Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(12)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36553021

RESUMO

Good collateral status in acute ischemic stroke patients is an important indicator for good outcomes. Perfusion imaging potentially allows for the simultaneous assessment of local perfusion and collateral status. We combined multiple CTP parameters to evaluate a CTP-based collateral score. We included 85 patients with a baseline CTP and single-phase CTA images from the MR CLEAN Registry. We evaluated patients' CTP parameters, including relative CBVs and tissue volumes with several time-to-maximum ranges, to be candidates for a CTP-based collateral score. The score candidate with the strongest association with CTA-based collateral score and a 90-day mRS was included for further analyses. We assessed the association of the CTP-based collateral score with the functional outcome (mRS 0-2) by analyzing three regression models: baseline prognostic factors (model 1), model 1 including the CTA-based collateral score (model 2), and model 1 including the CTP-based collateral score (model 3). The model performance was evaluated using C-statistic. Among the CTP-based collateral score candidates, relative CBVs with a time-to-maximum of 6-10 s showed a significant association with CTA-based collateral scores (p = 0.02) and mRS (p = 0.05) and was therefore selected for further analysis. Model 3 most accurately predicted favorable outcomes (C-statistic = 0.86, 95% CI: 0.77-0.94) although differences between regression models were not statistically significant. We introduced a CTP-based collateral score, which is significantly associated with functional outcome and may serve as an alternative collateral measure in settings where MR imaging is not feasible.

2.
Life (Basel) ; 12(2)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35207536

RESUMO

This study tests fluorescence imaging-derived quantitative parameters for perfusion evaluation of the gastric tube during surgery and correlates these parameters with patient outcomes in terms of anastomotic leakage. Poor fundus perfusion is seen as a major factor for the development of anastomotic leakage and strictures. Fluorescence perfusion imaging may reduce the incidence of complications. Parameters for the quantification of the fluorescence signal are still lacking. Quantitative parameters in terms of maximal intensity, mean slope and influx timepoint were tested for significant differences between four perfusion areas of the gastric tube in 22 patients with a repeated ANOVA test. These parameters were compared with patient outcomes. Maximal intensity, mean slope and influx timepoint were significantly different between the base of the gastric tube and the fundus (p < 0.0001). Patients who developed anastomotic leakage showed a mean slope of almost 0 in Location 4. The distance of the demarcation of ICG to the fundus was significantly higher in the three patients who developed anastomotic leakage (p < 0.0001). This study presents quantitative intra-operative perfusion imaging with fluorescence. Quantification of the fluorescence signal allows for early risk stratification of necrosis.

3.
J Magn Reson Imaging ; 55(6): 1785-1794, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34792263

RESUMO

BACKGROUND: Damping of heartbeat-induced pressure pulsations occurs in large arteries such as the aorta and extends to the small arteries and microcirculation. Since recently, 7 T MRI enables investigation of damping in the small cerebral arteries. PURPOSE: To investigate flow pulsatility damping between the first segment of the middle cerebral artery (M1) and the small perforating arteries using magnetic resonance imaging. STUDY TYPE: Retrospective. SUBJECTS: Thirty-eight participants (45% female) aged above 50 without history of heart failure, carotid occlusive disease, or cognitive impairment. FIELD STRENGTH/SEQUENCE: 3 T gradient echo (GE) T1-weighted images, spin-echo fluid-attenuated inversion recovery images, GE two-dimensional (2D) phase-contrast, and GE cine steady-state free precession images were acquired. At 7 T, T1-weighted images, GE quantitative-flow, and GE 2D phase-contrast images were acquired. ASSESSMENT: Velocity pulsatilities of the M1 and perforating arteries in the basal ganglia (BG) and semi-oval center (CSO) were measured. We used the damping index between the M1 and perforating arteries as a damping indicator (velocity pulsatilityM1 /velocity pulsatilityCSO/BG ). Left ventricular stroke volume (LVSV), mean arterial pressure (MAP), pulse pressure (PP), and aortic pulse wave velocity (PWV) were correlated with velocity pulsatility in the M1 and in perforating arteries, and with the damping index of the CSO and BG. STATISTICAL TESTS: Correlations of LVSV, MAP, PP, and PWV with velocity pulsatility in the M1 and small perforating arteries, and correlations with the damping indices were evaluated with linear regression analyses. RESULTS: PP and PWV were significantly positively correlated to M1 velocity pulsatility. PWV was significantly negatively correlated to CSO velocity pulsatility, and PP was unrelated to CSO velocity pulsatility (P = 0.28). PP and PWV were uncorrelated to BG velocity pulsatility (P = 0.25; P = 0.68). PWV and PP were significantly positively correlated with the CSO damping index. DATA CONCLUSION: Our study demonstrated a dynamic damping of velocity pulsatility between the M1 and small cerebral perforating arteries in relation to proximal stress. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Cerebrais , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Rigidez Vascular/fisiologia
4.
Neurointervention ; 15(3): 126-132, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33070511

RESUMO

PURPOSE: In acute middle cerebral artery (MCA) occlusion, collateral vessels provide retrograde supply to the occluded territory. We hypothesized that such collateral flow reduces perfusion of the non-occluded donor region (steal effect). MATERIALS AND METHODS: Patients with an MCA occlusion with opacification of both ipsi- and contralateral anterior cerebral arteries (ACA) on angiography prior to endovascular treatment were selected. Arteriovenous transit time (AVTT) for both ACA territories was compared for different grades of collateral supply to the MCA territory. In addition, the influence of diabetes and hypertension was analyzed. After successful revascularization, AVTT was re-assessed to determine reversibility. RESULTS: Forty-one patients were analyzed. An AVTT of 8.6 seconds (standard deviation [SD] 2.4 seconds) was seen in the ACA territory of the affected hemisphere in comparison to 6.6 seconds (SD 2.1 seconds) for the contralateral side (P<0.001). A more prolonged (but not significant) AVTT was seen in cases with a higher collateral grade. No difference in AVTT was seen in patients with diabetes or hypertension. After successful MCA revascularization, AVTT delay was 7.4 seconds (SD 2.1 seconds). CONCLUSION: A cerebral steal effect occurs in patients with an acute MCA occlusion, probably related to augmented flow to the penumbra area.

5.
Cardiovasc Pathol ; 35: 12-19, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29729633

RESUMO

Thrombospondin 4 (TSP-4) expression is induced in the heart and vasculature under pathological conditions, including myocardial infarction, myocardial pressure overload, and hypertension. TSP-4 is linked to remodelling processes, where it may affect extracellular matrix protein organization. In previous work, we studied the role of TSP-4 in small arteries during hypertension using Ang II-treated Thrombospondin 4 knockout (Thbs4-/-) mice. We reported increased heart weight, as well as the occurrence of aortic aneurysms in the Ang II-treated Thbs4-/- animals. In the present study, we further characterized the hearts and aortas from these animals. Hypertrophy of cardiomyocytes, together with perivascular fibrosis and inflammation was observed in the Ang II-treated Thbs4-/- hearts. In the aortas, an increase in the aortic wall cross-sectional area (CSA) and wall thickness of the Ang II-treated Thbs4-/- mice was found. More detailed investigation of the Ang II-treated Thbs4-/- aortas also revealed the appearance of aortic dissections in the outer medial layer of the arteries, as well as pronounced inflammation. No differences were found in several other extracellular matrix-related parameters, such as number of elastin breaks or stress-strain relationships. However, at the ultrastructural level, collagen fibers showed alterations in diameter in the media and adventitia of the Ang II-treated Thbs4-/- mice, in the area prone to dissection. In conclusion, we identified TSP-4 as an important protein in the development of cardiac hypertrophy and aortic dissections in Ang II-induced hypertension.


Assuntos
Angiotensina II , Aneurisma Aórtico/metabolismo , Dissecção Aórtica/metabolismo , Cardiomegalia/metabolismo , Hipertensão/metabolismo , Trombospondinas/metabolismo , Remodelação Vascular , Remodelação Ventricular , Dissecção Aórtica/induzido quimicamente , Dissecção Aórtica/genética , Dissecção Aórtica/patologia , Animais , Aorta/metabolismo , Aorta/ultraestrutura , Aneurisma Aórtico/induzido quimicamente , Aneurisma Aórtico/genética , Aneurisma Aórtico/patologia , Cardiomegalia/induzido quimicamente , Cardiomegalia/genética , Cardiomegalia/patologia , Dilatação Patológica , Modelos Animais de Doenças , Colágenos Fibrilares/metabolismo , Colágenos Fibrilares/ultraestrutura , Fibrose , Hipertensão/induzido quimicamente , Hipertensão/genética , Hipertensão/patologia , Camundongos Knockout , Miocárdio/metabolismo , Miocárdio/ultraestrutura , Trombospondinas/deficiência , Trombospondinas/genética
6.
Cardiovasc Intervent Radiol ; 39(2): 183-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26627485

RESUMO

PURPOSE: To report on the first clinical experience with perfusion angiography (PA) of the foot in patients with chronic critical limb ischemia. MATERIALS AND METHODS: PA is a post-processing software algorithm and no extra digital subtraction angiography (DSA) has to be performed for this analysis. The data used to test the feasibility of PA were obtained from a consecutive group of 89 patients with CLI who were treated with standard below the knee angioplasty and 12 separate patients who were not suitable for endovascular revascularization. RESULTS: Motion artifacts in the dataset of the DSA made post-procedural analysis impossible in 10 % intervention. In the majority of patients (59/68) PA showed an increase in volume flow in the foot after successful angioplasty of the crural vessels. However, in 9/68 patients no increase was seen after successful angioplasty. With the use of a local administered competitive α-adrenergic receptor antagonist, it is also possible to test and quantify the capillary resistance index which is a parameter for the remaining functionality of the microcirculation in CLI patients. CONCLUSION: PA might be used as a new endpoint for lower limb revascularization and can also be used to test the functionality the microcirculation to identify sub-types of patients with CLI. Clinical evaluation and standardization of PA is mandatory before introduction in daily practice.


Assuntos
Angiografia Digital/métodos , Pé/irrigação sanguínea , Isquemia/diagnóstico por imagem , Algoritmos , Angioplastia , Artefatos , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Isquemia/terapia , Masculino , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Ácidos Tri-Iodobenzoicos , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA