Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Polymers (Basel) ; 16(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38475308

RESUMO

Recent studies have shown that astronauts experience altered immune response behavior during spaceflight, resulting in heightened susceptibility to illness. Resources and resupply shuttles will become scarcer with longer duration spaceflight, limiting access to potentially necessary medical treatment and facilities. Thus, there is a need for preventative health countermeasures that can exploit in situ resource utilization technologies during spaceflight, such as additive manufacturing (i.e., 3D printing). The purpose of the current study was to test and validate recyclable antimicrobial materials compatible with additive manufacturing. Antimicrobial poly(lactic acid)- and polyurethane-based materials compatible with 3D printing were assessed for antimicrobial, mechanical, and chemical characteristics before and after one closed-loop recycling cycle. Our results show high biocidal efficacy (>90%) of both poly(lactic acid) and polyurethane materials while retaining efficacy post recycling, except for recycled-state polyurethane which dropped from 98.91% to 0% efficacy post 1-year accelerated aging. Significant differences in tensile and compression characteristics were observed post recycling, although no significant changes to functional chemical groups were found. Proof-of-concept medical devices developed show the potential for the on-demand manufacturing and recyclability of typically single-use medical devices using antimicrobial materials that could serve as preventative health countermeasures for immunocompromised populations, such as astronauts during spaceflight.

2.
Children (Basel) ; 10(8)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37628286

RESUMO

The main objective of this study was to describe the cortical patterns of brain activity during a gross dexterity task and develop a behavioral profile of children experiencing isolation. A cross-sectional assessment was conducted during one visit. Sample: Four pediatric patients who had undergone isolation within a hospital comprised the full data collection. During the collection, participants completed the Box and Blocks Test of gross manual dexterity while undergoing imaging of the motor cortex using functional near-infrared spectroscopy. Participants also completed a Behavioral Assessment System for Children, Third Edition (BASC-3) self-report, which was analyzed along with a parent report to quantify their emotional and social behaviors. All participants displayed lower gross dexterity levels than normative data. Furthermore, three out of the four participants displayed ipsilateral dominance of the motor cortex during the dexterity task. Three of the participants displayed behavioral measures reported within clinically significant or at-risk scores. Clinically significant behavioral scores coupled with lower than expected manual dexterity values and ipsilateral hemispheric dominance indicate that neuroplastic changes can occur in populations undergoing hospitalized isolation. While the impacts of the treatments and isolation in this case cannot be separated, further studies should be conducted to understand these impacts of isolation.

3.
Front Rehabil Sci ; 4: 1156940, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37266515

RESUMO

Introduction: A short-term immobilization of one hand affects musculoskeletal functions, and the associated brain network adapts to the alterations happening to the body due to injuries. It was hypothesized that the injury-associated temporary disuse of the upper limb would alter the functional interactions of the motor cortical processes and will produce long-term changes throughout the immobilization and post-immobilization period. Methods: The case participant (male, 12 years old, right arm immobilized for clavicle fracture) was scanned using optical imaging technology of fNIRS over immobilization and post-immobilization. Pre-task data was collected for 3 min for RSFC analysis, processed, and analyzed using the Brain AnalyzIR toolbox. Connectivity was measured using Pearson correlation coefficients (R) from NIRS Toolbox's connectivity module. Results: The non-affected hand task presented an increased ipsilateral response during the immobilization period, which then decreased over the follow-up visits. The right-hand task showed a bilateral activation pattern following immobilization, but the contralateral activation pattern was restored during the 1-year follow-up visit. Significant differences in the average connection strength over the study period were observed. The average Connection strength decreased from the third week of immobilization and continued to be lower than the baseline value. Global network efficiency decreased in weeks two and three, while the network settled into a higher efficient state during the follow-up periods after post-immobilization. Discussion: Short-term immobilization of the upper limb is shown to have cortical changes in terms of activations of brain regions as well as connectivity. The short-term dis-use of the upper limb has shifted the unilateral activation pattern to the bilateral coactivation of the motor cortex from both hemispheres. Resting-state data reveals a disruption in the motor cortical network during the immobilization phase, and the network is reorganized into an efficient network over 1 year after the injury. Understanding such cortical reorganization could be informative for studying the recovery from neurological disorders affecting motor control in the future.

4.
Front Neurosci ; 17: 1130050, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37234264

RESUMO

Targeted muscle reinnervation (TMR) surgery involves the coaptation of amputated nerves to nearby motor nerve branches with the purpose of reclosing the neuromuscular loop in order to reduce phantom limb pain. The purpose of this case study was to create a phantom limb therapy protocol for an amputee after undergoing TMR surgery, where the four main nerves of his right arm were reinnervated into the chest muscles. The goal of this phantom limb therapy was to further strengthen these newly formed neuromuscular closed loops. The case participant (male, 21- years of age, height = 5'8″ and weight = 134 lbs) presented 1- year after a trans-humeral amputation of the right arm along with TMR surgery and participated in phantom limb therapy for 3 months. Data collections for the subject occurred every 2 weeks for 3 months. During the data collections, the subject performed various movements of the phantom and intact limb specific to each reinnervated nerve and a gross manual dexterity task (Box and Block Test) while measuring brain activity and recording qualitative feedback from the subject. The results demonstrated that phantom limb therapy produced significant changes of cortical activity, reduced fatigue, fluctuation in phantom pain, improved limb synchronization, increased sensory sensation, and decreased correlation strength between intra-hemispheric and inter-hemispheric channels. These results suggest an overall improved cortical efficiency of the sensorimotor network. These results add to the growing knowledge of cortical reorganization after TMR surgery, which is becoming more common to aid in the recovery after amputation. More importantly, the results of this study suggest that the phantom limb therapy may have accelerated the decoupling process, which provides direct clinical benefits to the patient such as reduced fatigue and improved limb synchronization.

5.
Brain Topogr ; 36(2): 210-222, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36757503

RESUMO

Hemispheric dominance has been used to understand the influence of central and peripheral neural damage on the motor function of individuals with stroke, cerebral palsy, and limb loss. It has been well established that greater activation occurs in the contralateral hemisphere to the side of the body used to perform the task. However, there is currently a large variability in calculation procedures for brain laterality when using functional near-infrared spectroscopy (fNIRS) as a non-invasive neuroimaging tool. In this study, we used fNIRS to measure brain activity over the left and right sensorimotor cortices while participants (n = 20, healthy and uninjured) performed left and right-hand movement tasks. Then, we analyzed the fNIRS data using two different processing pipelines (block averaging or general linear model [GLM]), two different criteria of processing for negative values (include all beta values or include only positive beta values), and three different laterality index (LI) formulas. The LI values produced using the block averaging analysis indicated an expected contralateral dominance with some instances of bilateral dominance, which agreed with the expected contralateral activation. However, the inclusion criteria nor the LI formulas altered the outcome. The LI values produced using the GLM analysis displayed a robust left hemisphere dominance regardless of the hand performing the task, which disagreed with the expected contralateral activation but did provide instances of correctly identifying brain laterality. In conclusion, both analysis pipelines were able to correctly determine brain laterality, but processes to account for negative beta values were recommended especially when utilizing the GLM analysis to determine brain laterality.


Assuntos
Córtex Sensório-Motor , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Lateralidade Funcional/fisiologia , Mãos , Extremidade Superior , Mapeamento Encefálico/métodos
6.
Sci Rep ; 12(1): 7447, 2022 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-35523915

RESUMO

Current training interventions assessing pediatric functional motor skills do not account for children and adolescents with upper limb reductions who utilize a prosthesis. Prosthesis rejection showed that 1 out of 5 prosthesis users will reject their prosthesis due to lack of durability, lack of function, not meeting the participant's needs, perceived lack of need, and medical restrictions indicating that prosthetic users believed they were more functional without the device. It was hypothesized that an 8-week Home Intervention program will result in significant improvements in gross manual dexterity, bimanual coordination, and the functional activities performed during the program. It was also hypothesized that the novel Prosthesis Measurement of Independent Function (PMIF) score will reflect the Home Intervention performance improvements. Five pediatric participants (ages 5-19 years) with congenital upper limb reductions were fitted with a 3D printed upper extremity prosthesis for their affected limb. Participants then completed the 8-week Home Intervention which included Training activities completed 2×/week for 8 weeks and Non-Training activities completed only at week 1 and week 8. Participant's times were recorded along with each participant receiving a PMIF score ranging from 0 = unable to complete activity, to 7 = complete independence with activity completion. Results showed a decrease in overall averaged activity times amongst all activities. For all activities performed, individual averaged time decreased with the exception of Ball Play which increased over the 8-week intervention period. There was significant interaction for Home Intervention performance with F = 2.904 (p = 0.003). All participants increased their PMIF scores to 7 (complete independence) at the end of the 8 week intervention period. Decreases in time averages and increases in PMIF scores indicate that learning and functional use of the prostheses have occurred amongst the pediatric participants.


Assuntos
Membros Artificiais , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Destreza Motora , Artéria Radial , Extremidade Superior , Articulação do Punho , Adulto Jovem
7.
Biomed Eng Online ; 21(1): 7, 2022 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35090466

RESUMO

BACKGROUND: The delay between amputation and prosthesis fitting contributes to the high rate of prosthetic abandonment despite advances in technology. Three-dimensional (3D) printing has allowed for the rapid fabrication of prostheses. Allowing individuals with amputations to interact with a prosthesis shortly after their procedure may reduce rejection chances. The purpose of the current investigation is to compare functional outcomes and patient satisfaction between a standard transradial prosthesis fitted in a clinic with a 3D-printed prosthesis fitted remotely. The standard prosthesis featured a hook terminal device, while the 3D printed prosthesis' terminal device was a functional hand. RESULTS: The main finding of this case study was that the use of a 3D printed arm prosthesis fitted remotely resulted in better functional performance, but lower overall patient satisfaction than the standard arm prosthesis. Use of the 3D printed arm resulted in improved gross manual dexterity as measured by the Box and Block test. The 3D printed prosthesis also allowed improved performance in bimanual coordination. However, the standard-hook device scored higher in patient satisfaction survey results. The patient's concerns with the 3D printed prosthesis were the durability and effectiveness of the device. CONCLUSION: While durability and complex grip patterns remain a concern, the positive attributes of 3D printed prostheses include visual appeal, ease of donning, and customization of parameters to improve upper-limb symmetry offers a promising option to familiarize new amputee patients with the use of a prosthesis. Rapid manufacturing and remote fitting allows 3D printed devices to serve as postoperative transitional devices and may function as definitive devices with minimal loss of functionality if standard clinic-based prostheses are not available. METHODS: The patient was a 59-year-old male with a traumatic transradial amputation of the dominant arm. A 3D printed transradial prosthesis was remotely fitted and manufactured using photogrammetry. Assessments were performed initially with the standard-hook prosthesis and then with the 3D printed device after a 5-week familiarization period. Functional outcomes were evaluated using the Box and Block Test and Bimanual Coordination Tray Test. Patient satisfaction was evaluated using two self-reported questionnaires (the QUEST 2.0 and the modified OPUS).


Assuntos
Mãos , Satisfação do Paciente , Humanos , Masculino , Pessoa de Meia-Idade , Desempenho Físico Funcional , Impressão Tridimensional , Desenho de Prótese
8.
Brain Sci ; 11(8)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34439610

RESUMO

This study aimed to examine the neural responses of children using prostheses and prosthetic simulators to better elucidate the emulation abilities of the simulators. We utilized functional near-infrared spectroscopy (fNIRS) to evaluate the neural response in five children with a congenital upper limb reduction (ULR) using a body-powered prosthesis to complete a 60 s gross motor dexterity task. The ULR group was matched with five typically developing children (TD) using their non-preferred hand and a prosthetic simulator on the same hand. The ULR group had lower activation within the primary motor cortex (M1) and supplementary motor area (SMA) compared to the TD group, but nonsignificant differences in the primary somatosensory area (S1). Compared to using their non-preferred hand, the TD group exhibited significantly higher action in S1 when using the simulator, but nonsignificant differences in M1 and SMA. The non-significant differences in S1 activation between groups and the increased activation evoked by the simulator's use may suggest rapid changes in feedback prioritization during tool use. We suggest that prosthetic simulators may elicit increased reliance on proprioceptive and tactile feedback during motor tasks. This knowledge may help to develop future prosthesis rehabilitative training or the improvement of tool-based skills.

9.
Front Neurosci ; 15: 693138, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34177460

RESUMO

The purpose of the current case study was to determine the influence of an 8-week home intervention training utilizing a partial hand prosthesis on hemodynamic responses of the brain and gross dexterity in a case participant with congenital unilateral upper-limb reduction deficiency (ULD). The case participant (female, 19 years of age) performed a gross manual dexterity task (Box and Block Test) while measuring brain activity (functional near-infrared spectroscopy; fNIRS) before and after an 8-weeks home intervention training. During baseline, there was a broad cortical activation in the ipsilateral sensorimotor cortex and a non-focalized cortical activation in the contralateral hemisphere, which was non-focalized, while performing a gross manual dexterity task using a prosthesis. After the 8-week home intervention training, however, cortical activation shifted to the contralateral motor cortex while cortical activation was diminished in the ipsilateral hemisphere. Specifically, the oxygenated hemodynamics (HbO) responses increased in the medial aspects of the contralateral primary motor and somatosensory cortices. Thus, these results suggest that an 8-week prosthetic home intervention was able to strengthen contralateral connections in this young adult with congenital partial hand reduction. This was supported by the case participant showing after training an increased flexor tone, increased range of motion of the wrist, and decreased times to complete various gross dexterity tasks. Changes in HbO responses due to the home intervention training follow the mechanisms of use-dependent plasticity and further guide the use of prostheses as a rehabilitation strategy for individuals with ULD.

10.
J Neuroeng Rehabil ; 18(1): 24, 2021 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-33536034

RESUMO

BACKGROUND: The purpose of the current study was to determine the influence of upper-limb prostheses on brain activity and gross dexterity in children with congenital unilateral upper-limb reduction deficiencies (ULD) compared to typically developing children (TD). METHODS: Five children with ULD (3 boys, 2 girls, 8.76 ± 3.37 years of age) and five age- and sex-matched TD children (3 boys, 2 girls, 8.96 ± 3.23 years of age) performed a gross manual dexterity task (Box and Block Test) while measuring brain activity (functional near-infrared spectroscopy; fNIRS). RESULTS: There were no significant differences (p = 0.948) in gross dexterity performance between the ULD group with prosthesis (7.23 ± 3.37 blocks per minute) and TD group with the prosthetic simulator (7.63 ± 5.61 blocks per minute). However, there was a significant (p = 0.001) difference in Laterality Index (LI) between the ULD group with prosthesis (LI = - 0.2888 ± 0.0205) and TD group with simulator (LI = 0.0504 ± 0.0296) showing in a significant ipsilateral control for the ULD group. Thus, the major finding of the present investigation was that children with ULD, unlike the control group, showed significant activation in the ipsilateral motor cortex on the non-preferred side using a prosthesis during a gross manual dexterity task. CONCLUSIONS: This ipsilateral response may be a compensation strategy in which the existing cortical representations of the non-affected (preferred) side are been used by the affected (non-preferred) side to operate the prosthesis. This study is the first to report altered lateralization in children with ULD while using a prosthesis. Trial registration The clinical trial (ClinicalTrial.gov ID: NCT04110730 and unique protocol ID: IRB # 614-16-FB) was registered on October 1, 2019 ( https://clinicaltrials.gov/ct2/show/NCT04110730 ) and posted on October 1, 2019. The study start date was January 10, 2020. The first participant was enrolled on January 14, 2020, and the trial is scheduled to be completed by August 23, 2023. The trial was updated January 18, 2020 and is currently recruiting.


Assuntos
Membros Artificiais , Lateralidade Funcional/fisiologia , Córtex Motor/fisiologia , Córtex Motor/fisiopatologia , Destreza Motora/fisiologia , Deformidades Congênitas das Extremidades Superiores/fisiopatologia , Criança , Feminino , Humanos , Masculino
11.
Disabil Rehabil Assist Technol ; 16(2): 209-213, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-31385727

RESUMO

INTRODUCTION: Many individuals with stroke still have functional difficulties with their affected hand after going through a rehabilitation program. A 3D printed upper limb exoskeleton was designed for an individual who had a stroke. Functional and neuromuscular outcomes were measured using his affected hand with and without a 3D printed passive exoskeleton. The goal of this study was to determine the functional and neuromuscular changes induced by the 3D printed exoskeleton in a participant with stroke. MATERIALS AND METHODS: The functional ability of the exoskeleton was assessed using the Fugl-Meyer Assessment and the Box and Block Test. Strength testing and muscle activation of the participant's forearms were measured during maximal voluntary contractions. Furthermore, EMG was measured during the Box and Block Test and satisfaction and usability of the 3D printed exoskeleton were assessed using standardized questionnaires. RESULTS: The exoskeleton improved both the participant's Fugl-Meyer Assessment scores and Box and Block test scores compared to not wearing the device. The subject had increased EMG activation in his extensor when wearing the exoskeleton. CONCLUSION: The inexpensive 3D printed exoskeleton was effective in assisting the participant with stroke during the functional assessments and has the potential to be used to help regain function of the hand in the home setting of an individual with stroke.IMPLICATIONS FOR REHABILITATIONA 3D printed passive hand exoskeleton may assist to accomplish rehabilitation outcomes by increasing function of the affected hand of patients with stroke.The use of this hand exoskeleton may be used to improve gross hand dexterity and assist with functional grasps during rehabilitation sessions with a lower patient's level of perceived exertion.The use of new antimicrobial 3D printing polymers can be effectively implemented to manufacture assistive devices to prevent skin infections during rehabilitation.


Assuntos
Desenho Assistido por Computador , Exoesqueleto Energizado , Mãos/fisiopatologia , Impressão Tridimensional , Reabilitação do Acidente Vascular Cerebral/instrumentação , Atividades Cotidianas , Idoso , Humanos , Masculino
12.
Diagn Microbiol Infect Dis ; 98(4): 115176, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33069048

RESUMO

The SARS-CoV-2 is the causative agent of the COVID-19 disease, a severe acute respiratory syndrome-coronavirus (SARS-CoV). Its main transmission pathway is through large respiratory droplets, as well as direct and indirect contact. Copper in different formats has been used in research and clinical settings to reduce the risk of bacterial and viral contamination. Therefore, this review aims to search for evidence about the biocidal properties of copper over the Coronaviridae family. A literature review was performed using PubMed and Ovid servers without date or language restrictions. The search was carried out on March 7, 2020, using the following search terms: [Copper] Coronavirus OR CoV OR SARS OR MERS OR Influenza. Copper destroys the replication and propagation abilities of SARS-CoV, influenza, and other respiratory viruses, having high potential disinfection in hospitals, communities, and households. Copper can eliminate pathogenic organisms such as coronavirus bacterial strains, influenza virus, HIV, and fungi after a short period of exposure. Copper seems to be an effective and low-cost complementary strategy to help reduce the transmission of several infectious diseases by limiting nosocomial infectious transmission. Copper oxide or nanocompounds may be used as filters, face masks, clothing, and hospital common surfaces to reduce viruses and bacterial incubation.


Assuntos
Cobre/farmacologia , Infecções por Coronavirus/prevenção & controle , Desinfetantes/farmacologia , Influenza Humana/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Betacoronavirus/efeitos dos fármacos , COVID-19 , Infecções por Coronavirus/transmissão , Humanos , Influenza Humana/transmissão , Orthomyxoviridae/efeitos dos fármacos , Pneumonia Viral/transmissão , SARS-CoV-2
14.
J Musculoskelet Neuronal Interact ; 20(1): 77-87, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32131371

RESUMO

OBJECTIVES: This study examined the time course of changes and patterns of responses in electromyographic amplitude (EMG AMP) and EMG mean power frequency (MPF) for the superficial quadriceps muscles during exhaustive treadmill runs within the severe exercise intensity zones (SIZ1 and SIZ2). METHODS: The EMG signals for the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) as well as times to exhaustion (Tlim) were recorded in ten runners during two exhaustive treadmill runs (SIZ1 and SIZ2). The composite and individual responses were compared among muscles and between intensities. RESULTS: The composite patterns of responses in EMG AMP (linear, quadratic, and cubic increases; r2/R2=0.684-0.848) and EMG MPF (linear, quadratic, and cubic decreases; r2/R2=0.648 - 0.852) for the VL and RF were consistent with neuromuscular fatigue in both zones, but those for the VM were not (quadratic, cubic, and non-significant relationships with responses near baseline). The RF tended to demonstrate greater fatigue (EMG MPF decreased from 80-100% Tlim). There was large inter-individual variability (only 10-60% of responses consistent with composite) in response to fatiguing treadmill running. CONCLUSIONS: The current findings support the examination and characterization of neuromuscular fatigue on an intensity, muscle, and subject-by-subject basis.


Assuntos
Teste de Esforço/métodos , Fadiga Muscular/fisiologia , Junção Neuromuscular/fisiologia , Músculo Quadríceps/fisiologia , Corrida/fisiologia , Adulto , Eletromiografia/métodos , Feminino , Humanos , Masculino , Adulto Jovem
15.
3D Print Med ; 5(1): 7, 2019 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-31049828

RESUMO

BACKGROUND: Traditional prosthetic fabrication relies heavily on plaster casting and 3D models for the accurate production of prosthetics to allow patients to begin rehabilitation and participate in daily activities. Recent technological advancements allow for the use of 2D photographs to fabricate individualized prosthetics based on patient anthropometrics. Additive manufacturing (i.e. 3D printing) enhances the capability of prosthesis manufacturing by significantly increasing production speed and decreasing production cost. Existing literature has extensively described the validity of using computer-aided design and 3D printing for fabrication of upper limb prostheses. The present investigation provides a detailed description of the development of a patient specific body-powered 3D printed partial finger prosthesis and compares its qualitative and functional characteristics to a commercially available finger prosthesis. CASE PRESENTATION: A 72-year old white male with a partial finger amputation at the proximal interphalangeal joint of the left hand performed a simple gross motor task with two partial finger prostheses and completed two self-reported surveys (QUEST & OPUS). Remote fitting of the 3D printed partial finger began after receipt of 2D photographs of the patient's affected and non-affected limbs. Prosthetic fitting when using 3D printable materials permitted the use of thermoforming around the patient's residual limb, allowing for a comfortable but tight-fitting socket. Results of the investigation show improved performance in the Box and Block Test when using both prostheses (22 blocks per minute) as compared to when not using a prosthesis (18 blocks per minute). Both body-powered prostheses demonstrated slightly lower task-efficiency when compared to the non-affected limb (30 blocks per minute) for the gross motor task. Results of the QUEST and OPUS describe specific aspects of both prostheses that are highly relevant to quality of life and functional performance when using partial finger prostheses. CONCLUSION: The use of 3D printing exhibits great potential for the fabrication of functional partial finger prostheses that improve function in amputees. In addition, 3D printing provides an alternative means for patients located in underdeveloped or low-income areas to procure a functional finger prosthesis.

16.
J Strength Cond Res ; 33(5): 1311-1319, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31033774

RESUMO

Noble, EB, Pilarski, JM, Vora, HK, Zuniga, JM, and Malek, MH. Log-transformed electromyography amplitude-power output relationship: single-leg knee-extensor versus single-leg cycle ergometry. J Strength Cond Res 33(5): 1311-1319, 2019-Comparing and contrasting motor unit recruitment and activation for the same muscles for multiple versus single-joint exercise may provide a better understanding of neuromuscular fatigue. The purpose of this study, therefore, is to compare the slope and y-intercept terms for the 3 superficial quadriceps femoris (QF) (vastus lateralis, rectus femoris, and vastus medialis) muscles derived from the log-transformed electromyography (EMG) amplitude-power output relationship between the single-leg knee-extensor ergometry (KE) and the single-leg cycle ergometry (CE). Ten healthy college-aged men who engaged in regular physical activity visited the laboratory on 2 occasions separated by 7 days to perform either single-leg CE or single-leg KE in a randomized order. For each visit, subjects performed incremental exercise until voluntary fatigue. Electromyography electrodes were placed on the superficial QF muscles. The slope and y-intercept terms, for each muscle, for the EMG amplitude versus power output relationship was examined using the log-transformed model for each subject's data. The results indicated no significant (p > 0.05) mean differences for either slope or y-intercept terms between exercise modes and across muscles. In addition, separate repeated-measures analyses of variance (ANOVAs) were used to determine mean differences for the slope and y-intercept values between the 3 muscles. In addition, separate 2 (mode: CE or KE) × intensity (intensity: 30, 60, and 90% of maximal workload) repeated-measures ANOVAs were conducted for each muscle. There was a significant (p < 0.05) mode × exercise intensity interaction for each muscle. Follow-up testing indicated that in most cases, the normalized EMG amplitude was significantly higher for single-leg KE than single-leg CE. These results indicated that incremental single-leg KE activates the superficial QF muscles significantly greater than single-leg CE.


Assuntos
Exercício Físico/fisiologia , Fadiga/fisiopatologia , Articulação do Joelho/fisiologia , Músculo Quadríceps/fisiologia , Adulto , Fenômenos Biomecânicos , Eletromiografia/métodos , Ergometria/métodos , Teste de Esforço/métodos , Humanos , Masculino , Músculo Esquelético/fisiologia , Adulto Jovem
17.
Expert Rev Med Devices ; 16(3): 257-266, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30661413

RESUMO

BACKGROUND: The objective of the current investigation was twofold: i) describe a remote fitting procedure for upper limb 3D printed prostheses and ii) assess patient satisfaction and comfort with 3D printed prostheses fitted remotely. METHODS: A qualitative study using content and score analysis to describe patient satisfaction after remote prosthetic fitting. Research participants reported QUEST and OPUS scores that allow for perceived rating of general aspects and functionality of upper limb prostheses. RESULTS: Six children (three girls & boys, 6-16 years of age) and 2 adult males (25 and 59 years of age) with congenital (n = 7) and acquired (n = 1) upper limb loss participated in this study. Highest device satisfaction items of the QUEST include weight (4.50 ± 0.76), safety (4.38 ± 0.52), and ease of use (4.13 ± 0.64). Functional tasks of the OPUS observe that prosthesis donning and doffing (1.5 ± 0.84) and drinking from a paper cup (1.75 ± 0.89) were the easiest functional tasks. CONCLUSION: The presented methodology for remote fitting of 3D printed upper-limb prostheses exhibits significant potential for rapid fabrication of functional prostheses to developing countries due to increased availability of digital devices in rural areas.


Assuntos
Membros Artificiais , Impressão Tridimensional , Extremidade Superior/cirurgia , Adolescente , Adulto , Amputados , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aparelhos Ortopédicos , Satisfação do Paciente , Desenho de Prótese , Autorrelato , Inquéritos e Questionários
18.
Disabil Rehabil Assist Technol ; 14(1): 68-74, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29116866

RESUMO

INTRODUCTION: There is limited knowledge on the use of 3 D-printed transitional prostheses, as they relate to changes in function and strength. Therefore, the purpose of this study was to identify functional and strength changes after usage of 3 D-printed transitional prostheses for multiple weeks for children with upper-limb differences. MATERIALS AND METHODS: Gross manual dexterity was assessed using the Box and Block Test and wrist strength was measured using a dynamometer. This testing was conducted before and after a period of 24 ± 2.61 weeks of using a 3 D-printed transitional prosthesis. The 11 children (five girls and six boys; 3-15 years of age) who participated in the study, were fitted with a 3 D-printed transitional partial hand (n = 9) or an arm (n = 2) prosthesis. RESULTS: Separate two-way repeated measures ANOVAs were performed to analyze function and strength data. There was a significant hand by time interaction for function, but not for strength. Conclusion and relevance to the study of disability and rehabilitation: The increase in manual gross dexterity suggests that the Cyborg Beast 2 3 D-printed prosthesis can be used as a transitional device to improve function in children with traumatic or congenital upper-limb differences. Implications for Rehabilitation Children's prosthetic needs are complex due to their small size, rapid growth, and psychosocial development. Advancements in computer-aided design and additive manufacturing offer the possibility of designing and printing transitional prostheses at a very low cost, but there is limited knowledge on the function of this type of devices. The use of 3D printed transitional prostheses may improve manual gross dexterity in children after several weeks of using it.


Assuntos
Membros Artificiais , Crianças com Deficiência/reabilitação , Impressão Tridimensional , Desenho de Prótese , Extremidade Superior , Atividades Cotidianas , Pré-Escolar , Feminino , Humanos , Masculino
19.
J Neuroeng Rehabil ; 15(1): 48, 2018 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-29884185

RESUMO

BACKGROUND: Co-contraction is the simultaneous activation of agonist and antagonist muscles that produces forces around a joint. It is unknown if the use of a wrist-driven 3D printed transitional prostheses has any influence on the neuromuscular motor control strategies of the affected hand of children with unilateral upper-limb reduction deficiencies. Thus, the purpose of the current investigation was to examine the coactivation index (CI) of children with congenital upper-limb reduction deficiencies before and after 6 months of using a wrist-driven 3D printed partial hand prosthesis. METHODS: Electromyographic activity of wrist flexors and extensors (flexor carpi ulnaris and extensor digitorum) was recorded during maximal voluntary contraction of the affected and non-affected wrists. Co-contraction was calculated using the coactivation index and was expressed as percent activation of antagonist over agonist. Nine children (two girls and seven boys, 6 to 16 years of age) with congenital upper-limb deficiencies participated in this study and were fitted with a wrist-driven 3D printed prosthetic hand. From the nine children, five (two girls and three boys, 7 to 10 years of age) completed a second visit after using the wrist-driven 3D printed partial hand prosthesis for 6 months. RESULTS: Separate two-way repeated measures ANOVAs were performed to analyze the coactivation index and strength data. There was a significant main effect for hand with the affected hand resulting in a higher coactivation index for flexion and extension than the non-affected hand. For wrist flexion there was a significant main effect for time indicating that the affected and non-affected hand had a significantly lower coactivation index after a period of 6 months. CONCLUSION: The use of a wrist-driven 3D printed hand prosthesis lowered the coactivation index by 70% in children with congenital upper limb reduction deficiencies. This reduction in coactivation and possible improvement in motor control strategies can potentially improve prosthetic rehabilitation outcomes.


Assuntos
Membros Artificiais , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Impressão Tridimensional , Criança , Feminino , Humanos , Masculino , Extremidade Superior
20.
Expert Rev Med Devices ; 15(5): 349-356, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29723481

RESUMO

INTRODUCTION: 3D-printed anatomical models play an important role in medical and research settings. The recent successes of 3D anatomical models in healthcare have led many institutions to adopt the technology. However, there remain several issues that must be addressed before it can become more wide-spread. Of importance are the problems of cost and time of manufacturing. Machine learning (ML) could be utilized to solve these issues by streamlining the 3D modeling process through rapid medical image segmentation and improved patient selection and image acquisition. The current challenges, potential solutions, and future directions for ML and 3D anatomical modeling in healthcare are discussed. AREAS COVERED: This review covers research articles in the field of machine learning as related to 3D anatomical modeling. Topics discussed include automated image segmentation, cost reduction, and related time constraints. EXPERT COMMENTARY: ML-based segmentation of medical images could potentially improve the process of 3D anatomical modeling. However, until more research is done to validate these technologies in clinical practice, their impact on patient outcomes will remain unknown. We have the necessary computational tools to tackle the problems discussed. The difficulty now lies in our ability to collect sufficient data.


Assuntos
Algoritmos , Aprendizado de Máquina , Impressão Tridimensional , Procedimentos Cirúrgicos Operatórios , Humanos , Modelos Anatômicos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA