1.
Endosc Int Open ; 12(3): E344-E351, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481597

RESUMO

Background and study aims In 2019, the European Society of Gastrointestinal Endoscopy (ESGE) created a working group to develop technical and quality standards for small-bowel capsule endoscopy (SBCE) to improve the daily practice of endoscopy services. They developed 10 quality parameters, which have yet to be tested in a real-life setting. Our study aimed to evaluate the accomplishment of the quality standards in SBCE established by the ESGE in several Spanish centers. Materials and methods An online survey of 11 multiple-choice questions related to the ESGE performance measures was sent to Spanish centers with experience in SBCE. In order to participate and obtain reliable data, at least 100 questionnaires had to be answered per center because that is the minimum number established by ESGE. Results 20 centers participated in the study, compiling 2049 SBCEs for the analysis. Only one of 10 performance measures (cecal visualization) reached the minimum standard established by the ESGE. In five of 10 performance measures (Indication, lesion detection rate, terminology, and retention rate) the minimum standard was nearly achieved. Conclusions Our study is the first multicenter study regarding SBCE quality performance measures in a real setting. Our results show that the minimum standard is hardly reached in most procedures, which calls into question their clinical applicability in real life. We suggest performing similar studies in other countries to evaluate whether there is a need for quality improvement programs or a need to reevaluate the minimum and target values published so far.

2.
Gastrointest Endosc ; 74(3): 581-589.e1, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21601200

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are ≥6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps ≥6 mm and ≥10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps ≥6 mm and ≥10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging.


Assuntos
Adenoma/diagnóstico , Endoscopia por Cápsula , Pólipos do Colo/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Idoso , Endoscopia por Cápsula/efeitos adversos , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA