Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 65(8): 27, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39017633

RESUMO

Purpose: The purpose of this study was to analyze the clinical spectrum and natural history of CDH23-associated Usher syndrome type ID (USH1D). Methods: Molecularly-confirmed individuals had data extracted from medical records. Retinal imaging was extracted from an in-house database. The main outcome measurements were retinal imaging and electroretinography (ERG) and clinical findings, including age of onset, symptoms, best-corrected visual acuity (BCVA), outer nuclear layer (ONL) thickness, ellipsoid zone width (EZW), and hyperautofluorescent ring area. Results: Thirty-one patients were identified, harboring 40 variants in CDH23 (10 being novel). The mean (range, ±SD) age of symptom onset was 10.1 years (range = 1-18, SD = ±4.1). The most common visual symptoms at presentation were nyctalopia (93.5%) and peripheral vision difficulties (61.3%). The mean BCVA at baseline was 0.25 ± 0.22 in the right eyes and 0.35 ± 0.58 LogMAR in the left eyes. The mean annual loss rate in BCVA was 0.018 LogMAR/year over a mean follow-up of 9.5 years. Individuals harboring the c.5237G>A p.(Arg1746Gln) allele had retinitis pigmentosa (RP) sparing the superior retina. Seventy-seven percent of patients had hyperautofluorescent rings in fundus autofluorescence. Full-field and pattern ERGs indicated moderate-severe rod-cone or photoreceptor dysfunction with relative sparing of macular function in most patients tested. Optical coherence tomography (OCT) revealed intraretinal cysts in the transfoveal B-scan of 13 individuals (43.3%). The rate of EZW and ONL thickness loss was mild and suggestive of a wide window of macular preservation. Conclusions: Despite the early onset of symptoms, USH1D has a slowly progressive phenotype. There is high interocular symmetry across all parameters, making it an attractive target for novel therapies.


Assuntos
Caderinas , Eletrorretinografia , Tomografia de Coerência Óptica , Síndromes de Usher , Acuidade Visual , Humanos , Síndromes de Usher/genética , Síndromes de Usher/diagnóstico , Síndromes de Usher/fisiopatologia , Masculino , Feminino , Adolescente , Acuidade Visual/fisiologia , Criança , Tomografia de Coerência Óptica/métodos , Caderinas/genética , Adulto Jovem , Adulto , Pré-Escolar , Retina/diagnóstico por imagem , Retina/patologia , Lactente , Mutação , Pessoa de Meia-Idade , Estudos Retrospectivos , Fenótipo , Angiofluoresceinografia/métodos , Proteínas Relacionadas a Caderinas
2.
Transl Vis Sci Technol ; 13(4): 14, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591946

RESUMO

Purpose: Retinal sensitivity is frequently listed as an end point in clinical trials, often with long working practices. The purpose of this methods study was to provide a new workflow and reduced test time for in-depth characterization of retinal sensitivity. Methods: A workflow for the MP3-S microperimeter with detailed functional characterization of the retina under photopic, mesopic, and scotopic conditions was evaluated. Grids of 32 and 28 test positions for photopic/mesopic and scotopic, respectively, were tested in 12 healthy individuals and compared with an established 68-point grid for test time, mean sensitivity (MS), and bivariate contour ellipse area (BCEA). Results: The mean test time (range; ±SD) was 10.5 minutes (8.4-14.9; ±2.0) in the 68-point grid and 4.3 minutes (3.8-5.0; ±0.4) in the 32-point grid, which was significantly different (P < 0.0001). The mean of difference in test time (±SD; 95% confidence interval) was 6.1 minutes (±2.0; 4.6-7.6). MS and BCEA were significantly correlated between grids (r = 0.89 and 0.74; P = 0.0005 and 0.014, respectively). Mean test time of subjects who underwent the full protocol (n = 4) was 2.15 hours. Conclusions: The protocol suggested herein appears highly feasible with in-depth characterization of retinal function under different testing conditions and in a short test time. Translational Relevance: The protocol described herein allows for characterization of the retina under different testing conditions and in a short test time, which is relevant due to its potential for patient prognostication and follow-up in clinical settings and also given its increasing role as a clinical trial end point.


Assuntos
Retina , Humanos , Retina/fisiologia , Fluxo de Trabalho , Determinação de Ponto Final , Ensaios Clínicos como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA