Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Front Cardiovasc Med ; 11: 1399110, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39105074

RESUMO

Objectives: The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients. Methods: Between July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization. Results: A total of 24 patients (aged 3-15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 ± 0.396, while 4D flow measured it at 1.403 ± 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 ± 0.283. Conclusion: 4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.

2.
Materials (Basel) ; 16(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37109954

RESUMO

The rise in the connectivity of the fractures is a key task in oil/gas and geothermal exploitation systems. Natural fractures widely exist in underground reservoir sandstone, while the mechanical behavior of rock with fractures subjected to hydro-mechanical coupling loads is far from clear. This paper employed comprehensive experiments and numerical simulations to investigate the failure mechanism and permeability law for sandstone specimens with T-shaped faces subjected to hydro-mechanical coupling loads. The effects of crack closure stress, crack initiation stress, strength, and axial strain stiffness of the specimens under different fracture inclination angles are discussed, and the evolution processes of permeability are obtained. The results show that secondary fractures are created around the pre-existing T-shaped fractures through tensile, shear, or mixed modes. The fracture network causes an increase in the permeability of the specimen. T-shaped fractures have a more significant effect on the strength of the specimens than water. The peak strengths of T-shaped specimens decreased by 34.89%, 33.79%, 46.09%, 39.32%, 47.23%, 42.76%, and 36.02%, respectively, compared with intact specimen without water pressure. With the increase in deviatoric stress, the permeability of T-shaped sandstone specimens decreases first, then increases, reaching its maximum value when macroscopic fractures are formed, after which the stress suddenly decreases. When the prefabricated T-shaped fracture angle is 75°, the corresponding permeability of the sample at failure is maximum, with a value of 15.84 × 10-16 m2. The failure process of the rock is reproduced through numerical simulations, in which the influence of damage and macroscopic fractures on permeability is discussed.

3.
Nanomaterials (Basel) ; 12(19)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36234399

RESUMO

In a magnetic field, two-dimensional (2D) mixed convection is investigated within a zigzagged trapezoidal chamber. The lower side of the trapezoidal chamber is irregular, in particular, a zigzagged wall with different zigzag numbers N. The fluid particles move in the room due to the motion of the upper wall, while the porosity-enthalpy approach represents the melting process. The thermal parameters of the fluid are enhanced by what is called a nano-encapsulated phase change material (NEPCM) consisting of polyurethane as the shell and a nonadecane as the core, while water is used as the base fluid. In order to treat the governing equations, the well-known Galerkin finite element method (GFEM) is applied. In addition, the heat transfer (HT) irreversibility and the fluid friction (FF) irreversibility are compared in terms of the average Bejan number. The main results show that the melt band curve behaves parabolically at smaller values of Reynolds number (Re) and larger values of Hartmann number (Ha). Moreover, minimizing the wave number is better in order to obtain a higher heat transfer rate.

4.
Front Bioeng Biotechnol ; 9: 725833, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869250

RESUMO

Magnetic resonance imaging (MRI) can potentially be used for non-invasive screening of patients with stable angina pectoris to identify probable obstructive coronary artery disease. MRI-based coronary blood flow quantification has to date only been performed in a 2D fashion, limiting its clinical applicability. In this study, we propose a framework for coronary blood flow quantification using accelerated 4D flow MRI with respiratory motion correction and compressed sensing image reconstruction. We investigate its feasibility and repeatability in healthy subjects at rest. Fourteen healthy subjects received 8 times-accelerated 4D flow MRI covering the left coronary artery (LCA) with an isotropic spatial resolution of 1.0 mm3. Respiratory motion correction was performed based on 1) lung-liver navigator signal, 2) real-time monitoring of foot-head motion of the liver and LCA by a separate acquisition, and 3) rigid image registration to correct for anterior-posterior motion. Time-averaged diastolic LCA flow was determined, as well as time-averaged diastolic maximal velocity (VMAX) and diastolic peak velocity (VPEAK). 2D flow MRI scans of the LCA were acquired for reference. Scan-rescan repeatability and agreement between 4D flow MRI and 2D flow MRI were assessed in terms of concordance correlation coefficient (CCC) and coefficient of variation (CV). The protocol resulted in good visibility of the LCA in 11 out of 14 subjects (six female, five male, aged 28 ± 4 years). The other 3 subjects were excluded from analysis. Time-averaged diastolic LCA flow measured by 4D flow MRI was 1.30 ± 0.39 ml/s and demonstrated good scan-rescan repeatability (CCC/CV = 0.79/20.4%). Time-averaged diastolic VMAX (17.2 ± 3.0 cm/s) and diastolic VPEAK (24.4 ± 6.5 cm/s) demonstrated moderate repeatability (CCC/CV = 0.52/19.0% and 0.68/23.0%, respectively). 4D flow- and 2D flow-based diastolic LCA flow agreed well (CCC/CV = 0.75/20.1%). Agreement between 4D flow MRI and 2D flow MRI was moderate for both diastolic VMAX and VPEAK (CCC/CV = 0.68/20.3% and 0.53/27.0%, respectively). In conclusion, the proposed framework of accelerated 4D flow MRI equipped with respiratory motion correction and compressed sensing image reconstruction enables repeatable diastolic LCA flow quantification that agrees well with 2D flow MRI.

5.
J Cardiovasc Magn Reson ; 23(1): 132, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34775954

RESUMO

BACKGROUND: Aortic valve stenosis (AS) is the most prevalent valvular disease in the developed countries. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is an emerging imaging technique, which has been suggested to improve the evaluation of AS severity compared to two-dimensional (2D) flow and transthoracic echocardiography (TTE). We investigated the reliability of CMR 2D flow and 4D flow techniques in measuring aortic transvalvular peak systolic flow in patients with severe AS. METHODS: We prospectively recruited 90 patients referred for aortic valve replacement due to severe AS (73.3 ± 11.3 years, aortic valve area 0.7 ± 0.1 cm2, and 54/36 tricuspid/bicuspid), and 10 non-valvular disease controls. All the patients underwent echocardiography and 2D flow and 4D flow CMR. Peak flow velocity measurements were compared using Wilcoxon signed rank sum test and Bland-Altman analysis. RESULTS: 4D flow underestimated peak flow velocity in the AS group when compared with TTE (bias - 1.1 m/s, limits of agreement ± 1.4 m/s) and 2D flow (bias - 1.2 m/s, limits of agreement ± 1.6 m/s). The differences between values obtained by TTE (median 4.3 m/s, range 2.7-6.1 m/s) and 2D flow (median 4.5 m/s, range 2.9-6.5 m/s) compared to 4D flow (median 3.1 m/s, range 1.7-5.1 m/s) were significant (p < 0.001). The difference between 2D flow and TTE were insignificant (bias 0.07 m/s, limits of agreement ± 1.5 m/s). In non-valvular disease controls, peak flow velocity was measured higher by 4D flow than 2D flow (1.4 m/s, 1.1-1.7 m/s and 1.3 m/s, 1.1-1.5 m/s, respectively; bias 0.2 m/s, limits of agreement ± 0.16 m/s). CONCLUSIONS: CMR 4D flow significantly underestimates systolic peak flow velocity in patients with severe AS. 2D flow, in turn, estimated the AS velocity accurately, with measured peak flow velocities comparable to TTE.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Environ Pollut ; 284: 117473, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062431

RESUMO

Oil spills occurring either in oceans or inland waterways may cause serious economic losses and ecological damage. Previous studies pertaining to oil spills and their consequences are primarily based on marine environments, whereas few have focused on oil spills occurring in inland waterways characterised by pronounced flow advection transport effects, which differ from the marine environment. A generalised flume experiment is performed to investigate the spread and transport of oil spills, and the relationships between the area and thickness of oil slick over time are analysed parametrically. An oil spill model combined with a depth-integrated two-dimensional non-uniform flow model, which is suitable for modelling inland waterways based on the Lagrangian method, is established; it is calibrated and verified using measured data from the flume experiment. The model is applied to three scenarios on the Luoqi reach of the Yangtze River, and spilled oil drifting trajectory maps are obtained and analysed considering the field wind parameters. The results show that the drift distance of the oil slick in the inland waterway is primarily controlled by the flow velocity with effects of advection transport; however, the oil spill trajectory spreads toward the wind direction when the flow velocity is relatively small compared with the wind speed. The results of this study serve as a reference for predicting the spread and transport of oil spills in inland waterways.


Assuntos
Poluição por Petróleo , Petróleo , Poluentes Químicos da Água , Monitoramento Ambiental , Oceanos e Mares , Petróleo/análise , Poluição por Petróleo/análise , Poluentes Químicos da Água/análise
7.
Environ Monit Assess ; 192(2): 149, 2020 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-31997011

RESUMO

This paper presents the development, calibration and verification of a two-dimensional model for a Danube reach and its old cutoff meander. The considered meander was at one point separated from the main reach with a levee, which caused a series of unwanted environmental consequences. Aiming to stop the ongoing degradation of the meander, the validated model was engaged to investigate the effects different river works would have on its current state. The considered river works involved dredging in certain parts of the meander, while keeping in mind the negative effects these works can have on the environment, as well as possible widening of the existing opening in the levee. Numerical simulations showed that all the considered scenarios would result in a general increase of velocities, which is important from the aspect of sediment deposition. After a thorough evaluation of the results, it was found that by carefully selecting the locations where dredging should be conducted, no other interference is needed to put an end to the increasingly deteriorating situation in the meander. Computations confirmed that the suggested river works would increase the unit discharge in the entire meander, especially in its upstream part. The redistribution of flow around the island downstream of the levee (that formed during past years as a result of sediment deposition) was also predicted, where the flow would once again favor the left side of the island. This is a more natural path of flow that would aid the flushing of previously deposited sediment in this part of the meander.


Assuntos
Monitoramento Ambiental , Movimentos da Água , Sedimentos Geológicos , Modelos Teóricos , Rios
8.
J Cardiovasc Magn Reson ; 21(1): 12, 2019 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-30786898

RESUMO

BACKGROUND: Quantitative results of cardiovascular magnetic resonance (CMR) image analysis influence clinical decision making. Image analysis is performed based on dedicated software. The manufacturers provide different analysis tools whose algorithms are often unknown. The aim of this study was to evaluate the impact of software on quantification of left ventricular (LV) assessment, 2D flow measurement and T1- and T2-parametric mapping. METHODS: Thirty-one data sets of patients who underwent a CMR Scan on 1.5 T were analyzed using three different software (Circle CVI: cvi42, Siemens Healthineers: Argus, Medis: Qmass/Qflow) by one reader blinded to former results. Cine steady state free precession short axis images were analyzed regarding LV ejection fraction (EF), end-systolic and end-diastolic volume (ESV, EDV) and LV mass. Phase-contrast magnetic resonance images were evaluated for forward stroke volume (SV) and peak velocity (Vmax). Pixel-wise generated native T1- and T2-maps were used to assess T1- and T2-time. Forty-five data sets were evaluated twice (15 per software) for intraobserver analysis. Equivalence was considered if the confidence interval of a paired assessment of two sofware was within a tolerance interval defined by ±1.96 highest standard deviation obtained by intraobserver analysis. RESULTS: For each parameter, thirty data sets could be analyzed with all three software. All three software (A/B, A/C, B/C) were considered equivalent for LV EF, EDV, ESV, mass, 2D flow SV and T2-time. Differences between software were detected in flow measurement for Vmax and in parametric mapping for T1-time. For Vmax, equivalence was given between software A and C and for T1-time equivalence was given between software B and C. CONCLUSION: Software had no impact on quantitative results of LV assessment, T2-time and SV based on 2D flow. In contrast to that, Vmax and T1-time may be influenced by software. CMR reports should contain the name and version of the software applied for image analysis to avoid misinterpretation upon follow-up and research examinations. TRIAL REGISTRATION: ISRCTN12210850 . Registered 14 July 2017, retrospectively registered.


Assuntos
Algoritmos , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Design de Software , Volume Sistólico , Função Ventricular Esquerda , Idoso , Feminino , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
9.
Micromachines (Basel) ; 9(5)2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-30424181

RESUMO

In this paper, micro droplets are generated in a microfluidic focusing contactor and then they move sequentially in a free-flowing mode (no wall contact). For this purpose, two different micro-flow glass devices (hydrophobic and hydrophilic) were used. During the study, the influence of the flow rate of the water phase and the oil phase on the droplet size and size distribution was investigated. Moreover, the influence of the oil phase viscosity on the droplet size was analyzed. It was found that the size and size distribution of the droplets can be controlled simply by the aqueous phase flow rate. Additionally, 2D simulations to determine the droplet size were performed and compared with the experiment.

10.
Magn Reson Med ; 79(4): 1882-1892, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28714282

RESUMO

PURPOSE: To assess the variability of peak flow, mean velocity, stroke volume, and wall shear stress measurements derived from 3D cine phase contrast (4D flow) sequences under different conditions of spatial and temporal resolutions. METHODS: We performed controlled experiments using a thoracic aortic phantom. The phantom was connected to a pulsatile flow pump, which simulated nine physiological conditions. For each condition, 4D flow data were acquired with different spatial and temporal resolutions. The 2D cine phase contrast and 4D flow data with the highest available spatio-temporal resolution were considered as a reference for comparison purposes. RESULTS: When comparing 4D flow acquisitions (spatial and temporal resolution of 2.0 × 2.0 × 2.0 mm3 and 40 ms, respectively) with 2D phase-contrast flow acquisitions, the underestimation of peak flow, mean velocity, and stroke volume were 10.5, 10 and 5%, respectively. However, the calculated wall shear stress showed an underestimation larger than 70% for the former acquisition, with respect to 4D flow, with spatial and temporal resolution of 1.0 × 1.0 × 1.0 mm3 and 20 ms, respectively. CONCLUSIONS: Peak flow, mean velocity, and stroke volume from 4D flow data are more sensitive to changes of temporal than spatial resolution, as opposed to wall shear stress, which is more sensitive to changes in spatial resolution. Magn Reson Med 79:1882-1892, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Aorta Torácica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Diástole , Endotélio Vascular/diagnóstico por imagem , Hemodinâmica , Humanos , Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Microscopia de Contraste de Fase , Imagens de Fantasmas , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Estresse Mecânico , Volume Sistólico , Sístole , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA