Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Artigo em Chinês | MEDLINE | ID: mdl-38433696

RESUMO

Subglottic masses is very rare. The clinical data of five cases of subglottic mass in our hospital from 2017 to 2022 were summarized, and their clinical manifestations, auxiliary examination findings, treatment plan and pathological features were analyzed. Among the 5 patients, 1 case was subglottic pleomorphic adenoma, 1 case was subglottic granuloma, 1 case was subglottic breast cancer metastasis, 1 case was subglottic primary adenoid cystic carcinoma, and 1 case was immunoglobulin G4-related disease. No recurrence was observed in the patients so far. Subglottic mass is easy to be missed. Therefore, when the lesion is suspected in this area, the examination of ear, nose and throat should be carried out systematically to detect the lesion early and improve the prognosis.


Assuntos
Adenoma Pleomorfo , Carcinoma Adenoide Cístico , Doença Relacionada a Imunoglobulina G4 , Neoplasias Laríngeas , Humanos , Carcinoma Adenoide Cístico/diagnóstico , Carcinoma Adenoide Cístico/terapia , Neoplasias Laríngeas/diagnóstico , Neoplasias Laríngeas/terapia , Pescoço
2.
Zhongguo Gu Shang ; 37(1): 33-44, 2024 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-38286449

RESUMO

OBJECTIVE: To observe the cage subsidence after oblique lateral interbody fusion (OLIF) for lumbar spondylosis, summarize the characteristics of the cage subsidence, analyze causes, and propose preventive measures. METHODS: The data of 144 patients of lumbar spine lesions admitted to our hospital from October 2015 to December 2018 were retrospectively analyzed. There were 43 males and 101 females, and the age ranged from 20 to 81 years old, with an average of (60.90±10.06) years old. Disease types:17 patients of lumbar intervertebral disc degenerative disease, 12 patients of giant lumbar disc herniation, 5 patients of discogenic low back pain, 33 patients of lumbar spinal stenosis, 26 patients of lumbar degenerative spondylolisthesis, 28 patients of lumbar spondylolisthesis with spondylolisthesis, 11 patients of adjacent vertebral disease after lumbar internal fixation, 7 patients of primary spondylitis in the inflammatory outcome stage, and 5 patients of lumbar degenerative scoliosis. Preoperative dual-energy X-ray bone mineral density examination showed 57 patients of osteopenia or osteoporosis, and 87 patients of normal bone density. The number of fusion segments:124 patients of single-segment, 11 patients of two-segment, 8 patients of three-segment, four-segment 1 patient. There were 40 patients treated by stand-alone OLIF, and 104 patients by OLIF combined with posterior pedicle screw. Observed the occurrence of fusion cage settlement after operation, conducted monofactor analysis on possible risk factors, and observed the influence of fusion cage settlement on clinical results. RESULTS: All operations were successfully completed, the median operation time was 99 min, and the median intraoperative blood loss was 106 ml. Intraoperative endplate injury occurred in 30 patients and vertebral fracture occurred in 5 patients. The mean follow-up was (14.57±7.14) months from 6 to 30 months. During the follow-up, except for the patients of primary lumbar interstitial inflammation and some patients of lumbar spondylolisthesis with spondylolisthesis, the others all had different degrees of cage subsidence. Cage subsidence classification:119 patients were normal subsidence, and 25 patients were abnormal subsidence (23 patients were gradeⅠ, and 2 patients were gradeⅡ). There was no loosening or rupture of the pedicle screw system. The height of the intervertebral space recovered from the preoperative average (9.48±1.84) mm to the postoperative average (12.65±2.03) mm, and the average (10.51±1.81) mm at the last follow-up. There were statistical differences between postoperative and preoperative, and between the last follow-up and postoperative. The interbody fusion rate was 94.4%. The low back pain VAS decreased from the preoperative average (6.55±2.2 9) to the last follow-up (1.40±0.82), and there was statistically significant different. The leg pain VAS decreased from the preoperative average (4.72±1.49) to the final follow-up (0.60±0.03), and the difference was statistically significant (t=9.13, P<0.000 1). The ODI index recovered from the preoperative average (38.50±6.98)% to the latest follow-up (11.30±3.27)%, and there was statistically significant different. The complication rate was 31.3%(45/144), and the reoperation rate was 9.72%(14/144). Among them, 8 patients were reoperated due to fusion cage subsidence or displacement, accounting for 57.14%(8/14) of reoperation. The fusion cage subsidence in this group had obvious characteristics. The monofactor analysis showed that the number of abnormal subsidence patients in the osteopenia or osteoporosis group, Stand-alone OLIF group, 2 or more segments fusion group, and endplate injury group was higher than that in the normal bone mass group, OLIF combined with pedicle screw fixation group, single segment fusion group, and no endplate injury group, and the comparison had statistical differences. CONCLUSION: Cage subsidence is a common phenomenon after OLIF surgery. Preoperative osteopenia or osteoporosis, Stand-alone OLIF, 2 or more segments of fusion and intraoperative endplate injury may be important factors for postoperative fusion cage subsidence. Although there is no significant correlation between the degree of cage subsidence and clinical symptoms, there is a risk of cage migration, and prevention needs to be strengthened to reduce serious complications caused by fusion of cage subsidence, including reoperation.


Assuntos
Doenças Ósseas Metabólicas , Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Dor Lombar , Osteoporose , Escoliose , Fusão Vertebral , Espondilolistese , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Espondilolistese/cirurgia , Estudos Retrospectivos , Dor Lombar/etiologia , Vértebras Lombares/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos , Osteoporose/etiologia , Resultado do Tratamento
3.
BMC Urol ; 23(1): 163, 2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37833702

RESUMO

BACKGROUND AND AIMS: There are no clear conclusions as to whether heart failure (HF) and coronary heart disease (CAD) increase the risk of erectile dysfunction (ED).In our study, we used Mendelian randomization (MR) analysis to discover a causal relationship between HF, CAD and ED. METHODS: Single nucleotide polymorphisms (SNPs) associated with HF, CAD and ED were obtained from the MRC IEU Open Genome-Wide Association Study (GWAS) database.After a series of screenings, the remaining SNPs were selected as instrumental variables (IVs) for HF and CAD for MR analysis to assess the relationship between genetically predicted HF or CAD and the pathogenesis of ED.Among them, we used the random-effects inverse variance weighted (IVW) method as the primary analysis method.Finally, Cochran's q-test, funnel plots, MR-Egger regression, Leave-one-out method and MR-PRESSO were used for sensitivity analysis. RESULTS: In the IVW method, there was no significant causal relationship between genetically predicted HF and CAD and the incidence of ED.(HF: OR = 1.17, 95% CI 0.99-1.39; p = 0.074;CAD: OR = 1.08, 95% CI 0.99-1.17, p = 0.068)。The results of sensitivity analyses supported our conclusion that no horizontal pleiotropism was found. CONCLUSION: This study did not find a causal relationship between HF or CAD and ED in European populations, which requires further in-depth research.


Assuntos
Doença da Artéria Coronariana , Disfunção Erétil , Insuficiência Cardíaca , Masculino , Humanos , Doença da Artéria Coronariana/genética , Disfunção Erétil/epidemiologia , Disfunção Erétil/genética , Estudo de Associação Genômica Ampla , Análise da Randomização Mendeliana , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/genética
4.
Mol Pharm ; 20(9): 4654-4663, 2023 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-37616278

RESUMO

Liposomal delivery systems are recognized as efficient and safe platforms for chemotherapeutic agents, with doxorubicin-loaded liposomes being the most representative nanopharmaceuticals. Characterizing the structure of liposomal nanomedicines in high spatial and temporal resolution is critical to analyze and evaluate their stability and efficacy. Small-angle X-ray scattering (SAXS) is a powerful tool increasingly used to investigate liposomal delivery systems. In this study, we chose a Doxil-like PEGylated liposomal doxorubicin (PLD) as an example and characterized the liposomal drug structure using synchrotron SAXS. Classical analytical models, including the spherical-shell or flat-slab geometries with Gaussian or uniform electron density profiles, were used to model the internal structure of the liposomal membrane. A cylinder model was applied to fit the scattering from the drug crystal loaded in the liposomes. The high-resolution structures of the original drug, Caelyx, and a similar research drug prepared in our laboratory were characterized using these analytical models. The structural parameters of PLDs, including the thickness of the liposomal membrane and morphology of the drug crystal, were further compared. The results demonstrated that both spherical-shell and flat-slab geometries with Gaussian electron density distribution were suitable to elucidate the structural features of the liposomal membrane under a certain range of scattering vectors, while models with uniform electron density distribution exhibited poor fitting performance. This study highlights the technical features of SAXS, which provides structural information at the nanoscale for liposomal drugs. The demonstrated methods are reliable and easy-to-use for the structural analysis of liposomal drugs, which are helpful for a broader application of SAXS in the production and regulation of nanopharmaceuticals.


Assuntos
Doxorrubicina , Lipossomos , Espalhamento a Baixo Ângulo , Difração de Raios X , Raios X
5.
Clin Spine Surg ; 36(8): E390-E396, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37448192

RESUMO

STUDY DESIGN: This was a retrospective cohort study. OBJECTIVE: To compare the early clinical efficacy and radiologic outcomes between unilateral biportal endoscopic lumbar interbody fusion (ULIF) and minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF). SUMMARY OF BACKGROUND DATA: Along with the continuous development of endoscopic technology, the early safety and effectiveness of ULIF technology are still unknown. MATERIALS AND METHODS: This retrospective study included 61 patients who underwent fusion surgery through ULIF or MIS-TLIF in 2021. Twenty-nine patients underwent ULIF (group A), and 32 underwent MIS-TLIF (group B). Fusion rate, bone graft volume, hidden blood loss (HBL), C-reactive protein level, operative time, Oswestry Disability Index , Visual Analog Scale score, and MacNab criteria were assessed in both groups. RESULTS: The Visual Analog Scale score for back pain in the early postoperative period was significantly lower in group A than in group B ( P <0.05). All other clinical scores showed improvement, with no significant difference between the 2 groups ( P >0.05). There was no statistically significant difference in postoperative C-reactive protein levels and fusion rates between the 2 groups ( P >0.05). However, HBL was higher and operative time was longer in group A than in group B ( P <0.05). Most importantly, there were no statistically significant differences between groups A and B in fusion rate, length of stay and bone graft volume ( P >0.05). No serious surgical complications occurred in our study. CONCLUSIONS: ULIF is a new option for lumbar fusion. Despite the drawbacks of longer operation time and higher HBL, ULIF may be a viable alternative to MIS-TLIF as technology advances.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos , Fusão Vertebral , Humanos , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Proteína C-Reativa , Resultado do Tratamento
6.
Zhongguo Gu Shang ; 36(5): 465-72, 2023 May 25.
Artigo em Chinês | MEDLINE | ID: mdl-37211941

RESUMO

OBJECTIVE: To evaluate the early clinical efficacy of robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation in the treatment of stageⅡ-Ⅲ Kümmell disease. METHODS: The clinical data of 20 patients with stageⅡ-Ⅲ Kümmell's disease who underwent robot-assisted percutaneous bone cement-augmented pedicle screw fixation between June 2017 and January 2021 were retrospectively analyzed. There were 4 males and 16 females, aged from 60 to 81 years old with an average age of (69.1±8.3) years. There were 9 cases of stageⅡand 11 cases of stage Ⅲ, all of which were single vertebral lesions, including 3 cases of T11, 5 cases of T12, 8 cases of L1, 3 cases of L2, and 1 case of L3. These patients did not exhibit symptoms of spinal cord injury. The operation time, intraoperative blood loss, and complications were recorded. The position of pedicle screws and the filling and leakage of bone cement in gaps were observed using postoperative CT 2D reconstruction. The data of the visual analogue scale (VAS), Oswestry disability index (ODI), kyphosis Cobb angle, wedge angle of the diseased vertebra, and anterior and posterior vertebral height on lateral radiographs were statistically analyzed preoperatively, 1 week postoperatively, and at the final follow-up. RESULTS: Twenty patients were followed up for 10 to 26 months, with an average follow-up of (16.0±5.1) months. All operations were successfully completed. The surgical duration ranged from 98 to 160 minutes, with an average of (122±24) minutes. The intraoperative blood loss ranged from 25 to 95 ml, with an average of (45±20) ml. There were no intraoperative vascular nerve injuries. A total of 120 screws were inserted in this group, including 111 screws at grade A and 9 screws at grade B according to the Gertzbein and Robbins scales. Postoperative CT indicated that the bone cement was well-filled in the diseased vertebra, and cement leakage occurred in 4 cases. Preoperative VAS and ODI were (6.05±0.18) points and (71.10±5.37)%, respectively, (2.05±0.14) points and (18.57±2.77)% at 1 week after operation, and (1.35±0.11) points and (15.71±2.12) % at final follow-up. There were significant differences between postoperative 1 week and preoperative, and between final follow-up and postoperative 1 week(P<0.01). Anterior and posterior vertebral height, kyphosis Cobb angle, and wedge angle of the diseased vertebra were(45.07±1.06)%, (82.02±2.11)%, (19.49±0.77) °, and (17.56±0.94) ° preoperatively, respectively, (77.00±0.99)%, (83.04±2.02)%, (7.34±0.56) °, and (6.15±0.52) ° at 1 week postoperatively, and (75.13±0.86)%, (82.39±0.45)%, (8.38±0.63) °, and (7.09±0.59) ° at the final follow-up. CONCLUSION: Robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation demonstrates satisfactory short-term efficacy in treating stageⅡ-Ⅲ Kümmell's disease as an effective minimally invasive alternative. However, longer operation times and strict patient selection criteria are necessary, and long-term follow-up is required to determine its lasting effectiveness.


Assuntos
Cifose , Parafusos Pediculares , Robótica , Fraturas da Coluna Vertebral , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Vértebras Lombares/lesões , Resultado do Tratamento , Vértebras Torácicas/lesões , Fixação Interna de Fraturas
7.
J Colloid Interface Sci ; 640: 456-471, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-36870221

RESUMO

The occurrence of micropollutants in aquatic media raises great concern because of their biological toxicity and persistence. Herein, visible-light-driven photocatalyst titanium dioxide/graphitic carbon nitride/triiron tetraoxide (TiO2-x/g-C3N4/Fe3O4, TCNF) with oxygen vacancies (Ov) was prepared via a facile hydrothermal-calcination method. The complementary visible-light co-absorption among semiconductors enhances light-harvesting efficiency. The built-in electric field formed during Fermi level alignment drives photoinduced electron transfer to improve charge separation across the interfaces. The increased light-harvesting and favorable energy band bending significantly enhance the photocatalytic performance. Therefore, TCNF-5-500/persulfate system could effectively photodegrade bis-phenol A within 20 min under visible-light irradiation. Moreover, the superior durability, non-selective oxidation, adaptability, and eco-friendliness of the system were confirmed by different reaction conditions and biotoxicity assessment. Furthermore, the photodegradation reaction mechanism was presented according to the major reactive oxygen species produced in the system. Thus, this study constructed a dual step-scheme heterojunction by tuning visible-light absorption and energy band structure to increase the charge transfer efficiency and photogenerated carrier lifetime, which has great potential for environmental remediation using visible photocatalysis.

8.
Sci Total Environ ; 870: 161804, 2023 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-36731546

RESUMO

The practical application of bismuth-based photocatalysts in the field of micropollutant photodegradation is limited due to their weak light absorption and rapid charge recombination. Herein, we have developed a novel carbon quantum dots-modified N-BiOCl (CDs-N-BiOCl) photocatalyst to activate persulfate (PS) for the complete elimination of endocrine-disruptor bisphenol A (BPA) under visible light irradiation. The photoelectric properties characterization shows that N atoms could replace Cl atoms or adsorb on Bi atoms to form local N 1s states in the BiOCl lattice, accompanied by the introduction of doping energy levels that shorten the electron migration distance. Meanwhile, the decorated CDs could effectively accept the photoinduced electrons from N-BiOCl conduction band to facilitate the charge separation. Thus, the 7%CDs-N-BiOCl (7CNB) nanocomposite synergistically activated PS realized rapid and effective degradation of BPA within 20 min (degradation efficiency and mineralization reached 100 % and 66.4 % respectively). Moreover, the 7CNB/PS system displayed favorable adaptability, durability, and interference resistance. Furthermore, the biotoxicity experiments demonstrated that the photodegradation intermediates promoted the growth of Escherichia coli which indicates its eco-friendliness for practical application. Finally, the electron transfer mechanism and the formation of reactive oxygen species in the photodegradation process were interpreted. In short, this work will present a promising strategy for bismuth-based photocatalysts to be used for the efficient treatment of real water bodies under visible light irradiation.

9.
Zhongguo Gu Shang ; 36(1): 29-37, 2023 Jan 25.
Artigo em Chinês | MEDLINE | ID: mdl-36653003

RESUMO

OBJECTIVE: To explore the feasibility and clinical effect of Stand-alone oblique lateral interbody fusion (OLIF) in the treatment of lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis. METHODS: A retrospective analysis was performed on 16 cases with lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis admitted to three medical centers from January 2015 to December 2018. There were 6 males and 10 females, the age ranged from 45 to 67 years old with an average of (55.48±8.07) years old, the medical history ranged from 36 to 240 months with an average of (82.40±47.68) months. The lesion sites included L2,3 in 2 cases, L3,4 in 5 cases, and L4,5 in 9 cases. All patients presented with chronic low back pain with lower limb neurological symptoms in 3 cases. All patients were treated by Stand-alone oblique lateral lumbar interbody fusion. Clinical and radiological findings and complications were observed. RESULTS: There was no vascular injury, endplate injury and vertebral fracture during the operation. The mean incision length, operation time, and intraoperative blood loss were(4.06±0.42) cm, (45.12±5.43) min, (33.40±7.29) ml, respectively. The mean visual analogue scale (VAS) of the incision pain was (1.14±0.47) at 72 hours after operation. There was no incision skin necrosis, poor incision healing or infection in patients. Sympathetic chain injury occurred in 1 case, anterolateral pain and numbness of the left thigh in 2 cases, and weakness of the left iliopsoas muscle in 1 case, all of which were transient injuries with a complication rate of 25%(4/16). All 16 patients were followed up from 12 to 36 months with an average of (20.80±5.46) months. The intervertebral space height was significantly recovered after operation, with slight lost during the follow-up. Coronal and sagittal balance of the lumbar spine showed good improvement at the final follow-up. There was no obvious subsidence or displacement of the cage, and the interbody fusion was obtained. At the final follow-up, Japanese Orthopaedic Association(JOA) score and Oswestry disability index(ODI) were significantly improved. CONCLUSION: As long as the selection of case is strict enough and the preoperative examination is sufficients, the use of Stand-alone OLIF in the treatment of lumbar intervertebral disc degeneration with Modic changes and endplate sclerosis has a good results, with obvious clinical advantages and is a better surgical choice.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Masculino , Feminino , Humanos , Pré-Escolar , Degeneração do Disco Intervertebral/cirurgia , Estudos Retrospectivos , Esclerose , Resultado do Tratamento , Vértebras Lombares/cirurgia , Fusão Vertebral/métodos
10.
Biomed Mater Eng ; 34(3): 261-276, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36213986

RESUMO

BACKGROUND: Percutaneous kyphoplasty (PKP) or percutaneous vertebroplasty (PVP) are commonly employed for Kummell's disease in stages II-III; however, these techniques produce some complications. OBJECTIVE: To compare the clinical efficacy and imaging results of percutaneous vertebroplasty + bone cement-augmented short-segment pedicle screw fixation (PSPVP) versus transpedicular intracorporeal bone grafting + pedicle screw fixation (PSIBG) in the treatment of stage II-III Kummell's disease. METHODS: A total of 69 patients admitted between November 2017 and March 2021 were included in this study; 36 of these were treated with PSPVP, and 33 were treated with PSIBG. Patients in the two groups were compared in terms of perioperative, follow-up, and imaging data. RESULTS: No statistically significant differences were found between the two groups in terms of operation duration (P > 0.05). However, the PSPVP group was superior to the PSIBG group in terms of incision length, intraoperative blood loss, and length of stay (P < 0.05). All patients were followed up for more than 12 months. The VAS score, height of anterior vertebral margin, kyphosis Cobb angle, wedge angle of the affected vertebra at seven days after surgery and last follow-up, and the ODI index at the last follow-up of the two groups were significantly improved compared with figures before surgery (P < 0.05). Compared with values before surgery, no statistically significant differences were found in the height of the posterior vertebral margin in the PSPVP group at seven days after surgery and at the last follow-up (P > 0.05). There were also no statistically significant differences in the VAS score, ODI index, kyphosis Cobb angle, and wedge angle of the affected vertebra between the two groups at corresponding time points (P > 0.05). The heights of the anterior and posterior vertebral margins in the PSIBG group were better than those in the PSPVP group after surgery and at the last follow-up (P < 0.05). In the PSPVP group, a pedicle screw fracture occurred in one patient two months after surgery, while an upper adjacent vertebral fracture occurred in one patient eight months after surgery. CONCLUSION: Both PSPVP and PSIBG can achieve good early clinical efficacy in the treatment of stage II-III Kummell's disease, with PSPVP being relatively less invasive while producing a poorer orthopedic effect and more complications than PSIBG.


Assuntos
Cifose , Parafusos Pediculares , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Vertebroplastia/efeitos adversos , Vertebroplastia/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Fraturas da Coluna Vertebral/complicações , Resultado do Tratamento , Cifose/tratamento farmacológico , Cifose/etiologia , Cifose/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Pediculares/efeitos adversos , Estudos Retrospectivos , Cimentos Ósseos/uso terapêutico , Vértebras Lombares
11.
J Hazard Mater ; 437: 129416, 2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-35897174

RESUMO

In recent years, there has been growing interest in the mechanism (radical or nonradical) of persulfate activation processes. In this study, the enhancement of naproxen (NPX) degradation in a Cu0/peroxymonosulfate (PMS) system by complexing reagents was investigated. Surprisingly, neocuproine (NCP) alters the nature of reactive species in the Cu0/PMS system. A high-valent copper species, Cu(III)-NCP, was found to dominate NPX degradation rather than radicals under acid conditions for the first time. Moreover, systematically designed experiments revealed that the Cu(III)-NCP complex was a strong selective oxidant that reacted with organics through a single electron transfer pathway. Meanwhile, the degradation efficiency of NPX was highly dependent on the solution pH and dosage of Cu0 and NCP, but was irrelevant to the concentration of NPX. Additionally, the enhancement of NCP on other copper based PMS activation systems (i.e., Cu2+/HA/PMS and Cu0/HA/PMS systems) was investigated. Considering that the released copper can be removed by a simple precipitation method to meet the effluent standards, the new complex-enhanced Cu0/PMS system provided a new method to enhance the degradation efficiencies of pollutants by a copper-catalyzed Fenton-like system.


Assuntos
Naproxeno , Poluentes Químicos da Água , Cobre , Indicadores e Reagentes , Oxirredução , Peróxidos , Poluentes Químicos da Água/análise
12.
Nat Commun ; 12(1): 6596, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34782615

RESUMO

Covalent triazine frameworks have recently been demonstrated as promising materials for photocatalytic water splitting and are usually used in the form of suspended powder. From a practical point of view, immobilized CTFs materials are more suitable for large-scale water splitting, owing to their convenient separation and recycling potential. However, existing synthetic approaches mainly result in insoluble and unprocessable powders, which make their future device application a formidable challenge. Herein, we report an aliphatic amine-assisted interfacial polymerization method to obtain free-standing, semicrystalline CTFs film with excellent photoelectric performance. The lateral size of the film was up to 250 cm2, and average thickness can be tuned from 30 to 500 nm. The semicrystalline structure was confirmed by high-resolution transmission electron microscope, powder X-ray diffraction, grazing-incidence wide-angle X-ray scattering, and small-angle X-ray scattering analysis. Intrigued by the good light absorption, crystalline structure, and large lateral size of the film, the film immobilized on a glass support exhibited good photocatalytic hydrogen evolution performance (5.4 mmol h-1 m-2) with the presence of co-catalysts i.e., Pt nanoparticles and was easy to recycle.

13.
Front Surg ; 8: 631419, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34422888

RESUMO

Objective: The aim of this study was to evaluate the treatment efficacy of lateral spinal stenosis through the decompression of the nerve root under a multiple planar endoscope. Methods: From January 2017 to March 2019, 52 patients with lumbar spinal stenosis or lumbar spinal stenosis combined with intervertebral disc herniation had been treated via transforaminal approach spinal endoscopy. Our study retrospectively analyzed the treatment outcome. All patients experienced complications with different degrees of facet joint hyperplasia and ligamentum flavum hyperplasia and hypertrophy. Some patients suffered disc herniation. All patients were treated with percutaneous transforaminal approach multiple planar endoscopic decompression. The visual analog scale (VAS) and the Oswestry Disability Index (ODI) were compared before and after the operation, as were the horizontal foramen areas of the medial margins of the upper and lower pedicles of the vertebral arch. The treatment effectiveness was evaluated. Results: VAS and ODI scores were significantly improved at postoperative 3 days, 3 months, 6 months, and the last follow-up (P < 0.05). The area of the intervertebral foramen was 422.5 ± 159.2 mm2 preoperatively and 890.8 ± 367.7 mm2 postoperatively, the difference was statistically significant (P < 0.05). Conclusion: Percutaneous transforaminal approach multiple planar endoscopic decompression could achieve an accurate and effective decompression of the lumbar lateral spinal canal. This procedure has good short-term effects, and is especially suitable for elderly patients.

14.
Zhongguo Gu Shang ; 34(4): 304-4, 2021 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-33896127

RESUMO

OBJECTIVE: To explore the clinical value and safety of unilateral pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion by muscle-splitting approach treatment of recurrent lumbar disc herniation. METHODS: The clinical data of 51 patients with recurrent lumbar disc herniation treated from June 2012 to December 2017 were retrospectively analyzed. There were 32 males and 19 females, aged 34 to 64 years with an average of (51.11± 7.28) years. Lesions invoved L4,5 in 38 cases and L5S1 in 13 cases. All patients had a history of lower back pain and radiation pain of lower limbs(3 bilateral and 48 unilateral)and underwent unilateral pedicle screw combined with contralateral translaminar facet screw fixation and interbody fusion, among which 24 patients were treated through median incision approach (median incision group);other 27 patients were treated through muscle-splitting approach with channel-assisted exposure(muscle-splitting approach group). Operation time, intraoperative blood loss, postoperative drainage and incision length of the two groups were recorded. Visual analogue scale (VAS) was used to score the pain of lumbar incision at 72 h after operation, and JOA low back pain scoring system was used to evaluate the lumbar function preoperatively and at final follow-up. Imaging data were analyzed, including the changes in the height of intervertebral space of diseased segment before operation, 3 to 5 days after operation, and at final follow-up;Cobb angle changes in the coronal and sagittal planes of lumbar spine preoperatively and at final follow-up;multifidus area and multifidus fatty tissue deposition grade before and 12 months after operation; postoperative pedicle screw and laminar process screw position and intervertebral fusion condition. The complications of the two groups were compared. RESULTS: There was no statistical difference in operation time between two groups (P>0.05). Muscle-splitting approach group was better than median incision group in light of incision length, intraoperative blood loss and postoperative drainage volume (P<0.05). VAS score of lumbar incision pain at 72 h after operation was 1.61±0.54 in median incision group and 0.76±0.28 in muscle-splitting approach group(P<0.05). All patients were followed up for 12 to 84 (43.50±15.84) months. At final follow-up, the JOA scores of the two groups were significantly improved compared with those before operation(P<0.05). The rate of pedicle screw malposition was 6.25%(3/48) in medianincision group and 9.26%(5/54) in muscle-splitting approach group, there was no statistically significant difference between two groups (P>0.05). Rate of translaminar facet screw malposition in median incision group (12.50%) was significant less than the muscle-splitting approach group (18.52%)(P< 0.05). The height of the intervertebral space of the two groups was significantly restored 3 to 5 days after operation (P<0.05), and there was also a significant loss of height at final follow-up (P<0.05). At final follow-up, the balance of lumbar coronal plane and sagittal plane in two groups were improved very well (P<0.05). The comparison of the area and grade of the multifidus muscle in two groups 12 months after operation showed that obvious damage to the multifidus muscle were present in the median incision, while the multifidus muscle was less damaged by muscle-splitting approach (P<0.05). The fusion rate was 91.7%(22/24) in the median incision group and 92.6%(25/27) in muscle-splitting approach group(P>0.05). In median incision group, there were 1 case of intraoperative pedicle entry point fracture, 1 case of intraoperative dural tear and 1 case of postoperative nerve root injury;in muscle-splitting approach group, there were 1 case of intraoperative pedicle entry point fracture, 2 cases of intraoperative dural tear, 1 case of postoperative nerve root injury, 2 cases of incision epidermal necrosis and 1 case of poor incision healing. Nerve root injuries in the two groups were caused by incorrect positions of pedicle screws, the screws were immediately adjusted upon discovery. The nerve root symptoms were completely recovered 3 and 6 months after surgery. No incision infection was occurred in two groups. During the follow-up, no pedicle screw and laminar facet screw were loosened, displaced, broken, or intervertebral fusion cage moved forward and backward. The complication rate of 25.93% in muscle-splitting approach group was higher than 12.50% in the median incision group (P<0.05). CONCLUSION: Muscle-splitting approach is feasible for thetreatment of recurrent lumbar disc herniation with pedicle screw fixation combined with contralateral translaminar facet screw fixation and interbody fusion. Compared with the median incision approach, the muscle-splitting approach has the advantages of small incision, less trauma, less bleeding, rapid recovery. Also it can protect multifidus and do not increase the incidence of serious complications. Thus, it can be used as a choice for fixation and fusion of recurrent lumbar disc herniation.


Assuntos
Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Parafusos Pediculares , Fusão Vertebral , Adulto , Feminino , Humanos , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Músculos , Estudos Retrospectivos , Resultado do Tratamento
15.
J Hazard Mater ; 403: 123286, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-32763635

RESUMO

In this study, efficient simultaneous degradation and dechlorination of the photo-recalcitrant emerging disinfection byproduct, 2-chlorophenol (2-CP), was achieved by vacuum-ultraviolet (VUV) system for the first time. Different from the conventional UV system, the combined action of direct photolysis and OH oxidation in VUV system led to a significantly higher removal efficiency for 2-CP. In UV system, 2-CP degradation rate constants was independent of the initial 2-CP concentration, and was increased with enhancing pH. To the contrary, in VUV system, higher initial concentration of 2-CP resulted in lower rate constant, and the degradation rates of 2-CP under both acidic and alkaline conditions were higher than that at the neutral pH. Moreover, humic acid could inhibit 2-CP degradation more prominently in VUV system than in UV system, owing to the scavenging effect of OH by it. The degradation pathways of 2-CP were proposed based on the identified main degradation products by GC-MS/MS. Furthermore, degradation of the other seven typical halogenated phenols by VUV irradiation in tap water, ultrafiltrated water and Mill-Q water were investigated to verify the feasibility of the system. Based on the systematic economic analysis, VUV process is economically feasible for the advanced treatment of tap water to remove halogenated phenols.

16.
Zhongguo Gu Shang ; 33(12): 1142-7, 2020 Dec 25.
Artigo em Chinês | MEDLINE | ID: mdl-33369322

RESUMO

OBJECTIVE: To analyze the causes of vascular injury occurred in oblique lateral interbody fusion for treating lumbar degenerative diseases, and put forward preventive measures. METHODS: There were 235 patients analyzed from October 2014 to May 2017 in five hospitals, who were treated with oblique lateral interbody fusion with or without posterior pedicle screw fixation. There were 79 males and 156 females with an average age of (61.9±13.5) years old (ranged from 32 to 83 years). There were 7 cases of vascular injury, including 4 cases of segmental vessel injury, 1 case of left common iliac artery injury, 1 case of left common iliac veininjury and 1 case of ovarian vein injury. RESULTS: The follow up time ranged from 6 to 36 months, averagely (15.6±7.5) months. There was no pedicle screw loosen or fracture. The low back pain VAS decreased from preoperative 6.7±2.3 to 1.4±0.8 at the latest follow-up, which was statistically difference(t=7.21, P=0.033). The ODI decreased from preoperative (36.5±7.7)% to (9.4±3.6)% at the latest follow-up, which was statistically difference (t=8.11, P=0.025). CONCLUSION: Oblique lateral interbody fusion technique provides a new method for minimally invasive fusion of lumbar internal fixation. However, it has a risk of vascular injury. In order to effectively prevent the occurrence of vascular injury, the operative indications and careful and meticulous operation should be strictly grasped.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Lesões do Sistema Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Vértebras Lombares/cirurgia , Região Lombossacral , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fusão Vertebral/efeitos adversos , Resultado do Tratamento , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle , Lesões do Sistema Vascular/cirurgia
17.
Nanomaterials (Basel) ; 10(9)2020 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-32859115

RESUMO

Copper nanoclusters (Cu NCs) are generally formed by several to dozens of atoms. Because of wide range of raw materials and cheap prices, Cu NCs have attracted scientists' special attention. However, Cu NCs tend to undergo oxidation easily. Thus, there is a dire need to develop a synthetic protocol for preparing fluorescent Cu NCs with high QY and better stability. Herein, we report a one-step method for preparing stable blue-green fluorescent copper nanoclusters using glutathione (GSH) as both a reducing agent and a stabilizing agent. High-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS) and electrospray ionization mass spectrometer (ESI-MS) were used to characterize the resulting Cu NCs. The as-prepared Cu NCs@GSH possess an ultrasmall size (2.3 ± 0.4 nm), blue-green fluorescence with decent quantum yield (6.2%) and good stability. MTT results clearly suggest that the Cu NCs@GSH are biocompatible. After incubated with EB-labeled HEK293T cells, the Cu NCs mainly accumulated in nuclei of the cells, suggesting that the as-prepared Cu NCs could potentially be used as the fluorescent probe for applications in cellular imaging.

18.
Nanomaterials (Basel) ; 10(8)2020 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-32759865

RESUMO

As one of the widely studied metal nanoclusters, the preparation of copper nanoclusters (Cu NCs) by a facile method with high fluorescence performance has been the interest of researchers. In this paper, a simple, green, clean, and time-saving chemical etching method was used to synthesize water-soluble Cu NCs using ascorbic acid (AA) as the reducing agent. The as-prepared Cu NCs showed strong green fluorescence (with a quantum yield as high as 33.6%) and high ion stability, and good antioxidant activity as well. The resultant Cu NCs were used for the detection of 4-aminoazobenzene (one of 24 kinds of prohibited textile compounds) in water with a minimum detection limit of 1.44 µM, which has good potential for fabric safety monitoring.

19.
Zhongguo Gu Shang ; 33(4): 337-47, 2020 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-32351088

RESUMO

OBJECTIVE: To explore the clinical effect of combined fixation and interbody bone grafting through intermuscular approach with different fusion cages in the treatment of single segment lumbar diseases. METHODS: From June 2014 to December 2016, the clinical data of 123 cases of single segment lumbar diseases were analyzed retrospectively, including 44 males and 79 females, aged 22 to 60 years old, with the diseases course of 6 to 84 months. The disease types involved lumbar disc degeneration in 65 cases, lumbar spinal stenosis in 30 cases, MeyerdingⅠslip in 21 cases, giant lumbar disc herniation in 7 cases. Lesions was L3, 4 in 5 cases, L4, 5 in 101 cases, L5S1 in 17 cases. According to the application of different interbody fusion cage, patients were divided into single common cage group, double common cage group and banana type cage group. The operation time, intraoperative hemorrhage, postoperative incision drainage fluid and incision length were observed in three groups; VAS score of lumbar incision and JOA score of preoperative and final follow up were recorded 72 hours after operation;the intervertebral space height, Cobb angle of lumbar coronal and sagittal plane before and after operation, and interbody fusion 12 months after operation were observed by imaging data. RESULTS: There was no significant difference in incision length, operation time, intraoperative bleeding volume, postoperative drainage volume and VAS score of lumbar incision 72 hours after operation among three groups (P>0.05). All cases were followed up for 12 to 36 (23.70±4.52) months. The height of intervertebral space in three groups recovered significantly (P<0.05), at the last follow-up, there were different degrees of loss, the loss degree of single common fusion cage group>banana type fusion cage group>double common fusion cage group. At the last follow-up, the Cobb angle in the coronaland sagittal planes of the three groups were significantly improved (P<0.05). During the follow-up, there were 42 cases of fusion cage subsidence, including 26 cases in the single common cage group, 5 cases in the double common cage group, 11 cases in the banana cage group, the difference was statistically significant (P<0.05). At 12 months after operation, the interbody fusion rate was 83% in the single common cage group, 95% in the double common cage group and 90% in the banana cage group, the interbody fusion rate in the two common cage group and the banana cage group was better than that in the single common cage group. No obvious degeneration was observed in the adjacent segments. At the last follow-up, the JOA scores of the three groups were statistically significant (P<0.05). The incidence of single common fusion cage group was 10%(4 / 42), that of double common fusion cage group was 9%(4 / 43), and that of banana fusion cage group was 10%(4 / 39). There was no significant difference among the three groups. CONCLUSION: Through the intermuscular approach, single pedicle screw and contralateral facet screw were used for fixation, and single common fusion cage, double common fusion cage or banana type fusion cage were used for interbody grafting to treat single segment lumbar disease. Although the application of different fusion cage could not increase the axial strength of fixed segment, the speed of fusion was accelerated by increasing the contact area, and the quality of the fusion cage reduces the settlement of the cage and the loss of the height of the intervertebral space. Therefore, two interbody fusion cages implanted in one side are of positive clinical significance for the fixation of unilateral pedicle screw combined with contralateral facet screw, without prolonging the operation time and increasing the complications.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
20.
Chem Commun (Camb) ; 56(23): 3433-3436, 2020 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-32100809

RESUMO

A new kind of oxygen-rich carbon microsphere with a nanoflake-interlaced architecture has been successfully prepared by a facile surfactant-assisted precipitation-polymerization method. This hierarchical infrastructure can efficiently buffer the volume change during the potassiation/depotassiation cycles.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA