1.
Rev Sci Instrum ; 92(9): 093506, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598546

RESUMO

A two-color homodyne Mach-Zehnder (M-Z) optical fiber interferometer with wavelengths of 1.55 and 1.31 µm was developed for long-time measurement of line-integrated plasma electron density. A novel phase difference demodulation algorithm based on a single 3 × 3 optical coupler was implemented in a two-color optical fiber interferometer scheme for the first time. Our laboratory tests showed that this new optical fiber interferometer could determine the phase shift due to the low-frequency ambient vibration and could maintain high phase resolution measurement. The resolution of the new interferometer was less than 0.04 rad in 1000 s, corresponding to a line-averaged electron density of less than 1.0 × 1019 m-2. Actual plasma discharge experiments performed on KTX-CTI, which is a new compact torus injector (CTI) constructed at the Keda Torus eXperiment (KTX), showed that this interferometer has excellent several-second stability.

2.
Rev Sci Instrum ; 91(6): 063501, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611014

RESUMO

An optical fiber Mach-Zehnder interferometer at a wavelength of 1.55 µm has been developed for measurements of high electron density on compact torus (CT) plasmas with a high time resolution of 0.1 µs and high phase resolution of 6.4 × 10-4 rad. To improve density measurement accuracy, the phase noise of the interferometer has been investigated in detail and optimized. In the bench test, the interferometer was calibrated using a piezoelectric ceramic actuator with known stroke. Initial results on CT plasma show that the optical fiber interferometer provides reliable density measurements at two spatial locations and the bulk velocity of plasma can be determined by the method of time of flight.

3.
Rev Sci Instrum ; 86(8): 083503, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26329188

RESUMO

An X-mode polarized V band (50 GHz-75 GHz) radial and poloidal correlation reflectometry is designed and installed on Experimental Advanced Superconducting Tokamak (EAST). Two frequency synthesizers (12 GHz-19 GHz) are used as sources. Signals from the sources are up-converted to V band using active quadruplers and then coupled together for launching through one single pyramidal antenna. Two poloidally separated antennae are installed to receive the reflected waves from plasma. This reflectometry system can be used for radial and poloidal correlation measurement of the electron density fluctuation. In ohmically heated plasma, the radial correlation length is about 1.5 cm measured by the system. The poloidal correlation analysis provides a means to estimate the fluctuation velocity perpendicular to the main magnetic field. In the present paper, the distance between two poloidal probing points is calculated with ray-tracing code and the propagation time is deduced from cross-phase spectrum. Fluctuation velocity perpendicular to the main magnetic field in the core of ohmically heated plasma is about from -1 km/s to -3 km/s.