Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39299898

RESUMO

Transcatheter aortic valve replacement (TAVR) is preferred therapy for elderly patients with severe aortic stenosis (AS) and increasingly used in younger patient populations with good safety and efficacy outcomes. However, cardiac conduction abnormalities remain a frequent complication after TAVR ranging from relative benign interventriculair conduction delays to prognostically relevant left bundle branch block and complete atrio-ventricular (AV) block requiring permanent pacemaker implantation (PPI). Although clinical, procedural and electrocardiographic factors have been identified as predictors of this complication, there is a need for advanced strategies to control the burden of conduction defects particularly as TAVR shifts towards younger populations. This state of the art review highlights the value of ECG-synchronized computed tomographic angiography (CTA) evaluation of the aortic root to better understand and manage conduction problems post-TAVR. An update on CTA derived anatomic features related to conduction issues is provided and complemented with computational framework modelling. This CTA-derived 3-dimensional anatomical reconstruction tool generates patient-specific TAVR simulations enabling operators to adapt procedural strategy and implantation technique to mitigate conduction abnormality risks.

2.
Neth Heart J ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39283568

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning. AIMS: We aimed to illustrate the implementation of MSCT-derived modelling and simulations in the workup of TMVR for ViMAC, MViR, and MViV. METHODS: For this retrospective study, we included all consecutive patients screened for TMVR and compared MSCT data, echocardiographic outcomes and clinical outcomes. RESULTS: Sixteen out of 41 patients were treated with TMVR (ViMAC n = 9, MViR n = 3, MViV n = 4). Eleven patients were excluded for inappropriate sizing, 4 for anchoring issues and 10 for an unacceptable risk of left ventricular outflow tract obstruction (LVOTO) based on 3D modelling. There were 3 procedure-related deaths and 1 non-procedure-related cardiovascular death during 30 days of follow-up. LVOTO occurred in 3 ViMAC patients and 1 MViR patient, due to deeper valve implantation than planned in 3 patients, and anterior mitral leaflet displacement with recurrent basal septum thickening in 1 patient. TMVR significantly reduced mitral mean gradients as compared with baseline measurements (median mean gradient 9.5 (9.0-11.5) mm Hg before TMVR versus 5.0 (4.5-6.0) mm Hg after TMVR, p = 0.03). There was no residual mitral regurgitation at 30 days. CONCLUSION: MSCT-derived 3D modelling and simulation provide valuable anatomical insights for TMVR with transcatheter balloon expandable valves in ViMAC, MViR and MViV. Further planning iterations should target the persistent risk for neo-LVOTO.

3.
Struct Heart ; 8(5): 100279, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39290682

RESUMO

Moderate aortic stenosis is increasingly recognized as a disease entity with poor prognosis. Diagnosis of moderate aortic stenosis may be complemented by laboratory tests and advanced imaging techniques focused at detecting signs of cardiac damage such as increase of cardiac enzymes (N-terminal pro-B-type Natriuretic Peptide, troponin), left ventricular remodeling (hypertrophy, reduced left ventricular ejection fraction), or myocardial fibrosis. Therapy should include guideline-directed optimal medical therapy for heart failure. Patients with signs of cardiac damage may benefit from early intervention, which is the focus of several ongoing randomized controlled trials. As yet, no evidence-based therapy exists to halt the progression of aortic valve calcification.

4.
Interv Cardiol ; 19: e12, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39221063

RESUMO

The demonstrated safety and effectiveness of transcatheter aortic valve implantation (TAVI) among low surgical risk patients opened the road to its application in younger low-risk patients. However, the occurrence of conduction abnormalities and need for permanent pacemaker implantation remains a frequent problem associated with adverse outcomes. The clinical implications may become greater when TAVI shifts towards younger populations, highlighting the need for comprehensive strategies to address this issue. Beyond currently available clinical and electrocardiographic predictors, patient-specific anatomical assessment of the aortic root using multi-sliced CT (MSCT) imaging can refine risk stratification. Moreover, leveraging MSCT data for computational 3D simulations to predict device-anatomy interactions may help guide procedural strategy to mitigate conduction abnormalities. The aims of this review are to summarise the incidence and clinical impact of new left bundle branch block and permanent pacemaker implantation post-TAVI using contemporary transcatheter heart valves; and highlight the value of MSCT data interpretation to improve the management of this complication.

6.
Neth Heart J ; 32(10): 348-355, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39164507

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are < 75 years of age. We aim to compare patient characteristics and outcomes of TAVI and SAVR patients < 75 years. METHODS: This study included all patients < 75 years without active endocarditis undergoing TAVI or SAVR for severe aortic stenosis, mixed aortic valve disease or degenerated aortic bioprosthesis between 2015 and 2020 at the Erasmus University Medical Centre. Dutch authority guidelines were used to classify operative risk. RESULTS: TAVI was performed in 292 patients, SAVR in 386 patients. Based on the Dutch risk algorithm, 59.6% of TAVI patients and 19.4% of SAVR patients were at high operative risk. There was no difference in 30-day all-cause mortality between TAVI and SAVR (2.4% vs 0.8%, p = 0.083). One-year and 5­year mortality was higher after TAVI than after SAVR (1-year: 12.5% vs 4.3%, p < 0.001; 5­year: 36.8% vs 12.0%, p < 0.001). Within risk categories we found no difference between treatment strategies. Independent predictors of mortality were cardiovascular comorbidities (left ventricular ejection fraction < 30%, atrial fibrillation, pulmonary hypertension) and the presence of malignancies, liver cirrhosis or immunomodulatory drug use. CONCLUSION: At the Erasmus University Medical Centre, in patients < 75 years, TAVI is selected for higher-risk phenotypes and overall has higher long-term mortality than SAVR. We found no evidence for worse outcome within risk categories.

7.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38795109

RESUMO

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Ecocardiografia sob Estresse , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Curva ROC , Função Ventricular Esquerda , Área Sob a Curva , Volume Sistólico , Hemodinâmica
8.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38569793

RESUMO

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias , Humanos , Valor Preditivo dos Testes , Procedimentos Cirúrgicos Cardíacos/métodos , Simulação por Computador , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Software , Impressão Tridimensional
9.
JACC Case Rep ; 29(3): 102193, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361565

RESUMO

Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.

10.
Int J Cardiol ; 400: 131768, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211668

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
11.
Circ Cardiovasc Interv ; 16(11): e013296, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988436

RESUMO

BACKGROUND: Redo transcatheter aortic valve implantation (TAVI) is increasing as patients outlive their transcatheter heart valves (THVs) and present with bioprosthetic valve failure. The Lotus mechanically expanded THV has unique design characteristics, which have specific implications for Redo TAVI. METHODS: The design features of the Lotus valve and their relevance to Redo TAVI were reviewed. Bench-top analysis of Redo TAVI was performed using different contemporary THVs. Procedural and outcome data were obtained from 10 patients who had undergone Redo TAVI for Lotus bioprosthetic valve failure in 5 centers. Recommendations for performing Redo TAVI in Lotus are made, based on these findings. RESULTS: The Lotus leaflets extend from the frame inflow, with a Neoskirt of only 13 mm, hence a low risk of coronary obstruction during Redo TAVI. The Lotus frame posts prevent full apposition of the Redo prosthesis in the upper part of the frame, while implantation of the Redo THV above the Lotus inflow leads to inadequate apposition of the Lotus leaflets. Inflow-to-inflow positioning is therefore recommended for effective sealing and leaflet pinning. The Lotus locking mechanism prevents overexpansion of the frame, limiting Redo THV oversizing. Redo TAVI was favorable with SAPIEN 3, Evolut, and Navitor THVs on bench-top analysis but not with ACURATE Neo 2 due to the upper crowns and short stent preventing inflow-to-inflow deployment. Case review demonstrated satisfactory outcomes in 10 patients treated with Evolut (n=6), SAPIEN 3 (n=3), and Portico (n=1) valves, with no mortality, major morbidity, or coronary obstruction. Three patients had residual mean gradient ≥20 mm Hg, including 2 of 3 SAPIEN cases. Guidance on procedural planning, valve choice, sizing, and positioning is provided. CONCLUSIONS: Redo TAVI in Lotus requires an understanding of unique design characteristics, and adherence to key procedural recommendations, but can be safely and effectively performed with most contemporary valve types.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
12.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648345

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
13.
Struct Heart ; 6(5): 100084, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37288055

RESUMO

Background: Transcatheter valvular interventions affect cardiac and hemodynamic physiology by changing ventricular (un-)loading and metabolic demand as reflected by cardiac mechanoenergetics. Real-time quantifications of these changes are scarce. Pressure-volume loop (PVL) monitoring appraises both load-dependent and load-independent compounds of cardiac physiology including myocardial work, ventricular unloading, and ventricular-vascular interactions. The primary objective is to describe changes in physiology induced by transcatheter valvular interventions using periprocedural invasive biventricular PVL monitoring. The study hypothesizes transcatheter valve interventions modify cardiac mechanoenergetics that translate into improved functional status at 1-month and 1-year follow-up. Methods: In this single-center prospective study, invasive PVL analysis is performed in patients undergoing transcatheter aortic valve replacement or tricuspid or mitral transcatheter edge-to-edge repair. Clinical follow-up is per standard of care at 1 and 12 months. This study aims to include 75 transcatheter aortic valve replacement patients and 41 patients in both transcatheter edge-to-edge repair cohorts. Results: The primary outcome is the periprocedural change in stroke work, potential energy, and pressure-volume area (mmHg mL-1). The secondary outcomes comprise changes in a myriad of parameters obtained by PVL measurements, including ventricular volumes and pressures and the end-systolic elastance-effective arterial elastance ratio as a reflection of ventricular-vascular coupling. A secondary endpoint associates these periprocedural changes in cardiac mechanoenergetics with functional status at 1 month and 1 year. Conclusions: This prospective study aims to elucidate the fundamental changes in cardiac and hemodynamic physiology during contemporary transcatheter valvular interventions.

14.
Int J Cardiovasc Imaging ; 34(5): 743-749, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29234934

RESUMO

Left ventricular (LV) diastolic dysfunction is one of the important mechanisms responsible for symptoms in patients with heart failure. The aim of the current study was to identify parameters that may be used to detect early signs of LV diastolic dysfunction in diabetic pigs on a high fat diet, using conventional and speckle tracking echocardiography. The study population consisted of 16 healthy Göttingen minipigs and 18 minipigs with experimentally induced metabolic dysfunction. Echocardiography measurements were performed at baseline and 3-month follow-up. The ratio of peak early (E) and late filling velocity (E/A ratio) and the ratio of E and the velocity of the mitral annulus early diastolic wave (E/Em ratio) did not change significantly in both groups. Peak untwisting velocity decreased in the metabolic dysfunction group (- 30.1 ± 18.5 vs. - 23.4 ± 15.5 °/ms) but not in controls (- 38.1 ± 23.6 vs. - 42.2 ± 23.0 °/ms), being significantly different between the groups at the 3-month time point (p < 0.05). In conclusion, whereas E/A ratio and E/Em ratio did not change significantly after 3 months of metabolic dysfunction, peak untwisting velocity was significantly decreased. Hence, peak untwisting velocity may serve as an important marker to detect early changes of LV diastolic dysfunction.


Assuntos
Diabetes Mellitus Experimental/complicações , Ecocardiografia Doppler , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Animais , Fenômenos Biomecânicos , Diabetes Mellitus Experimental/diagnóstico , Diástole , Diagnóstico Precoce , Valor Preditivo dos Testes , Suínos , Porco Miniatura , Fatores de Tempo , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
15.
J Am Heart Assoc ; 5(11)2016 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-27852591

RESUMO

BACKGROUND: Marfan syndrome (MFS) and familial non-syndromal thoracic aortic aneurysm and dissection (ns-TAAD) are genetic aortopathies causing aortic dilatation with increased aortic stiffness. Left ventricular (LV) contractility and ventricular-vascular coupling index (VVI) were compared between MFS and ns-TAAD and determinants of VVI were investigated. METHODS AND RESULTS: Patients with MFS (M 57, F 47) and ns-TAAD (M 72, F 39) were studied by echocardiography and compared with controls (M 77, F 71). Aortic geometry, hemodynamics, LV work, LV contractility (end-systolic elastance [Ees]), and VVI were documented. Aortic sinuses were equally dilated in MFS (19.7±2.4) and ns-TAAD (19.8±1.8) compared to controls (16.2±1.4 mm·m-2, P<0.001). Aortic stiffness index was increased in MFS (9.7±5.1) and ns-TAAD (10.8±4.7) versus controls (5.4±2.0, P<0.01); LV stroke work was unchanged in MFS (436±74) compared to controls (435±60) but increased in ns-TAAD (492±109 mJ·m-2 P<0.01). The LV Ees was reduced in MFS (1.32±0.19) compared to controls (1.65±0.29 mm Hg·mL-1, P<0.01) but increased in ns-TAAD (1.83±0.30, P<0.01) and VVI was abnormal in MFS (0.71±0.11) compared to controls (0.62±0.07, P<0.01) and ns-TAAD (0.62±0.09). Treatment with ß-blockers was associated with partial normalization of VVI in MFS. A VVI ≥0.8 was associated with increased risk of death and heart failure in MFS. CONCLUSIONS: Left ventricular contractility and ventricular-vascular coupling are abnormal in MFS but preserved in ns-TAAD, and are independent of aortic stiffness, consistent with intrinsic impairment of myocardial contractility in MFS.


Assuntos
Aneurisma da Aorta Torácica/fisiopatologia , Ventrículos do Coração , Síndrome de Marfan/fisiopatologia , Contração Miocárdica , Rigidez Vascular , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Aneurisma da Aorta Torácica/tratamento farmacológico , Aneurisma da Aorta Torácica/etiologia , Austrália/epidemiologia , Dilatação Patológica , Ecocardiografia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/epidemiologia , Hemodinâmica , Humanos , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/tratamento farmacológico , Pessoa de Meia-Idade , Mortalidade , Seio Aórtico/patologia , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA