Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Luminescence ; 21(1): 36-42, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16100747

RESUMO

A novel flow-injection method with chemiluminescence detection was developed for the determination of streptomycin residues in milk, based on the enhancement by streptomycin of the luminol-potassium periodate-Mn(2+) chemiluminescence system. The assay allowed analysis of streptomycin residues in whole milk samples ( approximately 3.5% fat) after sample work-up procedures. The limit of detection was 5.16 x 10(-9) mol/L for milk, and was far below the regulations of maximum residue limits (MRLs). The relative standard deviation (RSD) for 8.66 x 10(-8) mol/L streptomycin was 1.94% (n = 15) in milk. The results obtained for the assay of streptomycin residues in milk was comparable with those obtained by the official methods (ELISA) and demonstrated good accuracy and precision. The possible mechanism is briefly discussed.


Assuntos
Antibacterianos/análise , Resíduos de Drogas/análise , Análise de Injeção de Fluxo/métodos , Luminol/química , Manganês/química , Leite/química , Ácido Periódico/química , Estreptomicina/análise , Animais , Cinética
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 824(1-2): 57-64, 2005 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-16009603

RESUMO

A novel method was developed for the simultaneous determination of tetracycline antibiotic (TCA) residues such as oxytetracycline (OTC), tetracycline (TC), and metacycline (MTC) by high-performance liquid chromatography (HPLC) coupled with chemiluminescence (CL) detection. The procedure was based on the chemiluminescent enhancement by TCAs of the potassium permanganate-sodium sulfite-beta-cyclodextrin system in a phosphoric acid medium. The separation was carried out with an isocratic elution using a mixture of acetonitrile and 0.001 M phosphoric acid. For the three TCAs, the detection limits at a signal-to-noise of 3 ranged from 0.9 to 5.0 ng/ml. The relative standard deviations for the determination of TCAs ranged from 3.1 to 7.4% within a day (n=11) and ranged from 2.2 to 8.6% in 3 days (n=9), respectively. The method was successfully applied to the determination of TCA residues in honey samples. The possible mechanism of the CL reaction was also discussed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Mel/análise , Medições Luminescentes/métodos , Tetraciclinas/análise , Cromatografia Líquida de Alta Pressão/instrumentação , Medições Luminescentes/instrumentação , Metaciclina/análise , Metaciclina/química , Oxitetraciclina/análise , Oxitetraciclina/química , Permanganato de Potássio/química , Reprodutibilidade dos Testes , Sulfitos/química , Tetraciclinas/química , beta-Ciclodextrinas/química
3.
Luminescence ; 20(1): 8-15, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15685658

RESUMO

Tetracyclines (TCs) were found to strongly inhibit the electrochemiluminescence (ECL) from the Ru(bpy)3(2+)-tripropylamine system when a working Pt electrode was maintained at 1.05 V (vs. Ag/AgCl) in pH 8.0 carbonate buffer solution. On this basis, a flow injection (FI) procedure with inhibited electrochemiluminescence detection has been developed for the determination of tetracycline (TC) and oxytetracycline (OTC). Under the optimized condition, the linear ranges of 2.0 x 10(-8)-1.0 x 10(-5) and 1.0 x 10(-8)-1.0 x 10(-5) g/mL and the detection limits of 4.0 x 10(-9) and 3.8 x 10(-9) g/mL were obtained for TC and OTC, respectively. The relative standard deviations (RSD) were 0.68% and 1.18% for 5.0 x 10(-7) g/mL TC and OTC (n = 13), respectively. The method showed higher sensitivity than most of the reported methods. It was successfully applied to the determination of tetracycline in a Chinese proprietary medicine, Tetracyclini and Cortisone Eye Ointment, and the residues of tetracycline in honey products. The inhibition mechanism has been proposed due to an energy transfer between electrogenerated Ru(bpy)3(2+)* and benzoquinone derivatives at the electrode surface.


Assuntos
Eletroquímica/métodos , Análise de Injeção de Fluxo/métodos , Medições Luminescentes/métodos , Compostos Organometálicos/química , Propilaminas/química , Tetraciclinas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA