Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
Chin Med J (Engl) ; 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37606001

RESUMO

BACKGROUND: Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. METHODS: Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University. RESULTS: 3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) (n = 2) or risk of compression coronary artery (n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). CONCLUSIONS: In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.

3.
J Clin Med ; 10(16)2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34441825

RESUMO

Selecting patients with a high chance of endured benefit from transcatheter aortic valve implantation (TAVI) is becoming relevant with changing indications and increasing number of TAVI being performed. The aim of our study was to investigate the association of the multidimensional prognostic index (MPI) based on a comprehensive geriatric assessment (CGA) on survival. The TAVI Care & Cure program is a prospective, observational registry of patients referred for TAVI at the Erasmus MC University Medical Center. Consecutive patients who underwent a complete CGA and TAVI were included. CGA components were used to calculate the MPI score. The impact of the MPI score on survival was evaluated using Cox regression. Furthermore, 376 patients were included, 143 (38.0%) patients belonged to the MPI-1 group and 233 (61.9%) patients to the MPI-2-3 group. After 3 years, 14.9% of the patients in the MPI-1 group and 30.5% of the patients in the MPI-2-3 group died (p = 0.001). Patients in MPI-1 had increased chances of overall survival in comparison with patients in MPI group 2-3 Hazard Ratio (HR) 0.57, (95% Confidence Interval (CI) 0.33-0.98)). In this study we found that the MPI tool could be useful to assess frailty and to predict which patient will have a higher chance of enduring benefit from a TAVI procedure.

5.
J Am Heart Assoc ; : e019236, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33794658

RESUMO

Background Recurrence of mitral regurgitation (MR) after surgical mitral valve repair (SMVR) varies and may require reoperation. Redo mitral valve surgery can be technically challenging and is associated with increased risk of mortality and morbidity. We aimed to assess the feasibility and safety of MitraClip as a treatment strategy after failed SMVR and identify procedure modifications to overcome technical challenges. Methods and Results This international multicenter observational retrospective study collected information for all patients from 16 high-volume hospitals who were treated with MitraClip after failed SMVR from October 29, 2009, until August 1, 2017. Data were anonymously collected. Technical and device success were recorded per modified Mitral Valve Academic Research Consortium criteria. Overall, 104 consecutive patients were included. Median Society of Thoracic Surgeons score was 4.5% and median age was 73 years. At baseline, the majority of patients (82%) were in New York Heart Association class ≥III and MR was moderate or higher in 86% of patients. The cause of MR pre-SMVR was degenerative in 50%, functional in 35%, mixed in 8%, and missing/unknown in 8% of patients. The median time between SMVR and MitraClip was 5.3 (1.9-9.7) years. Technical and device success were 90% and 89%, respectively. Additional/modified imaging was applied in 21% of cases. An MR reduction of ≥1 grade was achieved in 94% of patients and residual MR was moderate or less in 90% of patients. In-hospital all-cause mortality was 2%, and 86% of patients were in New York Heart Association class ≤II. Conclusions MitraClip is a safe and less invasive treatment option for patients with recurrent MR after failed SMVR. Additional/modified imaging may help overcome technical challenges during leaflet grasping.

6.
Eur Heart J Case Rep ; 5(1): ytaa573, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33521516

RESUMO

BACKGROUND: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) occurs in up to 1.5% of patients within the first year. The development of an aorto-atrial fistula (AAF) is a rare but problematic complication of IE, which can be confirmed with transoesophageal echocardiography (TOE). We present an exceptional case of occluding an aorto-left atrial fistula only diagnosed with intraprocedural TOE during a subsequent procedure of MitraClip implantation. CASE SUMMARY: A 79-year-old symptomatic male patient with multiple comorbidities was referred due to severe mitral regurgitation (MR). He has had prior TAVI which was complicated with streptococcal IE for which he had received prolonged antibacterial therapy. Transthoracic echocardiography (TTE) revealed severe MR. The patient was accepted for a MitraClip procedure by the heart team. Intra-procedural TOE revealed also a significant continuous shunt through an AAF which was likely caused by the endocarditis. The strategy was therefore defined as to occlude the fistula with an Amplatzer Vascular Plug II 12 mm. The plug was released in the fistula leaving an insignificant residual shunt. After the transseptal puncture one MitraClip XTR was implanted, reducing the MR to mild. After the procedure, the patient's general clinical condition improved without signs of haemolysis. The pre-discharge TTE confirmed trace residual shunt, mild residual MR and mild paravalvular leakage. DISCUSSION: Our case illustrates a complex transcatheter structural heart intervention with improvised procedural strategies based on the intra-procedural TOE findings. We conclude that the pre-procedural TOE needs to be comprehensive rather than exclusive, particularly in the context of bioprosthesis-related endocarditis.

7.
Acta Cardiol ; 76(2): 185-193, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31920151

RESUMO

BACKGROUND: Elevated pulmonary artery pressure (PAP) in patients with severe aortic stenosis (AS) is a strong predictor of adverse prognosis. This study sought to assess the relation between PAP and clinical and echocardiographic parameters in elderly patients with severe AS, as well as to identify the determinants of the change in PAP after transcatheter aortic valve implantation (TAVI). METHODS: The study included 170 subjects (age 81 ± 7 years, 45% men) with symptomatic severe AS who were treated by TAVI. They underwent a clinical evaluation and a transthoracic echocardiography before the TAVI procedure and 6 months after. RESULTS: In a multivariable analysis, the independent predictors for baseline PAP were the body mass index (BMI) (ß = 0.21, p = .006), COPD GOLD class (ß = 0.20; p = .009), the E/e' ratio (ß = 0.20; p = .02) and the degree of aortic regurgitation (ß = 0.20; p = .01). After TAVI, there was significantly less (51% vs. 29%, p<.0001) pulmonary hypertension, defined as a tricuspid regurgitation velocity ≥2.8 m/s. The baseline variables related to an improvement in PAP were the tricuspid regurgitation velocity (p = .0001) and the E/e' (p = .005). From the parameters potentially modified with TAVI, the only independent predictor of PAP variation was the change in the E/e' ratio (ß = 0.23; p = .01). CONCLUSIONS: Independent predictors for baseline PAP in elderly patients with symptomatic AS were the BMI, GOLD class, the aortic regurgitation and the E/e' ratio. The baseline predictors for a change in PAP 6 months after TAVI were the baseline PAP and E/e', with only the change in the E/e' ratio being correlated to the change in PAP.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Pressão Arterial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem
9.
Catheter Cardiovasc Interv ; 98(4): 671-677, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33022098

RESUMO

OBJECTIVES: To validate novel dedicated 3D-QCA based on the software to calculate post PCI vessel-FFR (vFFR) in a consecutive series of patients, to assess the diagnostic accuracy, and to assess inter-observer variability. BACKGROUND: Low post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) predicts future adverse cardiac events. However, FFR assessment requires the insertion of a pressure wire in combination with the use of a hyperemic agent. METHODS: FAST POST study is an observational, retrospective, single-center cohort study. One hundred patients presenting with stable angina or non ST-elevation myocardial infarction, who underwent post PCI FFR assessment using a dedicated microcatheter were included. Two orthogonal angiographic projections were acquired to create a 3D reconstruction of the coronary artery using the CAAS workstation 8.0. vFFR was subsequently calculated using the aortic root pressure. RESULTS: Mean age was 65±12 years and 70% were male. Mean microcatheter based FFR and vFFR were 0.91±0.07 and 0.91±0.06, respectively. A good linear correlation was found between FFR and vFFR (r = 0.88; p <.001). vFFR had a higher accuracy in the identification of patients with FFR values <0.90, AUC 0.98 (95% CI: 0.96-1.00) as compared with 3D-QCA AUC 0.62 (95% CI: 0.94-0.74). Assessment of vFFR had a low inter-observer variability (r = 0.95; p <.001). CONCLUSION: 3D-QCA derived post PCI vFFR correlates well with invasively measured microcatheter based FFR and has a high diagnostic accuracy to detect FFR <0.90 with low inter-observer variability.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Estudos de Coortes , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Retrospectivos , Software , Resultado do Tratamento
12.
Int J Cardiol ; 317: 33-36, 2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32433997

RESUMO

BACKGROUND: Patients with a low post PCI fractional flow reserve (FFR) are at increased risk for future adverse cardiac events. The aim of the present study was to assess the impact of specific intravascular ultrasound (IVUS) findings in patients with a low post percutaneous coronary intervention (PCI) FFR on long-term clinical outcome. METHODS: In a subgroup analysis, 100 vessels with an FFR value ≤0.85 underwent post PCI IVUS to further assess the potential determinants for low post PCI FFR. No further action was taken to improve post PCI FFR. The primary endpoint of this study was the event free survival of target vessel failure (TVF) at two years in patients with a post PCI FFR ≤0.85, which was defined as a composite of cardiac death, target vessel myocardial infarction or target vessel revascularization. RESULTS: In patients with a post PCI FFR ≤0.85, TVF free survival rates were 88.5% vs. 95.5% for patients with versus without residual proximal lesions and 88.2% vs. 95.5% for patients with versus without residual distal lesions respectively (HR = 2.53, 95% confidence interval (CI) 0.52-12.25, p = .25 and HR = 2.60, 95% CI 0.54-12.59, p = .24 respectively). TVF free survival was 92.8% vs. 93.5% in patients with versus without stent underexpansion >20% (HR = 1.01, 95% CI 0.21-4.88, p = .99) and 89.3% vs. 97.8% in patients with versus without any residual focal lesion including lumen compromising hematoma (HR = 4.64, 95% CI 0.55-39.22, p = .18). CONCLUSION: Numerically higher TVF rates were observed in patients with a post PCI FFR ≤0.85 and clear focal residual disease as assessed with IVUS.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
13.
Age Ageing ; 49(6): 989-994, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32421189

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI. METHODS: The TAVI Care & Cure Program is an ongoing, prospective, observational study including patients referred for TAVI to our institution. A comprehensive geriatric assessment was performed to evaluate existence of frailty using the Erasmus Frailty Score (EFS). HRQoL was assessed using the EQ-5D-5 L at baseline and 1 year after TAVI. RESULTS: 239 patients underwent TAVI and completed HRQoL assessment 1 year after TAVI. Seventy (29.3%) patients were classified as frail (EFS ≥ 3). In non-frail patients, the EQ-5D-5 L index did not change (0.71(± 0.22) to 0.68(± 0.33) points, P = 0.22); in frail patients, the EQ-5D-5 L index decreased from 0.55(±0.26) to 0.44 points (±0.33) (P = 0.022). Frailty was an independent predictor of deteriorated HRQoL 1 year after TAVI (OR 2.24, 95% CI 1.07-4.70, P = 0.003). In frail patients, the absence of peripheral artery disease (OR 0.17, 95% 0.05-0.50, P = 0.001) and renal dysfunction (OR 0.13, 95% CI 0.04-0.41, P = <0.001) at baseline was associated with improved HRQoL 1 year after TAVI. CONCLUSION: Frailty is associated with deterioration of HRQoL 1 year after TAVI. Notably, HRQoL did improve in frail patients with no peripheral arterial disease or renal impairment at baseline.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Idoso Fragilizado , Fragilidade/diagnóstico , Humanos , Estudos Prospectivos , Qualidade de Vida , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Age Ageing ; 49(3): 389-394, 2020 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-32091096

RESUMO

BACKGROUND: delirium is an event leading to negative health outcomes and increased mortality in patients. The aim of this study is to investigate the incidence, determinants and consequences of post-operative delirium (POD) in older patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: The TAVI Care and Cure program is a prospective, observational registry in patients referred for TAVI at Erasmus University Medical Centre. The presence of delirium was evaluated by daily clinical assessment by a geriatrician pre- and up to 3 days post-TAVI. Mortality data were obtained from the Dutch Civil Registry. RESULTS: A total of 543 patients underwent TAVI between January 2014 and December 2017. Overall, the incidence of POD was 14% (75/543 patients) but declined from 18% in 2014 to 7% in 2017 (P = 0.009). Patients who developed POD were older (81.9 ± 5.8 versus 78.6 ± 8.3 years, P < 0.001), had higher prevalence of renal dysfunction and prior stroke (54% versus 40%, P = 0.02; 31% versus 18%, P = 0.01) and were more often frail (32% versus 25%, P = 0.02). From a procedural perspective, general anesthesia (odds ratios (OR), 2.31; 95% CI, 1.40-3.83; P = 0.001), non-transfemoral access (OR, 2.37; 95% CI, 1.20-4.70; P = 0.01) and longer procedural time (OR, 1.01; 95% CI, 1.01-1.02; P < 0.001) were significantly associated with POD. One-year survival rate was 68% among patients who had suffered a POD and was 85% in patients without a POD (hazard ratio's 1.8 (95% CI 1.01-3.10), P = 0.045). CONCLUSION: POD frequently occurs after TAVI and is associated with increased mortality. It might be speculated that patient selection and the minimalistic approach of TAVI may reduce the frequency of delirium.


Assuntos
Estenose da Valva Aórtica , Delírio , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Delírio/diagnóstico , Delírio/epidemiologia , Humanos , Incidência , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Circ Cardiovasc Interv ; 13(1): e008372, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31937136

RESUMO

BACKGROUND: In aortic stenosis, valvulo-arterial impedance (Zva) estimates the overall left ventricular afterload (valve and arterial component). We investigated the association of Zva (≥5 versus <5 mm Hg mL-1 m-2) on quality of life (QOL) and exercise performance (EP) ≥1 year after transcatheter aortic valve replacement (TAVR). METHODS: The study population consists of 250 TAVR patients in whom baseline Zva and follow-up QOL was prospectively assessed using EuroQOL-5-dimensions instruments; EP was assessed in 192 patients who survived ≥1 year after TAVR using questionnaires related to daily activities. In 124 patients, Zva at 1-year was also available and was used to study the change in Zva (baseline to 1 year) on QOL/EP. RESULTS: Elevated baseline Zva was present in 125 patients (50%). At a median of 28 (IQR, 17-40) months, patients with elevated baseline Zva were more limited in mobility (88% versus 71%; P=0.004), self-care (40% versus 25%; P=0.019), and independent daily activities (taking a shower: 53% versus 38%, P=0.030; walking 100 meter: 76% versus 54%, P=0.001; and walking stairs: 74% versus 54%, P=0.011). By multivariable analysis, elevated Zva predicted unfavorable QOL (lower EuroQOL-5-dimensions-Utility Index, odds ratio, 1.98; CI, 1.15-3.41) and unfavorable EP (any limitation in ≥3 daily activities, odds ratio, 2.55; CI, 1.41-4.62). After TAVR, the proportion of patients with elevated Zva fell from 50% to 21% and remained 21% at 1 year and was found to be associated with more limitations in mobility, self-care, and daily activities compared with patients with Zva <5 mm Hg mL-1 m-2. CONCLUSIONS: Elevated Zva was seen in half of patients and predicted unfavorable long-term QOL and EP. At 1 year after TAVR, the prevalence of elevated Zva was 21% but remained associated with poor QOL/EP.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Tolerância ao Exercício , Hemodinâmica , Qualidade de Vida , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Inquéritos e Questionários , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 95(6): 1085-1091, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31301161

RESUMO

OBJECTIVE AND BACKGROUND: The study aim is to provide long-term clinical outcome after percutaneous coronary intervention (PCI) for unprotected left main coronary arteries (ULMCA) stenosis with the first-generation (1st -gen) drug-eluting stents (DES) in comparison to 2nd -gen DES, since this is largely unknown. METHODS: Between May 2002, and December 2014, a consecutive series of 656 all-comer patients underwent a PCI for ULMCA stenosis at the Erasmus Medical Center. A total of 235 patients were treated with 1st -gen DES, while a total of 421 patients were treated with 2nd -gen DES. RESULTS: Overall, the population consisted of 73% males and 58% presented with an acute coronary syndrome. Median follow-up time was 1,361 days (range from 0 to 5,031). At 5 years, the cumulative incidence of major adverse clinical events (the primary composite endpoint of all-cause death, any myocardial infarction or target lesion revascularization; MACE) did not differ between 1st - and 2nd -gen DES (36.8 vs. 38.6%, respectively, Log Rank p = .79, adjusted hazard ratio [HR] = 1.28 [95% confidence interval (CI) 0.94-1.74]). No difference was found in the individual endpoints of all-cause mortality (29.5 vs. 29% respectively, p = .88, adjusted HR = 1.19 [95% CI, 0.84-1.68]), target vessel myocardial infarction (5.0 vs. 8.4%, p = 0.17, adjusted HR = 1.75 [95% CI, 0.78-3.96]) and target lesion revascularization (8.1 vs. 9.8%, p = .94, adjusted HR = 1.16 [95% CI, 0.59-2.29]) between the 1st - and 2nd -gen DES cohorts, respectively. CONCLUSIONS: In this large cohort of consecutive patients treated for ULMCA stenosis, no significant differences were found in the safety and efficacy of 1st versus 2nd -gen DES at 5 years follow-up.


Assuntos
Síndrome Coronariana Aguda/terapia , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Int J Cardiol ; 302: 36-41, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31859111

RESUMO

BACKGROUND: The capacity of TAVI-programs and numbers of sites performing TAVI has rapidly increased. This necessitated the initiation of the Rotterdam TAVI Care & Cure Program, aiming to improve patient-centered care during the TAVI pathway. METHODS: Consenting patients with severe aortic stenosis and an indication for TAVI will be included. The TAVI Care & Cure program will facilitate prognostic contributions to improve outcomes, patient satisfaction and quality of life in patients with valvular heart disease who are treated with a transcatheter aortic valve implantation in collaboration with the departments of cardiology, cardio-thoracic surgery, anesthesiology and geriatrics. CONCLUSION: With a single center observational registry, we aim to assess the TAVI patient clinical pathway, focusing on pre, peri and post interventional variables including functional status and HRQoL. We will evaluate the patient's complexity by applying an extended multidisciplinary approach, which includes a systematic application of geriatric assessments of frailty and cognitive function.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fragilidade/complicações , Avaliação Geriátrica , Qualidade de Vida , Sistema de Registros , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Feminino , Fragilidade/psicologia , Humanos , Masculino , Países Baixos , Resultado do Tratamento
18.
Int J Cardiovasc Imaging ; 36(1): 123-129, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31515695

RESUMO

Valve size selection for transcatheter aortic valve replacement (TAVR) is currently based on cardiac CT-scan. At variance with patient-specific computer simulation, this does not allow the assessment of the valve-host interaction. We aimed to compare clinical valve size selection and valve size selection by an independent expert for computer simulation. A multicenter retrospective analysis of valve size selection by the physician and the independent expert in 141 patients who underwent TAVR with the self-expanding CoreValve or Evolut R. Baseline CT-scan was used for clinical valve size selection and for patient-specific computer simulation. Simulation results were not available for clinical use. Overall true concordance between clinical and simulated valve size selection was observed in 47 patients (33%), true discordance in 15 (11%) and ambiguity in 79 (56%). In 62 (44%, cohort A) one valve size was simulated whereas two valve sizes were simulated in 79 (56%, cohort B). In cohort A, concordance was 76% and discordance was 24%; a smaller valve size was selected for simulation in 10 patients and a larger in 5. In cohort B, a different valve size was selected for simulation in all patients in addition to the valve size that was used for TAVR. The different valve size concerned a smaller valve in 45 patients (57%) and a larger in 34 (43%). Selection of the valve size differs between the physician and the independent computer simulation expert who used the same source of information. These findings indicate that valve sizing in TAVR is still more intricate than generally assumed.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Modelagem Computacional Específica para o Paciente , Cirurgiões/psicologia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Competência Clínica , Tomada de Decisão Clínica , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Masculino , Modelos Cardiovasculares , Variações Dependentes do Observador , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
Catheter Cardiovasc Interv ; 96(3): E204-E212, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31789481

RESUMO

OBJECTIVES: The aim of this study was to evaluate the very long-term clinical outcome after radioactive stent (RS) implantation and intracoronary ß radiation brachytherapy (IRBT). BACKGROUND: Radioactive stents (RS) and intracoronary ß radiation brachytherapy (IRBT) were introduced to prevent restenosis after percutaneous coronary intervention (PCI). Both techniques were associated with a higher incidence of major adverse cardiac events (MACE) in the short and intermediate-term follow up as compared to conventional PCI. METHODS: One hundred and thirty-three patients received radioactive stents (32 P) and 301 patients were treated with IRBT adjunctive to PCI. These groups were propensity matched to respectively 266 and 602 control patients who were treated with routine PCI during the same inclusion period. Endpoints were all-cause mortality and MACE, defined as all-cause death, any myocardial infarction or any revascularization. RESULTS: Median follow-up duration was 17 years. All-cause mortality rates were similar in all groups. Adjusted hazard ratios for MACE and mortality in the RS cohort were 1.55 (95% CI 1.20-2.00) and 0.92 (95% CI 0.63-1.34), respectively. Adjusted hazard ratios for MACE and all-cause mortality in the IRBT cohort were 1.41 (95% CI 1.18-1.67) and 0.95 (95% CI 0.74-1.21), respectively. The difference in MACE rates was predominantly driven by coronary revascularizations in both groups, with a higher MI rate in the IRBT group as well. CONCLUSIONS: Coronary radiation therapy was associated with early increased MACE rates, but the difference in MACE rates decreased beyond 2 years, resulting in a comparable long-term clinical outcome. Importantly, no excess in mortality was observed.


Assuntos
Braquiterapia , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Braquiterapia/efeitos adversos , Braquiterapia/mortalidade , Estudos de Casos e Controles , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Países Baixos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Am Heart J ; 213: 66-72, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31128504

RESUMO

BACKGROUND: Post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) is a significant predictor of major adverse cardiac events (MACE). The rationale for low post procedural FFR values often remains elusive based on angiographic findings alone, warranting further assessment using an FFR pullback or additional intravascular imaging. It is currently unknown if additional interventions intended to improve the PCI, decrease MACE rates. STUDY DESIGN: The FFR REACT trial is a prospective, single-center randomized controlled trial in which 290 patients with a post PCI FFR <0.90 will be randomized (1:1) to either standard of care (no additional intervention) or intravascular ultrasound (IVUS)-directed optimization of the FFR (treatment arm). Eligible patients are those treated with angiographically successful PCI for (un)stable angina or non-ST elevation myocardial infarction (MI). Assuming 45% of patients will have a post PCI FFR <0.90, approximately 640 patients undergoing PCI will need to be enrolled. Patients with a post PCI FFR ≥ 0.90 will be enrolled in a prospective registry. The primary end point is defined as a composite of cardiac death, target vessel MI and clinically driven target vessel revascularisation (target vessel failure) at 1 year. Secondary end points will consist of individual components of the primary end point, procedural success, stent thrombosis and correlations on clinical outcome, changes in post PCI Pd/Pa and FFR and IVUS derived dimensions. All patients will be followed for 3 years. CONCLUSION: The FFR-REACT trial is designed to explore the potential benefit of HD-IVUS-guided PCI optimization in patients with a post PCI FFR <0.90 (Dutch trial register: NTR6711).


Assuntos
Angina Estável/terapia , Endossonografia/métodos , Reserva Fracionada de Fluxo Miocárdico , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Angina Estável/fisiopatologia , Humanos , Revascularização Miocárdica , Infarto do Miocárdio sem Supradesnível do Segmento ST/fisiopatologia , Estudos Prospectivos , Padrão de Cuidado
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA