Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Radiol ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967787

RESUMO

The need for urgent or emergent cardiovascular imaging in children is rare when compared to adults. Patients may present from the neonatal period up to adolescence, and may require imaging for both traumatic and non-traumatic causes. In children, coronary pathology is rarely the cause of an emergency unlike in adults where it is the main cause. Radiology, including chest radiography and computed tomography in conjunction with echocardiography, often plays the most important role in the acute management of these patients. Magnetic resonance imaging can occasionally be useful and may be suitable in more subacute cases. Radiologists' knowledge of how to manage and interpret these acute conditions including knowing which imaging technique to use is fundamental to appropriate care. In this review, we will concentrate on the most common cardiovascular emergencies in the thoracic region, including thoracic traumatic and non-traumatic emergencies and pulmonary vascular emergencies, as well as acute clinical disorders as a consequence of primary and postoperative congenital heart disease. This review will cover situations where cardiovascular imaging may be acutely needed, and not strictly emergencies only. Imaging recommendations will be discussed according to the different clinical presentations and underlying pathology.

2.
Front Pediatr ; 12: 1339679, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818350

RESUMO

Background: In children with congenital heart disease (CHD), lung scintigraphy is the reference standard for evaluation of pulmonary perfusion. 4D flow CMR offers a non-ionizing alternative. Due to the intrinsic limitation in the spatial resolution, however, 4D flow may display clinically unacceptable differences compared to the reference standard. This case study aims to highlight the importance of correcting for such partial volume errors to accurately evaluate pulmonary perfusion in small pulmonary arteries. Methods: Children with CHD, mainly those with transposition of the great arteries or tetralogy-of-Fallot, referred to CMR from 2020 to 2022 at our clinic, were retrospectively reviewed; n = 37. All patients had been examined with a free breathing, motion-corrected 4D flow protocol. Comparison in pulmonary perfusion (PPR: relative flow through right and left pulmonary arteries) with scintigraphy were performed both for 4D flow before and after partial volume correction. Results: Patients with large pulmonary arteries, 76%, displayed small differences in PPR between modalities (<20%), while patients with arteries of only a few pixels, 24%, displayed differences up to 178%, depending on the relative difference in size between the right and left pulmonary artery. Differences were effectively reduced after partial volume correction (<21%). Conclusion: The present report shows that 4D flow is a promising tool to accurately evaluate the pulmonary perfusion in children with CHD, but that partial volume correction is warranted to overcome its limitation in the spatial resolution. Without such correction, lung scintigraphy is still recommended to ensure high diagnostic certainty in children with small pulmonary arteries.

3.
Sci Rep ; 14(1): 6941, 2024 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521832

RESUMO

Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. An invitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% during full-assist mode. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Coração Univentricular , Humanos , Hemodinâmica , Artéria Pulmonar , Ventrículos do Coração , Cardiopatias Congênitas/cirurgia , Modelos Cardiovasculares
4.
Sci Rep ; 14(1): 6581, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503845

RESUMO

The potential association between endurance exercise and myocardial fibrosis is controversial. Data on exercise exposure and diffuse myocardial fibrosis in endurance athletes are scarce and conflicting. We aimed to investigate the association between exercise exposure and markers of diffuse myocardial fibrosis by cardiovascular magnetic resonance imaging (CMR) in endurance athletes. We examined 27 healthy adult male competitive endurance athletes aged 41 ± 9 years and 16 healthy controls in a cross sectional study using 3 Tesla CMR including late gadolinium enhancement and T1 mapping. Athletes reported detailed exercise history from 12 years of age. Left ventricular total mass, cellular mass and extracellular mass were higher in athletes than controls (86 vs. 58 g/m2, 67 vs. 44 g/m2 and 19 vs. 13 g/m2, all p < 0.01). Extracellular volume (ECV) was lower (21.5% vs. 23.8%, p = 0.03) and native T1 time was shorter (1214 ms vs. 1268 ms, p < 0.01) in the athletes. Increasing exercise dose was independently associated with shorter native T1 time (regression coefficient - 24.1, p < 0.05), but expressed no association with ECV. Our results indicate that diffuse myocardial fibrosis has a low prevalence in healthy male endurance athletes and do not indicate an adverse dose-response relationship between exercise and diffuse myocardial fibrosis in healthy athletes.


Assuntos
Cardiomiopatias , Meios de Contraste , Adulto , Humanos , Masculino , Criança , Estudos Transversais , Gadolínio , Miocárdio/patologia , Cardiomiopatias/patologia , Fibrose , Atletas , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Função Ventricular Esquerda , Volume Sistólico
5.
Pediatr Radiol ; 54(2): 269-275, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38216682

RESUMO

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of intraoperative and postoperative complications. So far, only limited data regarding the best radiological approach to monitor children during liver transplantation is available. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra- and postoperative phase. This paper reports the responses related to intraoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: Intraoperative ultrasound (US) is used by all sites to assess the quality of the vascular anastomosis in order to ensure optimal perfusion of the liver transplant. Vessel depiction is commonly achieved using color Doppler (95.3%). Additional US-based techniques are employed by fewer centers (power angio mode, 28.6%; B-flow, 19%; contrast-enhanced US, 14.3%). Most centers prefer a collaborative approach, with surgeons responsible for probe handling, while radiologists operate the US machine (47.6%). Less commonly, the intraoperative US is performed by the surgeon alone (28.6%) or by the radiologist alone (23.8%). Timing of US, imaging frequency, and documentation practices vary among centers. CONCLUSION: Intraoperative US is consistently utilized across all sites during pediatric liver transplantation. However, considerable variations were observed in terms of the US setup, technique preferences, timing of controls, and documentation practices. These differences provide valuable insights for future optimization and harmonization studies.


Assuntos
Transplante de Fígado , Radiologia , Criança , Humanos , Ultrassonografia , Radiografia , Complicações Pós-Operatórias/diagnóstico por imagem
6.
Pediatr Radiol ; 54(2): 276-284, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38285190

RESUMO

BACKGROUND: Liver transplantation is the state-of-the-art curative treatment for end-stage liver disease. Imaging is a key element in the detection of postoperative complications. So far, limited data is available regarding the best radiologic approach to monitor children after liver transplantation. OBJECTIVE: To harmonize the imaging of pediatric liver transplantation, the European Society of Pediatric Radiology Abdominal Taskforce initiated a survey addressing the current status of imaging including the pre-, intra-, and postoperative phases. This paper reports the responses related to postoperative imaging. MATERIALS AND METHODS: An online survey, initiated in 2021, asked European centers performing pediatric liver transplantation 48 questions about their imaging approach. In total, 26 centers were contacted, and 22 institutions from 11 countries returned the survey. RESULTS: All sites commence ultrasound (US) monitoring within 24 h after liver transplantation. Monitoring frequency varies across sites, ranging from every 8 h to 72 h in early, and from daily to sporadic use in late postoperative phases. Predefined US protocols are used by 73% of sites. This commonly includes gray scale, color Doppler, and quantitative flow assessment. Alternative flow imaging techniques, contrast-enhanced US, and elastography are applied at 31.8%, 18.2%, and 63.6% of sites, respectively. Computed tomography is performed at 86.4% of sites when clarification is needed. Magnetic resonance imaging is used for selected cases at 36.4% of sites, mainly for assessment of biliary abnormalities or when blood tests are abnormal. CONCLUSION: Diagnostic imaging is extensively used for postoperative surveillance of children after liver transplantation. While US is generally prioritized, substantial differences were noted in US protocol, timing, and monitoring frequency. The study highlights potential areas for future optimization and standardization of imaging, essential for conducting multicenter studies.


Assuntos
Transplante de Fígado , Radiologia , Criança , Humanos , Ultrassonografia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Doppler , Complicações Pós-Operatórias/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA