Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Clocks Sleep ; 6(3): 338-358, 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39189191

RESUMO

Aircraft pilots face a high mental workload (MW) under environmental constraints induced by high altitude and sometimes sleep restriction (SR). Our aim was to assess the combined effects of hypoxia and sleep restriction on cognitive and physiological responses to different MW levels using the Multi-Attribute Test Battery (MATB)-II with an additional auditory Oddball-like task. Seventeen healthy subjects were subjected in random order to three 12-min periods of increased MW level (low, medium, and high): sleep restriction (SR, <3 h of total sleep time (TST)) vs. habitual sleep (HS, >6 h TST), hypoxia (HY, 2 h, FIO2 = 13.6%, ~3500 m vs. normoxia, NO, FIO2 = 21%). Following each MW level, participants completed the NASA-TLX subjective MW scale. Increasing MW decreases performance on the MATB-II Tracking task (p = 0.001, MW difficulty main effect) and increases NASA-TLX (p = 0.001). In the combined HY/SR condition, MATB-II performance was lower, and the NASA-TLX score was higher compared with the NO/HS condition, while no effect of hypoxia alone was observed. In the accuracy of the auditory task, there is a significant interaction between hypoxia and MW difficulty (F(2-176) = 3.14, p = 0.04), with lower values at high MW under hypoxic conditions. Breathing rate, pupil size, and amplitude of pupil dilation response (PDR) to auditory stimuli are associated with increased MW. These parameters are the best predictors of increased MW, independently of physiological constraints. Adding ECG, SpO2, or electrodermal conductance does not improve model performance. In conclusion, hypoxia and sleep restriction have an additive effect on MW. Physiological and electrophysiological responses must be taken into account when designing a MW predictive model and cross-validation.

2.
Sensors (Basel) ; 24(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39065897

RESUMO

This paper introduces and evaluates an innovative sensor for unobtrusive in-car respiration monitoring, mounted on the backrest of the driver's seat. The sensor seamlessly integrates into the vehicle, measuring breathing rates continuously without requiring active participation from the driver. The paper proves the feasibility of unobtrusive in-car measurements over long periods of time. Operation of the sensor was investigated over 12 participants sitting in the driver seat. A total of 107 min of driving in diverse conditions with overall coverage rate of 84.45% underscores the sensor potential to reliably capture physiological changes in breathing rate for fatigue and stress detection.


Assuntos
Taxa Respiratória , Humanos , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Taxa Respiratória/fisiologia , Masculino , Condução de Veículo , Adulto , Respiração , Feminino , Automóveis
3.
J Med Internet Res ; 26: e51120, 2024 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-39083770

RESUMO

BACKGROUND: Rapid development and implementation of vaccines constituted a crucial step in containing the COVID-19 pandemic. A comprehensive understanding of physiological responses to these vaccines is important to build trust in medicine. OBJECTIVE: This study aims to investigate temporal dynamics before and after COVID-19 vaccination in 4 physiological parameters as well as the duration of menstrual cycle phases. METHODS: In a prospective trial, 17,825 adults in the Netherlands wore a medical device on their wrist for up to 9 months. The device recorded their physiological signals and synchronized with a complementary smartphone app. By means of multilevel quadratic regression, we examined changes in wearable-recorded breathing rate, wrist skin temperature, heart rate, heart rate variability, and objectively assessed the duration of menstrual cycle phases in menstruating participants to assess the effects of COVID-19 vaccination. RESULTS: The recorded physiological signals demonstrated short-term increases in breathing rate and heart rate after COVID-19 vaccination followed by a prompt rebound to baseline levels likely reflecting biological mechanisms accompanying the immune response to vaccination. No sex differences were evident in the measured physiological responses. In menstruating participants, we found a 0.8% decrease in the duration of the menstrual phase following vaccination. CONCLUSIONS: The observed short-term changes suggest that COVID-19 vaccines are not associated with long-term biophysical issues. Taken together, our work provides valuable insights into continuous fluctuations of physiological responses to vaccination and highlights the importance of digital solutions in health care. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1186/s13063-021-05241-5.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Estudos Cross-Over , Frequência Cardíaca , Humanos , Feminino , Vacinas contra COVID-19/administração & dosagem , Masculino , Adulto , Estudos Prospectivos , COVID-19/prevenção & controle , Método Simples-Cego , Países Baixos , Taxa Respiratória , Ciclo Menstrual , SARS-CoV-2/imunologia , Temperatura Cutânea , Vacinação , Pessoa de Meia-Idade , Adulto Jovem
4.
Sensors (Basel) ; 24(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38894339

RESUMO

Vital sign monitoring is dominated by precise but costly contact-based sensors. Contactless devices such as radars provide a promising alternative. In this article, the effects of lateral radar positions on breathing and heartbeat extraction are evaluated based on a sleep study. A lateral radar position is a radar placement from which multiple human body zones are mapped onto different radar range sections. These body zones can be used to extract breathing and heartbeat motions independently from one another via these different range sections. Radars were positioned above the bed as a conventional approach and on a bedside table as well as at the foot end of the bed as lateral positions. These positions were evaluated based on six nights of sleep collected from healthy volunteers with polysomnography (PSG) as a reference system. For breathing extraction, comparable results were observed for all three radar positions. For heartbeat extraction, a higher level of agreement between the radar foot end position and the PSG was found. An example of the distinction between thoracic and abdominal breathing using a lateral radar position is shown. Lateral radar positions could lead to a more detailed analysis of movements along the body, with the potential for diagnostic applications.


Assuntos
Frequência Cardíaca , Radar , Respiração , Sinais Vitais , Humanos , Sinais Vitais/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Frequência Cardíaca/fisiologia , Adulto , Masculino , Polissonografia/métodos , Feminino
5.
Eur J Appl Physiol ; 124(10): 2881-2891, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38703192

RESUMO

PURPOSE: Moderate-intensity aerobic exercise is safe and beneficial in atrial fibrillation (AF) and coronary heart disease (CHD). Irregular or rapid heart rates (HR) in AF and other heart conditions create a challenge to using HR to monitor exercise intensity. The purpose of this study was to assess the potential of breathing frequency (BF) to monitor exercise intensity in people with AF and CHD without AF. METHODS: This observational study included 30 AF participants (19 Male, 70.7 ± 8.7 yrs) and 67 non-AF CHD participants (38 Male, 56.9 ± 11.4 yrs). All performed an incremental maximal exercise test with pulmonary gas exchange. RESULTS: Peak aerobic power in AF ( V ˙ O2peak; 17.8 ± 5.0 ml.kg-1.min-1) was lower than in CHD (26.7 ml.kg-1.min-1) (p < .001). BF responses in AF and CHD were similar (BF peak: AF 34.6 ± 5.4 and CHD 36.5 ± 5.0 breaths.min-1; p = .106); at the 1st ventilatory threshold (BF@VT-1: AF 23.2 ± 4.6; CHD 22.4 ± 4.6 breaths.min-1; p = .240). % V ˙ O2peak at VT-1 were similar in AF and CHD (AF: 59%; CHD: 57%; p = .656). CONCLUSION: With the use of wearable technologies on the rise, that now include BF, this first study provides an encouraging potential for BF to be used in AF and CHD. As the supporting data are based on incremental ramp protocol results, further research is required to assess BF validity to manage exercise intensity during longer bouts of exercise.


Assuntos
Fibrilação Atrial , Doença das Coronárias , Frequência Cardíaca , Humanos , Masculino , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca/fisiologia , Pessoa de Meia-Idade , Idoso , Doença das Coronárias/fisiopatologia , Exercício Físico/fisiologia , Taxa Respiratória/fisiologia , Teste de Esforço/métodos , Consumo de Oxigênio/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
6.
Heliyon ; 10(10): e31187, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38803872

RESUMO

Objectives: The early prediction of death is a challenge for medical staff. We evaluated the ability of the heart/breathing rate ratio (HBR) to predict mortality. Methods: This was a single-center retrospective observational study of adult patients who had fever with or without respiratory symptoms, who survived at least 2 h after visiting the hospital, and whose lactate levels and vital signs were tested. We evaluated the distribution of mortality at different HBR levels and compared HBR with lactate. Results: A total of 18,872 fever clinic visits were screened, and 183 patients whose lactate levels were tested were recruited. Patients who had HBR values lower than 4·5 or higher than 5·5 had greater mortality than patients who had HBR values between 4·5 and 5·5 (21·3 % vs. 3·4 %, p = 0·003; 28·9 % vs. 3·4 %, p < 0·001, respectively). In patients whose HBR was <5, the AUROC for HBR for mortality was 0·762 (95 % CI: 0.643-0·880), and that for lactate was 0·701 (95 % CI: 0·564-0·837). In patients whose HBR was ≥5, the AUROC for HBR for mortality was 0·721 (95 % CI: 0·584-0·857), and that for lactate was 0·742 (95 % CI: 0·607-0·848). Conclusions: HBR is helpful for stratifying mortality risk among critically ill patients in acute care clinics for infectious diseases.

7.
Pain Pract ; 24(4): 609-619, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38087644

RESUMO

OBJECTIVES: Chronic musculoskeletal pain is associated with decreased parasympathetic and increased sympathetic activity in the autonomic nervous system. The objective of this study was to determine the associations between objective measures of heart rate variability (a measure of autonomic nervous system function), actigraphy (a measure of activity and sleep quality), respiration rates, and subjective patient-reported outcome measures (PROMs) of central sensitization, kinesiophobia, disability, the effect of pain on sleep, and life quality. METHODS: Thirty-eight study subjects were divided into two subgroups, including low symptoms of central sensitization (n = 18) and high symptoms of central sensitization (n = 20), based on patient-reported scores on the Central Sensitization Inventory (CSI). Heart rate variability (HRV) and actigraphy measurements were carried out simultaneously in 24 h measurement during wakefulness and sleep. RESULTS: A decrease in HRV during the first 2 h of sleep was stronger in the low CSI subgroup compared to the high CSI subgroup. Otherwise, all other HRV and actigraphy parameters and subjective measures of central sensitization, disability, kinesiophobia, the effect of pain on sleep, and quality of life showed only little associations. DISCUSSION: The high CSI subgroup reported significantly more severe symptoms of disability, kinesiophobia, sleep, and quality of life compared to the low CSI subgroup. However, there were only small and nonsignificant trend in increased sympathetic nervous system activity and poorer sleep quality on the high central sensitization subgroup. Moreover, very little differences in respiratory rates were found between the groups.


Assuntos
Sensibilização do Sistema Nervoso Central , Dor Crônica , Humanos , Sensibilização do Sistema Nervoso Central/fisiologia , Frequência Cardíaca , Cinesiofobia , Qualidade de Vida , Actigrafia , Dor Crônica/diagnóstico , Sono , Medidas de Resultados Relatados pelo Paciente
8.
Chronobiol Int ; 41(2): 213-225, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38153128

RESUMO

Sleep regularity and chronotype can affect health, performance, and overall well-being. This observational study examines how sleep regularity and chronotype affect sleep quality and cardiorespiratory metrics. Data was collected from 1 January 2019 through 30 December 2019 from over 330 000 Sleep Number smart bed users across the United States who opted into this at-home study. A pressure signal from the smart bed reflected bed presence, movements, heart rate (HR), and breathing rate (BR). Participants (mean age: 55.69 years [SD: 14.0]; 51.2% female) were categorized by chronotype (16.8% early; 62.2% intermediate, 20.9% late) and regularity of sleep timing. Participants who were regular sleepers (66.1%) experienced higher percent restful sleep and lower mean HR and BR compared to the 4.8% categorized as irregular sleepers. Regular early-chronotype participants displayed better sleep and cardiorespiratory parameters compared to those with regular late-chronotypes. Significant variations were noted in sleep duration (Cohen's d = 1.54 and 0.88, respectively) and restful sleep (Cohen's d = 1.46 and 0.82, respectively) between early and late chronotypes, particularly within regular and irregular sleep patterns. This study highlights how sleep regularity and chronotype influence sleep quality and cardiorespiratory metrics. Irrespective of chronotype, sleep regularity demonstrated a substantial effect. Further research is necessary to confirm these findings.


Assuntos
Ritmo Circadiano , Transtornos do Sono-Vigília , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Ritmo Circadiano/fisiologia , Sono/fisiologia , Qualidade do Sono , Inquéritos e Questionários
9.
Cureus ; 15(11): e48266, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37929268

RESUMO

Maintaining a healthy diet is essential for pregnant women and their developing fetuses, including being mindful of caffeine consumption. While consuming caffeine during pregnancy is generally safe, there is a concern among healthcare practitioners about whether it can adversely impact pregnancy. There is a lack of accurate information about the effects of caffeine on fetal development and inadequate education on the risks of excessive caffeine intake during pregnancy. Therefore, to address this gap, our review provides an overview of the current literature on the impact of caffeine consumption during pregnancy on fetal development. We thoroughly searched databases, including PubMed and Clinicatrial.gov, from September 2022 to January 2023, focusing on relevant clinical studies with a level of clinical evidence II or higher. Our findings reveal that caffeine intake during pregnancy has notable effects on human fetal development. It increases fetal breathing and heart rates but can lead to reduced growth and a lower birth weight. Although it does not affect gestational length or cause hypertension, caffeine increases uterine contractions, potentially resulting in spontaneous abortion. In some cases, it even contributes to the development of pre-eclampsia in the later stages of pregnancy. However, the data on the association between caffeine consumption and the risk of congenital disabilities remains inconclusive. Based on these findings, it is clear that more extensive research is needed to fully understand the impact of caffeine consumption on the development of congenital disabilities in infants born to caffeine-consuming pregnant women. Furthermore, gaining a deeper understanding of how caffeine affects fetal development and pregnancy mechanisms is crucial.

10.
Heliyon ; 9(9): e20082, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37809652

RESUMO

Personality traits, the consistent individual behavioral differences, are currently gaining much attention in studies of natural bird populations. However, associations between personality traits and parasite infections are not often investigated. Even less attention has been given to studies of birds in the high-elevation region such as the Tibetan plateau. This research aims to examine the relationship between avian malaria parasites and two personality traits in a population of the Chestnut Thrush (Turdus rubrocanus) breed in the Tibetan plateau. Our results revealed no evidence of sex bias in malaria parasite prevalence. Furthermore, we found no effect of infection status on two personality scores: activity and boldness. Additionally, no effects on the activity level or boldness were observed for different parasite lineages of Haemoproteus, Leucocytozoon, the sex of the birds, or their interactions. Similarly, we did not find any relationship between activity level and boldness with nestling numbers, sex, or their interactions. Notably, individuals with a larger number of offspring tended to display greater boldness. Our findings indicate that blood parasite infections are common in this population but do not significantly impact the personality of the birds.

11.
Brain Sci ; 13(3)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36979312

RESUMO

Abnormalities in cardiorespiratory measurements have repeatedly been found in patients with panic disorder (PD) during laboratory-based assessments. However, recordings performed outside laboratory settings are required to test the ecological validity of these findings. Wearable devices, such as sensor-imbedded garments, biopatches, and smartwatches, are promising tools for this purpose. We systematically reviewed the evidence for wearables-based cardiorespiratory assessments in PD by searching for publications on the PubMed, PsycINFO, and Embase databases, from inception to 30 July 2022. After the screening of two-hundred and twenty records, eight studies were included. The limited number of available studies and critical aspects related to the uncertain reliability of wearables-based assessments, especially concerning respiration, prevented us from drawing conclusions about the cardiorespiratory function of patients with PD in daily life. We also present preliminary data on a pilot study conducted on volunteers at the Villa San Benedetto Menni Hospital for evaluating the accuracy of heart rate (HR) and breathing rate (BR) measurements by the wearable Zephyr BioPatch compared with the Quark-b2 stationary testing system. Our exploratory results suggested possible BR and HR misestimation by the wearable Zephyr BioPatch compared with the Quark-b2 system. Challenges of wearables-based cardiorespiratory assessment and possible solutions to improve their reliability and optimize their significant potential for the study of PD pathophysiology are presented.

12.
J Med Internet Res ; 25: e41845, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36633892

RESUMO

BACKGROUND: Apps for smartphones that can measure the breathing rate easily can be downloaded. OBJECTIVE: The aim of this study was to demonstrate agreement in measuring breath rates between the stethoscope and Breath Counter health app. METHODS: We performed a repeatability study with 56 healthy volunteers. The patient's demographic data and breathing rates per minute were collected. Breathing rates were measured via two methods: (1) using a stethoscope placed in the upper area of the right lung and (2) a Breath Counter app developed by Vadion on a Samsung Fold smartphone. RESULTS: This study demonstrated high repeatability and validity with respect to the breathing rate parameter of healthy adults using the aforementioned 2 systems. Intrasession repeatability measure using the intraclass correlation coefficient was >0.962, indicating excellent repeatability. Moreover, the intraclass correlation coefficient between methods was 0.793, indicating good repeatability, and coefficients of variation of method errors values were 1.83% with very low values in terms of other repeatability parameters. We found significant correlation coefficients and no systematic differences between the app and stethoscope methods. CONCLUSIONS: The app method may be attractive to individuals who require repeatability in a recreational setting.


Assuntos
Aplicativos Móveis , Estetoscópios , Humanos , Adulto , Reprodutibilidade dos Testes , Smartphone , Pulmão
13.
Bioengineering (Basel) ; 9(11)2022 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-36421112

RESUMO

With advances in portable and wearable devices, it should be possible to analyze and interpret the collected biosignals from those devices to tailor a psychological intervention to help patients. This study focuses on detecting anxiety by using a portable device that collects electrocardiogram (ECG) and respiration (RSP) signals. The feature extraction focused on heart-rate variability (HRV) and breathing-rate variability (BRV). We show that a significant change in these signals occurred between the non-anxiety-induced and anxiety-induced states. The HRV biomarkers were the mean heart rate (MHR; p¯ = 0.04), the standard deviation of the heart rate (SD; p¯ = 0.01), and the standard deviation of NN intervals (SDNN; p¯ = 0.03) for ECG signals, and the mean breath rate (MBR; p¯ = 0.002), the standard deviation of the breath rate (SD; p¯ < 0.0001), the root mean square of successive differences (RMSSD; p¯ < 0.0001) and SDNN (p¯ < 0.0001) for RSP signals. This work extends the existing literature on the relationship between stress and HRV/BRV by being the first to introduce a transitional phase. It contributes to systematically processing mental and emotional impulse data in humans measured via ECG and RSP signals. On the basis of these identified biomarkers, artificial-intelligence or machine-learning algorithms, and rule-based classification, the automated biosignal-based psychological assessment of patients could be within reach. This creates a broad basis for detecting and evaluating psychological abnormalities in individuals upon which future psychological treatment methods could be built using portable and wearable devices.

14.
Front Psychol ; 13: 963711, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36275219

RESUMO

Breathing interventions have been shown to improve sport performance. Although evidence exists to support the role of perceived arousal as a critical underlying mechanism of breathing interventions, methodological differences in the literature preclude clear understanding of potential contributing factors to the effectiveness of such interventions. Under neutral contexts, we have demonstrated attention, dyspnea, and hindrance may need to be considered as mediators of how breathing frequency affects motor performance. We sought to extend our previous findings to determine how breathing frequency affects motor performance under varying emotional conditions. Participants (N = 35, Mage = 21.68, SD = 2.96; 20 females) performed slow, normal, and fast metronome-paced breathing while viewing pleasant and unpleasant stimuli prior to executing a pinch grip task. Performance was assessed via reaction time (RT), variability (V) and error (AE). Assessment of indices of perceived arousal included measuring heart rate variability (HRV) and visual analog scale responses. Visual analog scales were also used to assess attention, dyspnea, and hindrance. Repeated measures ANOVAs showed slow breathing increased RT and HRV compared to normal and fast breathing under emotional conditions (all p's < 0.05). Hierarchical multiple regression models revealed that decreased breathing frequency predicted increases in RT (ß = -0.25, p < 0.05) under pleasant conditions, while predicting increases in HRV for unpleasant conditions (ß = -0.45, p < 0.001). Increases in dyspnea (ß = 0.29, p < 0.05) and hindrance (ß = 0.35, p < 0.01) predicted increases in RT under pleasant conditions, while only increases in hindrance predicted increases in RT under unpleasant conditions (ß = 0.41, p < 0.01). Decreases in breathing frequency predicted increases in HRV under unpleasant conditions (ß = -0.45, p < 0.001). Overall, our findings suggest under varying emotional contexts breathing frequency differentially affects movement, potentially mediated by factors other than perceived arousal. In addition, these results inform the use of breath regulation as an antecedent emotion regulation strategy.

15.
Front Physiol ; 13: 955208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36304581

RESUMO

Modern microwave Doppler radar-based physiological sensing is playing an important role in healthcare applications and during the last decade, there has been a significant advancement in this non-contact respiration sensing technology. The advantages of contactless, unobtrusive respiration monitoring have drawn interest in various medical applications such as sleep apnea, sudden infant death syndromes (SIDS), remote respiratory monitoring of burn victims, and COVID patients. This paper provides a perspective on recent advances in biomedical and healthcare applications of Doppler radar that can detect the tiny movement of the chest surfaces to extract heartbeat and respiration and its associated different vital signs parameters (tidal volume, heart rate variability (HRV), and so on) of the human subject. Additionally, it also highlights the challenges, and opportunities of this remote physiological sensing technology and several future research directions will be laid out to deploy this sensor technology in our day-to-day life.

16.
Front Neuroanat ; 16: 953746, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35968158

RESUMO

Central motor rhythm-generating networks controlling different functions are generally considered to operate mostly independently from one another, each controlling the specific behavioral task to which it is assigned. However, under certain physiological circumstances, central pattern generators (CPGs) can exhibit strong uni- or bidirectional interactions that render them closely inter-dependent. One of the best illustrations of such an inter-CPG interaction is the functional relationship that may occur between rhythmic locomotor and respiratory functions. It is well known that in vertebrates, lung ventilatory rates accelerate at the onset of physical exercise in order to satisfy the accompanying rapid increase in metabolism. Part of this acceleration is sustained by a coupling between locomotion and ventilation, which most often results in a periodic drive of the respiratory cycle by the locomotor rhythm. In terrestrial vertebrates, the likely physiological significance of this coordination is that it serves to reduce the mechanical interference between the two motor systems, thereby producing an energetic benefit and ultimately, enabling sustained aerobic activity. Several decades of studies have shown that locomotor-respiratory coupling is present in most species, independent of the mode of locomotion employed. The present article aims to review and discuss mechanisms engaged in shaping locomotor-respiratory coupling (LRC), with an emphasis on the role of sensory feedback inputs, the direct influences between CPG networks themselves, and finally on spinal cellular candidates that are potentially involved in the coupling of these two vital motor functions.

17.
Sensors (Basel) ; 22(16)2022 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-36016034

RESUMO

Competitive indoor climbing has increased in popularity at the youth, collegiate, and Olympic levels. A critical aspect for improving performance is characterizing the physiologic response to different climbing strategies (e.g., work/rest patterns, pacing) and techniques (e.g., body position and movement) relative to location on climbing wall with spatially varying characteristics (e.g., wall inclinations, position of foot/hand holds). However, this response is not well understood due to the limited capabilities of climbing-specific measurement and assessment tools. In this study, we developed a novel method to examine time-resolved sensor-based measurements of multiple personal biometrics at different microlocations (finely spaced positions; MLs) along a climbing route. For the ML-specific biometric system (MLBS), we integrated continuous data from wearable biometric sensors and smartphone-based video during climbing, with a customized visualization and analysis system to determine three physiologic parameters (heart rate, breathing rate, ventilation rate) and one body movement parameter (hip acceleration), which are automatically time-matched to the corresponding video frame to determine ML-specific biometrics. Key features include: (1) biometric sensors that are seamlessly embedded in the fabric of an athletic compression shirt, and do not interfere with climbing performance, (2) climbing video, and (3) an interactive graphical user interface to rapidly visualize and analyze the time-matched biometrics and climbing video, determine timing sequence between the biometrics at key events, and calculate summary statistics. To demonstrate the capabilities of MLBS, we examined the relationship between changes in ML-specific climbing characteristics and changes in the physiologic parameters. Our study demonstrates the ability of MLBS to determine multiple time-resolved biometrics at different MLs, in support of developing and assessing different climbing strategies and training methods to help improve performance.


Assuntos
Esportes , Dispositivos Eletrônicos Vestíveis , Adolescente , Biometria , Humanos , Movimento/fisiologia , Postura , Esportes/fisiologia
18.
J Anim Sci ; 100(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35921498

RESUMO

Monitoring cardiovascular and respiratory measurements corresponds to the precision livestock farming (PLF) objective to continuously monitor and assess dairy cows' welfare and health. Changes in heart rate, breathing rate, and oxygen saturation (SpO2) are valuable metrics in human and veterinary medicine to assess stress, pain, illness, and detect critical conditions. The common way to measure heart rate is either manually or with a stethoscope. Under research conditions, heart rate is usually measured with a sports watch chest belt. Breathing rate is obtained by counting the cow's flank movements which is a time-consuming and labor-intensive method that requires training and is prone to human error. No devices are available on the market that enable practical and easy pulse oximetry in farm animals. This study presents a wireless nose ring sensor system (NoRS) composed of thermal and photoplothysmography sensors that attach to the nostrils of four Holstein dairy cows. The NoRS's thermocouple measured the cow's nasal cavity air temperature; an optic sensor measured the IR (660 nm) and RED (660 nm) signals reflected from the cow's nasal septum. Breathing was calculated from the thermocouple signal's center frequency with a fast Fourier transformation or the signal peak count (i.e., oscillations). The breathing rate was compared to breathing observed by concurrently counting the flank movements. Heart rate and SpO2 were measured by integrated pulse oximetry and heart rate monitor module (MAX30101 TinyCircuit) assembled on the NoRS circuit. Heart rate was also measured with FFT and by counting the number of peaks from the optic sensor's raw IR and RED signals. These measures were compared to an off-the-shelf hand-held pulse oximeter's heart rate and SpO2 readings during the same time. The comparisons revealed highly significant correlations for the heart rate readings where the strength of the correlation was sensitive to the method. The correlation between breathing rate and the veterinarian's visual observations was low, albeit significant. Thus, inhale-exhale cycle counting constitutes a more precise approach than flank movement counts. The hand-held device's 96% SpO2 is compatible with near-saturation values expected in healthy cows. The mean NoRS SpO2 reading was 3% less. After further piloting under field conditions, the NoRS will require no animal restraining to automatically and continuously record cows' breathing rate, heart rate, and SpO2.


Monitoring cardiovascular and respiratory measurements responds to the precision livestock farming objective to continuously monitor and assess dairy cows' welfare and health. Changes in heart rate, breathing rate, and oxygen saturation are valuable metrics in human and veterinary medicine that are used to assess stress, pain, illness, and detect critical conditions. This article describes a wireless nose ring sensor system (NoRS) developed to read heart rate, breathing rate, and oxygen saturation from the cow's nostrils and tested on four Holstein dairy cows. These measures were compared to heart rate and oxygen saturation readings obtained from an off-the-shelf hand-held pulse oximeter and a veterinarian's concurrent count of flank movements. The comparison revealed highly significant correlations between the heart rate readings and a low, albeit significant correlation for breathing rate. The mean NoRS oxygen saturation reading was 3% less than the hand-held device. Although commonly used techniques for detecting vital parameters such as heart rate, breathing rate, and oxygen saturation only provide information about the time of examination, the NoRS is a wearable device that can monitor cardiovascular and respiratory measurements remotely and over time.


Assuntos
Oximetria , Taxa Respiratória , Animais , Bovinos , Fazendas , Feminino , Frequência Cardíaca , Humanos , Monitorização Fisiológica/veterinária , Oximetria/métodos , Oximetria/veterinária , Oxigênio
19.
Sensors (Basel) ; 22(14)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35890928

RESUMO

Ultra-wideband radar application for sleep breathing monitoring is hampered by the difficulty of obtaining breathing signals for non-stationary subjects. This occurs due to imprecise signal clutter removal and poor body movement removal algorithms for extracting accurate breathing signals. Therefore, this paper proposed a Sleep Breathing Detection Algorithm (SBDA) to address this challenge. First, SBDA introduces the combination of variance feature with Discrete Wavelet Transform (DWT) to tackle the issue of clutter signals. This method used Daubechies wavelets with five levels of decomposition to satisfy the signal-to-noise ratio in the signal. Second, SBDA implements a curve fit based sinusoidal pattern algorithm for detecting periodic motion. The measurement was taken by comparing the R-square value to differentiate between chest and body movements. Last but not least, SBDA applied the Ensemble Empirical Mode Decomposition (EEMD) method for extracting breathing signals before transforming the signal to the frequency domain using Fast Fourier Transform (FFT) to obtain breathing rate. The analysis was conducted on 15 subjects with normal and abnormal ratings for sleep monitoring. All results were compared with two existing methods obtained from previous literature with Polysomnography (PSG) devices. The result found that SBDA effectively monitors breathing using IR-UWB as it has the lowest average percentage error with only 6.12% compared to the other two existing methods from past research implemented in this dataset.


Assuntos
Radar , Processamento de Sinais Assistido por Computador , Algoritmos , Frequência Cardíaca , Humanos , Polissonografia , Sono
20.
Biosensors (Basel) ; 12(7)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35884344

RESUMO

Waterless transportation for live grouper is a novel mode of transport that not only saves money, but also lowers wastewater pollution. Technical obstacles remain, however, in achieving intelligent monitoring and a greater survival rate. During live grouper waterless transportation, the stress response is a key indicator that affects the survival life-span of the grouper. Studies based on breathing rate analysis have demonstrated that among many stress response parameters, breathing rate is the most direct parameter to reflect the intensity. Conventional measurement methods, which set up sensors on the gills of groupers, interfere with the normal breathing of living aquatic products and are complex in system design. We designed a new breathing monitoring system based on a completely non-destructive approach. The system allows the real-time monitoring of living aquatic products' breathing rate by simply placing the millimeter wave radar on the inner wall of the incubator and facing the gills. The system we developed can detect more parameters in the future, and can replace the existing system to simplify the study of stress responses.


Assuntos
Técnicas Biossensoriais , Radar , Animais , Peixes , Monitorização Fisiológica/métodos , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA