Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Interv Neuroradiol ; : 15910199241248479, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38706147

RESUMO

OBJECTIVE: There are few studies on flow diverters with diameters >5 mm. We present our preliminary experience with the 5.5-8 mm Derivo Embolization Device (DED) implants for the treatment of cerebral aneurysms. METHODS: A consecutive series of 26 patients (median age: 60 years) treated for 32 aneurysms in 26 procedures was retrospectively analyzed for procedural characteristics, complications, and mid-term angiographic results. RESULTS: The median aneurysm size was 10.5 mm, 2 of 30 (6%) aneurysms were ruptured and 9 (28%) had a fusiform or dissecting morphology. DED implantation was performed in the internal carotid artery in 18 of 26 (69%) procedures and in the vertebrobasilar artery in 8 (31%). Device deployment failed in 1 (4%) procedure. The 7 and 8 mm implants were successfully deployed in 5 cases. Additional balloon angioplasty or stent implantation was performed in 3 (12%) cases to improve wall apposition. Complications included 1 (4%) major stroke and 2 (8%) minor strokes. Angiographic follow up at a mean of 6 months showed complete occlusion in 8 of30 (27%) aneurysms and favorable occlusion in 14 (47%). CONCLUSIONS: The use of large diameter DEDs was safe and feasible. The mid-term occlusion rates are acceptable considering the complex subset of aneurysms studied. Further studies are warranted to define the indications for large-diameter DEDs and to evaluate their long-term efficacy.

2.
Clin Neuroradiol ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38814452

RESUMO

PURPOSE: This study analyzes the long-term clinical and angiographic outcomes of the Derivo Embolization Device (DED), an advanced flow diverter device with an electropolished surface, for the treatment of intracranial aneurysms. METHODS: A consecutive series of 101 patients (mean age: 58 years, 72% female) treated with the DED for 122 aneurysms at a single center between 2017 and 2023 was retrospectively analyzed for major (change in National Institutes of Health Stroke Scale [NIHSS] score ≥ 4 points) and minor (change in NIHSS score < 4 points) neurological events, procedural morbidity (increase of at least one point on the modified Rankin Scale), and angiographic results. RESULTS: There were 14 (11%) recurrent aneurysms, 15 (12%) ruptured aneurysms, 26 (21%) posterior circulation aneurysms and 16 (13%) fusiform or dissecting aneurysms. Device deployment failed in 1 case (1%). Procedure-related symptomatic procedural complications consisted of 2 (2%) major events (1 major stroke and 1 vessel perforation with intracranial hemorrhage and infarction) and 6 minor events (6 minor strokes). Procedural morbidity was 5%. There were no late ischemic or hemorrhagic events during follow-up. Complete and favorable aneurysm occlusion was achieved in 54% (40/74) and 62% (46/74) at a mean of 5 months, 71% (27/38) and 87% (33/38) at a mean of 12 months, and 76% (25/33) and 97% (32/33) at a mean of 35 months, respectively. CONCLUSION: The results demonstrate progressive aneurysm occlusion beyond 12 months after DED implantation with an almost 100% favorable occlusion rate. Procedural morbidity was low and there were no late complications.

3.
Radiologie (Heidelb) ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607391

RESUMO

OBJECTIVE: Mobile head computed tomography (CT) scanners can reduce transport-related complications in neurointensive care unit (NICU) patients and decrease the burden on NICU staff; however, the initial investment cost and reduced image quality of early mobile scanners have prevented their widespread clinical use. Here, we report our initial experience with a novel 32-row mobile CT scanner for use in NICUs. METHODS: Over a 2-year period, 107 patients received a mobile head CT scan. The technical characteristics of the scanner and the organizational procedures are described in detail. Patient characteristics were retrospectively collected and image quality was subjectively evaluated on a Likert scale ranging from 0 to 5 and compared with a stationary CT scanner. RESULTS: Mobile head CT was used for follow-up of intracranial hemorrhage in 51%, routine postoperative imaging in 28%, evaluation of neurological deterioration in 14%, bedside monitoring after external ventricular drain placement in 4%, and follow-up of ischemic stroke in 3% of cases. Diagnostic imaging quality was achieved in all cases, eliminating the need for stationary CT scanning. The overall image quality of mobile CT (median 4 points) was inferior to that of conventional stationary CT (median 5 points, p < 0.01), but was rated with 4 or 5 points in the majority of cases. CONCLUSIONS: State-of-the-art mobile CT was found to be easy to use and maneuver and has the potential to expedite the diagnosis of NICU patients and reduce staff workload. Image quality was adequate for common NICU issues.

4.
J Neurointerv Surg ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38569886

RESUMO

BACKGROUND: This multicenter study evaluated the safety and efficacy of coated flow diverters (cFDs) for the treatment of ruptured intracranial aneurysms. METHODS: Consecutive patients treated with different cFDs for ruptured aneurysms under tirofiban at eight neurovascular centers between 2016 and 2023 were retrospectively analyzed. The majority of patients were loaded with dual antiplatelet therapy after the treatment. Aneurysm occlusion was determined using the O'Kelly-Marotta (OKM) grading scale. Primary outcome measures were major procedural complications and aneurysmal rebleeding during hospitalization. RESULTS: The study included 60 aneurysms (posterior circulation: 28 (47%)) with a mean size of 5.8±4.7 mm. Aneurysm morphology was saccular in 28 (47%), blister-like in 12 (20%), dissecting in 13 (22%), and fusiform in 7 (12%). Technical success was 100% with a mean of 1.1 cFDs implanted per aneurysm. Adjunctive coiling was performed in 11 (18%) aneurysms. Immediate contrast retention was observed in 45 (75%) aneurysms. There was 1 (2%) major procedural complication (a major stroke, eventually leading to death) and no aneurysmal rebleeding. A good outcome (modified Rankin Scale 0-2) was achieved in 40 (67%) patients. At a mean follow-up of 6 months, 27/34 (79%) aneurysms were completely occluded (OKM D), 3/34 (9%) had an entry remnant (OKM C), and 4/34 (12%) had residual filling (OKM A or B). There was 1 (3%) severe in-stent stenosis during follow-up that was treated with balloon angioplasty. CONCLUSIONS: Treatment of ruptured aneurysms with cFDs was reasonably safe and efficient and thus represents a valid treatment option, especially for complex cases.

5.
J Clin Neurosci ; 124: 94-101, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38678972

RESUMO

OBJECTIVE: Overdrainage and frequent reprogramming are common problems with programmable valves after ventriculoperitoneal shunt surgery for idiopathic normal pressure hydrocephalus (iNPH). Non-adjustable, flow-regulated valves offer a potential solution to these problems, but there is limited data on their efficacy. This study will evaluate neurological improvement and overdrainage rates within one year of treatment with a flow-regulated valve. PATIENTS AND METHODS: This prospective study analyzes 45 iNPH patients (median age: 73 years) treated with a flow-regulated valve. Clinical evaluations were performed at baseline, postoperatively, and at 3, 6, and 12 months after surgery. The primary efficacy endpoint was improvement of at least 5 points on the iNPH grading scale at follow-up. The safety endpoint was radiographic evidence of overdrainage. RESULTS: All patients presented with gait disturbance, 35 (78 %) had cognitive impairment, and 35 (78 %) had urinary incontinence. The median duration of symptoms was 24 months. The total iNPH score improved in 33/41 (81 %) at 3 months, in 29/34 (85 %) at 6 months, and in 22/29 (64 %) at 12 months. Overall, 40/45 (89 %) patients had a significant improvement on the iNPH scale. Secondary worsening of symptoms after initial improvement was observed in 5 (11 %) patients. Overdrainage occurred in one patient (2 %) requiring surgical evacuation. CONCLUSION: Treatment of iNPH patients with flow-regulated valves resulted in a good neurological outcome with minimal rates of overdrainage. These results are encouraging and justify the clinical use of these valve types.


Assuntos
Hidrocefalia de Pressão Normal , Derivação Ventriculoperitoneal , Humanos , Hidrocefalia de Pressão Normal/cirurgia , Idoso , Feminino , Masculino , Estudos Prospectivos , Idoso de 80 Anos ou mais , Derivação Ventriculoperitoneal/métodos , Resultado do Tratamento , Pessoa de Meia-Idade , Seguimentos
6.
Eur J Radiol ; 175: 111447, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38677039

RESUMO

OBJECTIVES: Robustness of radiomic features in physiological tissue is an important prerequisite for quantitative analysis of tumor biology and response assessment. In contrast to previous studies which focused on different tumors with mostly short scan-re-scan intervals, this study aimed to evaluate the robustness of radiomic features in cancer-free patients and over a clinically encountered inter-scan interval. MATERIALS AND METHODS: Patients without visible tumor burden who underwent at least two portal-venous phase dual energy CT examinations of the abdomen between May 2016 and January 2020 were included, while macroscopic tumor burden was excluded based upon follow-up imaging for all patients (≥3 months). Further, patients were excluded if no follow-up imaging was available, or if the CT protocol showed deviations between repeated examinations. Circular regions of interest were placed and proofread by two board-certified radiologists (4 years and 5 years experience) within the liver (segments 3 and 6), the psoas muscle (left and right), the pancreatic head, and the spleen to obtain radiomic features from normal-appearing organ parenchyma using PyRadiomics. Radiomic feature robustness was tested using the concordance correlation coefficient with a threshold of 0.75 considered indicative for deeming a feature robust. RESULTS: In total, 160 patients with 480 repeated abdominal CT examinations (range: 2-4 per patient) were retrospectively included in this single-center, IRB-approved study. Considering all organs and feature categories, only 4.58 % (25/546) of all features were robust with the highest rate being found in the first order feature category (20.37 %, 22/108). Other feature categories (grey level co-occurrence matrix, grey level dependence matrix, grey level run length matrix, grey level size zone matrix, and neighborhood gray-tone difference matrix) yielded an overall low percentage of robust features (range: 0.00 %-1.19 %). A subgroup analysis revealed the reconstructed field of view and the X-ray tube current as determinants of feature robustness (significant differences in subgroups for all organs, p < 0.001) as well as the size of the region of interest (no significant difference for the pancreatic head with p = 0.135, significant difference with p < 0.001 for all other organs). CONCLUSION: Radiomic feature robustness obtained from cancer-free subjects with repeated examinations using a consistent protocol and CT scanner was limited, with first order features yielding the highest proportion of robust features.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Adulto , Estudos Retrospectivos , Pâncreas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Radiografia Abdominal/métodos , Idoso de 80 Anos ou mais , Baço/diagnóstico por imagem , Tecido Parenquimatoso/diagnóstico por imagem , Músculos Psoas/diagnóstico por imagem , Radiômica
7.
Sci Rep ; 14(1): 6393, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493258

RESUMO

The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.


Assuntos
Tomografia Computadorizada por Raios X , Substância Branca , Humanos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Crânio/diagnóstico por imagem , Doses de Radiação
8.
Sci Rep ; 14(1): 6154, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38486099

RESUMO

Intra-arterial nimodipine administration is a widely used rescue therapy for cerebral vasospasm. Although it is known that its effect sets in with delay, there is little evidence in current literature. Our aim was to prove that the maximal vasodilatory effect is underestimated in direct angiographic controls. We reviewed all cases of intra-arterial nimodipine treatment for subarachnoid hemorrhage-related cerebral vasospasm between January 2021 and December 2022. Inclusion criteria were availability of digital subtraction angiography runs before and after nimodipine administration and a delayed run for the most affected vessel at the end of the procedure to decide on further escalation of therapy. We evaluated nimodipine dose, timing of administration and vessel diameters. Delayed runs were performed in 32 cases (19 patients) with a mean delay of 37.6 (± 16.6) min after nimodipine administration and a mean total nimodipine dose of 4.7 (± 1.2) mg. Vessel dilation was more pronounced in delayed vs. immediate controls, with greater changes in spastic vessel segments (n = 31: 113.5 (± 78.5%) vs. 32.2% (± 27.9%), p < 0.0001) vs. non-spastic vessel segments (n = 32: 23.1% (± 13.5%) vs. 13.3% (± 10.7%), p < 0.0001). In conclusion intra-arterially administered nimodipine seems to exert a delayed vasodilatory effect, which should be considered before escalation of therapy.


Assuntos
Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Nimodipina/farmacologia , Vasodilatadores/uso terapêutico , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/tratamento farmacológico , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/tratamento farmacológico , Angiografia Digital
9.
Radiology ; 310(2): e232044, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38319166

RESUMO

Background CT-guided high-dose-rate (HDR) brachytherapy (hereafter, HDR brachytherapy) has been shown to be safe and effective for patients with unresectable hepatocellular carcinoma (HCC), but studies comparing this therapy with other local-regional therapies are scarce. Purpose To compare patient outcomes of HDR brachytherapy and transarterial chemoembolization (TACE) in patients with unresectable HCC. Materials and Methods This multi-institutional retrospective study included consecutive treatment-naive adult patients with unresectable HCC who underwent either HDR brachytherapy or TACE between January 2010 and December 2022. Overall survival (OS) and progression-free survival (PFS) were compared between patients matched for clinical and tumor characteristics by propensity score matching. Not all patients who underwent TACE had PFS available; thus, a different set of patients was used for PFS and OS analysis for this treatment. Hazard ratios (HRs) were calculated from Kaplan-Meier survival curves. Results After propensity matching, 150 patients who underwent HDR brachytherapy (median age, 71 years [IQR, 63-77 years]; 117 males) and 150 patients who underwent TACE (OS analysis median age, 70 years [IQR, 63-77 years]; 119 male; PFS analysis median age, 68 years [IQR: 63-76 years]; 119 male) were analyzed. Hazard of death was higher in the TACE versus HDR brachytherapy group (HR, 4.04; P < .001). Median estimated PFS was 32.8 months (95% CI: 12.5, 58.7) in the HDR brachytherapy group and 11.6 months (95% CI: 4.9, 22.7) in the TACE group. Hazard of disease progression was higher in the TACE versus HDR brachytherapy group (HR, 2.23; P < .001). Conclusion In selected treatment-naive patients with unresectable HCC, treatment with CT-guided HDR brachytherapy led to improved OS and PFS compared with TACE. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Chapiro in this issue.


Assuntos
Braquiterapia , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Adulto , Idoso , Humanos , Masculino , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
10.
Rofo ; 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38176436

RESUMO

BACKGROUND: Dual-energy CT (DECT) has been available for more than 15 years and has undergone continuous technical development and refinement. Recently, the first photon-counting CT scanner became clinically available and has the potential to further expand the possibilities of spectral imaging. Numerous studies on DECT have been published since its creation, highlighting the clinical applications of the various reconstructions enabled by DECT. METHODS: The aim of this focused review is to succinctly summarize basic principles and available technical concepts of DECT and to discuss established applications relevant to the daily clinical routine. RESULTS/CONCLUSION: DECT is instrumental for a broad variety of clinical use cases. While some DECT applications can enhance day-to-day clinical practice, others are still subject to broad-scale validation and should therefore be handled with restraint in the clinical routine. KEY POINTS: · Virtual monoenergetic images, virtual unenhanced images, and iodine maps are the most well-investigated and relevant dual-energy CT reconstructions for clinical application.. · Low-keV virtual monoenergetic images (VMIs) yield superior image and iodine contrast, which can be leveraged for improved vessel assessment and lesion conspicuity, or to reduce contrast media or radiation dose. VMIs at intermediate energies can serve as a replacement for conventional grey-scale images. VMIs at high keV enable efficient artifact reduction, which can be further optimized in combination with dedicated metal artifact reduction algorithms.. · Iodine maps and virtual unenhanced images can improve lesion detection in oncologic imaging and enable lesion assessment in monophasic CT examinations, which may allow a reduction of correlative and follow-up imaging..

11.
World Neurosurg ; 181: e182-e191, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37777172

RESUMO

OBJECTIVE: Several studies have demonstrated a high safety and efficacy profile of the Woven EndoBridge (WEB) for endovascular aneurysm treatment. However, contemporary large-scale studies of the WEB are rare. This multicenter study attempts to set a benchmark for state-of-the-art WEB treatment with consistent application of the WEB oversizing technique. METHODS: This is a retrospective, multicenter study of aneurysms (dome width 2-10 mm) treated with the WEB between 2015 and 2023. Patient and aneurysm characteristics, complications, and clinical and angiographic outcomes were analyzed. RESULTS: The study consisted of 247 patients treated for 251 aneurysms (25.5% ruptured, 5.6% recurrent). WEB implantation was feasible in 98.8%, achieving a mean WEB/dome ratio of 1.2 ± 0.1. The thromboembolic complication rate was 7.2%, which was higher in ruptured versus unruptured aneurysms (hazard ratio: 2.8, 95%CI: 1.0-7.6, P = 0.04), but lower in cases where WEB 17 was used (hazard ratio: 4.0, 95%CI: 1.4-11.2, P = 0.01). Neurological complications occurred in 8 procedures (3.2%), including 3 (1.2%) major, and 5 (2.0%) minor events. Procedural morbidity and mortality were 0.8% and 0%, respectively. Mid-term complete and adequate occlusion rates were 66.3% and 88.4%, respectively. The retreatment rate was 5.2%. Feasibility, complication, and occlusion rates were comparable between typical and atypical aneurysm locations. CONCLUSIONS: Oversizing the WEB and using currently available WEB types in this series resulted in slightly better treatment outcomes compared to early WEB studies, confirming the high safety, feasibility, and efficacy of this technique.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Embolização Terapêutica/métodos
12.
World Neurosurg ; 182: e517-e524, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043742

RESUMO

OBJECTIVE: In preliminary studies, advanced intracranial stents appear to have a favorable safety profile for intracranial aneurysm treatment. This dual-center study is a head-to-head comparison of the low-profile Acandis Acclino stent (a third-generation stent) and the first- and second-generation Enterprise stent. METHODS: Patients who underwent stent-assisted coiling with either the Enterprise or the Acclino stent for unruptured aneurysms during an 8-year period were enrolled and compared for complications, clinical outcomes, and angiographic results. Primary outcome measures were ischemic stroke rate and mid-term complete occlusion rate. Propensity score adjustment was performed to account for small differences between the groups. RESULTS: Enterprise and Acclino stents were used in 48 cases each. The overall rate of thrombotic complications was higher in the Enterprise group than in the Acclino group (20.8% vs. 4.2%, HR: 6.6, 95%CI: 2.2-20.0, P = 0.01, adjusted P < 0.01), which translated into a higher rate of major ischemic stroke after Enterprise treatment (6.3% vs. 0%, HR: 2.1, 95%CI: 1.8-2.4, P = 0.08, adjusted P < 0.01). Mid-term and long-term angiographic follow-up showed complete occlusion rates of 83.3% and 75.0% for Enterprise and 89.2% and 75.9% for Acclino (both P > 0.05). Retreatment rates were 10.4% in the Enterprise group and 4.2% in the Acclino group (P = 0.42, adjusted P = 0.10). CONCLUSIONS: The results indicate a favorable safety profile of the Acclino over the Enterprise, justifying the use of advanced stent systems in clinical practice. However, further comparative studies of the Acclino and other competing stent systems are needed to draw a definitive conclusion on the state of stent-assisted coiling.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , AVC Isquêmico , Humanos , Resultado do Tratamento , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Stents , Embolização Terapêutica/métodos , Angiografia Cerebral , AVC Isquêmico/terapia
13.
World Neurosurg ; 183: e210-e217, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38101543

RESUMO

OBJECTIVE: The Pipeline Vantage Embolization Device is a fourth-generation flow diverter with an antithrombotic coating and a reduced profile compared to previous Pipeline versions. The objective of this study was to evaluate the procedural feasibility, safety, and efficacy of this device. METHODS: The Pipe-VADER study was designed as a retrospective, observational study of consecutive patients treated with the Vantage at 3 neurovascular centers. Patient and aneurysm characteristics, procedural parameters, early complications, and extent of postinterventional contrast retention were analyzed on an intention-to-treat basis. RESULTS: Twenty-eight patients with 31 aneurysms (median size: 5.0 mm, posterior circulation: 4 [12.9%], ruptured: 5 [16.1%]) were included. The technical success rate was 100%, with multiple stents used in 4/30 (13.3%) procedures. Of the 30 procedures, adjunctive coiling was performed in 3 (10.0%) and balloon angioplasty in 2 (6.7%). Median procedure time was 62 minutes. Procedural ischemic stroke occured in 4 (13.3%) cases, whereof 2 were major strokes (6.6%). There were no hemorrhagic complications. Initial contrast retention was observed in 29/31 (93.5%) aneurysms. All 27 overstented side vessels were patent at the end of the procedure. Short-term follow-up (median: 5 months) showed complete and favorable occlusion rates of 70% (14/20) and 80% (16/20), respectively. CONCLUSIONS: The new Pipeline Vantage appears to be safe and feasible for the treatment of intracranial aneurysms and warrants further evaluation.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Embolização Terapêutica/métodos , Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents , Procedimentos Endovasculares/métodos , Seguimentos
14.
Diagnostics (Basel) ; 13(17)2023 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-37685359

RESUMO

This study aimed to compare the image quality and diagnostic accuracy of deep-learning-based image denoising reconstructions (DLIDs) to established iterative reconstructed algorithms in low-dose computed tomography (LDCT) of patients with suspected urolithiasis. LDCTs (CTDIvol, 2 mGy) of 76 patients (age: 40.3 ± 5.2 years, M/W: 51/25) with suspected urolithiasis were retrospectively included. Filtered-back projection (FBP), hybrid iterative and model-based iterative reconstruction (HIR/MBIR, respectively) were reconstructed. FBP images were processed using a Food and Drug Administration (FDA)-approved DLID. ROIs were placed in renal parenchyma, fat, muscle and urinary bladder. Signal- and contrast-to-noise ratios (SNR/CNR, respectively) were calculated. Two radiologists evaluated image quality on five-point Likert scales and urinary stones. The results showed a progressive decrease in image noise from FBP, HIR and DLID to MBIR with significant differences between each method (p < 0.05). SNR and CNR were comparable between MBIR and DLID, while it was significantly lower in HIR followed by FBP (e.g., SNR: 1.5 ± 0.3; 1.4 ± 0.4; 1.0 ± 0.3; 0.7 ± 0.2, p < 0.05). Subjective analysis confirmed best image quality in MBIR, followed by DLID and HIR, both being superior to FBP (p < 0.05). Diagnostic accuracy for urinary stone detection was best using MBIR (0.94), lowest using FBP (0.84) and comparable between DLID (0.90) and HIR (0.90). Stone size measurements were consistent between all reconstructions and showed excellent correlation (r2 = 0.958-0.975). In conclusion, MBIR yielded the highest image quality and diagnostic accuracy, with DLID producing better results than HIR and FBP in image quality and matching HIR in diagnostic precision.

15.
Interv Neuroradiol ; : 15910199231199131, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37671458

RESUMO

OBJECTIVE: The low-profile Acandis Acclino flex plus (AFP) is a fourth-generation laser-cut microstent with a flexible structure designed for the treatment of a wide variety of aneurysms. We report our single-center experience with this device in the treatment of complex aneurysms. METHODS: Twenty-eight patients were treated with the Acclino flex plus for 28 aneurysms. Aneurysm characteristics, technical success, complications, clinical outcome, and angiographic results were retrospectively analyzed. RESULTS: The cohort included 8 unruptured untreated aneurysms, 9 unruptured recurrent aneurysms, and 12 ruptured aneurysms with aneurysm diameters ranging from 3 to 23 mm. The anterior communicating artery was the most common location (52%). Stent deployment was successful in 28 cases (97%) with an average of 1.3 stents per aneurysm. The overall procedural complication rate was 17%, including 2 (6.8%) major clinical events (one ischaemic stroke and one aneurysm perforation) and one (3.4%) minor clinical event (one seizure). Angiographic results of 23 aneurysms at a mean of 6 months were complete occlusion in 74%, neck remnants in 13% and aneurysm remnants in 13%. Three patients were retreated. CONCLUSIONS: Given the complexity of the aneurysms, the use of the Acclino flex plus was feasible and associated with a favourable safety and efficacy profile. Further studies are needed to evaluate Acclino flex plus in other aneurysm subsets and to define its role in endovascular aneurysm treatment.

16.
Interv Neuroradiol ; : 15910199231193577, 2023 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-37574801

RESUMO

OBJECTIVE: The development of new flow-diverting devices with antithrombotic coatings may result in an improved safety profile, particularly a reduction in ischaemic stroke rates. The aim of this study was to evaluate our initial experience with the recently introduced coated Derivo® 2heal® Embolization Device (Acandis, Pforzheim, Germany). METHODS: This is a retrospective, single-centre analysis of patients with intracranial aneurysms undergoing Derivo® 2heal® Embolization Device treatment. Patient and aneurysm characteristics, procedural parameters, complications, and degree of initial and short-term aneurysm occlusion were evaluated on an intention-to-treat basis. RESULTS: A total of 16 unruptured aneurysms in 9 patients were treated with the Derivo® 2heal® Embolization Device in 10 treatment sessions. In one case the Derivo® 2heal® Embolization Device could not be deployed due to severe friction in the microcatheter. In all successful cases, one Derivo® 2heal® Embolization Device was sufficient to treat the target aneurysm and no additional coiling was performed. In-stent balloon angioplasty was performed in one procedure (10%) to improve vessel wall apposition. Twelve arterial side branches were covered in 9 procedures and all were patent at the end of the procedure. There were no clinical complications and no thromboembolic events during treatment. At the end of the procedure, contrast retention was observed in 13/16 (81%) aneurysms and at short-term follow-up, 6/9 (67%) were completely occluded. CONCLUSIONS: The preliminary results of the new Derivo® 2heal® Embolization Device appear promising and warrant further evaluation by multicentre studies with long-term follow-up.

17.
Front Endocrinol (Lausanne) ; 14: 1098898, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37274340

RESUMO

Purpose: The bone marrow's iodine uptake in dual-energy CT (DECT) is elevated in malignant disease. We aimed to investigate the physiological range of bone marrow iodine uptake after intravenous contrast application, and examine its dependence on vBMD, iodine blood pool, patient age, and sex. Method: Retrospective analysis of oncological patients without evidence of metastatic disease. DECT examinations were performed on a spectral detector CT scanner in portal venous contrast phase. The thoracic and lumbar spine were segmented by a pre-trained neural network, obtaining volumetric iodine concentration data [mg/ml]. vBMD was assessed using a phantomless, CE-certified software [mg/cm3]. The iodine blood pool was estimated by ROI-based measurements in the great abdominal vessels. A multivariate regression model was fit with the dependent variable "median bone marrow iodine uptake". Standardized regression coefficients (ß) were calculated to assess the impact of each covariate. Results: 678 consecutive DECT exams of 189 individuals (93 female, age 61.4 ± 16.0 years) were evaluated. AI-based segmentation provided volumetric data of 97.9% of the included vertebrae (n=11,286). The 95th percentile of bone marrow iodine uptake, as a surrogate for the upper margin of the physiological distribution, ranged between 4.7-6.4 mg/ml. vBMD (p <0.001, mean ß=0.50) and portal vein iodine blood pool (p <0.001, mean ß=0.43) mediated the strongest impact. Based thereon, adjusted reference values were calculated. Conclusion: The bone marrow iodine uptake demonstrates a distinct profile depending on vBMD, iodine blood pool, patient age, and sex. This study is the first to provide the adjusted reference values.


Assuntos
Inteligência Artificial , Iodo , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Medula Óssea/diagnóstico por imagem , Valores de Referência , Tomografia Computadorizada por Raios X
18.
World Neurosurg ; 2023 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-37356486

RESUMO

OBJECTIVE: Contrary to previous assumptions, there is increasing evidence that small intracranial aneurysms carry a relevant risk of rupture. The aim of this study was to identify angiographic characteristics of small ruptured aneurysms ≤7 mm and to evaluate their significance for clinical decision making. METHODS: A total of 385 patients with 149 unruptured and 236 ruptured intracranial aneurysms were retrospectively compared. Two- and three-dimensional digital subtraction angiography was used to determine aneurysm location, various size parameters, angulations, and morphology, as well as parent artery diameter. RESULTS: Aneurysms of the anterior communicating artery, the posterior inferior cerebellar artery, and the internal carotid artery terminus had a significantly increased prevalence among ruptured aneurysms. Ruptured aneurysms were characterized by a significantly larger aneurysm height (area under the curve [AUC] 0.60, P < 0.01) and aneurysm inclination angle (AUC 0.61, P = 0.02) in addition to a smaller dome (AUC 0.44, P = 0.02) and neck width (AUC 0.38, P < 0.01). Calculation of size ratios increases the predictive value for aneurysm rupture, with AUC values of 0.77 for aspect ratio (P < 0.01) and 0.76 for size ratio (P < 0.01). Aneurysm morphology was not a significant factor after multivariable adjustment (P = 0.20). Arterial hypertension was the only clinical risk factor significantly associated with rupture (P < 0.01). CONCLUSIONS: Of the numerous factors associated with aneurysm rupture, we propose aneurysmal location, aspect ratio (cut-off: 1.5), and aneurysm inclination angle as the most important morphological factors for assessing the rupture risk of small aneurysms because these factors have high AUC values and are robust to changes after rupture.

19.
Eur Radiol ; 33(2): 1031-1039, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35986768

RESUMO

OBJECTIVES: Low bone mineral density (BMD) was recently identified as a novel risk factor for patients with hepatocellular carcinoma (HCC). In this multicenter study, we aimed to validate the role of BMD as a prognostic factor for patients with HCC undergoing transarterial chemoembolization (TACE). METHODS: This retrospective multicenter trial included 908 treatment-naïve patients with HCC who were undergoing TACE as a first-line treatment, at six tertiary care centers, between 2010 and 2020. BMD was assessed by measuring the mean Hounsfield units (HUs) in the midvertebral core of the 11th thoracic vertebra, on contrast-enhanced computer tomography performed before treatment. We assessed the influence of BMD on median overall survival (OS) and performed multivariate analysis including established estimates for survival. RESULTS: The median BMD was 145 HU (IQR, 115-175 HU). Patients with a high BMD (≥ 114 HU) had a median OS of 22.2 months, while patients with a low BMD (< 114 HU) had a lower median OS of only 16.2 months (p < .001). Besides albumin, bilirubin, tumor number, and tumor diameter, BMD remained an independent prognostic factor in multivariate analysis. CONCLUSIONS: BMD is an independent predictive factor for survival in elderly patients with HCC undergoing TACE. The integration of BMD into novel scoring systems could potentially improve survival prediction and clinical decision-making. KEY POINTS: • Bone mineral density can be easily assessed in routinely acquired pre-interventional computed tomography scans. • Bone mineral density is an independent predictive factor for survival in elderly patients with HCC undergoing TACE. • Thus, bone mineral density is a novel imaging biomarker for prognosis prediction in elderly patients with HCC undergoing TACE.


Assuntos
Doenças Ósseas Metabólicas , Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Prognóstico , Quimioembolização Terapêutica/métodos , Estudos Retrospectivos , Resultado do Tratamento
20.
Eur J Radiol ; 157: 110583, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36371948

RESUMO

PURPOSE: To assess the diagnostic value of spectral-detector CT (SDCT) derived virtual non-contrast images (VNC) for differentiation between vascular enhancement and wall calcifications of cystic intracranial tumors in contrast-enhanced stereotactic planning examinations. METHOD: 48 patients with cystic intracranial tumors who underwent stereotactic SDCT examinations between 02/2017 and 02/2020 were retrospectively included. In each patient, two separate hyperattenuating structures along the cyst wall were defined as either enhancement or calcification, respectively, using reference MRI examinations. Quantitative analysis was performed ROI-based in conventional images (CI) and VNC. In the subjective analysis, two radiologists diagnosed the predefined peri-cystic structures in binary decisions as either enhancement or calcification using CI and the combination of CI and VNC, and rated diagnostic confidence, image noise and removal of iodine in VNC. Moreover, a potential diagnostic benefit of VNC was indicated. RESULTS: Attenuation in CI was higher as compared to VNC across all assessed ROI (all p < 0.01). In VNC, CNR between calcification and white matter was significantly higher as compared to CNR between vascular enhancement and white matter (2.6 vs 1.3, p < 0.01), while there was no significant difference in CI. In the qualitative assessment, diagnostic accuracy was significantly higher using both VNC and CI compared to using CI alone. Raters reported less image noise in VNC as compared to CI. An additional diagnostic benefit of VNC was indicated in 84.4 % of all cases. CONCLUSIONS: SDCT-derived VNC images facilitate differentiation between peri-cystic contrast enhancement in blood vessels and calcifications in stereotactic planning scans of cystic intracranial tumors.


Assuntos
Neoplasias Encefálicas , Calcinose , Iodo , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Calcinose/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA