Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JAMA ; 331(12): 1015-1024, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38460161

RESUMO

Importance: Drug-coated balloons offer a potentially beneficial treatment strategy for the management of coronary in-stent restenosis. However, none have been previously evaluated or approved for use in coronary circulation in the United States. Objective: To evaluate whether a paclitaxel-coated balloon is superior to an uncoated balloon in patients with in-stent restenosis undergoing percutaneous coronary intervention. Design, Setting, and Participants: AGENT IDE, a multicenter randomized clinical trial, enrolled 600 patients with in-stent restenosis (lesion length <26 mm and reference vessel diameter >2.0 mm to ≤4.0 mm) at 40 centers across the United States between May 2021 and August 2022. One-year clinical follow-up was completed on October 2, 2023. Interventions: Participants were randomized in a 2:1 allocation to undergo treatment with a paclitaxel-coated (n = 406) or an uncoated (n = 194) balloon. Main Outcomes and Measures: The primary end point of 1-year target lesion failure-defined as the composite of ischemia-driven target lesion revascularization, target vessel-related myocardial infarction, or cardiac death-was tested for superiority. Results: Among 600 randomized patients (mean age, 68 years; 157 females [26.2%]; 42 Black [7%], 35 Hispanic [6%] individuals), 574 (95.7%) completed 1-year follow-up. The primary end point at 1 year occurred in 17.9% in the paclitaxel-coated balloon group vs 28.6% in the uncoated balloon group, meeting the criteria for superiority (hazard ratio [HR], 0.59 [95% CI, 0.42-0.84]; 2-sided P = .003). Target lesion revascularization (13.0% vs 24.7%; HR, 0.50 [95% CI, 0.34-0.74]; P = .001) and target vessel-related myocardial infarction (5.8% vs 11.1%; HR, 0.51 [95% CI, 0.28-0.92]; P = .02) occurred less frequently among patients treated with paclitaxel-coated balloon. The rate of cardiac death was 2.9% vs 1.6% (HR, 1.75 [95% CI, 0.49-6.28]; P = .38) in the coated vs uncoated balloon groups, respectively. Conclusions and Relevance: Among patients undergoing coronary angioplasty for in-stent restenosis, a paclitaxel-coated balloon was superior to an uncoated balloon with respect to the composite end point of target lesion failure. Paclitaxel-coated balloons are an effective treatment option for patients with coronary in-stent restenosis. Trial Registration: ClinicalTrials.gov Identifier: NCT04647253.


Assuntos
Reestenose Coronária , Infarto do Miocárdio , Feminino , Humanos , Idoso , Paclitaxel , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents , Resultado do Tratamento , Morte
2.
EuroIntervention ; 18(14): 1178-1187, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36373421

RESUMO

BACKGROUND: While intravascular imaging guidance during percutaneous coronary intervention (PCI) improves outcomes, routine intravascular imaging usage remains low, in part due to perceived inefficiency and safety concerns.  Aims: The LightLab (LL) Initiative was designed to evaluate whether implementing a standardised optical coherence tomography (OCT) workflow impacts PCI safety metrics and procedural efficiency. METHODS: In this multicentre, prospective, observational study, PCI procedural data were collected over 2 years from 45 physicians at 17 US centres. OCT-guided PCI incorporating the LL workflow (N=264), a structured algorithm using routine pre- and post-PCI OCT imaging, was compared with baseline angiography-only PCI (angio) (N=428). Propensity score analysis identified 207 matched procedures. Outcomes included procedure time, radiation exposure, contrast volume, device utilisation, and treatment strategy. RESULTS: Compared with angiography alone, LL workflow OCT-guided PCI increased the median procedural time by 9 minutes but reduced vessel preparation time (2 min LL workflow vs 3 min angio; p<0.001) and resulted in less unplanned additional treatment (4% LL workflow vs 10% angio; p=0.01). With LL workflow OCT guidance, fewer cineangiography views were needed compared to angiography guidance, leading to decreased radiation exposure (1,133 mGy LL workflow vs 1,269 mGy angio; p=0.02), with no difference in contrast utilisation between groups (p=0.28). Furthermore, LL workflow OCT guidance resulted in fewer predilatation balloons and stents being used, more direct stent placement, and greater stent post-dilatation than angiography-guided PCI. CONCLUSIONS: The incorporation of a standardised pre- and post-PCI OCT imaging workflow improves procedural efficiency and safety metrics, at a cost of a modestly longer procedure time.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Tomografia de Coerência Óptica/métodos , Angiografia Coronária/métodos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Fluxo de Trabalho , Resultado do Tratamento , Stents , Vasos Coronários/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Ultrassonografia de Intervenção/métodos
3.
4.
J Biol Chem ; 279(20): 21651-7, 2004 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-15007078

RESUMO

A serine (Ser-700) amino acid rather than an asparagine (Asn-700) at residue 700 of thrombospondin-1 has been linked to an increased risk for development of premature, familial heart attacks. We now have identified both functional and structural differences between the Ser-700 and Asn-700 thrombospondin-1 variants. The Ser-700 variant increased the rate and extent of platelet aggregation and showed increased surface expression on platelets compared with the Asn-700 variant. These differences could be ascribed to an enhanced interaction of the Ser-700 variant with fibrinogen on the platelet surface and are consistent with a prothrombotic phenotype in Ser-700 individuals. The Ser-700 variant thrombospondin-1 was conformationally more labile than the Asn-700 variant as demonstrated by increased susceptibility to proteolytic digestion and enhanced susceptibility to unfolding by denaturants. These data suggest a potential molecular and cellular basis for a genetic risk factor associated with early onset myocardial infarction.


Assuntos
Asparagina , Infarto do Miocárdio/genética , Polimorfismo de Nucleotídeo Único , Serina , Trombospondina 1/genética , Trombospondina 1/metabolismo , Dicroísmo Circular , Variação Genética , Humanos , Infarto do Miocárdio/epidemiologia , Agregação Plaquetária/genética , Agregação Plaquetária/fisiologia , Fatores de Risco , Trombospondina 1/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA