Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(17)2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39275589

RESUMO

This review explores the emerging role of screen-printed electrodes (SPEs) in the detection of breast cancer biomarkers. We discuss the fundamental principles and fabrication techniques of SPEs, highlighting their adaptability and cost-effectiveness. The review examines various modification strategies, including nanomaterial incorporation, polymer coatings, and biomolecule immobilization, which enhance sensor performance. We analyze the application of SPEs in detecting protein, genetic, and metabolite biomarkers associated with breast cancer, presenting recent advancements and innovative approaches. The integration of SPEs with microfluidic systems and their potential in wearable devices for continuous monitoring are explored. While emphasizing the promising aspects of SPE-based biosensors, we also address current challenges in sensitivity, specificity, and real-world applicability. The review concludes by discussing future perspectives, including the potential for early screening and therapy monitoring, and the steps required for clinical implementation. This comprehensive overview aims to stimulate further research and development in SPE-based biosensors for improved breast cancer management.


Assuntos
Biomarcadores Tumorais , Técnicas Biossensoriais , Neoplasias da Mama , Eletrodos , Humanos , Neoplasias da Mama/diagnóstico , Biomarcadores Tumorais/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Feminino
2.
Biosensors (Basel) ; 14(8)2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39194615

RESUMO

Oxalic acid (OA) is a predominant constituent in kidney stones, contributing to 70-80% of all cases. Rapid detection of OA is vital for the early diagnosis and treatment of kidney stone conditions. This work introduces a novel electrochemical sensing approach for OA, leveraging vanadium disulfide (VS2) nanoflowers synthesized via hydrothermal synthesis. These VS2 nanoflowers, known for their excellent electrocatalytic properties and large surface area, are used to modify glassy carbon electrodes for enhanced OA sensing. The proposed OA sensor exhibits high sensitivity and selectivity across a wide linear detection range of 0.2-20 µM, with an impressively low detection limit of 0.188 µM. The practicality of this sensor was validated through interference studies, offering a promising tool for the early diagnosis and monitoring of kidney stone diseases.


Assuntos
Carbono , Técnicas Eletroquímicas , Eletrodos , Ácido Oxálico , Carbono/química , Limite de Detecção , Técnicas Biossensoriais , Nanoestruturas , Humanos , Compostos de Vanádio/química
3.
Sensors (Basel) ; 24(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38733009

RESUMO

Recent advancements in polymer-assisted layer-by-layer (LbL) fabrication have revolutionized the development of wearable sensors for health monitoring. LbL self-assembly has emerged as a powerful and versatile technique for creating conformal, flexible, and multi-functional films on various substrates, making it particularly suitable for fabricating wearable sensors. The incorporation of polymers, both natural and synthetic, has played a crucial role in enhancing the performance, stability, and biocompatibility of these sensors. This review provides a comprehensive overview of the principles of LbL self-assembly, the role of polymers in sensor fabrication, and the various types of LbL-fabricated wearable sensors for physical, chemical, and biological sensing. The applications of these sensors in continuous health monitoring, disease diagnosis, and management are discussed in detail, highlighting their potential to revolutionize personalized healthcare. Despite significant progress, challenges related to long-term stability, biocompatibility, data acquisition, and large-scale manufacturing are still to be addressed, providing insights into future research directions. With continued advancements in polymer-assisted LbL fabrication and related fields, wearable sensors are poised to improve the quality of life for individuals worldwide.


Assuntos
Técnicas Biossensoriais , Polímeros , Dispositivos Eletrônicos Vestíveis , Polímeros/química , Humanos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos
4.
Analyst ; 149(2): 386-394, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38050732

RESUMO

The presence of sulfamethoxazole (SMX) in natural waters has become a significant concern recently because of its detrimental effects on human health and the ecological environment. To address this issue, it is of utmost urgency to develop a reliable method that can determine SMX at ultra-low levels. In our research, we utilized PVP-induced shape control of a hydrothermal synthesis method to fabricate layer-like structured VS2, and employed it as an electrode modification material to prepare an electrochemical sensor for the sensitive determination of SMX. Thus, our prepared VS2 electrodes exhibited a linear range of 0.06-10.0 µM and a limit of detection (LOD) as low as 47.0 nM (S/N = 3) towards SMX detection. Additionally, the electrochemical sensor presented good agreement with the HPLC method, and afforded perfect recovery results (97.4-106.8%) in the practical analysis. The results validated the detection accuracy of VS2 electrodes, and demonstrated their successful applicability toward the sensitive determination of SMX in natural waters. In conclusion, this research provides a promising approach for the development of electrochemical sensors based on VS2 composite materials.


Assuntos
Antibacterianos , Compostos de Vanádio , Humanos , Sulfametoxazol , Técnicas Eletroquímicas/métodos , Eletrodos , Limite de Detecção
5.
Sensors (Basel) ; 23(20)2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37896749

RESUMO

Bisphenol A (BPA) is an industrial chemical used extensively in plastics and resins. However, its endocrine-disrupting properties pose risks to human health and the environment. Thus, accurate and rapid detection of BPA is crucial for exposure monitoring and risk mitigation. Molecularly imprinted electrochemical sensors (MIES) have emerged as a promising tool for BPA detection due to their high selectivity, sensitivity, affordability, and portability. This review provides a comprehensive overview of recent advances in MIES for BPA detection. We discuss the operating principles, fabrication strategies, materials, and methods used in MIES. Key findings show that MIES demonstrate detection limits comparable or superior to conventional methods like HPLC and GC-MS. Selectivity studies reveal excellent discrimination between BPA and structural analogs. Recent innovations in nanomaterials, novel monomers, and fabrication techniques have enhanced sensitivity, selectivity, and stability. However, limitations exist in reproducibility, selectivity, and stability. While challenges remain, MIES provide a low-cost portable detection method suitable for on-site BPA monitoring in diverse sectors. Further optimization of sensor fabrication and characterization will enable the immense potential of MIES for field-based BPA detection.


Assuntos
Impressão Molecular , Humanos , Impressão Molecular/métodos , Reprodutibilidade dos Testes , Técnicas Eletroquímicas/métodos , Plásticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA