was reduced for LRM plans. Large MU plans reduced the inter-fraction variation for SRM and LRM. CONCLUSIONS: We confirmed the interplay effect between target motion and beam irradiation time for CyberKnife static tracking. Plans with large MU per beam improved the GTV coverage for small motion amplitude and the inter-fraction dose variation for large motion amplitude.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Pulmonares/cirurgia , Movimento (Física) , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Respiração
9.
Front Cardiovasc Med ; 7: 108, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32671101

RESUMO

Ventricular tachycardia (VT) caused by myocardial scaring bears a significant risk of mortality and morbidity. Antiarrhythmic drug therapy (AAD) and catheter ablation remain the cornerstone of VT management, but both treatments have limited efficacy and potential adverse effects. Stereotactic body radiotherapy (SBRT) is routinely used in oncology to treat non-invasively solid tumors with high precision and efficacy. Recently, this technology has been evaluated for the treatment of VT. This review presents the basic underlying principles, proof of concept, and main results of trials and case series that used SBRT for the treatment of VT refractory to AAD and catheter ablation.

10.
Acta Neurochir (Wien) ; 162(9): 2203-2210, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32556528

RESUMO

INTRODUCTION: The Gamma Knife® planning software (TMR 10, Elekta Instruments, AB, Sweden) affords two ways of defining the skull volume, the "historical" one using manual measurements (still perform in some centers) and the new one using image-based skull contours. Our objective was to assess the potential variation of the dose delivery calculation using consecutively in the same patients the two above-mentioned techniques. MATERIALS AND METHODS: We included in this self-case-control study, 50 patients, treated with GKRS between July 2016 and January 2017 in Lausanne University Hospital, Switzerland, distributed among four groups: convexity targets (n = 18), deep-seated targets (n = 13), vestibular schwannomas (n = 11), and trigeminal neuralgias (n = 8). Each planning was performed consecutively with the 2 skull definition techniques. For each treatment, we recorded the beam-on time (min), target volume coverage (%), prescription isodose volume (cm3), and maximal dose (Gy) to the nearest organ at risk if relevant, according to each of the 2 skull definition techniques. The image-based contours were performed using CT scan segmentation, based upon a standardized windowing for all patients. RESULTS: The median difference in beam-on time between manual measures and image-based contouring was + 0.45 min (IQR; 0.2-0.6) and was statistically significant (p < 0.0001), corresponding to an increase of 1.28% beam-on time per treatment, when using image-based contouring. The target location was not associated with beam-on time variation (p = 0.15). Regarding target volume coverage (p = 0.13), prescription isodose volume (p = 0.2), and maximal dose to organs at risk (p = 0.85), no statistical difference was reported between the two skull contour definition techniques. CONCLUSION: The beam-on time significantly increased using image-based contouring, resulting in an increase of the total dose delivery per treatment with the new TMR 10 algorithm. Other dosimetric parameters did not differ significantly. This raises the question of other potential impacts. One is potential dose modulation that should be performed as an adjustment to new techniques developments. The second is how this changes the biologically equivalent dose per case, as related to an increased beam on time, delivered dose, etc., and how this potentially changes the radiobiological effects of GKRS in an individual patient.


Assuntos
Neuroma Acústico/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Crânio/diagnóstico por imagem , Algoritmos , Humanos , Pessoa de Meia-Idade , Radiometria , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
11.
Radiother Oncol ; 152: 163-168, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32448409

RESUMO

BACKGROUND AND PURPOSE: Early-stage Hodgkin lymphoma (HL) is a highly curable disease but the treatment can induce late complications many years later. Irradiation of the healthy heart is inevitable during radiation treatment of mediastinal sites. We developed a novel method to induce a prolonged apnea-like state that can help decrease the dose to organs at risk during radiation therapy. We present the results of the first 8 HL patients treated routinely with percussion assisted radiation therapy (PART) in our clinic. MATERIAL AND METHODS: We used a newly developed high-frequency non-invasive ventilation system to suppress respiratory motion for prolonged periods and push the heart away from the treated volume. RESULTS: All 8 patients were able to rapidly learn the technique and had an advantage to be treated by PART. We lowered the mean heart dose by an average of 3 Gy with similar target coverage compared to a classical free breathing treatment plan. They were all treated for 15 radiotherapy sessions by PART without any notable side effects. CONCLUSIONS: Percussion assisted radiation therapy can be used routinely to reduce the dose to the heart in Hodgkin lymphoma.


Assuntos
Doença de Hodgkin , Lesões por Radiação , Radioterapia de Intensidade Modulada , Coração , Doença de Hodgkin/radioterapia , Humanos , Órgãos em Risco , Percussão , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
12.
Clin Transl Radiat Oncol ; 21: 62-65, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31993511

RESUMO

Although cardiac metastases (CM) are more common than primary cardiac malignant tumors, they remain a rare localization of metastatic cancer. Until recently, CM were surgically treated as a palliative approach because of a lack of ablative solutions even for oligometastatic patients. Technological advances in radiation therapy (RT) in thoracic oncology have led to high precision delivery that enlarged the indications for stereotactic body radiotherapy (SBRT). To date, there are limited reports of cardiac SBRT for CM. Herein, we report a cardiac SBRT performed in curative intent for a lung cancer patient metastatic to the heart.

13.
Phys Med ; 64: 230-237, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31515024

RESUMO

PURPOSE: A novel optimization algorithm (VOLO™) for robotic radiosurgery in the Precision™ treatment planning system was evaluated for different SRS/SBRT treatments and compared with the previous Sequential Optimization (SO) algorithm. MATERIALS AND METHODS: Fifty cases of brain, spine, prostate and lung tumors previously optimized with SO, were re-planned with VOLO™ algorithm keeping the same prescription, collimator type and size, optimization shells, and blocking structures. The dosimetric comparison involved target coverage, conformity (CI), gradient (GI) and homogeneity indexes, specific indicators of dose to OARs and number of nodes, beams, MU and delivery time. For brain only, plans were IRIS- and MLC-based (10 each). The remaining 30 plans were all IRIS-based. RESULTS: VOLO™ optimization was significantly superior for target coverage for prostate and spine, CI for brain, and for brain and urethra dose sparing. SO gave significantly better results for GI for prostate. VOLO™ showed a significantly steeper dose fall-off for brain MLC-based, while for prostate and spine SO was superior. For IRIS-based plans, VOLO™ significantly reduced the nodes (36%), beams (14%), and MU (31%). This led to an average reduction of delivery time of 20% (from 8% for brain to 30% for prostate). For MLC-based plans, VOLO™ significantly increased the nodes and beams (42%) keeping the same number of MU. The averaged delivery time increased by 18%. CONCLUSIONS: With respect to SO, VOLO™ optimization algorithm provided better results in terms of delivery time for IRIS-based and of quality of dose distribution for MLC-based plans, respectively.


Assuntos
Algoritmos , Radiocirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Masculino , Metástase Neoplásica , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Radiometria , Planejamento da Radioterapia Assistida por Computador
14.
J Cancer Res Clin Oncol ; 145(8): 2167, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31201485

RESUMO

The article "Neoadjuvant chemoradiotherapy delivered with helical tomotherapy under daily image guidance for rectal cancer patients: efficacy and safety in a large, multi-institutional series".

15.
Rev Med Suisse ; 15(652): 1082-1086, 2019 May 22.
Artigo em Francês | MEDLINE | ID: mdl-31116523

RESUMO

Stereotactic body radiotherapy (SBRT) is routinely used in oncology to treat non-invasively solid tumors with high precision and efficacy. Recently, this technology has been evaluated in the treatment of ventricular tachycardia (VT). This article presents the basic underlying principles, proofs of concept and main results of clinical studies that used SBRT for the treatment of VT.


La radiothérapie stéréotaxique (SBRT) est une technologie couramment utilisée en oncologie pour traiter de façon non invasive les tumeurs solides avec précision et efficacité. Récemment, cette technologie a été évaluée dans le traitement des tachycardies ventriculaires (TV). Cet article présente les principes de base sous-jacents, le concept ainsi que les résultats des premières études cliniques ayant traité avec succès des patients souffrant de TV avec la SBRT.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/radioterapia
16.
J Cancer Res Clin Oncol ; 145(4): 1075-1084, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30830296

RESUMO

PURPOSE: Helical tomotherapy (HT) has been recently introduced in the neoadjuvant treatment of locally advanced rectal cancer. Aim of this study is to report the toxicity and local control rates of a large series of locally advanced rectal cancer patients treated with neoadjuvant chemotherapy and HT under daily image guidance followed by surgery. METHODS: Data from 117 locally advanced rectal cancer patients treated at two Swiss Radiotherapy departments were collected and analyzed. Radiotherapy consisted of 45 Gy (1.8 Gy/fraction, 5 fractions/week delivered in 5 weeks) to the regional pelvic lymph nodes. Seventy patients also received a simultaneous integrated boost (SIB) up to 50 Gy to the tumor and involved nodes (2 Gy/fraction, 5 fractions/week delivered in 5 weeks). Chemotherapy consisted of capecitabine 825 mg/m2, twice daily, during the irradiation days. After a median interval of 59 days [95% confidence interval (CI) 53-65 days), all patients underwent surgery. RESULTS: Median follow-up was 45 months (range 4-90 months). The overall rate of acute grade 2-4 toxicity was 18.8% (n = 22). Four patients (3.4%) presented a grade 3 dermatitis (n = 1) or diarrhea (n = 3), and 1 (0.8%) demonstrated grade 4 rectal toxicity. No patients presented with grade ≥ 3 hematologic toxicity. Six patients (5.1%) had late grade 3 gastrointestinal toxicity. The 4-year local control rate was 88.4% (95% CI 87.5-88.5%). CONCLUSIONS: Neoadjuvant chemoradiotherapy delivered with HT under daily image guidance is well tolerated and shows a high 4-year local control rates.


Assuntos
Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antimetabólitos Antineoplásicos/uso terapêutico , Capecitabina/uso terapêutico , Quimiorradioterapia Adjuvante , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Estadiamento de Neoplasias , Radioterapia Guiada por Imagem , Neoplasias Retais/tratamento farmacológico , Neoplasias Retais/radioterapia , Tomografia Computadorizada por Raios X , Imagem Corporal Total
17.
Acta Neurochir (Wien) ; 161(4): 721-727, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30790090

RESUMO

INTRODUCTION: Stereotactic radiosurgery (SRS) is increasingly used as a minimally invasive alternative in many neurosurgical conditions, including benign and malignant tumors, vascular malformations, and functional procedures. As for any surgical procedure, strict safety guidelines and checklists are necessary to avoid errors and the inherent unnecessary complications. With regard to the former, other groups have already reported human and/or technical errors. We describe our safety checklist for Gamma Knife radiosurgical procedures. METHODS: We describe our checklist protocol after an experience gained over 1500 radiosurgical procedures, using Gamma Knife radiosurgery, performed over a period of 8 years, while employing the same list of items. Minor implementation has been performed over time to address some safety issues that could be improved. RESULTS: Two types of checklist are displayed. One is related to the indications when a specific tissue volume is irradiated, including tumors or vascular disorders. The second corresponds to functional disorders, such as when the dose is prescribed to one specific point. Using these checklists, no human error had been reported during the past 8 years of practice in our institution. CONCLUSION: The use of a safety checklist for SRS procedures promotes a zero-tolerance attitude for errors. This can lower the complications and is of major help in promoting multidisciplinary cooperation. We highly recommend the use of such tool, especially in the context of the increased use of SRS in the neurosurgical field.


Assuntos
Lista de Checagem , Radiocirurgia/métodos , Técnicas Estereotáxicas , Humanos , Resultado do Tratamento
18.
PLoS One ; 13(10): e0204013, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30304045

RESUMO

PURPOSE: To study the potential of (99m)Tc-Mebrofenin hepatobiliary scintigraphy (HBS) in identifying the short-term variations of liver function after stereotactic body radiotherapy (SBRT) for liver cancers. MATERIAL AND METHODS: We treated with SBRT 3 patients (pts) affected by a cholangiocarcinoma and 3 patient presenting liver metastases (3x15 Gy, 4 pts; 5x8 Gy, 1 pt; 6x5 Gy, 1 pt). All patients received HBS before and 3 months after SBRT, which were co-registered with the simulation CT-scan. Structures corresponding to isodoses from 10-90 Gy were created, with intervals of 10 Gy. Finally, the variations of the mean activity (MBq) in each isodose structure have been calculated. Then, a linear regression analysis was performed. RESULTS: We showed a linear reduction of the activity, significantly related to the delivered dose (p<0.01), and a reduction of the perfusion of 0.78% for each delivered Gy. The linear equation has predictive value of the loss of the function of 96% (R2 = 0.9605). CONCLUSIONS: HBS could improve treatment plans for liver SBRT, by allowing the identification of the liver function variations after SBRT and, potentially, the prediction of remnant liver function after SBRT. These preliminary results should be confirmed on long-term prospective data and larger population.


Assuntos
Neoplasias dos Ductos Biliares/radioterapia , Colangiocarcinoma/radioterapia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Cintilografia/métodos , Radiocirurgia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Compostos de Anilina , Fracionamento da Dose de Radiação , Feminino , Glicina , Humanos , Iminoácidos/administração & dosagem , Modelos Lineares , Testes de Função Hepática , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio/administração & dosagem , Projetos Piloto , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
J Neurol Surg B Skull Base ; 79(Suppl 4): S362-S370, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30210991

RESUMO

Objective Planned subtotal resection followed by Gamma Knife surgery (GKS) in patients with large vestibular schwannoma (VS) has emerged during the past decade, with the aim of a better functional outcome for facial and cochlear function. Methods We prospectively collected patient data, surgical, and dosimetric parameters of a consecutive series of patients treated by this method at Lausanne University Hospital during the past 8 years. Results A consecutive series of 47 patients were treated between July 2010 and January 2018. The mean follow-up after surgery was 37.5 months (median: 36, range: 0.5-96). Mean presurgical tumor volume was 11.8 mL (1.47-34.9). Postoperative status showed normal facial nerve function (House-Brackmann I) in all patients. In a subgroup of 28 patients, with serviceable hearing before surgery and in which cochlear nerve preservation was attempted at surgery, 26 (92.8%) retained serviceable hearing. Nineteen had good or excellent hearing (Gardner-Robertson class 1) before surgery, and 16 (84.2%) retained it after surgery. Mean duration between surgery and GKS was 6 months (median: 5, range: 3-13.9). Mean residual volume as compared with the preoperative one at GKS was 31%. Mean marginal dose was 12 Gy (11-12). Mean follow-up after GKS was 34.4 months (6-84). Conclusion Our data show excellent results in large VS management with a combined approach of microsurgical subtotal resection and GKS on the residual tumor, with regard to the functional outcome and tumor control. Longer term follow-up is necessary to fully evaluate this approach, especially regarding tumor control.

20.
Radiother Oncol ; 128(2): 189-191, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29753550

RESUMO

Stereotactic body radiotherapy (SBRT) is an emerging non-invasive treatment in the management of ventricular tachycardia (VT). We report here an intensive care patient suffering from an electrical storm due to incessant VT, unresponsive to catheter ablation and anti-arrhythmic drugs, showing an immediate and durable response to electrophysiology-guided cardiac SBRT.


Assuntos
Braquiterapia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Taquicardia Ventricular/radioterapia , Idoso , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA