Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
J Neurophysiol ; 132(4): 1265-1277, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39258777

RESUMO

The central auditory system encompasses two primary functions: identification and localization. Spatial release from masking (SRM) highlights speech recognition in competing noise and improves the listening experience when a spatial cue is introduced between noise and target speech. This assessment focuses on the integrity of auditory function and holds clinical significance. However, infants or pre-lingual subjects sometimes provide less reliable results. This study investigates the value of cortical auditory evoked potentials (CAEPs) onset and acoustic change complex (ACC) as an objective measurement of SRM. Thirty normal-hearing young adults (11 males) were recruited. We found the spatial separation of signals and noise (±90° symmetrically) resulted in a signal-to-noise ratio (SNR) improvement of 9.00 ± 1.71 dB behaviorally. It significantly enhanced cortical processing at all SNR levels, shortened CAEP latencies, and increased amplitudes, resulting in a greater number of measurable peaks for ACC. SRM showed mild to moderate correlations with the differences between two conditions in CAEP measures. The regression model combining N1'-P2' amplitude at 5 dB SNR (R2 = 0.26), P1 amplitude at 0 dB SNR (R2 = 0.14), and P1 latency at -5 dB SNR (R2 = 0.15), explained 45.3% of the variance in SRM. Our study demonstrates that introducing spatial cues can improve speech perception and enhance central auditory processing in normal-hearing young adults. CAEPs may contribute to predictions about SRM and hold potential for practical application.NEW & NOTEWORTHY The neural encoding of spatial release from masking (SRM) can be observed in normal-hearing young adults. Spatial separation between target and masker improves speech perception in noise and enhances central auditory processing. The behavioral results showed mild-to-moderate correlations with electrophysiological measures, with acoustic change complex (ACC) amplitude being a better indicator than onset components. Cortical auditory evoked potentials (CAEPs) may contribute to predictions about spatial release from masking, especially when behavioral tests are less reliable.


Assuntos
Potenciais Evocados Auditivos , Mascaramento Perceptivo , Percepção da Fala , Humanos , Feminino , Masculino , Mascaramento Perceptivo/fisiologia , Adulto , Potenciais Evocados Auditivos/fisiologia , Adulto Jovem , Percepção da Fala/fisiologia , Córtex Auditivo/fisiologia , Eletroencefalografia , Ruído , Razão Sinal-Ruído
2.
Int J Audiol ; : 1-10, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39162810

RESUMO

OBJECTIVE: We have shown that the acoustic change complex (ACC) can be elicited by changing the horizontal sound location in young individuals. In this study, we aimed to evaluate the application of ACC within the elderly and its relationship with behavioural results. DESIGN: The minimum audible angle (MAA), as well as onset cortical auditory evoked potentials (onset-CAEPs) and ACC elicited by the stimuli of location-change white noise (±45 to ±2 degrees) were recorded. Latencies and amplitudes were analysed using repeated-measures ANOVA. Pearson correlation analysis was conducted to examine the relationship between ACC and MAA. STUDY SAMPLE: Ten older adults with normal hearing (NH) and twenty with presbycusis. RESULTS: The ACC was effectively elicited with angular variations in elderly participants. The onset-CAEP N1 latency, ACC N1'-P2' amplitude, and N1' latency were all associated with the angle shifts, with the N1' latency being the most predictive factor for angle discrimination. The consistency between MAA and ACC made them complementary for the clinical evaluation of sound localisation. CONCLUSIONS: The utilisation of ACC, evoked by location-change sounds, presented a promising clinical objective measure for evaluating sound localisation abilities in the elderly.

3.
Acta Otolaryngol ; 144(7-8): 461-466, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39192827

RESUMO

BACKGROUND: An objective measurement of speech perception would be valuable in hearing-impaired patients who are unable to perform auditory tasks reliably. OBJECTIVES: To investigate the feasibility of cortical auditory evoked potentials (CAEPs) evoked by different spectro-temporal modulation (STM) signals and provide reference for the further exploration of acoustic change complex (ACC) in hearing-impaired patients. METHOD: 29 normal hearing (NH) adults were recruited and stimulated randomly by STM signals at 6 spectral modulation rates: 0, 1, 2, 4, 8, 16 cycles/octave, at each of 4 temporal modulation rates: 0, 2, 4, 8 Hz, to elicit ACC response. RESULTS: The change of spectral modulation rates ≤ 16 cycles/octave at 0 Hz temporal modulation rate had different impacts on latency. 0, 1 cycles/octave, and 4, 8 Hz made a difference to the P2-N1 amplitude easily. 8, 16 cycles/octave were more unstable in rejection rate. No significant difference existed in waveform repetition rate among different STM rates. No significant interaction effect existed in spectral and temporal modulation. CONCLUSIONS: STM as a stimulus signal to induce ACC response had its feasibility. 2 cycles/octave at spectral modulation rate and 2 Hz at temporal modulation rate had better stability and waveform repeatability in NH adults.


Assuntos
Potenciais Evocados Auditivos , Estudos de Viabilidade , Humanos , Potenciais Evocados Auditivos/fisiologia , Adulto , Masculino , Feminino , Adulto Jovem , Estimulação Acústica/métodos , Percepção da Fala/fisiologia , Córtex Auditivo/fisiologia
4.
Hear Res ; 451: 109090, 2024 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-39047579

RESUMO

OBJECTIVE: The acoustic change complex (ACC) is a cortical auditory evoked potential (CAEP) and can be elicited by a change in an otherwise continuous sound. The ACC has been highlighted as a promising tool in the assessment of sound and speech discrimination capacity, and particularly for difficult-to-test populations such as infants with hearing loss, due to the objective nature of ACC measurements. Indeed, there is a pressing need to develop further means to accurately and thoroughly establish the hearing status of children with hearing loss, to help guide hearing interventions in a timely manner. Despite the potential of the ACC method, ACC measurements remain relatively rare in a standard clinical settings. The objective of this study was to perform an up-to-date systematic review on ACC measurements in children, to provide greater clarity and consensus on the possible methodologies, applications, and performance of this technique, and to facilitate its uptake in relevant clinical settings. DESIGN: Original peer-reviewed articles conducting ACC measurements in children (< 18 years). Data were extracted and summarised for: (1) participant characteristics; (2) ACC methods and auditory stimuli; (3) information related to the performance of the ACC technique; (4) ACC measurement outcomes, advantages, and challenges. The systematic review was conducted using PRISMA guidelines for reporting and the methodological quality of included articles was assessed. RESULTS: A total of 28 studies were identified (9 infant studies). Review results show that ACC responses can be measured in infants (from < 3 months), and there is evidence of age-dependency, including increased robustness of the ACC response with increasing childhood age. Clinical applications include the measurement of the neural capacity for speech and non-speech sound discrimination in children with hearing loss, auditory neuropathy spectrum disorder (ANSD) and central auditory processing disorder (CAPD). Additionally, ACCs can be recorded in children with hearing aids, auditory brainstem implants, and cochlear implants, and ACC results may guide hearing intervention/rehabilitation strategies. The review identified that the time taken to perform ACC measurements was often lengthy; the development of more efficient ACC test procedures for children would be beneficial. Comparisons between objective ACC measurements and behavioural measures of sound discrimination showed significant correlations for some, but not all, included studies. CONCLUSIONS: ACC measurements of the neural capacity to discriminate between speech and non-speech sounds are feasible in infants and children, and a wide range of possible clinical applications exist, although more time-efficient procedures would be advantageous for clinical uptake. A consideration of age and maturational effects is recommended, and further research is required to investigate the relationship between objective ACC measures and behavioural measures of sound and speech perception for effective clinical implementation.


Assuntos
Estimulação Acústica , Percepção Auditiva , Potenciais Evocados Auditivos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Fatores Etários , Córtex Auditivo/fisiologia , Córtex Auditivo/fisiopatologia , Vias Auditivas/fisiopatologia , Vias Auditivas/fisiologia , Audição , Perda Auditiva/fisiopatologia , Perda Auditiva/diagnóstico , Perda Auditiva/reabilitação , Pessoas com Deficiência Auditiva/psicologia , Pessoas com Deficiência Auditiva/reabilitação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Testes de Discriminação da Fala
5.
Hear Res ; 448: 109020, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38763034

RESUMO

Combining cochlear implants with binaural acoustic hearing via preserved hearing in the implanted ear(s) is commonly referred to as combined electric and acoustic stimulation (EAS). EAS fittings can provide patients with significant benefit for speech recognition in complex noise, perceived listening difficulty, and horizontal-plane localization as compared to traditional bimodal hearing conditions with contralateral and monaural acoustic hearing. However, EAS benefit varies across patients and the degree of benefit is not reliably related to the underlying audiogram. Previous research has indicated that EAS benefit for speech recognition in complex listening scenarios and localization is significantly correlated with the patients' binaural cue sensitivity, namely interaural time differences (ITD). In the context of pure tones, interaural phase differences (IPD) and ITD can be understood as two perspectives on the same phenomenon. Through simple mathematical conversion, one can be transformed into the other, illustrating their inherent interrelation for spatial hearing abilities. However, assessing binaural cue sensitivity is not part of a clinical assessment battery as psychophysical tasks are time consuming, require training to achieve performance asymptote, and specialized programming and software all of which render this clinically unfeasible. In this study, we investigated the possibility of using an objective measure of binaural cue sensitivity by the acoustic change complex (ACC) via imposition of an IPD of varying degrees at stimulus midpoint. Ten adult listeners with normal hearing were assessed on tasks of behavioral and objective binaural cue sensitivity for carrier frequencies of 250 and 1000 Hz. Results suggest that 1) ACC amplitude increases with IPD; 2) ACC-based IPD sensitivity for 250 Hz is significantly correlated with behavioral ITD sensitivity; 3) Participants were more sensitive to IPDs at 250 Hz as compared to 1000 Hz. Thus, this objective measure of IPD sensitivity may hold clinical application for pre- and post-operative assessment for individuals meeting candidacy indications for cochlear implantation with low-frequency acoustic hearing preservation as this relatively quick and objective measure may provide clinicians with information identifying patients most likely to derive benefit from EAS technology.


Assuntos
Estimulação Acústica , Limiar Auditivo , Implante Coclear , Implantes Cocleares , Sinais (Psicologia) , Localização de Som , Percepção da Fala , Humanos , Feminino , Masculino , Implante Coclear/instrumentação , Adulto , Pessoa de Meia-Idade , Estimulação Elétrica , Audiometria de Tons Puros , Pessoas com Deficiência Auditiva/psicologia , Pessoas com Deficiência Auditiva/reabilitação , Fatores de Tempo , Idoso , Ruído/efeitos adversos , Mascaramento Perceptivo , Adulto Jovem , Audição , Psicoacústica
6.
Front Hum Neurosci ; 18: 1342931, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681742

RESUMO

Objectives: The auditory spatial processing abilities mature throughout childhood and degenerate in older adults. This study aimed to compare the differences in onset cortical auditory evoked potentials (CAEPs) and location-evoked acoustic change complex (ACC) responses among children, adults, and the elderly and to investigate the impact of aging and development on ACC responses. Design: One hundred and seventeen people were recruited in the study, including 57 typically-developed children, 30 adults, and 30 elderlies. The onset-CAEP evoked by white noise and ACC by sequential changes in azimuths were recorded. Latencies and amplitudes as a function of azimuths were analyzed using the analysis of variance, Pearson correlation analysis, and multiple linear regression model. Results: The ACC N1'-P2' amplitudes and latencies in adults, P1'-N1' amplitudes in children, and N1' amplitudes and latencies in the elderly were correlated with angles of shifts. The N1'-P2' and P2' amplitudes decreased in the elderly compared to adults. In Children, the ACC P1'-N1' responses gradually differentiated into the P1'-N1'-P2' complex. Multiple regression analysis showed that N1'-P2' amplitudes (R2 = 0.33) and P2' latencies (R2 = 0.18) were the two most variable predictors in adults, while in the elderly, N1' latencies (R2 = 0.26) explained most variances. Although the amplitudes of onset-CAEP differed at some angles, it could not predict angle changes as effectively as ACC responses. Conclusion: The location-evoked ACC responses varied among children, adults, and the elderly. The N1'-P2' amplitudes and P2' latencies in adults and N1' latencies in the elderly explained most variances of changes in spatial position. The differentiation of the N1' waveform was observed in children. Further research should be conducted across all age groups, along with behavioral assessments, to confirm the relationship between aging and immaturity in objective ACC responses and poorer subjective spatial performance. Significance: ACCs evoked by location changes were assessed in adults, children, and the elderly to explore the impact of aging and development on these differences.

7.
Diagn Progn Res ; 8(1): 1, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263270

RESUMO

BACKGROUND: Speech perception tests are essential to measure the functional use of hearing and to determine the effectiveness of hearing aids and implantable auditory devices. However, these language-based tests require active participation and are influenced by linguistic and neurocognitive skills limiting their use in patients with insufficient language proficiency, cognitive impairment, or in children. We recently developed a non-attentive and objective speech perception prediction model: the Acoustic Change Complex (ACC) prediction model. The ACC prediction model uses electroencephalography to measure alterations in cortical auditory activity caused by frequency changes. The aim is to validate this model in a large-scale external validation study in adult patients with varying degrees of sensorineural hearing loss (SNHL) to confirm the high predictive value of the ACC model and to assess its test-retest reliability. METHODS: A total of 80 participants, aged 18-65 years, will be enrolled in the study. The categories of severity of hearing loss will be used as a blocking factor to establish an equal distribution of patients with various degrees of sensorineural hearing loss. During the first visit, pure tone audiometry, speech in noise tests, a phoneme discrimination test, and the first ACC measurement will be performed. During the second visit (after 1-4 weeks), the same ACC measurement will be performed to assess the test-retest reliability. The acoustic change stimuli for ACC measurements consist of a reference tone with a base frequency of 1000, 2000, or 4000 Hz with a duration of 3000 ms, gliding to a 300-ms target tone with a frequency that is 12% higher than the base frequency. The primary outcome measures are (1) the level of agreement between the predicted speech reception threshold (SRT) and the behavioral SRT, and (2) the level of agreement between the SRT calculated by the first ACC measurement and the SRT of the second ACC measurement. Level of agreement will be assessed with Bland-Altman plots. DISCUSSION: Previous studies by our group have shown the high predictive value of the ACC model. The successful validation of this model as an effective and reliable biomarker of speech perception will directly benefit the general population, as it will increase the accuracy of hearing evaluations and improve access to adequate hearing rehabilitation.

8.
Clin Neurophysiol ; 149: 121-132, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36963143

RESUMO

OBJECTIVE: This study examined (1) the utility of a clinical system to record acoustic change complex (ACC, an event-related potential recorded by electroencephalography) for assessing speech discrimination in infants, and (2) the relationship between ACC and functional performance in real life. METHODS: Participants included 115 infants (43 normal-hearing, 72 hearing-impaired), aged 3-12 months. ACCs were recorded using [szs], [uiu], and a spectral rippled noise high-pass filtered at 2 kHz as stimuli. Assessments were conducted at age 3-6 months and at 7-12 months. Functional performance was evaluated using a parent-report questionnaire, and correlations with ACC were examined. RESULTS: The rates of onset and ACC responses of normal-hearing infants were not significantly different from those of aided infants with mild or moderate hearing loss but were significantly higher than those with severe loss. On average, response rates measured at 3-6 months were not significantly different from those at 7-12 months. Higher rates of ACC responses were significantly associated with better functional performance. CONCLUSIONS: ACCs demonstrated auditory capacity for discrimination in infants by 3-6 months. This capacity was positively related to real-life functional performance. SIGNIFICANCE: ACCs can be used to evaluate the effectiveness of amplification and monitor development in aided hearing-impaired infants.


Assuntos
Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Humanos , Lactente , Percepção da Fala/fisiologia , Perda Auditiva/diagnóstico , Potenciais Evocados , Testes Auditivos , Audição , Estimulação Acústica
9.
Audiol Neurootol ; 28(3): 151-157, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36450234

RESUMO

INTRODUCTION: Expanding cochlear implant (CI) candidacy criteria and advances in electrode arrays and soft surgical techniques have increased the number of CI recipients who have residual low-frequency hearing. Objective measures such as obligatory cortical auditory-evoked potentials (CAEPs) may help clinicians make more tailored recommendations to recipients regarding optimal listening mode. As a step toward this goal, this study investigated how CAEPs measured from hybrid CI users differ in two listening modes: acoustic alone (A-alone) versus acoustic plus electric (A + E). METHODS: Eight successful hybrid CI users participated in this study. Two CAEPs, the P1-N1-P2 and the acoustic change complex (ACC), were measured simultaneously in response to the onset and change of a series of different and spectrally complex acoustic signals, in each of the two listening modes (A-alone and A + E). We examined the effects of listening mode and stimulus type on the onset and ACC N1-P2 amplitudes and peak latencies. RESULTS: ACC amplitudes in hybrid CI users significantly differed as a function of listening mode and stimulus type. ACC responses in A + E were larger than those in the A-alone mode. This was most evident for stimuli involving a change from low to high frequency. CONCLUSIONS: Results of this study showed that the ACC varies as a function of listening mode and stimulus type. This finding suggests that the ACC can be used as a physiologic, objective measure of the benefit of hybrid CIs, potentially supporting clinicians in making clinical recommendations on individualized listening mode, or to document subjective preference for a given listening mode. Further research into this potential clinical application in a range of hybrid recipients and/or long electrode users who have residual low-frequency hearing is warranted.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Potenciais Evocados Auditivos/fisiologia , Audição , Acústica , Estimulação Acústica , Percepção da Fala/fisiologia
10.
Front Psychol ; 13: 935475, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992450

RESUMO

Word in noise identification is facilitated by acoustic differences between target and competing sounds and temporal separation between the onset of the masker and that of the target. Younger and older adults are able to take advantage of onset delay when the masker is dissimilar (Noise) to the target word, but only younger adults are able to do so when the masker is similar (Babble). We examined the neural underpinning of this age difference using cortical evoked responses to words masked by either Babble or Noise when the masker preceded the target word by 100 or 600 ms in younger and older adults, after adjusting the signal-to-noise ratios (SNRs) to equate behavioural performance across age groups and conditions. For the 100 ms onset delay, the word in noise elicited an acoustic change complex (ACC) response that was comparable in younger and older adults. For the 600 ms onset delay, the ACC was modulated by both masker type and age. In older adults, the ACC to a word in babble was not affected by the increase in onset delay whereas younger adults showed a benefit from longer delays. Hence, the age difference in sensitivity to temporal delay is indexed by early activity in the auditory cortex. These results are consistent with the hypothesis that an increase in onset delay improves stream segregation in younger adults in both noise and babble, but only in noise for older adults and that this change in stream segregation is evident in early cortical processes.

11.
Int J Pediatr Otorhinolaryngol ; 161: 111271, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35988371

RESUMO

OBJECTIVE: To validate the clinical use of Acoustic Change Complex (ACC) as an objective tool in children who use hearing Aids and explore how far ACC response parameters could be correlated to behavioral tests. METHOD: Sixty Arabic speaking children, using binaural Hearing Aids (H.As), participated in the present study. Their age ranged from 6 to 12 years. Evaluation of Hearing aid device performance was performed through questionnaire, speech in noise tests and aided/unaided ACC recordings. Two stimuli '' vowel/o/with SNR (0 &+8) ''were developed and standardized to elicit ACC response. The replicated ACC waveforms were collected and analyzed and the aided ACC responses were compared with unaided ACC and correlated to behavioral tests. RESULTS: The ACC percent identification in children using H.As using vowel/o/with SNR (+8 & 0) stimuli was 75% and 45% respectively in aided condition, the percent decreased to 40% and 15% in unaided condition. Speech in noise stimuli showed significant difference of ACC-N1 latency between the aided and unaided groups being longer in the unaided condition. The correlations between behavioral tests and ACC response (latency and amplitude) were irrelevant. CONCLUSIONS: Hearing-impaired subjects can process speech stimulus at the level of the auditory cortex, and in a more effective manner when they used their H.As. ACC can be used as an objective measure for selective auditory attention ability using vowel-in-noise. However, it couldn't replace Behavioral measures.


Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial , Percepção da Fala , Acústica , Criança , Perda Auditiva Neurossensorial/reabilitação , Humanos , Ruído/efeitos adversos , Fala , Percepção da Fala/fisiologia
12.
Int J Pediatr Otorhinolaryngol ; 160: 111217, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35816970

RESUMO

OBJECTIVE: To validate the clinical use of acoustic change complex (ACC) as an objective outcome measure of auditory training in Egyptian cochlear implant (CI) children and explore how far electrophysiological measures could be correlated to behavioral measures in assessing training outcome. Also to explore the efficacy of computer-based auditory training programs (CBATP) in the rehabilitation process of CI children. METHODS: Sixty Arabic speaking children participated in the present study. Forty children using monaural CI device served as study group (20 children in subgroup A and 20 children in subgroup B). Both subgroups received traditional speech therapy sessions, additionally subgroup (A) children received computer-based auditory training program (CBATP) at home for three months. Their age ranged from 8 to 17 years. 20 age and sex-matched normal hearing children served as control group as a standardization for the stimuli used to elicit ACC. The study group children were subjected to detailed history taking, parent reported questionnaire (MAIS, Arabic version), aided sound field evaluation, psychophysical evaluation using auditory fusion test (AFT), speech perception testing according to language age, ACC in response to gaps in 1000 Hz tones and language evaluation. This work-up was repeated after 3&6 months for both study subgroups. RESULTS: Children of study subgroup (A) showed improvement of auditory fusion test (AFT) thresholds at 3 & 6 months post-training follow up. As regards acoustic change complex (ACC), it can be detected in 85% of subgroup (A) children, 85% of subgroup (B) children and 100% of control group children. Lower ACC gap detection thresholds were obtained only after 3 months in subgroup (A), while after 6 months in subgroup (B). There were statistically significant differences between initial assessment and 3 & 6 months follow up as regards ACC P1 and N2 latencies and amplitudes in both study subgroups, however in subgroup (A), ACC P1 amplitude at 6 months post-training was significantly larger than values of 3 months follow up. There was highly significant correlation between thresholds of AFT and ACC gap detection threshold. CONCLUSIONS: ACC can be used as a reliable tool for evaluating auditory training outcome in CI children. ACC gap detection threshold can predict psychophysical temporal resolution after auditory training in difficult to test population. CBATP is an easy and accessible method which may be effective in improving CI outcome.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adolescente , Criança , Implante Coclear/métodos , Computadores , Potenciais Evocados Auditivos/fisiologia , Humanos , Avaliação de Resultados em Cuidados de Saúde , Percepção da Fala/fisiologia
13.
Front Neurosci ; 16: 904724, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35757528

RESUMO

Previous studies, using modulation stimuli, on the relative effects of frequency resolution and time resolution on CI users' speech perception failed to reach a consistent conclusion. In this study, frequency change detection and temporal gap detection were used to investigate the frequency resolution and time resolution of CI users, respectively. Psychophysical and neurophysiological methods were used to simultaneously investigate the effects of frequency and time resolution on speech perception in post-lingual cochlear implant (CI) users. We investigated the effects of psychophysical results [frequency change detection threshold (FCDT), gap detection threshold (GDT)], and acoustic change complex (ACC) responses (evoked threshold, latency, or amplitude of ACC induced by frequency change or temporal gap) on speech perception [recognition rate of monosyllabic words, disyllabic words, sentences in quiet, and sentence recognition threshold (SRT) in noise]. Thirty-one adult post-lingual CI users of Mandarin Chinese were enrolled in the study. The stimuli used to induce ACCs to frequency changes were 800-ms pure tones (fundamental frequency was 1,000 Hz); the frequency change occurred at the midpoint of the tones, with six percentages of frequency changes (0, 2, 5, 10, 20, and 50%). Temporal silences with different durations (0, 5, 10, 20, 50, and 100 ms) were inserted in the middle of the 800-ms white noise to induce ACCs evoked by temporal gaps. The FCDT and GDT were obtained by two 2-alternative forced-choice procedures. The results showed no significant correlation between the CI hearing threshold and speech perception in the study participants. In the multiple regression analysis of the influence of simultaneous psychophysical measures and ACC responses on speech perception, GDT significantly predicted every speech perception index, and the ACC amplitude evoked by the temporal gap significantly predicted the recognition of disyllabic words in quiet and SRT in noise. We conclude that when the ability to detect frequency changes and the temporal gap is considered simultaneously, the ability to detect frequency changes may have no significant effect on speech perception, but the ability to detect temporal gaps could significantly predict speech perception.

14.
Front Neurosci ; 16: 908989, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35733932

RESUMO

Acoustic change complex (ACC) is a cortical auditory-evoked potential induced by a change of continuous sound stimulation. This study aimed to explore: (1) whether the change of horizontal sound location can elicit ACC; (2) the relationship between the change of sound location and the amplitude or latency of ACC; (3) the relationship between the behavioral measure of localization, minimum audible angle (MAA), and ACC. A total of 36 normal-hearing adults participated in this study. A 180° horizontal arc-shaped bracket with a 1.2 m radius was set in a sound field where participants sat at the center. MAA was measured in a two-alternative forced-choice setting. The objective electroencephalography recording of ACC was conducted with the location changed at four sets of positions, ±45°, ±15°, ±5°, and ±2°. The test stimulus was a 125-6,000 Hz broadband noise of 1 s at 60 ± 2 dB SPL with a 2 s interval. The N1'-P2' amplitudes, N1' latencies, and P2' latencies of ACC under four positions were evaluated. The influence of electrode sites and the direction of sound position change on ACC waveform was analyzed with analysis of variance. Results suggested that (1) ACC can be elicited successfully by changing the horizontal sound location position. The elicitation rate of ACC increased with the increase of location change. (2) N1'-P2' amplitude increased and N1' and P2' latencies decreased as the change of sound location increased. The effects of test angles on N1'-P2' amplitude [F(1.91,238.1) = 97.172, p < 0.001], N1' latency [F(1.78,221.90) = 96.96, p < 0.001], and P2' latency [F(1.87,233.11) = 79.97, p < 0.001] showed a statistical significance. (3) The direction of sound location change had no significant effect on any of the ACC peak amplitudes or latencies. (4) Sound location discrimination threshold by the ACC test (97.0% elicitation rate at ±5°) was higher than MAA threshold (2.08 ± 0.5°). The current study results show that though the ACC thresholds are higher than the behavioral thresholds on MAA task, ACC can be used as an objective method to evaluate sound localization ability. This article discusses the implications of this research for clinical practice and evaluation of localization skills, especially for children.

15.
J Assoc Res Otolaryngol ; 23(4): 491-512, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35668206

RESUMO

Cochlear implant (CI) users show limited sensitivity to the temporal pitch conveyed by electric stimulation, contributing to impaired perception of music and of speech in noise. Neurophysiological studies in cats suggest that this limitation is due, in part, to poor transmission of the temporal fine structure (TFS) by the brainstem pathways that are activated by electrical cochlear stimulation. It remains unknown, however, how that neural limit might influence perception in the same animal model. For that reason, we developed non-invasive psychophysical and electrophysiological measures of temporal (i.e., non-spectral) pitch processing in the cat. Normal-hearing (NH) cats were presented with acoustic pulse trains consisting of band-limited harmonic complexes that simulated CI stimulation of the basal cochlea while removing cochlear place-of-excitation cues. In the psychophysical procedure, trained cats detected changes from a base pulse rate to a higher pulse rate. In the scalp-recording procedure, the cortical-evoked acoustic change complex (ACC) and brainstem-generated frequency following response (FFR) were recorded simultaneously in sedated cats for pulse trains that alternated between the base and higher rates. The range of perceptual sensitivity to temporal pitch broadly resembled that of humans but was shifted to somewhat higher rates. The ACC largely paralleled these perceptual patterns, validating its use as an objective measure of temporal pitch sensitivity. The phase-locked FFR, in contrast, showed strong brainstem encoding for all tested pulse rates. These measures demonstrate the cat's perceptual sensitivity to pitch in the absence of cochlear-place cues and may be valuable for evaluating neural mechanisms of temporal pitch perception in the feline animal model of stimulation by a CI or novel auditory prostheses.


Assuntos
Implante Coclear , Implantes Cocleares , Estimulação Acústica/métodos , Animais , Gatos , Humanos , Percepção da Altura Sonora/fisiologia , Psicofísica , Couro Cabeludo
16.
Hear Res ; 420: 108508, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35477512

RESUMO

Accurate and objective assessment of higher order auditory processing is challenging and mainly relies on evaluations that require a subjects' active participation in tests such as frequency discrimination or speech perception in noise. This study investigates the value of cortical auditory evoked potentials (CAEPs) evoked in response to auditory change stimuli, known as acoustic change complexes (ACCs), as an objective measurement of auditory performance in hearing impairment. Secondary objectives were to assess the effect of hearing loss and non-professional musical experience on the ACC, and compare the ACC to the 'conventional' CAEP evoked in response to stimulus onset. In 24 normal-hearing subjects, consisting of 12 musicians and 12 non-musicians, and 13 age-matched hearing-impaired subjects ACCs were recorded in response to 12% frequency increases at four base frequencies (0.5, 1, 2 and 4 kHz). ACC amplitudes and latencies were compared to frequency discrimination thresholds at each base frequency, and to speech perception in noise. Frequency discrimination and speech perception in noise were significantly better for larger ACC N1-P2 amplitudes and shorter N1 latencies, whereas both frequency discrimination and speech perception did not correlate with onset CAEP amplitude or latency. Multiple regression analysis for prediction of speech perception in noise revealed that the strongest model was obtained by averaging over three frequencies (1, 2 and 4 kHz) with two significant predictors: hearing loss (R2 = 0.52) and ACC latency (R2 = 0.35). Thus, explaining 87% of the variance, this model indicates that subjects with longer ACC latencies have worse speech perception in noise than subjects with comparable hearing thresholds and shorter ACC latencies. If hearing loss was removed from this model, the combination of ACC amplitude and latency over those three frequencies explained 74% of the total variance in speech perception in noise. There were no differences in frequency discrimination, speech perception, CAEP, or ACC between recreational musicians and non-musicians. We conclude that the objective ACC N1 latency is a good predictor of speech perception in noise. When confirmed in validation studies with larger numbers of subjects, it can aid clinicians in their evaluation of auditory performance and higher order processing, in particular when behavioral testing is unreliable.


Assuntos
Surdez , Perda Auditiva , Percepção da Fala , Estimulação Acústica , Potenciais Evocados Auditivos/fisiologia , Audição/fisiologia , Humanos , Ruído/efeitos adversos , Percepção da Fala/fisiologia
17.
Front Hum Neurosci ; 15: 757254, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34744668

RESUMO

One of the biggest challenges that face cochlear implant (CI) users is the highly variable hearing outcomes of implantation across patients. Since speech perception requires the detection of various dynamic changes in acoustic features (e.g., frequency, intensity, timing) in speech sounds, it is critical to examine the ability to detect the within-stimulus acoustic changes in CI users. The primary objective of this study was to examine the auditory event-related potential (ERP) evoked by the within-stimulus frequency changes (F-changes), one type of the acoustic change complex (ACC), in adult CI users, and its correlation to speech outcomes. Twenty-one adult CI users (29 individual CI ears) were tested with psychoacoustic frequency change detection tasks, speech tests including the Consonant-Nucleus-Consonant (CNC) word recognition, Arizona Biomedical Sentence Recognition in quiet and noise (AzBio-Q and AzBio-N), and the Digit-in-Noise (DIN) tests, and electroencephalographic (EEG) recordings. The stimuli for the psychoacoustic tests and EEG recordings were pure tones at three different base frequencies (0.25, 1, and 4 kHz) that contained a F-change at the midpoint of the tone. Results showed that the frequency change detection threshold (FCDT), ACC N1' latency, and P2' latency did not differ across frequencies (p > 0.05). ACC N1'-P2 amplitude was significantly larger for 0.25 kHz than for other base frequencies (p < 0.05). The mean N1' latency across three base frequencies was negatively correlated with CNC word recognition (r = -0.40, p < 0.05) and CNC phoneme (r = -0.40, p < 0.05), and positively correlated with mean FCDT (r = 0.46, p < 0.05). The P2' latency was positively correlated with DIN (r = 0.47, p < 0.05) and mean FCDT (r = 0.47, p < 0.05). There was no statistically significant correlation between N1'-P2' amplitude and speech outcomes (all ps > 0.05). Results of this study indicated that variability in CI speech outcomes assessed with the CNC, AzBio-Q, and DIN tests can be partially explained (approximately 16-21%) by the variability of cortical sensory encoding of F-changes reflected by the ACC.

18.
Hear Res ; 401: 108154, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33387905

RESUMO

Frequency discrimination ability varies within the normal hearing population, partially explained by factors such as musical training and age, and it deteriorates with hearing loss. Frequency discrimination, while essential for several auditory tasks, is not routinely measured in clinical setting. This study investigates cortical auditory evoked potentials in response to frequency changes, known as acoustic change complexes (ACCs), and explores their value as a clinically applicable objective measurement of frequency discrimination. In 12 normal-hearing and 13 age-matched hearing-impaired subjects, ACC thresholds were recorded at 4 base frequencies (0.5, 1, 2, 4 kHz) and compared to psychophysically assessed frequency discrimination thresholds. ACC thresholds had a moderate to strong correlation to psychophysical frequency discrimination thresholds. In addition, ACC thresholds increased with hearing loss and higher ACC thresholds were associated with poorer speech perception in noise. The ACC threshold in response to a frequency change therefore holds promise as an objective clinical measurement in hearing impairment, indicative of frequency discrimination ability and related to speech perception. However, recordings as conducted in the current study are relatively time consuming. The current clinical application would be most relevant in cases where behavioral testing is unreliable.


Assuntos
Perda Auditiva , Percepção da Fala , Estimulação Acústica , Limiar Auditivo , Potenciais Evocados Auditivos , Audição , Perda Auditiva/diagnóstico , Humanos , Ruído
19.
Eur Arch Otorhinolaryngol ; 278(10): 3673-3681, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33052460

RESUMO

INTRODUCTION: Acoustic change complex (ACC) is an important tool to investigate the encoding of the acoustic property of speech signals in various populations. However, there is a limited number of research papers that have explored the usefulness of ACC as a tool to study the neural encoding of consonant-vowel (CV) transition in children with central auditory processing disorder (CAPD). Thus, the present study aims to investigate the utility of ACC as an objective tool to study the neural representation of consonant-vowel (CV) transition in children with CAPD. METHODS: Twenty children diagnosed having CAPD and 20 normal counterparts in the age range of 8-14 years were the participants. The ACC was acquired using naturally produced CV syllable /sa/ with a duration of 380 ms. RESULTS: Latency of N1' and P2' was found to be prolonged in children with CAPD compared to normal counterparts, whereas the amplitude of N1' and P2' did not show any significant difference. Scalp topography showed significantly different activation patterns for children with and without CAPD. CONCLUSION: Prolonged latencies of ACC indicated poor encoding of CV transition in children with CAPD. The difference in scalp topography might be because of the involvement of additional brain areas for the neural discrimination task in children with CAPD.


Assuntos
Transtornos do Desenvolvimento da Linguagem , Percepção da Fala , Estimulação Acústica , Adolescente , Criança , Potenciais Evocados Auditivos , Humanos , Fala
20.
Int J Audiol ; 60(11): 875-884, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33345686

RESUMO

OBJECTIVE: Multiple studies have demonstrated binaural hearing deficits in the aging and those with hearing loss. Consequently, there is great interest in developing efficient clinical tests of binaural hearing acuity to improve diagnostic assessments and to assist clinicians when fitting binaural hearing aids and/or cochlear implants. DESIGN: Two cortical measures of interaural phase difference sensitivity, the acoustic change complex (ACC) and interaural phase modulation following response (IPM-FR), were compared on three metrics using five different stimulus interaural phase differences (IPDs; 0°, ±22.5°, ±45°, ±67.5° and ±90°). These metrics were scalp topography, time-to-detect, and input-output characteristics. STUDY SAMPLE: Ten young, normal-hearing listeners. RESULTS: Scalp topography qualitatively differed between ACC and IPM-FR. The IPM-FR demonstrated better time-to-detect performance on smaller (±22.5° and ±45°) but not larger (67.5°, and ±90°) IPDs. Input-output characteristics of each response were similar. CONCLUSIONS: The IPM-FR may be a faster and more efficient tool for assessing neural sensitivity to subtle IPD changes. However, the ACC may be useful for research or clinical questions concerned with the topographic representation of binaural cues.


Assuntos
Implante Coclear , Implantes Cocleares , Estimulação Acústica , Percepção Auditiva , Audição , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA