Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Food Chem (Oxf) ; 5: 100128, 2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36035445

RESUMO

The present study aimed to identify the regulatory mechanisms of red, blue, and white light on carotenoid biosynthesis in maize sprouts. Determinations of carotenoid, chlorophyll and phytohormone profiles, as well as relative gene expression, were explored. The results identified enhancement of carotenoid and chlorophyll production as well as gene expression. Most notably, the expression levels of CRY, HY5, and beta-carotene 3-hydroxylase genes peaked under blue light. Photomorphogene-related hormone, auxins and strigolactone production was also altered under different lights and might have a role in carotenoid metabolism. Gibberellins competed with carotenoids for the precursor geranylgeranyl diphosphate and were hindered by certain light characteristics, probably via DELLA-PIF4 signalling. ERF021 and MYB68 were negative regulators of carotenoid biosynthesis in maize sprouts. These findings provide new insights into the light-regulated mechanism and biofortification of carotenoids in maize sprouts.

2.
Comput Struct Biotechnol J ; 20: 3621-3629, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35860414

RESUMO

When hearing fails, electrical cochlear implants (eCIs) partially restore hearing by direct stimulation of spiral ganglion neurons (SGNs). As light can be better confined in space than electrical current, optical CIs (oCIs) provide more spectral information promising a fundamental improvement of hearing restoration by cochlear implants. Here, we turned to computer modelling for predicting the outcome of optogenetic hearing restoration by future oCIs in humans. We combined three-dimensional reconstruction of the human cochlea with ray-tracing simulation of emission from LED or laser-coupled waveguide emitters of the oCI. Irradiance was read out at the somata of SGNs. The irradiance values reached with waveguides were about 14 times higher than with LEDs, at the same radiant flux of the emitter. Moreover, waveguides outperformed LEDs regarding spectral selectivity. oCIs with either emitter type showed greater spectral selectivity when compared to eCI. In addition, modeling the effects of the source-to-SGN distance, orientation of the sources and impact of scar tissue further informs the development of optogenetic hearing restoration.

3.
Pol J Vet Sci ; 25(2): 249-259, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35861955

RESUMO

The aim of this study was to determine the time-dependent effectiveness of photo-stimulation against bovine sperm cells using a multi-wavelength LED (Light Emitting Diode). Spermatological parameters were evaluated for viability, acrosome structure and motility. In addition, the effect of photo-stimulation on frozen-thawed sperm cells subjected to in vitro capacitation was evaluated in terms of changes in mitochondrial membrane potential. The study consisted of two separate experiments and a total of 32 sperm samples obtained from separate bulls were used. All sperm samples were obtained from Holstein bulls using an artificial vagina. Semen was diluted to a final concentration of 92 x 106 spermatozoa per ml in 0.25 ml straws. The sperm cells were frozen using the conventional method. Straws were kept in a 37°C water bath for 20 seconds and diluted 1:4 in phosphate buffered saline (PBS) to eliminate the potentially deleterious effect of glycerol, the main permeable cryoprotectant in the freezing medium for bull sperm. This dilution also helped in the evaluation of sperm quality parameters. In the first experiment, whereas the 15-10-15 showed no differences with the control, other treatments such as 10-10-10, 5-5-5, and 3-1-3 exhibited significantly higher percentages of viable spermatozoa at 24h. The results obtained for acrosome integrity were pretty much similar to those observed in the sperm viability assessment. In effect, while the treatment consisting of 15-10-15 had no positive effects, shorter treatments exerted a much more positive effect. The percentages of acrosome-intact spermatozoa in 2-1-2 and 1-1-1 were significantly higher than those obtained in the control. The significant differences in mitochondrial membrane potential were observed at 0, 2, 4 and 24h post-photo-stimulation in all treatments, except 15-10-15. The highest increase in the percentage of spermatozoa exhibiting high mitochondrial membrane potential was found in 10-10-10, 5-5-5 and 3-1-3 treatments. With regard to total and progressive motility, whereas 10-10-10 was the best regime, 5-5-5 and 3-1-3 treatments also had a positive effect. However, 15-10-15 appeared to have a stimulating effect upon progressive motility at 2h and 4h but later declined and showed no significant differences with regard to the control at 24h. In the second experiment, not immediately after thawing but after having been kept at room temperature for up to 24h, it was observed that there was no statistical difference in terms of viability, acrosome integrity and total/progressive motility between photostimulation and the control group. This indicates that photo- stimulation is less able to exert a beneficial effect when post-thawed sperm are not immediately stimulated. As a result it was determined that photo-stimulation at a pattern of 10-10-10, 5-5-5, 3-1-3 and, to a lesser extent 2-1-2, increases the resilience of frozen-thawed bull sperm when applied upon thawing.


Assuntos
Preservação do Sêmen , Animais , Bovinos , Criopreservação/veterinária , Feminino , Congelamento , Masculino , Sêmen/fisiologia , Preservação do Sêmen/métodos , Preservação do Sêmen/veterinária , Motilidade dos Espermatozoides , Espermatozoides/fisiologia
4.
Sens Actuators B Chem ; 362: 131764, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35370362

RESUMO

The pandemic of the novel coronavirus disease 2019 (COVID-19) is continuously causing hazards for the world. Effective detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can relieve the impact, but various toxic chemicals are also released into the environment. Fluorescence sensors offer a facile analytical strategy. During fluorescence sensing, biological samples such as tissues and body fluids have autofluorescence, giving false-positive/negative results because of the interferences. Fluorescence near-infrared (NIR) nanosensors can be designed from low-toxic materials with insignificant background signals. Although this research is still in its infancy, further developments in this field have the potential for sustainable detection of SARS-CoV-2. Herein, we summarize the reported NIR fluorescent nanosensors with the potential to detect SARS-CoV-2. The green synthesis of NIR fluorescent nanomaterials, environmentally compatible sensing strategies, and possible methods to reduce the testing frequencies are discussed. Further optimization strategies for developing NIR fluorescent nanosensors to facilitate greener diagnostics of SARS-CoV-2 for pandemic control are proposed.

5.
Lancet Reg Health West Pac ; 22: 100407, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35243461

RESUMO

Five billion people lack access to surgical care worldwide; climate change is the biggest threat to human health in the 21st century. This review studies how climate change could be integrated into national surgical planning in the Western Pacific region. We searched databases (PubMed, Web of Science, and Global Health) for articles on climate change and surgical care. Findings were categorised using the modified World Health Organisation Health System Building Blocks Framework. 220 out of 2577 records were included. Infrastructure: Operating theatres are highly resource-intensive. Their carbon footprint could be reduced by maximising equipment longevity, improving energy efficiency, and renewable energy use. Service delivery Tele-medicine, outreaches, and avoiding desflurane could reduce emissions. Robust surgical systems are required to adapt to the increasing burden of surgically treated diseases, such as injuries from natural disasters. Finance: Climate change adaptation funds could be mobilised for surgical system strengthening. Information systems: Sustainability should be a key performance indicator for surgical systems. Workforce: Surgical providers could change clinical, institutional, and societal practices. Governance: Planning in surgical care and climate change should be aligned. Climate change mitigation is essential in the regional surgical care scale-up; surgical system strengthening is also necessary for adaptation to climate change.

6.
J Hazard Mater Adv ; 8: 100183, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36619826

RESUMO

The COVID-19 pandemic highlighted public awareness of airborne disease transmission in indoor settings and emphasized the need for reliable air disinfection technologies. This increased awareness will carry in the post-pandemic era along with the ever-emerging SARS-CoV variants, necessitating effective and well-defined protocols, methods, and devices for air disinfection. Ultraviolet (UV)-based air disinfection demonstrated promising results in inactivating viral bioaerosols. However, the reported data diversity on the required UVC doses has hindered determining the best UVC practices and led to confusion among the public and regulators. This article reviews available information on critical parameters influencing the efficacy of a UVC air disinfection system and, consequently, the required dose including the system's components as well as operational and environmental factors. There is a consensus in the literature that the interrelation of humidity and air temperature has a significant impact on the UVC susceptibility, which translate to changing the UVC efficacy of commercialized devices in indoor settings under varying conditions. Sampling and aerosolization techniques reported to have major influence on the result interpretation and it is recommended to use several sampling methods simultaneously to generate comparable and conclusive data. We also considered the safety concerns and the potential safe alternative of UVC, far-UVC. Finally, the gaps in each critical parameter and the future research needs of the field are represented. This paper is the first step to consolidating literature towards developing a standard validation protocol for UVC air disinfection devices which is determined as the one of the research needs.

7.
Sensors (Basel) ; 21(20)2021 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-34696155

RESUMO

Acne is a dermatosis that affects almost 90% of the adolescent population worldwide and its treatment is performed with retinoids, antimicrobials, acids, and topical or systemic antibiotics. Side effects such as skin irritation in addition to microbial resistance to antibiotics are the main side effects found. Phototherapy with blue light is being used as an alternative treatment. Our objective was to analyze the use of blue light to treat inflammatory acne. We conducted a systematic literature review, following the recommendation PRISMA (Preferred Reporting Items for Systematic Reviews and MetaAnalyses), including in the sample randomized clinical trial studies that compared blue light with another intervention as control. The research was carried out in the PUBMED and WEB of SCIENCE databases and the methodological quality of the studies evaluated were made by the Cochrane Collaboration Bias Risk Scale. After the exclusion of duplicates, the titles and abstracts of 81 articles were evaluated, and 50 articles were selected for full reading, including in the review at the end 8 articles. Studies have shown significant improvements in the overall picture of acne. It is concluded that despite the great potential in its use in the treatment of acne, there is a need for more detailed trials on the effect of blue light on the treatment of inflammatory acne.


Assuntos
Acne Vulgar , Acne Vulgar/terapia , Adolescente , Antibacterianos , Gerenciamento de Dados , Humanos , Luz , Fototerapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
8.
Neurobiol Sleep Circadian Rhythms ; 10: 100066, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33997475

RESUMO

The magnitude of the stimulus to the biological clock will depend upon the distribution of circadian phototransduction circuits across the retinae and the spatial distribution of luminous stimuli in the environment. The present study compared nocturnal melatonin suppression for light exposures to the superior, inferior, nasal, and temporal retina in one eye independent of shading from the brow and the nose. The stimulus was a 40° diameter luminous disc, half of which was blue light (LED, λpeak = 470 nm) and the other amber light (LED, λpeak = 590 nm). Experimentally, the orientation of the bipartite disc was rotated to each of the four cardinal points of the visual field. A full, 40° blue disc was also employed by replacing the amber half-disc with another blue half-disc. The blue full- and half-discs always produced 100 photopic lx at the cornea. As hypothesized, nocturnal melatonin suppression was statistically greatest when the blue half-disc was delivered to the nasal hemi-field (35%); the other three hemi-fields were equally affected by the blue half-disc (≈20%). Melatonin suppression for the full-disc was 24%, which was not statistically different than the average suppression for the four hemi-fields of 27%.

9.
Micromachines (Basel) ; 12(4)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808493

RESUMO

In this study, near-infrared (NIR) technology was utilized to develop a low-cost real-time near infrared (NIR) guiding device for cannulation. A portable device that can be used by medical practitioners and also by students for their skills development training in performing cannulation. METHODS: First, is the development of a reflectance type optical vein finder using three (3) light emitting diode (LED) lights with 960 nm wavelength, complementary metal-oxide-semiconductor-infrared (CMOS-IR) sensor camera with 1920 × 1080 UXGA (1080P), IR filter set for the given wavelength, and an open-source image processing software. Second, is the actual in-vitro human testing in two sites: the arm and dorsal hand of 242 subjects. The following parameters were included, such as gender, age, mass index (BMI), and skin tone. In order to maximize the assessment process towards the device, the researchers included the arm circumference. This augmented subcutaneous vein imaging study using the develop vein finder device compared the difference in the captured vein images through visual and digital imaging approaches. The human testing was performed in accordance with the ethical standards of the Trinity University of Asia-Institutional Ethics Review Committee (TUA-IERC). RESULTS: The NIR imaging system of the developed vein finder in this study showed its capability as an efficient guiding device through real-time vein pattern recognition, for both sites. Improved captured vein images were observed, having 100% visibility of vein patterns on the dorsal hand site. Fourteen (5.79%) out of 242 subjects reported non-visible peripheral subcutaneous veins in the arm sites. CONCLUSIONS: The developed vein finder device with the NIR technology and reflected light principle with low-energy consumption was efficient for real-time peripheral subcutaneous vein imaging without the application of a tourniquet. This might be utilized as a guiding device in locating the vein for the purpose of cannulation, at a very low cost as compared to the commercially available vein finders. Moreover, it may be used as an instructional device for student training in performing cannulation.

10.
Coord Chem Rev ; 426: 213544, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32981945

RESUMO

Progress in metal-organic frameworks (MOFs) has advanced from fundamental chemistry to engineering processes and applications, resulting in new industrial opportunities. The unique features of MOFs, such as their permanent porosity, high surface area, and structural flexibility, continue to draw industrial interest outside the traditional MOF field, both to solve existing challenges and to create new businesses. In this context, diverse research has been directed toward commercializing MOFs, but such studies have been performed according to a variety of individual goals. Therefore, there have been limited opportunities to share the challenges, goals, and findings with most of the MOF field. In this review, we examine the issues and demands for MOF commercialization and investigate recent advances in MOF process engineering and applications. Specifically, we discuss the criteria for MOF commercialization from the views of stability, producibility, regulations, and production cost. This review covers progress in the mass production and formation of MOFs along with future applications that are not currently well known but have high potential for new areas of MOF commercialization.

11.
HardwareX ; 10: e00232, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35607665

RESUMO

The past four decades have brought significant and increasingly rapid changes to the world of instrument design, fabrication, and availability due to the emergence of 3D printing, open-source code and equipment, and low-cost electronics. These, along with other technological advances represent a nexus in time ripe for the wide-spread production and availability of low-cost sophisticated scientific equipment. To that end, the design of a 3D printable and open-source, modular spectrometer is described. This specific instrument is distinctly different from others that have been reported in recent years in that it was designed outside of the "black box" paradigm of nearly all other commercially available and open-source spectrometers. This feature along with its design to be produced on low-end consumer-grade 3D printers and with parts available at nearly any local hardware store allow this instrument to further erode current barriers to instrument access. Additionally, the use cases presented here demonstrate similar capabilities to commercially available equipment at a fraction of the cost.

12.
J Res Natl Inst Stand Technol ; 126: 126034, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-39015627

RESUMO

Limited sources exist for the application of germicidal ultraviolet (GUV) radiation. Ultraviolet light-emitting diodes (UV-LEDs) have significantly improved in efficiency and are becoming another viable source for GUV. We have developed a mean differential continuous pulse method (M-DCP method) for optical measurements of light-emitting diodes (LEDs) and laser diodes (LDs). The new M-DCP method provides an improvement on measurement uncertainty by one order of magnitude compared to the unpublished differential continuous pulse method (DCP method). The DCP method was already a significant improvement of the continuous pulse method (CP method) commonly used in the LED industry. The new M-DCP method also makes it possible to measure UV-LEDs with high accuracy. Here, we present the DCP method, discuss the potential systematic error sources in it, and present the M-DCP method along with its reduced systematic errors. This paper also presents the results of validation measurement of LEDs using the M-DCP method and common test instruments.

13.
Biotechnol Rep (Amst) ; 28: e00563, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33304839

RESUMO

Anoxygenic phototrophic bacteria (APB) are a phylogenetically diverse group of organisms that can harness solar energy for their growth and metabolism. These bacteria vary broadly in terms of their metabolism as well as the composition of their photosynthetic apparatus. Unlike oxygenic phototrophic bacteria such as algae and cyanobacteria, APB can use both organic and inorganic electron donors for light-dependent fixation of carbon dioxide without generating oxygen. Their versatile metabolism, ability to adapt in extreme conditions, low maintenance cost and high biomass yield make APB ideal for wastewater treatment, resource recovery and in the production of high value substances. This review highlights the advantages of APB over algae and cyanobacteria, and their applications in photo-bioelectrochemical systems, production of poly-ß-hydroxyalkanoates, single-cell protein, biofertilizers and pigments. The ecology of ABP, their distinguishing factors, various physiochemical parameters governing the production of high-value substances and future directions of APB utilization are also discussed.

14.
Biotechnol Rep (Amst) ; 27: e00497, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32695616

RESUMO

Gas-chromatography-mass-spectrometry revealed the presence of various bioactive compounds with anticancer properties in protocorm-like-body (PLB) cultures of a Dendrobium hybrid orchid (Dendrobium Enopi x Dendrobium Pink Lady). Pre-illumination of red fluorescent light lessened the stimulating effects of light-emitting diodes (LEDs) on secondary metabolites production among in vitro PLB cultures, possibly due to habituation. The highest flavonoid content of 16.79 µmol/ g of fresh weight (FW) was achieved under blue-red (1:1) LED for PLBs pre-treated with white LED for more than 3 subculture cycles. Phenolics content significantly reduced as PLBs pre-cultured under red fluorescent light for 2 subculture cycles were exposed to LED illuminations, where far red LED resulted in the lowest total phenolic content (18.85 µmol/ g FW). High intensity green LED (16.9 µmol/s) enhanced the accumulation of phenolics while amino acids such as L-leucine, glycine and proline exhibited no significant stimulating effect for secondary metabolites production.

15.
Resour Conserv Recycl ; 157: 104772, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32494109

RESUMO

Currently, in the European Union (EU), e-waste chain performance is assessed by technical indicators that aim to ensure system compliance with collection and recovery targets set by the WEEE Directive. This study proposes indicators to improve WEEE flow monitoring beyond the current overall weight-based approach, including complementary flows and treatment performance. A case study focused on the screen category in France is presented. In 2017, the collection rate of cathode-ray tube screens (CRT) was 68%, while for flat panel display (FPD) generated only 14% was collected. CRT screens have less precious and critical materials than FDP. Thus, elements like cobalt and gold highly concentrated in FPD, have a collection rate two to four times lower than elements such as copper (37%) which represents a high proportion in CRTs. Recycling is the main treatment in France. Nevertheless, the recycling rate per element varies significantly due to the low collection, and also the lack of technology and/or secondary raw materials market. The elements with higher recycling rates are base metals such as copper (28%), followed by precious metals like silver (23%), and gold (13%). Except for palladium, the recycling rate of the critical raw materials targeted in the study ranged from 6% (cobalt) to 0% (e.g. neodymium and indium). The results stress the need for indicators to support the development of WEEE chain from waste management to secondary (critical) raw materials suppliers.

16.
Photoacoustics ; 16: 100144, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31871888

RESUMO

Photoacoustic imaging (or optoacoustic imaging) is an upcoming biomedical imaging modality availing the benefits of optical resolution and acoustic depth of penetration. With its capacity to offer structural, functional, molecular and kinetic information making use of either endogenous contrast agents like hemoglobin, lipid, melanin and water or a variety of exogenous contrast agents or both, PAI has demonstrated promising potential in a wide range of preclinical and clinical applications. This review provides an overview of the rapidly expanding clinical applications of photoacoustic imaging including breast imaging, dermatologic imaging, vascular imaging, carotid artery imaging, musculoskeletal imaging, gastrointestinal imaging and adipose tissue imaging and the future directives utilizing different configurations of photoacoustic imaging. Particular emphasis is placed on investigations performed on human or human specimens.

18.
Jpn Dent Sci Rev ; 55(1): 126-138, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31687052

RESUMO

This review article compiles the characteristics of resin based dental composites and an effort is made to point out their future perspectives. Recent research studies along with few earlier articles were studied to compile the synthesis schemes of commonly used monomers, their characteristics in terms of their physical, mechanical and polymerization process with selectivity towards the input parameters of polymerization process. This review covers surface modification processes of various filler particles using silanes, wear behaviour, antimicrobial behaviour along with its testing procedures to develop the fundamental knowledge of various characteristics of resin based composites. In the end of this review, possible areas of further interests are pointed out on the basis of literature review on resin based dental materials.

19.
Sensors (Basel) ; 19(16)2019 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-31426370

RESUMO

One of the most common means for diagnosis is through medical laboratory testing, which primarily uses venous blood as a sample. This requires an invasive method by cannulation that needs proper vein selection. The use of a vein finder would help the phlebotomist to easily locate the vein, preventing possible pre-analytical error in the specimen collection and even more discomfort and pain to the patient. This paper is a review of the scientific publications on the different developed low-cost vein finder prototypes utilizing camera assisted near infrared (NIR) light technology. Methods: Electronic databases were searched online, these included PubMed (PMC), MEDLINE, Science Direct, ResearchGate, and Institute of Electrical and Electronics Engineers (IEEE) Xplore digital library. Specifically, publications with the terms vein finder prototype, NIR technology, vein detection, and infrared imaging were screened. In addition, reference lists were used to further review related publications. Results: Cannulation challenges medical practitioners because of the different factors that can be reduced by the utilization of a vein finder. A limited number of publications regarding the assessment of personnel performing cannulation were observed. Moreover, variations in methodology, number of patients, type of patients according to their demographics and materials used in the assessment of the developed prototypes were noted. Some studies were limited with regard to the actual human testing of the prototype. Conclusions: The development of a low-cost effective near infrared (NIR) vein finder remains in the phase of improvement. Since, it is being challenged by different human factors, increasing the number of parameters and participants/human for actual testing of the prototypes must also be taken into consideration for possible commercialization. Finally, it was noted that publications regarding the assessment of the performance of phlebotomists using vein finders were limited.


Assuntos
Flebotomia/métodos , Veias/fisiologia , Cateterismo , Análise Custo-Benefício , Humanos , Flebotomia/instrumentação , Semicondutores , Espectroscopia de Luz Próxima ao Infravermelho , Veias/anatomia & histologia
20.
Rep Pract Oncol Radiother ; 24(4): 383-391, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31297039

RESUMO

AIM: To investigate tumour motion tracking uncertainties in the CyberKnife Synchrony system with single fiducial marker in liver tumours. BACKGROUND: In the fiducial-based CyberKnife real-time tumour motion tracking system, multiple fiducial markers are generally used to enable translation and rotation corrections during tracking. However, sometimes a single fiducial marker is employed when rotation corrections are not estimated during treatment. MATERIALS AND METHODS: Data were analysed for 32 patients with liver tumours where one fiducial marker was implanted. Four-dimensional computed tomography (CT) scans were performed to determine the internal target volume (ITV). Before the first treatment fraction, the CT scans were repeated and the marker migration was determined. Log files generated by the Synchrony system were obtained after each treatment and the correlation model errors were calculated. Intra-fractional spine rotations were examined on the spine alignment images before and after each treatment. RESULTS: The mean (standard deviation) ITV margin was 4.1 (2.3) mm, which correlated weakly with the distance between the fiducial marker and the tumour. The mean migration distance of the marker was 1.5 (0.7) mm. The overall mean correlation model error was 1.03 (0.37) mm in the radial direction. The overall mean spine rotations were 0.27° (0.31), 0.25° (0.22), and 0.23° (0.26) for roll, pitch, and yaw, respectively. The treatment time was moderately associated with the correlation model errors and weakly related to spine rotation in the roll and yaw planes. CONCLUSIONS: More caution and an additional safety margins are required when tracking a single fiducial marker.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA